Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹46.4 L+₹61,311.20 (1.34%)Rejected-AOC 64 A JASRAJ MANSION 1ST FLOOR OLD HANUMAN LANE KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹50.9 L+₹5.2 L (11.4%)Rejected-AOC 300 STREET NO 10 PREM BASTI SANGRUR PB PUNJAB 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical As per Para 7 of NIT of the subject tender scan copy of DD uploaded with application but wrong DD recd. Hence, It is recommended that T Bid to be rejected and Seven days will be given to rectify the deficiency |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Nov 2023, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI-88
REPAIRS TO COMPOUND WALL, SECURITY FENCING, GATES, AREA DRAINAGE AND CERTAIN MISC WORKS AT NSD SEWRI, BCF AND JERRICAN FACTORY OF NAVAL DOCKYARD UNDER GE(NW) MANKHURD
2023_MES_624659_1
8266/E8
Open Tender
Civil Works
Item Rate
210 days
GE (NW) MANKHURD
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹90,000
27 Jan 2024
23 Oct 2023
14 Nov 2023
23 Oct 2023
13 Nov 2023
28 Oct 2023
Amount
Demolition of Brickwork or stone/boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
Demolition of Concrete of any description provided in bed blocks coping etc and in any position not otherwise specifically provided for
M&L for walling random ruble masonry,uncoursed,well bonded,bedded and solidly hearted, built in cement and sand mortar (1:6) complete all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints,as specified,of random rubble walling,with maximum depression on face from straight edge 20mm held against the dressed surface.
M&L for rendering 20mm thick in CM 1:4 as stone masonary surface making surface fair & even without using extra cement
M&L RCC M-30 for Bands, Beams, cantilevelers, bressummers, lintels over 1.5m span
Formwork to edges of concrete flats, breaks in floors, openings in concrete walls, floors & roofs & sides of RCC/PCC bands in walls, horizontal or sloping, & similar work all exceeding 20cm wide and sides of RCC/PCC bands in walls,horizontal or sloping an
M&L Mild steel bars 10mm dia & over, cut to length bent to shape required, including cranking, bending spirally for hoping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quali
M&L Same as per Item No 6 Above , but 5mm dia & over upto & including 10cm dia in stirrups, spacers & binders of TMT bars.
M & L cement concrete type B 1 1:2:4( 20 mm graded aggregate), in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directing
M & L for cement concrete 1:2:4 , type B-1 (using 20mm graded stone aggregate) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like in surface benching including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work.
M&L in repairs Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165
M&L in repairs for Galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining bolts including securing or tying at crossing with and provision of galvanised mild steel wire staples or steel pins, etc as directed.
S&F in repairs for Medium Blade Profile Concertina Coil 600mm dia (5 Spiral Per Running Metre) Made from 2.5mm dia High tensile spring galvanised steel wire of tensile 1500 Mpa with razor shaped barbes of 0.5mm galvanised steel wire of 22mm length and 16mm width out to out and 35mm spacing centre to centre fixed completely approximately weighing 1.42 Kg/mtr with compelte all as directed and specified
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide
M&L for Preparing surfaces of steel and iron work, of any description and girth, not otherwise described, and treated with tar or coal tar black paint as in treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each,
M&L for Rendering 15mm thick in CM 1:4 on fair face of brick /concrete surfaces finished fair and even
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
M & L for aluminium anodised suspended false ceiling fixed in repairs in the panels of size consisiting of 600x600 mm lay in tiles 8 mm thick with PVC lamination on the face side and metalized polyester film on backside as granular pattern of saint gobain/Armstrong/equivalent; with aluminium anodised angle 30 x30 x 2 mm fixed along the wall and main and cross tees of size 31.75 x 31.75 x 1.6 mm screwed along side of walls fixed with wooden plugs and hanging from existing slab/ steel truss including 6 mm dia GI wire suspended adjustable level from rafter purlins(length as per site requirement) including complete all as directed by Engineer-in-charge. Note : The contractor's quoted rates shall also be deemed to include for making/ cutting opening in the ceiling of the required size and shape for fixing light fitting, cat walk and provision of neccesary scaffolding for complete work at maximum height of 8mtrs etc, complete all as directed.
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty over new surfaces Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down cement or cement lime plaster on concrete surfaces etc including raking out joints, hacking for keys, scrubbing down with water complete, and material & labour for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour Preparation of new plastered surfaces on ceiling and applying three coat of white wash complete all as specified. and directed. Note: The thickness of plaster specified above is minimum thickness and the quoted rates shall also deemd to be include for the provosion of dubbing of the surface and nothing extra shall be payable on this account.and applying all as specified including necessary scaffolding and safety arrangement
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and also taking down of grills (where exists), complete all as specified and directed and S&F standard aluminium section powder coated (minimum thickness of powder coating shall be 50 micron and colour shall be as approved by GE ) as in frame, shutters for doors, window / ventilators, partitions, fixed / openable / sliding or in any pattern, cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass, provision of hinges, screws, plugs, handle, lock, roller, Nylon ball bearing etc complete all as specified and directed (Aluminium section shall be of make Jindal/Hindalco/ Indalco) Note:- Weight of Aluminium sections as per actual or as per IS or as per manufacturer, whichever is less, shall only be considered for payment. Cost of other items / accessories required for entire completion of the work shall be deemed to be included in the quoted rate. However glass panes and wire cloth shall be measured and paid separately as supply only under respective items.
Taking down chowkats or frames, not exc 4 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
Taking down chowkats or frames, not exc 2 Sqm each with wooden/ flush/ PVC /aluminium shutters (Without taking off shutters from the frame) including taking down of hold-fasts by cutting/chasing etc from existing surfaces and providing Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). including providing Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant.WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall beacceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. WPC frame should be matching with shutter and any type of laminate approved by accepting officer is deemed to be included in the qouted rate Size of shutter for each frame will only be considered for mode of measurement.
Taking down cement plaster of any description from brick or stone walls including raking out joints, hacking for key , scrubbing down with water etc complete all as specified
Taking down Shutters of any description n exc 1 sq. m each resecuring, easing , adjusting and refixing in same opening completely all as specified
Taking down Shutters of any description but exc 1 sq. m and n exc 2 sq. M each resecuring, easing , adjusting and refixing in same opening completely all as specified
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 15mm thick in two coats (10+5mm) polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm over new surfaces
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 10mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including material and labour for preparation of new plastered surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and 1 mm thick (minimum) white cement based wall care putty on new surfaces of walls etc, finished even and smooth, complete all as specified and directed.
M&L for structural repairs to Columns,beams and slabs and chajja at maximum height of 8mtrs including scaffolding and safety arrangements completely all as specified and as directed by Engineer in Charge in following steps as mentioned below 1) Chipping , Removing,Carefullly Loose Concrete work by low impact Hammer/Breakar without damaging the structure & cleaning and disposal of malba out side the premises etc. complete as directed. Hard concrete should not be removed by force. 2) M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hr between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.) 3)M&L for Anticorrosive Treatment to Reinforcement using Corroseal - ZR of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces, complete all as specified and directed. 4) M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar to ensure bond between old concrete & new concrete by brush application, complete all as specified and directed. 5) M&L for building up the profile of structural members by using polymer modified mortar from M/s. Krishna Conchem (Molith-PMM) OR Polymer mortar HB of Dr Fixit upto 40mm thickness including levelling, profiling etc in two layers, each layer not exceeding 20mm, complete all as specified and directed. 6) M&L for 5mm thick polymer modified ready mix cement based plaster on the wall surfaces complete all as specified and directed make: easyplast from wall plast/readiplast from ultratech including Preparation of new plastered surfaces and applying three coat of white wash complete all as specified.
Providing and fixing additional steel bar in various structural elements like column ,beams and Slab etc. including drilling ,bending and fixing the bars tying with preleft binding wires etc.
M&L for Providing waterproofing treatment as specified below and at any height of roof surface including removal of watertank, plumbing line during waterproofing making good if any holes and refixing the same as directed by Accepting officer and Engineer in charge complete 1) Dismantling completely existing roof treatment (excluding cement screed bed ) including loosened cement plaster and exposing the top surface of RCC slab and making good the same in CM 1:4 and removing rubbish, etc outside MD land complete all as specified and directed by the Engineer-in-charge 2) M&L for averaging 50 mm thick PCC 1:2:4, type -B-1, using 20mm graded stone aggregated as in padding concrete of roof mixed with WPC in the proportion as recommanded by the manufacturer(s), complete all as specified and directed, 3) M&L 10 mm thick Screed bed or bedding layer in CM (1:3) with WPC when the concrete is still green complete all as specified and directed. 4) M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a). The roof surface shall be throughly wire brushed cleaned to eliminate all sharp projection, washed dried upto and cleaned overall foreign material and dust to receive primer. (b). The dry surface shall be primed with Torch shield primer as per manufacturer’s instructions, manufactured by the same agency as that of APP membrane. (c). Providing and laying APP modified polyester reinforced water proofing membrane with minimum weight of 3.5 Kg/Sqm, as specified here-in-before. (d). The APP membrane shall be laid using torch-on butane application with minimum 10 cm side overlap and 15 cm end overlap. The laying of membrane shall be got done through an authorised applicator of manufacturer of the membrane. (e). The APP membrane shall be taken up to minimum 200 mm on vertical surfaces. The edge of the membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete and other similar situations including Screed bed or bedding layer or mortar 20mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Prepolished Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed including backing coat 10mm thick in CM 1:3.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing Prepolished Kota stone slab 20-25mm thick in riser/treads of steps,in full piece with bull nosing and laid over cement screed and jointed including Screed/backing coat 15mm thick in CM 1:3.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured 450x300x6mm thick glazed ceramic tiles on vertical surfaces such as skirting,dado etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with the colour of tiles, over and including 10mm thick cement mortar backing coat in CM 1:4, complete all as specified and directed.
M&L for Demolition of stone slab and tiles of any size and description or thickness in floors laid bedded and pointed in any mortar including screed bed. and providing coloured Non-skid ceramic tiles 7 to 8 mm thick (square/ rectangular) of approved size, area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match with nthe colour of tiles, over and including 15mm thick cement mortar screed bed in CM 1:6, complete all as specified and directed.
S&F aluminium anodised Grills of approved design for window / Bolcony ventilators and fixing with F/U channel for window, ventilators, balcony openging in architectual or rectangular type in existing building with C.P. brass/ stainless steel screws @ 200 mm centre to centre, , including drilling as required in RCC sections, complete all as specified and directed. Note: The Grills shall be of Model DG-102/DG-104 of Make Deco or equivalent make as approved by the GE.
M&L for 4.8mm thick Sheet glass, ordinary quality and glazing with oil putty/rubber beading in square/rectangular size as required in each pane for Partition/Door/Window/Ventilator and similar works etc.
M&L for 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane or fixing as louvers or in plain surface in ventilators etc
Supply and fixing in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
Supply only stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples
M&Lfor Granite (of any tpe), fixed in repairs 20 mm work (table rubbed and polished) in steps, jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite
M&L for 20mm thick granite of any type work (Table rubbed and polished) in platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
M&L 20mm thick granite of any type work (Table rubbed and polished on both sides) in partitions and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite completely all as described and as directed by Engineer In Charge
M&L Rounding to edges of stone slabs of Granite or Green Marble of any thickness one edge such as in steps (Bull nosed) or Half round in cooking platform,and other similar situations completely all as specified and as directed by Engineer in Charge.
S&Faluminium alloy, anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy and fixedd nuts, four on bolt plate and two on staple plate and fixed,300mm complete. fixed in repairs
S&F aluminium, anodised, barrel tower bolts of extruded section and fixed 150 mm fixed in repairs
S&F aluminium anodized extruded sections barrel tower bolt 150mm long
S&F Stainless butt hinges with brass screws, size 100mm fixed in repairs
S&F Stainless steel Butt hinges 100mm long with mild steel hinge pin, bright polished and fixed, complete all as specified
S&F extruded aluminium alloy handles, fabricated type., anodised,150 mm fixed in repairs
S&F aluminium anodized extruded sections handle 150mm long
S&F in repairs vitreous China wash basin white, flat back size 550 x 400mm including 15mm dia fancy type pillar tap of Make ESSCO Model no DLX-507KN or equivalent of make Parko as approved by the GE, , chromium plated CP waste coupling, chain and plug, waste fitting, union and waste pipe 32mm dia of required length and all necessary 450mm long outlet and inlet PVC connections pipes with PTMT check nuts complete.
S&F in repairs vitreous china urinal half stall type (back or corner wall type ), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement with discharge pipe etc complete all as specified and as directed by Engineer In Charge.
S&F,in repairs Vitreous china of special colour (as approved by GE), Wash hand basin, Counter type, as per Jaquar Essco Catalogue, ECS-WHT-601 Oval type of size 530mm x 440 x 200mm complete fixed in counter opening with 15mm bore, CP, brass, pillar tap of Model no DLX-507KN, cast copper alloy, with fancy round heads, screwed down, high pressure, long screwed shanks and flynuts, screwed for iron pipe or required length with CP, brass, waste coupling of 32mm bore and fresh water connection pipe of 450mm long of 15mm bore with fibre reinforced PVC material having brass check connecting nuts & washers at both sides and all connections complete providing opening cut size granite20mm slab of matching colour in platform and supports etc all as directed by Engr- in-Charge. Note :- Granite will be measured seperately under relevant item
S&F in repairs vitreous coloured China Europeon water closet (Pedestal Pattern) including 10 ltr capacity low level flushing cistern with necessary PVC connections 15mm size with PTMT nuts of length 450mm long etc complete. Jaquar Essco Model No of EWC - ECS-WHT-551SNPP183LZ or ECS-WHT-551PNPP183LZ
M&L for fixed in repairs 15 mm dia Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified , Cat No 187 of Prayag or equivalent make as approved by the GE complete all as speicified
S&F fixed in repairs Two way Bib cock with flange 15mm dia Model no DLX-512ANKN of ESSCO or equivalent of MarC ,Parko as approved by the GE complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Stop Cock, Make ESSCO Model no DLX-526NKN or equivalent of make Parko as approved by the GE, complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Bib Tap, Make ESSCO Model no DLX-511KN or equivalent of make parko as approved by the GE, complete all as specified and directed.
S&F fixed in repairs 15mm bore brass CP Pillar cock 15mm dia Model no DLX-507KN or equivalent of make parko as approved by the GE, complete all as specified and directed.
S&F in repairs brass chromium plated, shower rose, 125mm size with and including 195mm long 15mm bore brass chromium plated shower arm with bend of 45 degree, complete all as specified and directed.
S&F for PVC (SWR) multi floor trap 75mm dia with grating including jointing with solvent cement
Supplying and laying in repairs against any dia GI tubing of 16mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Supplying and laying in repairs against any dia GI tubing of 20mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
Supplying and laying in repairs against any dia GI tubing of 25mm Outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified, complete all as specified and as directed.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors 110 dia.
M&L for PVC (SWR) pipes fixed in repairs single socketed in any length with rubber ring joints laid in trenches or floors but 75mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 110mm dia
M&L PVC (SWR) pipes fixed in repairs single socketed in any length with rafter joints fixed to wall of 75mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia
M&L for PVC (SWR) bends fixed in repairs any radius of 110mm dia provided with access door
M&L for PVC (SWR) bends fixed in repairs any radius of 75mm dia provided with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 110mm dia bore provided with access door
M&L PVC (SWR) Junction single, fixed in repairs (Single T) equal or unequal of 75mm dia bore provided with access door
M&L for PVC (SWR) fixed in repairs vent cowl of 110mm dia
M&L for PVC (SWR) fixed in repairs vent cowl of 75mm dia
Cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for and forming channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required internal dia of pipe 150mm maximum
Cutting into existing manhole for connecting new drains making good to pipe and rendering cutting out existing benching for and forming channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required internal dia of pipe 100mm maximum
S&F in repairs rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I capacity 1000 Ltr complete fixed to pipe etc all as directed
S&F in repairs ball brass valves high pressure with polyuthene float valve and fly nutcomplete screwed for iron pipe or brass ferrule and fiexed in repairsFloat valve 20mm
S&F in repairs Gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe and fixed in repairs 20mm bore
M&L for Cement concrete in C1 type (1:3:6) using 20mm graded stone aggregate as in plinth protection and finished even and smooth with using extra cement.
M&L Precast cement concrete cover slabs 75mm thick and Crossectional area exc 0.36 Sqm and n.exc 0.5 Sqm each for drain cover and similar work with plain faces set in cement mortar 1:6 complete all as speicified and directed.
Preparation of old surfaces on walls (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
Preparation of old surfaces on ceiling (plastered or unplastered or previously white washed) and applying one coat of white wash complete all as specified.
M & L for complete removal of existing treatement preparation for applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm over & including priming coat of extreior primer applied @ 0.90 litre/10 sqm including exterior wall care putty of minimum 1mm thickness over new surfaces
M&L for complete removal of existing treatment by washing, rubbing down and stopping of old decorated surfaces on walls, preparation for distempering and applying two coat of oilbound distemper over a coat of primer including stopping of nails holes,cracks etc and levelling with minimum 1 mm thick white cement based wall care putty for obtaining plain surface complete all as specified and directed.
Preparation of old surfaces on walls (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.
Preparation of old surfaces on ceiling. (plastered or unplastered or previously colour washed) and applying one coat of Colour wash complete all as specified.
Preparation of old surfaces on walls (plastered or unplastered or previously distempered ) and applying one coat of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. complete all as specified.
M & L for preparation of old wooden surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old wooden surfaces of any description n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old painted steel surfaces of any description and applying one coat of synthetic enamel paint complete all as specified and directed.
M & L for preparation of old Steel surfaces of any description n.exc 10cm width or girth & applying one coat of synthetic enamel paint complete all as specified.
M & L for preparation of old surfaces for applying one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resisitance as per IS 15489:2004, alkali & fungal rsistance, dirt resistance exterior paint of required shades(Company Depot Tinted) with silicon additives @ 1.43 litre/10sqm
M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in foundation filling and mass concrete
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in hard/dense soil complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40mm graded stone aggrigate as in foundation filling.
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting CM 1:6 in mortar ,Type B1,1:3:6,(20mm graded aggregate) complete all as specified and directed.
Returning, filling including spreading, leveling watering and well ramming in layers n.exc 25cm in hard/dense soil complete all as specified and directed by Engr-in-Charge..
Removing excavated material to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6)
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4)
S&F in repairs Pre-painted Corrugated galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 12 Mtr
S&F in repairs Pre-painted Plain galvalume sheet having aluminium zinc coating with hot dip alloy of 55% Aluminium 43.5% Zinc 1.5% Silicon and finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having overall width and laid width as specified GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with fixed using hot dip galvanized, self drilling and self tapping screws neoprene and EPDM washers. Penetrations and laps in sheet shall be sealed by using proper sealant profile. HDPE fillers shall be provided wherever required to close voids between sheets, sheet & fasteners etc. completely all as specified and as directed. upto maximum height of 12 Mtr
Labour only for Cutting chases pinning in making good to facing where required and pointing in CM (1:4) to end of edges of shelves lintels etc. and cutting chases for concealed water tubing and making good cutting not exc 10cm girth
M&L for machine cut cudappa stone slab 20 to 25mm thickness over cement screed bed laid and jointed with grey cement slurry mixed with pigments to match the shed of the slab including rubbing and polishing complete.
S&F fixed in repairs Chromium plated Towel rod 600mm long including built in side brackets Model no AEC-1111N
S&F fixed in repairs Chromium plated Toilet paper holder Model no AEC-1151N
S&F fixed in repairs Chromium plated Towel ring Model no AEC-1121N
S&F fixed in repairs Chromium plated Soap dish Model no ACN-1131N
S&F in repairs Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F in repairs Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, madeup from with wood free EPS supplying & fixing in frame at site as per specification & drawing
S&F aluminium alloy anodized sliding door bolt with hasp and stapple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed 300mm long
S&F in repairs Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. Note : A sum of Rs. 86170.00 towards sch of credit shall be deducted to arrive the contract sum.
M/s Mukesh Engineers
KRISHNA ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .