Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.1 LAccepted-AOC DEVI MANDAP ROAD NEAR OFFICERS BANK COLONY PO HEHAL PS SUKHDEO NAGAR RATU ROAD RANCHI JHARKHAND RANCHI JHARKHAND 834005 | RANCHI | JHARKHAND | 834005 | ₹68.1 L | L1 | Accepted-AOC Agency being L1 |
| 2 | L2₹69.9 L+₹1.9 L (2.72%)Rejected-Finance F 203 MANGAL BAZAAR LAXMI NAGAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹69.9 L+₹1.9 L (2.72%) | L2 | Rejected-Finance Quoted Higher than L1 |
| 3 | L3₹73.9 L+₹5.8 L (8.54%)Rejected-Finance | ₹73.9 L+₹5.8 L (8.54%) | L3 | Rejected-Finance Quoted Higher than L1 |
| 4 | L4₹76.9 L+₹8.8 L (13.0%)Rejected-Finance C O DAROGA SINGH INDRA NIWAS ST PETERS SCHOOL LANE VILLAGE TOWN BIRSA CHOWK PRAKASH NAGAR CITY RANCHI | ₹76.9 L+₹8.8 L (13.0%) | L4 | Rejected-Finance Quoted Higher than L1 |
| 5 | L5₹85.2 L+₹17.1 L (25.1%)Rejected-Finance | ₹85.2 L+₹17.1 L (25.1%) | L5 | Rejected-Finance Quoted Higher than L1 |
| Sl No | Description | Qty | Unit | Proficio Engineering And Construction Pvt. Ltd. L2 | M/S DAROGA SINGH CONSTRUCTION COMPANY L4 | ASHOK KUMAR SINGH L1 | M/S SANJEEV KUMAR L5 | S S Enterprises L3 | M/s Ram Pravesh Singh L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Note: The tender rate should be inclusive of all taxes, duties, cess, fee , royalty charges etc. levied under any statute but exclusive of GST. | |||||||||
| 1.01 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. : All kinds of soil | 460 | Cum | 50 ₹23,000 Lowest | 120 ₹55,200 | 76.1 ₹35,006 | 140 ₹64,400 | 95 ₹43,700 | 125 ₹57,500 |
| 1.02 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. | 270 | Cum | 50 ₹13,500 Lowest | 80 ₹21,600 | 84.03 ₹22,688.1 | 160 ₹43,200 | 100 ₹27,000 | 75 ₹20,250 |
| 1.03 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) | 7 | Cum | 5,000 ₹35,000 | 5,200 ₹36,400 | 3,377.96 ₹23,645.72 Lowest | 6,000 ₹42,000 | 5,300 ₹37,100 | 4,500 ₹31,500 |
| 1.04 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) | 50 | Cum | 3,500 ₹1,75,000 | 4,000 ₹2,00,000 | 2,920.7 ₹1,46,035 Lowest | 5,000 ₹2,50,000 | 4,200 ₹2,10,000 | 4,200 ₹2,10,000 |
| 1.05 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 4 | Cum | 6,000 ₹24,000 | 5,500 ₹22,000 | 4,933.08 ₹19,732.32 | 9,000 ₹36,000 | 7,100 ₹28,400 | 4,800 ₹19,200 Lowest |
| 1.06 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete. | 420 | Sqm | 200 ₹84,000 | 100 ₹42,000 Lowest | 168.13 ₹70,614.6 | 300 ₹1,26,000 | 140 ₹58,800 | 365 ₹1,53,300 |
| 1.07 | Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. | 100 | Sqm | 400 ₹40,000 | 150 ₹15,000 Lowest | 397.56 ₹39,756 | 800 ₹80,000 | 280 ₹28,000 | 450 ₹45,000 |
| 1.08 | Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers. | 270 | Sqm | 200 ₹54,000 | 120 ₹32,400 Lowest | 315.73 ₹85,247.1 | 600 ₹1,62,000 | 260 ₹70,200 | 450 ₹1,21,500 |
| 1.09 | Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts. | 310 | Sqm | 280 ₹86,800 | 120 ₹37,200 Lowest | 254.54 ₹78,907.4 | 800 ₹2,48,000 | 280 ₹86,800 | 450 ₹1,39,500 |
Tender Value
₹1.1 Cr
EMD Value
₹3.3 L
Closing Date
12 Apr 2025, 6:00 pmClosed
Raunak Verma, SM(E-C), AAI
O/o Senior Manager (E-C), Civil Project Office, AAI, B.M. Airport, Ranchi.
Construction of Frisking Room, vehicular lane shed at operational area entry gates and Boundary wall along CISF Barrack at B.M. Airport, Ranchi.
2025_AAI_230568_1
AAI/RC/SM(EC)/Frisking/2024-25
Open Tender
Civil Works
Item Rate
210 days
O/o SM(E-C), AAI, B.M. Airport
Please refer tender documents
8 documents required · 8 mandatory
₹1,180
₹3.3 L
O/o Senior Manager(E-C) AAI, BM Airport Ranchi.
3 Dec 2025
21 Mar 2025
14 Apr 2025
22 Mar 2025
12 Apr 2025
22 Mar 2025
22 Mar 2025 - 29 Mar 2025
27 Mar 2025
Amount
Note: The tender rate should be inclusive of all taxes, duties, cess, fee , royalty charges etc. levied under any statute but exclusive of GST.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. : All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-lll) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete.
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform.
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts.
Centering and shuttering including strutting, propping etc. and removal of form for : Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like.
Centering and shuttering including strutting, propping etc. and removal of form for : Weather shed, Chajjas, corbels etc., including edges.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. : Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. : Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level : Concrete of M25 grade with minimum cement content of 330 kg /cum
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per 1S: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete. : Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level : Concrete of M25 grade with minimum cement content of 330 kg /cum
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:6 (1 cement : 6 coarse sand).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. : Granite stone slab of colour black, Cherry/Ruby red : Area of slab over 0.50 sqm
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge : Granite work
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) : Kiln seasoned and chemically treated hollock wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :200x10 mm
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :125 mm
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.:Twin rubber stopper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. : Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes : 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion : Bend 87.5° : 110 mm bend
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion : Shoe (Plain) : 110 mm bend
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with MS screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sgm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand)
6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
Neat cement punning.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour : Two coats
Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: Channels, angles, tees and flats
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge.
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead : For thickness of tiles 10 mm to 25 mm
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : Asbestos Cement sheet
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in- charge.
Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilometre, as per direction of Engineer-in-charge.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading,transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5 mm thick) wire of high tensile strength of 165 kg/ sq. mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion : Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 20 cm wide, 110 cm overall U-shaped PPGL sheet of thickness 0.5mm for rain gutter with necessary screws etc. including making necessary connections with rain water pipes all complete as per direction and satisfaction of Engineer-in-Charge.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work
Dismantling R.B.T.wire, barbed wire or flexible wire rope or silimar etc in fencing including making rolls and stacking within 50 metres lead etc all complete as per direction and satisfaction of Engineer-in-Charge.
Dismantling concertina coil in fencing/boundary wall including making rolls and stacking within 50 metres lead etc all complete as per direction and satisfaction of Engineer-in-Charge.
Dismantling G.I. chain link fabric fencing including making rolls and and stacking within 50 metres lead etc all complete as per direction and satisfaction of Engineer-in-Charge.
Providing and fixing horizontal R.B.T. reinforced barbed wire alongwith vertical cut pieces of R.B.T. reinforced barbed wire to cover the spacing between wires as and where required, stud tied with G.I. staples and G.I. clips to retain horizontal or vertical, including necessary bolts tied to angle iron upto 3 m height of boundary wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart , all complete as per direction and satisfaction of Engineer-in-Charge.
Add for using extra cement in the items of design mix over and above the specified cement content therein or for using extra cement in richer mixes of concrete.
Conducting soil investigation tests (SPT) for all such locations as required for the design of RCC framed structure of Frisking room (1 no.) & Boundary wall and Steel structure of vehicular lane sheds (1 No) at operational area gates. Testing to be done as per relevant IS code/BIS provisions & the soil test report of the same to be submitted all complete as per direction and satisfaction of Engineer-in-Charge.
Preparation and submission of vetted Structural drawings with design calculations for RCC framed structure of Frisking room (1 no.) & Boundary wall and Steel structure of vehicular lane sheds (1 No) at operational area gates including footing,walls,coloumns, beams, truss etc all complete as per the layout drawings/plan as directed by Engineer-in-charge. The item includes the preparation and submission of Engineering/Structural drawings of RCC & Steel structures, plans and layout drawing as per relevant IS code, building codes and sound engineering practices and provide good for construction Engineering/Structural drawings etc.all complete as per direction and satisfaction of Engineer-in-Charge. The design calculation and structural drawings shall be vetted/approved from any IIT/NIT/Govt. Engeenering college and the fee for the same shall be borne by the contractor. Three copies (each) of the design calculation and good for construction Engineering/Structural including revisions , if any, along with soft copies of the same is to be submitted. The Institute/Consultant will be fully responsible for adequacy, accuracy and quality of the structural design as well as safety of the structure. The report/drawings shall bring out clearly all the details required for design & construction of RCC framed structure of Frisking room, Boundary wall and Steel structure of Vehicular lane sheds etc.
Proficio Engineering And Construction Pvt. Ltd. (BID ID -840264)
S S Enterprises (BID ID -840268)
M/S DAROGA SINGH CONSTRUCTION COMPANY (BID ID -840387)
M/S SANJEEV KUMAR (BID ID -840343)
M/s Ram Pravesh Singh (BID ID -840090)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .