THE DY. DIRECTOR OF HEALTH SERVICES (E AND S)
Central Medical Stores 141, A J C Bose Road, Kolkata - 700014
E-TENDER FOR PROCUREMENT OF SOME CONSUMABLE ITEMS FOR TWO YEARS FROM THE DATE OF AWARD OF CONTRACT (AOC)
2026_HFW_1027781_2
WBHF/CMS/HST/ 1P-158-2026/SCI/2026/399
Open Tender
Equipments
730 days
KOLKATA
Please refer Tender documents.
3 documents required · 3 mandatory
₹50,000
Yes
12 Jun 2026
12 Jun 2026
9 Jul 2026
12 Jun 2026
9 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 110Inline Nebulization system should be capable to generate < 3-micron uniform particle. Should be capable of delivering of all clinically certified aerosol drugs, antibiotics & vaccines for neonatal to adult. It should be a fast and silent operating system and easy to setup. | ||||||
| 110.1 | Inline Nebulization machine ( Controller System)
i. The Nebulization unit should operate on vibrating mesh technology to generate uniform particle of 1-5 micron and should be controlled with wired controller.
ii. The system should have a microprocessor-based controller to aerosolize the drug through the nebulisation unit.
iii. The should be operated with AC/DC adapter (input 100 to 240 VAC 50-60 Hz, output 9V) or from a USB port on medical electrical equipment.
iv. The AC/DC adapter should be warranted against defects in manufacturing for a period of two years from the date of purchase. | 130 | Each | - | - | V15.06/C |
| 110.2 | Nebulization chamber with adapter
1. Nebulization unit should be capable of using with multiple modalities like mechanical ventilator, non-invasive ventilator, HFNC/HFOV machines, stand-alone nebulisation and continuous Nebulization.
2. It should be capable to support Nebulization through standard syringe pumps with dedicated / standard luer connectors eliminate the risk of misconnection.
3. Drop-by-drop continuous Nebulization control with the tubing priming volume range 2- 4ml.
4. The input rate of medication into the Nebulization unit under continuous Nebulization sgould be in a range of 10-12ml/hr.
5. the standalone Nebulization should be used with or without O2 via mouthpiece or mask .
The Nebulizer should be validated for single patient use for up to 30 days intermittent use based upon a typical usage profile of 4 treatments per day or 7 days continuous use with the continuous Nebulization tube set. | 225 | Each | - | - | V15.07/C |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.