Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.2 LAccepted-AOC RAJBARI PARA JALPAIGURI | JALPAIGURI | JALPAIGURI | WEST BENGAL | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.2 L+₹2,257.39 (0.06%)Rejected-Finance 778 N LOWER CHELIDANGA ASANSOL PASCHIM BARDHAMAN | ASANSOL | PASCHIM BARDHAMAN | WEST BENGAL | L2 | Rejected-Finance Rejected | |
| 3 | L3₹40.4 L+₹12,791.71 (0.32%)Rejected-Finance FD 85 SALT LAKE CITY SECTOR III KOLKATA 700 091 W B | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹40.4 L+₹18,159.58 (0.45%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L4 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹88,300
Closing Date
21 Feb 2023, 4:00 pmClosed
Executive Engineer, BMD, PHE, Dte
Office of the Executive Engineer. Bankura Mechanical Division. P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102.
Providing, installation of Pumping machineries with other electro-mechanical accessories for newly sunk TW No-I and TW No-II of Birsingpur piped water supply scheme under Bankura Mechanical Division, PHE Dte. Block- Sonamukhi , Dist- Bankura.
2023_PHED_452369_5
WBPHED/EE/BMD/NIeT- 41 OF 2022-2023
Open Tender
MECHANICAL
Item Rate
180 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹88,300
Yes
19 Apr 2023
2 Feb 2023
23 Feb 2023
2 Feb 2023
21 Feb 2023
2 Feb 2023
Amount
PART-A
Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE 5 star rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) and as per technical specification givebn in NIT Method of starting – star delta Tube Well size-250mm a) Discharge-28 M3/Hour, Total head -75 Mtr N.B-T.C. & G.C. needed. (Manufacturer test certificate along with curve chart should be submitted at the time of delivery)
Supply and delivery of the following materials at site : -
Safety device for the above pump set by supplying MS cage with proper clamping arrangement and nylon rope as per requirement including supply of all required materials with nuts and bolts as required
MS E.R.W as per IS:1239 80mm. dia Heavy type 4.85 mm thick Column pipe with one end socketted and both end threaded
3 mtr long
1.5 mtr long
Heavy type MS fabricated suspension clamp suitable for above 80 mm Ф column pipe with necessary nuts and bolts.
Split type MS fabricated suitable tubewell cover as per tubewell housing with a necessary arrangement for clamping devices including holes for air pipe and cable entry gland
Supply and delivery of following valves
80 mm dia CIDF single door swing check Non Return valve(P.N-1.6) generally conforming to IS 5312 Part I for 80mm delivery line and as per technical Specification given in NIT.
80mm dia CIDF non-rising Sluice Valve (P.N-1.6) generally conforming to IS 14846 and as per technical Specification given in NIT . (for 1 no by pass arrangement )
Supply and delivery of three phase actuator and actutator operated 80mm dia flange type slim seal wafer type butterfly valve (PN-1.6) as per Bs-5155 having valve body of steel cast and shaft steel (AISI-410)Actuator As per technical Specification given in NIT
102mm Ф 0-7 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings
Supply and delivery of 80mm dia following GI specials for delivery line
Pipe (TATA Medium) (including Socket
flange (G.I) heavy type for 80 mm dia
Socket
Supply and delivery of 50mm dia following GI specials for Cable Protection
100mm long short piece
Union
Pipe (TATA Medium) (including Socket)
Supply, delivery and storage at site of following cables
2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date.
1.5 sq mm , 12 core , 1.1 KV Grade PVC insulated Copper Armoured control cable Armoured and Extruded PVC Type ST2 Outer Sheathed As Per IS-7098 (Part 1) 2011 with Up To Date Amendments.
35mm2 3.5Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, (From WBSEDCL meter to MCC & through Voltage stabilizer)
25mm2 3Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, (From MCC meter to out door Kiosk Box)
N.B- All cables should be purchased as per actual site requirement
Supply, delivery at site of following items
Supplying delivery of 100 Amps 415 Volt TPN Sheet steel enclosed re-wireable fuse type Main Switche with side handle operated.
Supplying delivery of 100 Amps 415 Volt TPN Sheet steel enclosed Onload Changeover Switch side handle operated.
Supply and fitting fixing of wall mounted 415 Volt TPN sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required i)100 Amp 4way
Supply and delivery of 415 Volt MCC cum PDB with minimum 2mm thickness and degree of protection IP-54, conforming to IS-8623 with suitable Bus Bar, Digital Voltmeter, Ammeter, contractor, delay timer, MCB, Valve actuator stater etc. with PLC logic & UPS and detailed in as per tecnical specification given in NIT. i) 7.5-12.5 H.P with SDS(Star, Delta )Starter N.B. Single line diagram ,bills of materials and internal circuit diagram should be submitted for approval before delivery of Panel.
Supply and delivery 20KVA oil coolling type Voltage Stabiliser, having unbalance 200 - 500 V input voltage, and 415(±1%) out put voltage , Auto/manual servo voltage stabilizer with U/V,O/V,O/L protection with contactor at out put side, input MCB, Ammeter Bell etc. as per I.E rules and as per tecnical specification given in NIT N.B.:- Manufacturer Test Certificate for Stabilizer, core material, winding copper & oil should be produced at the time of delivery
Supply, delivery and automatically controlled planger type chlorinator dosing pump with Flow Rate 0-100 Ltr./Hr. and Max pressure of 10kg/cm2) with all relive valve and diaphragm rupture indicator , pressure gauge , parure switch, base plate, flexible coupling guard for pump and Motor, foundation bolt, dosing solution of 100 Ltr. capacity and the prime mover to be coupled with pump of 0.5 HP 3 Phase 1440 RPM (+-4%) squirrel cage TEFC induction Motor, Motor will be IE3
b) Supply delivery at site of additional 100 ltr capacity PVC chlorine solution tank for Pump House-I & II
Supply and delivery of 450mm(H) x 300(L) x 250mm(B) size out door CRCA sheet steel fabricated cubical type kenopy top cable jointing box inside fitted 6 nos 63 Amp rated bus bar and hinged type front door and painted powder coated anticorrosive paint as per IP 55 as per direction of E.I.C
Supply delivery of outdoor type LED light fixture Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set. M.No-BRP409 LED115 CW SLC FG PSU GR V2 of Philips make or equivalent model.
Supply delivery 80mm dia M.S Black pipe Medium (Class B) as per IS:1239 PART-1 (2004). i) 1.5 mtr long each x 3 nos for each pump house x 2 nos Pump house (For holding Arm at Pump House Roof)
Supply delivey of 1.5 mtr. long M.S Arm bracket made out of 40 mm dia MS pipe with painted anticorrosive paint .
Supply and delivery of 1200 mm sweep, 1 phase, 60/70 watt, 5 star and having 300 mm down rod, 1.1mm thick alluminium bled, conforming IS 374, 2 mm shank thickness ceilling fan
Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). a) 40 mm dia [ for Control Cable protection]
PART-B
a) Installation of the above PLC automatic panel with pumping machinery,Voltage Stabiliser, Chlorine machine of item no (1 to 16) excluding item no-[7.2 7.3, 7.4 ,11&17] outdoor lighting, outdoor type actuater making delivery line, washout line by the G.I specials, with cable protection pipe, including cable finishing, supplying of all necessary metrials and including necessary finicing of serounding area of T/W by the brick works, plastering, Net finishing etc and cost of hiring D.G set ( if required) to complete the jobs including Painting of anty corrosive paint in all respect as per tecnical specification and as per direction of E.I.C.
b) Installation & commissioning of above chlorinator with supplying & drawing of suitable length 1.1Kv grade 3x36/03(2.5Sqmm) single core standard FRLSh PVC insulated unsheathed copper wire(approved make) from installed panel board through 20mm size PVC rigid conduct FR(Precision make) incl. necessary fittings as required and continuous earthing from nearest earth grid. This includes the cost of making required height brick foundation base with neat cement finishing by supplying all required materials and testing the entire set as per direction of E.I.C(Height of tank foundation shall be higher than that chlorine machine)
Laying of 1.5Sq mm controll cable through 25 mm dia PVC Schedule-80 pipe in under ground trench, the trench size : 500 mm(W) x 760 mm(D) average depthand also trench to be filled up with shifted soil, levelling up and restoring surface duly rammedas per direction of EIC
Laying of two nos 25 sqmm 3 core Al, Ar Cable in an underground trench in single tier formation (horizontal), the trench size : 680 mm x 760 mm average depth, with brick protection on the top of each cable 8 (eight) Nos. bricks per Mtr. and 4 (four) Nos. bricks per Mtr. as separator between the bricks and cables and also trench to be filled up with shifted soil, levelling up and restoring surface duly rammed
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Making 300mm(W) x 300mm(B) x 900 mm (H) size rising main supporting brick pillar at least 300mm depth from ground level to pumping floor level and neat cement finish all complete as per direction.
Making internal wiring /electrification of Pump House by 2x 22/0.3(1.5DSq mm + 1x 22/0.3(1.5sqmm) single core PVC insulated multistranded FRLSH grade flexible copper wire through 20mm PVC conduit pipe/cashing by supplying one no 40Amp, 10KA , 240/415V , 50HZ, SPN/DP MCB isolator conforming to IS/IEC:60947-3, C characterise / As per approved vendor list of PHED vide no-PHE/IV/2277/W-181/19 dated-25-09-21 with required model PVC Board & Piano key type switch (Avg Run 6mtr). i) LED Tube Set point-2nos, Bulk Head light point-1no each with necessary earthing arrangement & one fan point(Total point 6nos)including drawing power DB through 20mm PVC cashing caping (precision make) as per direction of EIC(fitting cut-out to SPN/DP MCB wiring should be with continuous earthing arrangement and 20W two no’s x 4ft long LED tube light make-Philips, Bulk Head light M.No- Endra WT202W LED6S NW PSU S2 PC one nno 0.4 Stap fan regulator fitting etc to be supplyed by agency
Making double Earthing arrangement in complience with I.E rules by G.I pipe electrode with G.I funnel (50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete. For MCC Panel & Voltage Stabilizer
Earthing of cable jointing box with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.incl GI bolts, double nuts, double washers . GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside)and CI hinged inspection cover of 36.56 cm x 35.56 cm with locking arrangement, and connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised strip By ISI-Medium GI pipe
Providing & Installation of Solar Photo Voltaic Panels (Mono/Poly Crystalline) as per MNRE and NIeT Specification for size of solar plant with necessary PV array mounted on independent steel structure of suitable height & in a suitable direction to optimize panel use and withstand the wind pressure up to 200 Km /hour including necessary 3 phase inverter, cable, switch/circuit breaker/connector/junction box, earthing, lightening arrester, installation & commissioning with 5 year CMC. (a) The PV Modules should be mounted on hot dip galvanized metallic structure of adequate strength and as per drawing given in NIT (b) Components & parts used in the solar system including the metallic structure (MS) should confirm to the BIS (c) The rates of solar system includes compressive maintenance contract(CMC) for 5 years .
For T/W No-I
For T/W No- II
Construction of RCC foundation for mounting Steel structure for installation of Solar panel Array including earth excavation, sand filling, brick soling etc and as per speecification given in NIT.
For T/W No-I
For T/W No- II
Cost of supply and delivery at site of calcium hypochlorite granule minimum CI content 60%-65% in air plastic jar (3kg each) as per direction of EIC. (Make PHE approved)
Supply and delivery of safety equipment like Rubber Mat, fire extenguser, hand gloves etc as per technical specification given in NIT
Trial run of pumping machinery, through PLC / Automatic panel also operation of Chlorinator, V.S etc. including operation of rising main valve if required and guarding of installation as per direction of E.I.C.(Each T/W for 90 days) [For T/W No-I & II]
PART-C [ Yard Light for OHR site ]
Supply and delivery and storage of the following at site
Supply of swaged / stepped type steel tubular pole of 9 m long (410‐SP‐26) conformed to IS : 2713-1980. The length of bottom section shall be 5.0 mtr, middle section shall be 2.0 mtr & top of 2.0 mtr. The bottom section of the pole shall be 114.3 x 4.50mm dia, middle section of the pole shall be 88.9 x 4.05 mm dia & the top portion shall be 76.1 x 3.25 dia, 1.5 mtr. long MS bracket made out of 40 mm dia MS pipe shall be fixed on top of the pole for fixing light fiottings. The MS mounting bracket shall be fixed on top of the pole weight approx 92 Kg Make- Calcutta Pole/India Pole/jindal/Any approved make N.B- Certificate of Pole from manufacturer should be produce at the time of delivery
a) Single Arm
Supply delivery & fitting fixing of Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set. M.No-BRP409 LED115 CW SLC FG PSU GR V2 (Make Philips/equivalent model)
Supply and delivery of 6 sq.mm. 2 core PVC insulated XLPE Ar. AL conductor cable, As Per IS-7098 (Part 1) 2011 with Up To Date Amendment
Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
Erection of Single tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting 250 x 250 x 100mm
Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated HRFR 1.1 kv grade copper flaxible cable
Supply and fitting fixing of 20mm dia GI pipe Medium quality (TATA) from muffing to Joint box
Laying through Underground Trech Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Laying on Wall / surface with Saddles / clamps Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F M S saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : For 4 core 6 sqmm cable
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : i) 4 core 6 sqmm cable
Painting of Steel Tubular Pole of lengths and no. of coats of paint,as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint Upto 9.0 mtr. long pole
i) One coat of red lead/Zinc chromate priming
ii) 1st coat of synthetic enamel paint over the primer
ii) 2nd coat of synthetic enamel paint over the 1st coat
Excavation of soil for installation of Earth Electrode and filling & ramming. i) For Soft Soil
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe
a) Supplying and fixing 240/415V MCB Isolator on din rail of existing DBs and necessary connection. i) 40Amp 4 pole Make-Havels/L&T/Legrand/Any Approved make
b) Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection A) 16 A (SPN) Make-Havels
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment a) 2+4 way Make-Havells Enclosure (DHDPSNODRW04)
Add: 18% GST
Add: 1% Cess
M/s. SOMA ENTERPRISE
ELECTRICAL AND MECHANICAL ENGINEERING CORPORATION
EASTERN INDIA SALES AND SERVICE
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .