Construction of Track machine siding at SMET, SRF, KMSI, CMGR, SHYP, MOMU & RNR Stations - (7 nos.)
20-SNT-MYS-2025-02~SWR
20-SNT-MYS-2025-02
Open
Works - General
8 Months
Dharwad, Karnataka
₹0
₹3.3 L
20 Jan 2026
29 Dec 2025
6 Jan 2026
D-Schedule D [ Supply and Installation Portion] 889100.00 Below/P
E-Schedule E [GSU SOR Items]
Duct Integrity test for PLB HDPE Duct, 40/33 mm Dia, as per specification.
Supply and installation of Integrated Multiplexer 1U height, 19" rack mountable, 4*E1 02 uplink, with 4 slots and supporting 8*EM (2W/4W), FXO/FXS and Ethernet card and one slot free for future expansion. Management supporting Telnet as well as NMS. Potential Free contact support. Uplink E1 supporting 4 direction paths as well as 1+1 protection. Unit supports DC(18-72VDC) as well as AC power. Make MROTEK/CISCO/MAPLE.
Supply and installation of E & M card of 8 Channels Suitable to be accommodated in Integrated Multiplexer 1U height of MROTEK make.
Supply of Rodometer (Distance Recorder) as per specification. Make Bosch Model No: 1011662 or better.
Supply of Digital Megger with range selection of 500V,100V,50V. Make Rish Insu 10 or better.
Supply of Digtal Earth Tester Det-1 with metal carrying box and auxiliary earthing net Make Wago or better.
F-Schedule F [ RCIL SOR Portion]
Trenching to a depth of 1 mtr and appropriate width for pipe/duct/Cable and backfilling after laying OFC/duct. This includes provision of 9 bricks / mtr & Fixing of route marker of RCC embossed "RailTel" and painted with Orange, as per specification.
Laying of HDPE duct in trenches. Supply and pulling of nylon rope through it.
Laying of OFC/ QUAD Cable in trench and through HDPE/GI/RCC pipes where ever necessary.
Casting of circular FRP chamber, bottom plate and top covers(1:2:4 concrete mix) with reinforcement, two hooks in each half cover, provision of duct holes as shown in the drawing. 04 Excavation of circular pit to a depth of 1300 mm, dia of 1500 mm, positioning of bottom plates, chamber and top covers .(two halves). Chamber to be filled with river sand to the brim of the chamber after cable blowing and splicing, top covers placed, refilled with excavated soil and rammed etc., complete to the finished item of work as directed by the RailTel Engineer-in-Charge.
Providing dry sand in FRP/RCC joint chambers up to 400mm height
Supply of optical Fibre splicing (Joint) Enclosure (24/48F) as per specification
Splicing and termination of 24/48 Fiber OFC (Splice enclose supplied by RailTel)
OFC route tracing & submission of corrected cable route plan ( soft copy in CD and two hard copies). Cable Route plan should contain LC gates ( culverts/bridges, joint chambers, stations, offset, depth of cable at every 100 mtrs Above/
Trenching to a depth of 1mtr below rail/Road/Platform level , placing of G.I/DWC Pipe as per IS 1239 pt.l&pt.ii), 50 mm dia. (inside) in the trench made, backfilling and ramming
G-Schedule-G [NS Items][Item SN-24 & SN-25 (MSDAC)-Not processed in
Supply of Signal aspect -Shunt LED Signal Lighting Unit with current regulator, as per RDSO specification No. RDSO/SPN/153/2011 Rev 4.1 or latest.
Supply of NON-AC Immunized Relays, Plug-In-Type, style QN1, 8F/8B Contacts, DC 02 Neutral line Relay, Working voltage 24V DC, metal to carbon, with plug bord, retaining clip and connectors as per RDSO Specification No BRS:930,IRS: S: 34 & IRS: S: 23, STR: SIQ 0420 Ver.1 or latest,. The Interlocking code for this relay shall be ABCDF.
Supply of AC Immunized Relays, Plug-In-Type style QNA1, 8F/8B Contact, DC Neutral 03 line Relay, Working voltage 24V DC, metal to carbon with plug bord, retaining clip and connectors as per RDSO Specification No BRS:931A, IRS: S@58<44@ IRS:S:34 & IRS:S:23, STR: SIQ 0420 Ver.1 or latest. The Interlocking code for this relay shall be ABDGH
Supply of Track Relays, Plug in type, Style QTA2 - 9 Ohm, 2F-1B Contacts, metal to 04 carbon with plug boards, connectors and retaining clips as per RDSO specification No. BRS:939A & 966(Appx F2) & IRS:S 23-88 Amdt.1,S34 & 60, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be FGHKX.
Supply of AC Immunized Relays, Plug in type style "QSPA1" 8F/4B contacts ,DC 05 Neutral line Relay, slow to pick up, Working voltage 24V DC, metal to carbon, complete with plug board, retaining clip and connectors as per RDSO Specification No. BRS:933A, IRS:S@58"44@ IRS:S:23;IRS S 60-78, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDEJ
Supply of AC Lamp Proving Relays, Plug in type, Style QECX , 4F-4B Contacts, working 06 voltage 110 V AC, metal to carbon for LED aspects with plug boards, connectors and retaining clips as per RDSO specification No : BRS:941A,STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amdt1, IRS S-23 & 34, STR: SIQ 0420 Ver.1 or latest. The interlocking code for this relay shall be ABDHK
Supply of AC immunized Relays plug in type style QBCA-1, 2HF/4B contacts, DC 07 Biased contractor Relay, Tractive armature, working voltage 24V DC with Heavy duty front contact,Metal to carbon complete with plug board, retaining clips and connectors as per RDSO specification No. BRS 943,IRS. S@46"[email protected]
Supply of Office table with plywood plank with thickness of 4 8mm, teakwood beading with three draws of size 4' X 2' with heavy duty 'S' type chair with hand rest. The above is of Godrej or similar make for storage of documents
Carrying out Alterations to the existing SM's control panel. The work includes drilling of holes on the Top plate wherever required, fixing and wiring of knobs, buttons, counters, LEDs with holder, closing of unwanted holes, carrying out painting alterations on the panel, termination of 09 additional cables and carrying out alteration to the existing wiring as per approved circuit diagram, releasing of unused wires, and painting of particulars as per the instructions of Railway representative at site. (Supply of knobs, buttons and counters is not included in the scope of this schedule). [LED lamps with holder, paint, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Supply of Universal locks with one key for every ten locks.
Supply of cable route tracer/locator as per specifiction- Make stanely or better.
Supply of Insulated Tool Kit consisting of each One No. of following below tools in one set: (a). Friedrich Germany make3/8" sq Dr socket 6mm (b). Friedrich Germany make 3/8" sq Dr socket 8mm (c). Friedrich Germany make 1/2" sq Dr socket18mm (d). Friedrich Germany make 1/2" sq Dr socket 20mm(e). Friedrich Germany make 1/2" sq Dr socket 22mm (f).Friedrich Germany make SP Spanners 10mm (g). Friedrich Germany make SE Spanners 12mm (h). Friedrich Germany make adjustable wrench 8'' (i). Friedrich Germany makead justable wrench 12'' (j). Friedrich Germany make 3/8" sq Dr Ratchet Handle (k). Friedrich Germany make 1/2" sq Dr Ratchet Handle (l). Friedrich Germany make Thandle 1/2'' (m). Friedrich Germany Make Short extension rod1/2'' (n). Stanley make waterproof medium Nylon Tool Bag (o). Friedrich Germanymake1/2"sq Dr Socket 19mm
Alterations to painted termination/ wiring particulars of functions in the Existing apparatus cases-Full Size, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of 13 new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor].
Supply of electric track drilling machine with suitable horizontal stand with attachments to drill holes of various sizes up to 7mm to 13mm Make Rallywolf Model WD 34 C or better. 110V AC
Supply of Digital Megger with range selection of 500V, Make Rish Insu 10 or better.
Supply of Digtal Earth Tester Det-1 with metal carrying box and auxiliary earthing net Make Wago or better.
"SUPPLY OF TX -21/25 KHZ COIL, MODEL NO. G.36R,VERSION: 3.0, MAKE:G.G TRONICS AS PER RDSO SPECIFICATION NO. RDSO/SPN/177-2012 VER.3.0 OR LATEST. MAKE: G.G. Tronics India Pvt Ltd"
"SUPPLY OF RX -21/25 KHZ COIL, MODEL NO. G.36R, VERSION:3.0, MAKE:G.G TRONICS AS PER RDSO SPECIFICATION NO. RDSO/SPN/177-2012 VER.3.0 OR LATEST. MAKE: G.G. Tronics India Pvt Ltd"
"Tx coil for HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with Version 3 or Latest. Make : CEL or similar. Accepted Make/Brand: M/s CEL, Sahibabad, UP"
"Rx coil for HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 with version 3 or latest. MAKE.- CEL or similar. Accepted Make/Brand: M/s CEL, Sahibabad, UP"
Provision of DC Single/ Double rail track circuit in Point zone to suit RE/Non-RE areas as per approved signaling plan using Plug-in type track relays. This work includes provision of double bonding, and parallel jumpers, provision of bond wire clips, provision of track lead connections using 2c X 2.5 sq.mm cable, provision of TLD boxes 2 Nos. at Relay end, 2 Nos. at Feed end and 2 Nos for parallel jumpers as necessary to suit layouts, for each Track Circuit, and termination of jumpers and tail cables in track lead junction boxes, installation of relays, track feed battery chargers to charge up to 4 cells, track feed resistance, B type choke and secondary cells - 80 AH capacity in apparatus cases and wiring with wire PVC 3/0.75mm copper. The work also includes painting of track Circuit No. 21 with Feed end/ Relay end details on the TLD boxes. The work also includes provision of insulations for gauge tie plates and nose crossing plates wherever required. (Provision of rail joint insulation is not covered in this schedule.) (Uninsulated gauge type plate and nose crossing plate will be supplied by Railways. Supply of track feed battery charger, B type choke, track relays, uncharged secondary cells (2V - 80AH), TLD boxes with stumps, 2cX2.5 sq.mm cable, is not covered in this schedule). [track feed resistance, Gauge tie plate and nose crossing plate insulations, PVC/Nylon bushes for TLD boxes, PVC sleeves, all types of fixing bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the contractor. Secondary cells-80 AH capacity shall be charged by the contractor through reputed charging agencies].
Wiring alterantion,configuration and validation of existing datalogger for all new 22 contactas in connection with Toer wagon shed work .this includes additional cards required indata loggerand indoor signalling cable for wiring in existing relayroom. this includes altertion of database in NMS and connected places. 4342698.4
"Supply,installaion,testing and comissioning of Electronic Interlocking (Hot Standby) of Kyosan make as per RDSO spec no RDSO/SPN/203/2011ver.2or latest tosuit thesignallingplanof CM G R Phase-II.this item includes a) Supply of required material for altration in existing E I b) AlterationtoSoftware(Applicationlogic)alongwithTesting(FAT&SAT) and wiring, testing& commissioningof El equipment for the second stageworking as per approvedsignallingPlans. This work includes necessary Design,alterationtothe logic&Interfacecircuits,wiringand testing.Thisworkalso includes any alterations/modifications required earlierphase in Logiccircuitsand VDUsoftwareforstageworking. It includesalteration towiringof DataLogger/RTU, alteration in IPS& power rack,ELD and otherequipments for the second stage working as per approved circuits/Plans. This item also includes supply & extension of ladders and welding/connection of earth of equipments to ring earth asper earthing planand SWR practice along withchange in TOC ,and existing EI drwaings. C) Testing and commissioning of EI systemat a station as awhole includingoutdoorgears.Allartisanstaffandlaboursrequiredfor testing and commissioning of EI withMACLSwork shall be provided by contractorfor for indoor andoutdoorwork.Testingequipment s u c h a s simulationpanel, signal andpoint operation simulationarrangement, multimeteretc.shallbeprovidedbycontractorathisowncost. testing shallbecarriedoutbycontractor inpresence of engineer-in-chargeup tohissatisfactionandneccesaryalterationsshall bedone.Contractor shall depute sufficient staff to carryout indoor work during commissioning for completion of work within stipulated time."
Installation of track device(double rail contact) including digging of trench,fixingofdeflectorplates,trackcrossing, layingofantirodent /antioxidant &non-flamepropagating 26 typedoublewalledcorrugated (DWC) pipemadeup of highdensity polyethyleneofrequired diaas per IS14930part-I OR II or latest and allother accessories as per siterequirement tobedone forlayingof transmitter andreceiver cable, installation of EJB/track side electronicsincluding foundation for trackdevice & earthing as per OEM's guidelines andtechnical requirement & specification to be done bycontractor with their ownmaterial. This also includes OEM pre-commissioningcheck list.
Preparation /modification/altration of existing SIP to Suit approved revised ESP
Supply and Installation of VF Transformer 470 : 600 Ohms Rack Mountable as per RDSO Specification IRS : TC-22/76 or latest.
Supply of STP CAT- 6 Cable compliant with latest EIA/TIA-568-C.2 Standard for CAT 6 Cable 305 Mtrs Roll /Bundle.
Excavation of joint pit/cable coil pit up to the size of lm depth X 1.5m length X l.5m 30 breadth for providing joint/coil at joint locations and at culverts. bridges. L.C gates etc..this includes backfilling and ramming of the pit after the cable laying and onsolidating of the soil as well as disposal of soil as per plan or as advised by the railway representative
Testing of Quad Cable to find the location of LOW insulation/break fault including temporary jointing the cable for testing.
"Supply and Installation of maintenance free earth as per RDSO specs. No RDSO/SPN 97 20O8 or latest and conforming to RDSO Drg. No RSDO/RDSO IF.&B C dtd 19.09.2008. It consist of following Copper bonded steel electrode of 3.0m long 17.2mm macrons and UL listed and marked 1 No. Earth enhancement material supplied in sealed bags sted and marked I No. Earth enhancement material supplied in sealed bags of minimum 10Kg- 3Nos. Copper strip of 1 Copper strip of 300x25x6mm (MEEB):1 no. Copper strip of 150x25x6mm (SEEB):1 No of Supply of 35sq mm multistrand single core PVC insulated copper cable as per 15:694 for connecting main earth 32 electrode to MEEB in the equipment room in triplicate. Supply of 16sq mm multistrand single (i) Digging of earth to required depth (ii) insertion of electrodes (iii) Filling of earth enhancing compound (Approx.30Kgs). (iv) Provision of exothermic weld connection to copper tape of 25mm x 6mm x150mm -01 no to earth electrodes (All the materials tools and feature required for weld will be arranged by the contractor). (v) This includes CC cover 1.5 ft x 1.5ft x 1 ft wall thickness 2 inch with cover 3 inch thickness. Cables 35 Sq mm/16 Sq mm/10 sq mm for connecting earth to bas bar. Busbar to busbar. Busbar to various equipment's. Earth electrode of 17 mm dia and 3.0m long high tensile low carbon steel circular rods and outer surface (minimum copper bonding thickness of 250 micron to made requirement of under writers laboratories (UL) 467-2007 or latest. "
Item Breakup - A-Schedule A [SOR Items 2011]
8000.00 except hard rocky areas including clearing of roots of trees, rocks, bushes etc. to a depth of 1.0 Mtrs and to a width of 0.3 Mtrs. Laying of cables is not included in this schedule.
300.00 the Passenger Platform, trenching to a depth of 0.6m to accommodate the additional cables, replacing the slabs removed after the cables are laid and replastering with cement mortar, refilling the trench by ramming and consolidating it as per the instructions of Railway Representatives at site. Laying of cables is not included in this schedule. [Cement, river sand and all other miscellaneous materials required for the work shall be supplied by the Contractor].
200.00 track crossing of cables, laying of DWC/ RCC pipes with collar/coupling, refilling of trench by ramming and consolidating it as per the instructions of Railway representative at site. During excavation of trench it has to be ensured that the excavated soil does not mix with the ballast available. The depth of 1m trench shall be from the bottom of sleepers for track crossings. Laying of cables is not included in this schedule.(Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule).
100.00 road crossing of cables, laying of DWC/ RCC pipes with collar/ coupling, refilling of trench by ramming and consolidating it and resurfacing it to the original position. Laying of cables is not included in this schedule.(Supply of DWC/RCC pipes with couplers/ collars is not included in this schedule).
80.00 laying with offset at both ends and with couplings over RCC Bridges/ Drainage/ Culverts with concrete masonry supports of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. (Supply of GI pipes with couplings and laying of cables is not included in this schedule.)[Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
80.00 laying with offset at both ends and with couplings over girder bridges by fixing on suitable MS Clamps at an interval of 2 Mtrs. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule.[MS angles, flats, bolts and nuts for manufacturing fixing clamps, bricks, river sand , cement and all other miscellaneous required for the work shall be supplied by the Contractor]. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
80.00 laying in hard rocky area with off sets at both ends duly supported by concrete blocks of size 300mm x 300 mm x 300 mm at an interval of 2m. The ends of the pipes shall be closed with brick masonry work so that no cable is exposed, The work shall be carried out as per the instructions of Railway representative at site. Supply of GI pipes with couplings and laying of cables is not included in this schedule. [Stone jelly of size 20/25mm, bricks, sand, cement and all other miscellaneous materials required for the work shall be supplied by the Contractor].
18000.00 cables as per cable plan in cable trenches, masonry ducts, RCC Pipes, DWC pipes, GI Pipes etc.(Supply of cables is not included in this schedule).
8000.00 width throughout, with earth after laying of cables, and consolidating the trench by ramming and leveling.
200.00 No.CSTE/CN/OFC/1. The lettering on the cable marker shall be "SIG" / "TELE" / "OFC" as per the instructions of Railway representative at site.
200.00 300mmX300mm, casting of concrete foundation of size 300mmX300mmX300mm and Placing of RCC cable markers on top of the foundation and refilling the pit and consolidating it by ramming. The cable markers shall be provided at an interval of 20 Mtrs. within station limits and 50 Mtrs. outside station limits throughout the cable route, diversions and also at every track/road/crossing.
100.00 1.5mx1.5m and depth as instructed Railway representative at site, for coiling the cables in rear of relay rooms/ AFTC huts, apparatus cases etc. The work includes coiling the underground cables, and placing closely one layer of country bricks of size approx. 220mm x 100mm x 60mm breadth wise above the cables to cover all the cables in the cable pit, closing and consolidating the pit by ramming and leveling.[Country bricks of size 220mmx100mmx60mm (app) shall be supplied by the Contractor].
270.00 103.5mm inner dia & 120mm outer dia conforming to specification No. IS 14930(Part 2): 2001 with one coupler for every 6m of pipe as specified in Vol.II of the Tender document.
200.00 as specified in Vol.II of the Tender document.
40.00 specified in Vol.II of the Tender document MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
15.00 and erection of apparatus case full size as per Drg. No.SG/CN/02/6 and fixing of 2 Nos. of 'E' type locks, one for the front door and another for the back door, fixing of one hard wood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red- oxide and two coats of aluminium paints. (Supply of apparatus case is not included in this schedule).[Foundation bolts & nuts, 'E' type locks, cement, river sand, stone jelly of size 20/25 mm, hardwood plank of 37mm thick, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor.]
5.00 6966.60 and erection of apparatus case half size as per Drg, No.SG/CN/02/7, fixing one 'E' type lock for the front door and latching arrangement for the back door, and fixing of one hardwood shelf plank 37mm thick and painting the apparatus case inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of apparatus case is not included in this schedule).[Foundation bolts and nuts, cement, 'E' type locks, river sand, stone jelly of size 20/25mm, 37mm hard wood planks, latching arrangements, paints, varnish, fixing bolts & nuts and all other miscellaneous materials required for the work shall be supplied by the Contractor]
12.00 boxes on rails and concreting as per Drg. No.SG/CN/02/8, drilling of suitable holes in the box, fixing of 2 Nos. of GI pipes 32mm dia and 300mm long at the bottom with clamp nuts - 12 mm thick, one at the inner side and another at the outer side for each pipe for cable throughing, fixing of hardwood plank 37mm thick on the bottom, provision of one EWS lock, and painting the boxes inside and outside with one coat of red-oxide and two coats of aluminium paints.(Supply of CT boxes is not covered in this schedule. Rails of different length shall be supplied by Railways. The contractor shall cut lengthy rails wherever required.)[Cement, river sand, stone jelly of size 20/25mm, paint, varnish , GI Pipes 32mm dia with clamp nuts - 12mm thick - 2 Nos. for each pipe, fixing bolts and nuts with washers, EWS locks, paints and all other miscellaneous materials shall be supplied by the Contractor].
4.00 2895.00 location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location b o x e s . Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected.[All materials required for the work shall be supplied by the Contractor]. a. Shifting of apparatus case (full) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
4.00 1916.25 location boxes very carefully without damaging the working cables and shifting and turning the location boxes to clear of the infringement as instructed by the Railway representative at site. The work includes ensuring the safety of the signaling system, releasing the cable coils to give access for shifting/turning the location b o x e s . Necessary masonry work and earth work in and around the location boxes to the required level shall be done as instructed by the Railway representative at site. If the existing earth connections to the location boxes are disturbed, the earth wires shall be properly re-connected.[All materials required for the work shall be supplied by the Contractor]. b. Shifting of apparatus case (half)
300.00 existing terminals/ fuse blocks in apparatus cases/ battery boxes/ CT boxes/ cable termination racks as per approved circuit diagram. The terminal particulars are to be repainted /corrected on the doors of apparatus cases/ battery boxes/ cable termination boxes and FTOT index board as instructed by Railway representative at site. This work includes closing the opening created for entry of new cables in the apparatus cases with masonry brick work and sealing the bottom of the apparatus cases/ cable termination racks with cable compound.[Paints, wire PVC 3/0.75mm and 16/0.2mm copper, sealing compound, bricks, cement, river sand and all other required miscellaneous materials shall be supplied by the contractor]. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
93.16 cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location)(Phynolic sheet) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
50.00 cables and internal wiring on terminal/ fuse blocks in new apparatus cases, cable termination boxes and in gate Lodges excluding cable termination rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Phynolic synthetic industrial fibre base fine weave cotton fibre board 6mm thick for terminal board to suit each apparatus case, varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination on 25/60mm PBT terminals (new location)(Phynolic sheet) b. Termination on PBT fuse block (new location) (Phynolic sheet) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
60.00 cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. a. Termination of cables on 25/60mm PBT terminals (existing location)
10.00 cables and internal wiring by fixing additional terminals/ fuse blocks on the existing terminal boards of apparatus cases, cable termination boxes etc. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, varnishing all teakwood items, fixing of terminals/ fuse blocks, on the existing terminal boards, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves and also on the inner side of the doors of apparatus cases. After terminations are over, the side openings of apparatus case foundation shall be closed with brick work, cement plastered, the inter- space filled with river sand up to base level and the bottom surface shall be sealed with sealing compound. (Supply of PBT terminals and Fuse blocks is not covered in this schedule). [Cement, teakwood cable clamp 50mm x 50mm, base planks 100mm x 25mm, PVC/Nylon sleeves, varnish, paints, bolts, nuts and washers, Non-deteriorating type of fuses of various capacities, Aluminium cable tags, sealing compound, country bricks 220mm x 100mm x 60mm, copper bus bars, brass screw, river sand, wire PVC3/0.75mm copper and other miscellaneous materials shall be supplied by the Contractor]. b. Termination of cables on PBT fuse block (existing location) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
20.00 suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.(Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor]. a. Wiring of Signal/ point/ LC control circuit (up to 4 relays)
4.00 7349.95 suitable size to hold up to 4/ 8/ 12/ 20 relays as required by Railways and fixing them in apparatus cases for all types of signal control circuits, LC gate control circuit and Point control circuits, fixing of plug boards, relays, resistors and electrolytic condensers on Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, wiring and termination as per approved circuit diagram and painting the particulars.(Supply of all types of relays, plug boards, connectors and retaining clips is not covered in this schedule). [Wire PVC copper, 3/0.75mm and 16/0.2mm copper, Phynolic synthetic industrial fibre base fine weave cotton fibre sheet - 6mm thick to IS specification 2036 - 1995 - Type F5, for fixing resistors and condensers, MS flats 25mm x 6mm brass bolts and nuts, paints, soldering materials, resistors, condensers and all other miscellaneous materials required for the work shall be supplied by the contractor d. Wiring of Signal/ Point/ LC control circuit (up to 20 relays)
240.00 disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a. Painting of existing apparatus case - Full size MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
40.00 disturbing the terminations and equipments inside. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium paint on the inside and outside the apparatus cases, and painting of termination and equipment particulars on the doors of the apparatus cases, as instructed by Railway representative at site. [Aluminium paint, red-oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b. Painting of existing apparatus case - Half size
100.00 standard practice. The work involves scraping of old paint, applying one coat of Red oxide and two coats of Aluminium/ enamel paint on the Signals - complete as instructed by Railway representative at site.[Aluminium paint, red- oxide and all other miscellaneous materials required for the work shall be supplied by the Contractor].
50.00 particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. a. Alteration to painting particulars (apparatus case - Full size)
30.00 particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. b. Alteration to painting particulars (apparatus case - half size)
10.00 particulars of functions in the existing apparatus cases, cable termination boxes, etc., on the PVC/ nylon sleeves and painting of new nomenclature on the existing signaling gadgets. This work includes carrying out alterations of particulars on the inner side of the doors of apparatus cases, re-numbering of apparatus cases and cable termination boxes. [Paints and all other miscellaneous materials required for the work shall be supplied by the Contractor]. c. Alteration to painting particulars (apparatus case-quarter size/ CT box)
60.00 foundations for a width of 0.5m on all sides, up to a level 150mm below the foundation top. This work includes consolidation of earth by watering and ramming. The earth shall be taken from Railway premises as instructed by Railway representative at site. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
7.00 2518.55 foundation as per Drg, No.SG/CN/02/10 using metallic templates, for erection of ground type colour light shunt signal.[Foundation bolts and nuts, cement, river sand, stone jelly of size 20/25mm and all other miscellaneous materials for the work shall be supplied by the Contractor].
7.00 2097.00 including surface base, signal pole, LED aspects/ lenses, bulbs with holders (whichever is applicable), fixing of lens guards, number plate, termination of tail cables, wiring of signal unit with PVC wire 3/0.75mm copper, provision of EWS locks and painting of one coat of red oxide and two coats of Aluminium/ enamel paint.(Supply of Ground type shunt signal complete including surface base, signal pole, LED aspects, holder, bulbs, and lenses is not covered in this schedule).[Wire PVC 3/0.75mm copper, lens guards, EWS locks, Enameled number plates, bolts and nuts, lead wool, paints and all other miscellaneous materials shall be supplied by the Contractor].
10.00 nuts, erection of Post type shunt Signals, termination of tail cables and wiring using wire PVC 3/0.75mm copper, provision of EWS lock and painting of one coat of red-oxide and two coats of aluminium/ enameled paint. The work also includes drilling suitable holes on the CLS post and provision of a through bolt with nut to prevent the Off-set bracket from slipping down. (Supply of Post type Shunt Signals, LED aspects and Off set brackets is not covered in this schedule).['U' bolts and nuts, through bolts with nut, wire PVC 3/0.75mm copper, EWS lock, Enameled number plates, wire mesh, PVC/Nylon sleeves, paints and all other miscellaneous materials shall be supplied by the contractor].
150.00 plates as per drawing No.TY/08/2008 with fixing arrangements and fixing them on the existing Signals as per the instructions of Railway representative at site.[Enameled number plates with fixing arrangements with bolts and nuts shall be supplied by the Contractor]. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
4.00 2289.00 RE/Non RE standard as per approved signaling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable,provision of TLD boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLD boxes, 2c x 2.5 sq.mm cable and TLD boxes with stumps is not covered in the schedule. Existing Track relays, Track Feed Resistance, Track feed battery chargers, 'B' type Chokes and Charged secondary Cells shall used for this work).[Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLD boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. a. Alteration to existing track circuits at feed end
4.00 2127.00 RE/Non RE standard as per approved signaling plan. This work includes provision of double bonding and parallel jumpers, provision of bond wire clips, wherever required, shifting of relay end and feed end equipments and re- wiring them, provision of track lead connections wherever necessary using 2c x 2.5 sq.mm cable,provision of TLD boxes and termination of jumpers and tail cables in track lead junction boxes, shifting of Track feed/Track relay set wherever required and wiring with PVC 3/0.75mm copper wire. (Supply of TLD boxes, 2c x 2.5 sq.mm cable and TLD boxes with stumps is not covered in the schedule. Existing Track relays, Track Feed Resistance, Track feed battery chargers, 'B' type Chokes and Charged secondary Cells shall used for this work).[Wire PVC 3/0.75mm, PVC/ Nylon bushes for TLD boxes, PVC sleeves, all types of bolts and nuts with spring and flat washers, teakwood stand for fixing track feed resistance, GI bond wire 8 SWG, Channel bond pins, bond wire clips, paints and all other miscellaneous materials shall be supplied by the Contractor]. b. Alteration to existing track circuits at relay end MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
40.00 No.SG/SN/02/13 and earthing of metallic sheath and armour of all cables in all apparatus cases, relay room, equipment room, SM's room for block and control, and earthing of all equipments in apparatus cases, power room, relay rack, cable termination rack, control panel, signals, lever frames with MS flat 35mm X 6mm/19c cable (MS flat for closure by areas and MS flat/19c cable combination for farther areas) as per the instructions of Railway representative at site. The work includes painting of earth resistance value on the earth pit. Supply of 19C cable is not covered in the scope of this schedule.[MS flat for earthing 35mm X 6mm, cement, GI earth electrodes, common salt, charcoal, country bricks, river sand, soldering materials and all other miscellaneous materials required for the work shall be supplied by the Contractor].
12.00 IRS type and connecting all ground connections including wiring and termination in point machine and interconnections between point machine and CT box through PVC hose pipe with 3/0.75mm and 7/1.40mm copper wire and painting. This work includes provision of insulation to stretcher bars, throw bar lug and "D" bracket wherever required, cutting of notches on the point machines covers to suit crank handle configuration.(Combined type point machine with ground connection, uninsulated stretcher bar, throw bar lug and 'D' brackets will be supplied by Railways.[All types of insulations connected to point work, coal bengal, all type of bolts and nuts, washers spring/flat wire PVC 7/1.4mm copper, PVC hope pipe, paints, PVC/nylon sleeves and all other miscellaneous materials required for the work shall be supplied by the Contractor].
14.00 with hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
7.00 4118.00 with surface base, signal pole, hood etc., with necessary inspection as per specification/ drawing/ description enclosed in this document.
14.00 of cast iron with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of Off-set bracket (small)
12.00 necessary inspection as per specification/ drawing/ description enclosed in this document.
60.00 with 4 terminals and stumps with necessary inspection as per specification/ drawing/ description enclosed in this document.
44.00 and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. a. Supply of PBT terminal - 25mm centre MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
100.00 and PBT Fuse blocks with necessary inspection as per specification/ drawing/ description enclosed in this document. b. Supply of PBT terminal - 60mm centre
15.00 12012.00 size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size
19.00 size) to suit Southern Railway standard with necessary inspection as per specification/ drawing/ description enclosed in this document: a. Supply of apparatus case - Full size b. Supply of apparatus case - Half size
10.00 sec.s) with plug boards, connectors and retaining clips with necessary inspection as per specification/ drawing/ description enclosed in this document.
40.00 of required ward Nos. with keys, with necessary inspection as per specification/ drawing/ description enclosed in this document.
10.00 specification/ description enclosed in this document.
10.00 description enclosed in this document. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
330.00 rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly. [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50m for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Co Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly. [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50m for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a. Fixing of PBT terminal blocks (25mm/60mm centre) and termination ntractor]. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
40.00 rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly. [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50m for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. a. Fixing of PBT terminal blocks (25mm/60mm centre) and termination b. Fixing of PBT fuse block with ND fuses and termination b. Fixing of PBT fuse block with ND fuses and termination b. Fixing of PBT fuse block Fixing of PBT terminal block/ PBT fuse block, rubber grommets, clamping of cables using teakwood cable clamps and base planks, termination of cables, provision of ND type fuses of required capacities, provision of copper bus bar for supply terminals, wiring, provision of termination particulars diagram board using plywood of thickness 12mm - teakwood finish of size 1800mm x 1200mm with Aluminium grooved channel frame in the relay room. The blank spaces over the top of the cable termination rack shall be covered with phynolic sheet of thickness 3mm wherever required. The termination and cable core particulars shall be painted on the PVC/ nylon sleeves. The work also includes identification of cables using aluminium tags provided on each cable with letters punched neatly. [Wire PVC 3/0.75mm copper, brass bolts and nuts and washers, for fixing PBT terminal/Fuse Block, other fixing bolts and nuts, rubber grommets, PVC/ Nylon sleeves, copper bus bars, teakwood 50mm x 50m for cable clamps, 25mmx 100mm for base planks, phynolic sheet 6mm thick of size 1200mm x 1800mm with aluminium grooved channel frame, phynolic sheet 3mm thick, paint and all other miscellaneous materials shall be supplied by the Contractor]. b. Fixing of PBT fuse block with ND fuses and termination with ND fuses and termination MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
400.00 terminal blocks and wiring of additional relays Relay as per the approved circuit diagram using wire PVC 16/0.2mm copper. Additional wire supporting tray with cover made of PVC shall be provided wherever required. Alterations to Relay particulars shall be incorporated in the relay Index board.(Supply of relays, plug boards, connectors and retaining clips and 50 way terminal boards is not covered in this schedule).[Wire PVC 16/0.2mm copper, 2 BA terminals, teakwood plank 25mm thick for fixing resistors and condensers, soldering materials, bunching thread, wire wound resistance, condenser, wire supporting tray with cover of suitable size made of PVC, paint, varnish and all other miscellaneous materials required for the work shall be supplied by the Contractor
600.00 the relay racks/apparatus cases as per the Relay approved circuit diagram using wire PVC 16/0.2mm copper. The work includes releasing the unwanted wires carefully without disturbing the existing wiring.[Wire PVC 16/0.2mm copper, soldering materials, bunching threads, condensers, resistances and teakwood plank for fixing them and all other miscellaneous materials required for the work shall be supplied by the Contractor].
200.00 than 6mm thick and with an insulation to Foot withstand 650VAC, on the floor of relay room etc at places as indicated by railway representative at site.
7.00 18178.95 Interlocked working of Signals and Points, such as erection and wiring of temporary relay racks and wiring of relays, SM's slide instruments, wiring alterations in the cable termination rack, apparatus cases, signals, Control panel etc, as per the instructions of Railway representative at site. (Supply of relay rack, relays, and SM slide instrument is not included in this schedule). [All other miscellaneous materials required for the work shall be supplied by the Contractor].
7.00 communication at stations/ tents as per the instructions of Railway representative at site. The PA system and magneto telephones will be returned to the contractor after the completion of NI working. Signalling cables available may be used for the communication. (Hiring of PA system equipments and magneto telephones shall be done by the Contractor) [All other miscellaneous materials required for the work shall be supplied by the Contractor].
7.00 same at places as instructed by Railway representative at site. The spacing inside the tent shall be app 8ft x 8 ft. Each tent shall be provided with a table, chair, tube lights and pedestal fan. Drinking water in cans. The tents shall be fixed firmly to withstand rain, strong wind etc. (Rate of Rs.718 is for Per Tent per Day) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
2.00 2943.75 crank handle or on suitable fixtures at station/apparatus case, provision of economiser push switch with locking facility, wiring with wire PVC 16/0.2mm copper, provision of teakwood terminal box covered with decolum along with locking facility and painting. (Supply of electric key transmitter and crank handles is not covered in this schedule). [wire PVC 16/0.2mm copper, wire wound resistance, decolum covered terminal box with locking facility by using 25mm thick teakwood, bolts and nuts, paints, push switches, padlocks a n d other miscellaneous materials required for this work shall be supplied by the contractor].
7.00 9039.00 board in the station master's room. The board shall be made of Phynolic synthetic industrial fibre base fine weave cotton fibre board (matt finish) 6mm thick size 1800mm X 1200mm with aluminium channel frame. The yard layout shall be neatly painted and fixed as instructed by Railway representative at site. [All materials required for the work shall be supplied by the Contractor].
and signalling installations jointly with the Railway representative at site at the stations/ LC gates covered under various schedules of the Contract, and ensuring that all the signalling gears are installed and adjusted as per the existing rules. The work also involves supply of required number of bound registers with good quality papers with all updated details of cable meggering, relays, batteries, block joints, route cancellation, relay room key entries, block instrument key, earth resistance etc., and handing over to Railways. (Supply of 'As mades' is not covered in this schedule). a. Testing and commissioning of stations (upto 5 roads) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
800.00 circuit diagrams, contact analysis charts, termination rack, power supply arrangements, relay index board, cable plans, cable route plans, red boundary plans and all other particulars covered under various schedules. All 'As mades' shall be prepared by the Contractor in AUTOCAD 2000 or latest and submitted in CDs. One copy of the 'As mades' check print shall negatives shall be made in tracing sheet (80 to 90 gsm). All 'As mades' except cable plan, cable route plan, bonding diagram & power supply diagram shall be prepared in A3 size. On approval the contractor shall submit along with the negatives, 8 copies in each, duly making booklet neatly bound. Out of 8 sets, 2 sets of drawings and other plans shall be kept in transparent plastic cover (2 sheets back to back in one plastic cover) and handed over to Railways. Also the contractor has to supply one set of As mades in 'Reproduction Film' The approved circuit diagram will be issued by Railways in soft copy as well as two sets of hard copies. Wherever alterations to existing circuits are involved, the existing as-made circuit diagrams will be supplied by Railways either in CDs or RP film. The Contractor shall incoporate the details of all the new wirings and Railways. On approval 8 copies shall be made for Asmade Circuit diagrams also as mentioned above. (The Rate is for per Sheet)
120.00 power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways.a. For preparationof softcopy from A3 size hard copy.(The Rate is for per Sheet)
7.00 power diagrams, cable plan, bonding plan etc in Auto Cad 200o or latest. The drawings shall be prepared in A3/A2/U size as required by Railways. The hard copies of the documents will be supplied by Railways. The Contractor has to draw the drawings in Auto Cad very carefully and submit one copy of check print along with the soft copy in CD. The drawings shall be checked and returned by Railways indicating corrections if any. The corrections have to be made and final copy submitted in A3/ A2/ U size as required by Railways along with the final soft copy in CD. The hard copy given by Railways have to be returned back without any damage. The size of sheet given in the unit column is for the hard copy given by Railways. c. For preparation of softcopy from U size hard copy.(The Rate is for per Sheet) MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
6.00 5161.00 or latest and submission of negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 CDs. [2 interlocked sidings will be considered equal for one loop line] (Approved permanent way plan will be supplied by Railways).a. for stations upto 4 roads a. for stations upto 4 roads
1.00 9269.00 or latest and submission of negatives in 80/90 gsm tracing paper in 'U' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 CDs. [2 interlocked sidings will be considered equal for one loop line] (Approved permanent way plan will be supplied by Railways).b. for stations from 5 to 8 roads b. for stations from 5 to 8 roads
180.00 in AUTOCAD 2000 or latest (including contact numbers on the circuit) and submission of negatives in 80/90 gsm tracing paper in 'A3' size along with 2 copies and also the soft copy in compact disks induplicate. First, 2 sets of prints shall be supplied to Railways for checking. One set will be returned by Railways to the contractor for making corrections in AUTOCAD. The final corrected drawings shall be supplied to Railways on 80/90 gsm tracing paper and 2 copies of blue prints and the soft copy in 2 CDs. (Approved Signalling plan will be supplied by Railways for preparing table of control. Approved table of control will be supplied by Railways for preparing circuits diagrams).( The rate is for per Sheet)
4.00 1625.25 Half/ Quarter size) without damage after releasing t h e s h e l f planks, Terminal blocks, Fu s e Blocks, Terminal Boards, Relays of all types EKTs, Secondary Cells, power equipments, 'E' type locks, etc., and breaking the concrete foundation. After releasing, the resultant pits are to be closed and consolidated by ramming and levelling. The released materials shall be accounted and stacked at a place as instructed by Railway representative at site.
4.00 and terminals after releasing all the bond wires. The released materials shall be accounted and stacked neatly at a place as instructed by Railway representative at site.
7000.00 as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. a. Transportation upto 100 Kms. MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
14000.00 as per the instructions of Railway representative at site. The work also includes loading and unloading of the materials. b. Transportation more than 100 Kms. Total 4496082.85
Item Breakup - B-Schedule-B [SWR SOR Items]
160.00 holders for Railway signalling, Rated voltage 240 AC/DC to Specn. No. IRS S.78/92 (IRS-S- 78/97 Tentative) IS:13703 (part 2/sec2):1993 suitable for E1 fuse 20Amps SC-20 Holder Safe Clip / knife edge type size E1 (R-SS) amp. Fuse Block for Fuse Catridge
400.00 mm Outer Dia, 10 mm Wall Thickness, along with one coupler for every 6 Meters as per specification No. IS 4984: 2016 with latest amendments and Material Grade:PE 80.
70.00 22780.00 1594600.00 Free Earth as per RDSO Spec No. RDSO/ SPN/197/2008 or latest and as per relevant Technical specification
Digital measurement upto 200A AC/DC True RMS measurement for AC voltage & current.(Large jaw opsize of 18mm ) Model: FLUKE 362/Rishabh or higher specification.
Almirah well/slimline 4S )
7.00 9122.00 or better of App. 5 feet height.
400.00 drawing with Colour (Power board Foot diagram,Relay index chart,Station Rule Diagram, FTOT Particulars, etc), as per instructions of Site In-Charge Railway Representative.
70.00 maintanance registers for SSDAC, point machine, track circuit etc. (100 Pages each of 75 gsm paper)
14.00 Wago/Pheonix/Elmex make or similar
70.00 specificaiton No.IRS-TC 77/2006 Revision1 or latest for quad cable. Total 2680759.00
Item Breakup - C-Schedule C [SWR SOR Items]
400.00 based on RDSO Report No. BS - 105. This also includes insertion of HDPE Pipe of 110mm Outer dia in the Bore drilled.(Supply of HDPE Pipe is not included). MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
500.00 cables and internal wiring on terminal/ fuse blocks in cable termination Rack at relay room. The work includes fixing of all new cables by teakwood clamp on teakwood base plank, fixing of Hylem sheet 10 mm thick for terminal board , varnishing all teakwood items, fixing of terminals/ fuse blocks on the terminal board, drilling of necessary holes, termination of cables, wiring, identification of cables using aluminium tags with letters punched neatly, as per approved circuit diagram and cable plan, painting of particulars on sleeves . After terminations are over, cable entry at the bottom shall be closed with , cement plastered, the inter-space filled with sand upto base level and the bottom surface shall be sealed with sealing compound. Cable armour to be soldered to earth.(Supply of cable termination racks is not included in this schedule). [All bolts and nuts with washers, Hylum Sheet 10 mm Thick, cement, sand, stone jelly, Teak wood base , p a i n t s a n d all other miscellaneous materials required for the work shall be supplied by the contractor]a. Termination on 25/60mm PBT terminals {Per Unit-Per Terminal}
370.00 pipe/DWC/HDPE pipe in which cable is already laid to a size of 300*300mm with 1:3:6 mortar. (All the matetrials required for the work should be supplied by the contractor){Per Unit- RMT}
70.00 12329.00 as per RDSO specification No.RDSO/ SPN/197/ 2008 or latest and as per Technical Specification
24.00 Full/Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, carrying out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.
14.00 terminals of wago/phonix/elmex make or similar and termination of cable at the station/LC gates etc. This includes fixing of Quad/PIJF cables and CT box on the wall.
70.00 type complete for 6 quad cable. After the jointing the through cable has to be tested for insulation resistance and loop resistance in presents of Railway Engineer and in case of any defects the jointing has to be done at free of cost by the contractor. [Heat Shrinkable jointing kit conforming to RDSO specificaiton No.IRS-TC 77/2006 covered in the supply portion has to be used for this purpose. The Contractor should supply all other small items free of cost which are required for making a joint. Only gas blower to be used for blowing MYSORE DIVISION-S AND T/SOUTH WESTERN RLY
30.00 to carry out miscellaneous/sundry works in the Days office/field between 08.00 hrs and 20.00 hrs of the day and accompanying Railway staff with all expenses of transportation, accomodation, food, consumables etc., with all ascents/descents, taxes, octroi, cess, fees, duties, with contractors tools and plants, materials, consumables, labour, crew, machineries with all lead and lift etc., complete as per special conditions, specification, regulation and as directed by Railway Engineer-in-charge. Total 2441632.00
Item Breakup - D-Schedule D [ Supply and Installation Portion]
3000.00 120/103 mm dia, 2 meter long in already dug cable trenches. The unit of RMT means two split pipes of 1 Mtr each. Material shall be supplied as per specification RDSO/SPN/204/2011 or latest" {Per Unit-RMT}
700.00 capping/PVC pipe of minimum 25 mm size or higher as per requirement at site on the wall/floor etc., using bends, coupler and T joints and flexible pipe wherever necessary with fixture in the OFC room from equipment rack to common termination and from OFC room to SM room/Reservation office /Data logger/FOIS room etc. (All required material for fixing to be arranged by the contractor) Total 889100.00
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .