Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹37.7 L+₹4.5 L (13.5%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹37.9 L+₹4.7 L (14.0%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹38.6 L+₹5.4 L (16.4%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹39.7 L+₹6.5 L (19.5%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
19 Mar 2022, 6:00 pmClosed
GE AF THANE
Kolshet Road, Sandoz Baugh Post, Thane 400607
PROVISION OF WALL CLADDING ,ALUMINIUM COMPOSITE PANELLING AND ROOF TREATMENT AT BLDG NO P-02 AT SITE P, CERTAIN BR AND EM SPECIAL REPAIR ,MAJOR REVENUE AND MINOR WORKS AT AFS AT SITE P AND KANHERI HILLS UNDER GE AF THANE
2022_MES_509203_1
8170/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹80,000
Yes
9 May 2022
19 Feb 2022
21 Mar 2022
19 Feb 2022
19 Mar 2022
7 Mar 2022
19 Feb 2022 - 7 Mar 2022
Amount
Removing existing water proofing treatment where so ever exist (except concretepadding) and removing debris/rubbish off the site as directed
Demolition of reinforced cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.
Demolition of cement concrete of any description and in any position complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed by the Engineer-in-Charge.
Material and labour for providing plain cement concrete type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after
Material & labour for providing reinforced cement concrete (1:1½: 3) type A0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture CONPLAST X421IC (Fosroc) or equivalent as per manufactures instructions as in columns, pillars,lintel, slab supported walls roof, landings, balconises, canopies, deck slabs and in shelves etc complete all as specified & as directed.
M&L for Opening out cracks, V section of wall/roof removing the loose material. Filling with cement mortar 1:3 all as specified.
M&L disconnecting existing over head tanks of capacity exc.500 and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment and hoisting, reconnecting and re-fixing in position after necessary work without damaging to existing services etc (including tank nipple and float valve etc). all as specified and directed.
M&L Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed by Engr in Charge.
Material and labour for water proofing treatment with APP based standard membrane over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (MAKE : TEXSA/BITUMAT/BITUNIL/SIKA) (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
Supply only solvent free epoxy concrete bonding agent. Make- Nitobond EP of FOSROC/Carbodur of Sika/ or equilent in PEDILITE
S&F 110MM dia PVC (SWR) Rain water pipes single socketed in any length with rubber joint rings fixed to wall complete all as specified and as directed
S&F 110 mm dia PVC (SWR) bends complete all as specified and as directed
Taking down cement or cement lime plaster,on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and as directed by Engr-in-charge
M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with water proofing compound including finished even and smooth without using extra cement complete all as specified and as directed by Engr-in-charge. Note : WPC will be paid seprately
Supply only integral water proofing compound
S&F 3mm Aluminium Composite Panel as in wall cladding in any shape/design including aluminium anodised frame work for fixing of panels complete all as specified by manufactures and standard design practice and as directed by Engineer-in -Charge
Demolition of cement concrete (reinforced)Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed by Engr-in charge
M&L for reinforeced cement concrete Type B1 1:2:4 (12.5mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-In-Charge.
M&L for reinforeced cement concrete Type B0 1:2:4 (12.5mm graded aggregate) in Columns, pillars, piers, posts and struts and the like complete all as specified and directed by Engr-In-Charge.
Use and waste of Formwork for rough finished surface of concrete to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed by Engr-In-Charge.
Use and waste of Formwork for rough finished surface of concrete to Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engr-In-Charge.
M&L for Mild steel bars 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-In-Charge.
M&L for Mild steel bars 10 mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-In-Charge.
Ditto as item per Item No 23.00 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed by Engr-In-Charge.
M&L for opening out cracks, removing the loose material and Filling with Dr Fixit Crack -X shrinkfree all as specified and directed by Engr-In-Charge.
Dismantelling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-In-Charge.
M&L for 15mm thick mineral board fine fissured in true horizontal level of size 600x600 mm as in false ceiling hot dipped galvanised steel section exposed surfeces with precoated capping main centre to centre size 24mm x 32mm having 0.27mm gauge at every 1200mm centre to centre and wall angle of size 19mm x 19mm having 0.35mm gauged fixed to periphery at every 1200mm c/c on both directions using 3mm thick prestrightened at every 1200mm c/c on both directions using 3mm thick prestrighteed GI wire, laying etc complete all as directed by Engr-in-charge
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-In-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specifiedcomplete all as specified and directed by Engr-In-Charge.
M&L for cement concrete type B0 (1:2:4) ( 12.5 mm graded aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engr-in charge
M & L for rendering 20 mm thick in cement mortar 1:4 (15 mm thick backing coat and 5mm thick finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) complete all as specified and as directed by Engr-in charge
Mirror polishing on marble/ granite/ Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed by Engr-In-Charge.
Demolition of Stone slabs and tiles, laid, bedded and pointed in any mortar of any description or thickness in floors, aprons etc. complete all as specified and directed by Engr-In-Charge.
M&L for Machine cut kota stone slab flooring 50mm thick over 15mm thick 1:4 cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed by Engr-in charge
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick 1:3 cement screed and jointed with ditto as complete all as specified and as directed by Engr-in charge
M&L for Cement concrete type B- 2, 1:2:4 (40mm graded aggregate) complete all as specified and as directed by Engr-in charge
Taking out old unserviceable floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified & directed
Material and labour for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and including 15mm thick screed bed or bedding layer in CM(1:6) complete all as specified and as directed.
Material and labour for glazed ceramic colour tiles 300x200 x7mm thick in skirting/dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) complete all as specified and as directed.
Supply and Fix for Steel Fibre Reinforced Concrete (SFRC) cover and Frame (Heavy duty HD-20 grade designation) of suitable size as per requirment conforming to IS-12592, Total weight of cover and frame shall not be less than 182 Kg,with Temp variation range from -40'C to +80'C & shall be waterproof, weatherproof, durable, Non corrosive, theft proof and shall be fixed in cement concrete complete all as specified and and directed by Engr-in-charge.
Removing building materials etc. to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and as directed by Engr-in-Charge
M&L Hardcore of broken stone or boulder of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge
M&L for cement concrete type B2 1:2:4 (40mm graded aggregate ) in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and as directed by Engr-in-Charge
M&L for cement concrete type D2 1:4:8 (40mm graded aggregate ) in surface channels and drains complete all as specified and as directed by Engr-in-Charge
M&L for cement concrete type C2 1:3:6 (40mm graded aggregate ) in Cement concrete in surface channels and drains complete all as specified and as directed by Engr-in-Charge
S&F Fe 410-W (Gde- E- 250) quality- A, Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and as directed by Engr-in-Charge
S&F factory made heavy duty FRP molded grating square/rectangular with open area 60% for storm water drain cover along with SS fixing sets complete all as specified and as directed by Engineer-in-charge Make
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for fair finished surface complete all as specified and as directed by Engr-in-Charge
Supply and application of Sunplast cement based Hard Plaster system confirming the requirement of WSF (World Squash Federation) consisting of a Base Coat and a Finish Coat of a total thickness of app.15 mm and coated with imported washable paint system. The manufacturer should be recognized by Ministry of Commerce and Industry under the StartUpIndia initiative. Due to the extremely hard nature of the plaster a slight uneven color distribution and micro porous surface checks may be seen once the plaster has dried. This does not affect the strength or the integrity of the plaster and is not to be considered as a defect. Specification : The sysytem consist of a top coat of upto 4mm thickness. Hard plaster to be used as per ANSI A118.4 - A118.1-1999 providing a shear bond of 300 psi and compressive strength of 2750 psi. the water based nonflammable binder to be used to create an everlasting bond between two substrates. It should a viscosity of 10 of 100 cps at 25`C & specific gravity range -1.03+/-0.02. Non Structural wire mesh reinforcement of glass fiber is to be added to the mixture to give further strength to the wall. A single bag plaster covering 62-66 Sqft Mixing of level coat for Comp A : Comp B : Comp C should be maintained as 1:1/4:0.5 in 5-6 Liters of water for second coat. A white enamel paint suiatble for squash playing to be applied in 2 coat over sanded and finished hard plastered wall. The walls are to be same as game marking. Component A - Hard Plaster Component B - Binder Component C - Additive for the squash court.
S&F Made of Tin sheet of 21 SWG being fitted on the bottom side of Front Wall. Total height 480 mm inclusive of wooden frame
M&L for making Game Line Marking will be carried out in Red Colour as per WSF Standards
Taking down Point Wiring (Light, Fan, Socket or Power) of any type on Batten/ PVC Casing & Caping or in Conduit with Fittings and Fixture such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, etc. including necessary Chase cuttings on Brick Walls, Ceilings, Floors, etc. to remove Conduit, etc., complete all as specified and as directed.
Taking down/out unserviceable Wires from the existing Sub-main Wiring of any type and any description, complete all as specified and as directed.
Taking down the existing unserviceable Main Switch/ Cut out/ DBs of any type/ capacity and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable with 1.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn through and including Rigid Non-metallic PVC Conduit 25mm in size, medium grade, ISI marked including necessary Conduit Accessories, Partly Surface/ Partly Concealed as ordered, mounted on 1.6mm thick Sunk Mild Steel Pressed Terminal Box of suitable size duly painted with Red Oxide Metal Primer with 3.0mm thick Plastic Laminated Sheet Top Cover for mounting Switches, Sockets, Fan Regulators, etc. and Earth Continuity connected to Common Earth dolly for ONE LIGHT/FAN POINT CONTROLLED BY ONE 1-WAY SWITCH 6 AMP including grouting Conduit on Brick Walls, etc. and Making Good disturbed Surfaces of Brick Walls, Ceilings, Floors, etc. in Cement Mortar 1:3 and necessary Surface Treatments so as to match with the Existing Finishes, complete all as specified and as directed.
All as per item No. 55.00 here-in-before but for one five pins 5 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No. 55.00 here-in-before but for ONE 3 PIN SOCKET OUTLET 6 AMP ON THE INDEPENDENT BOARD, complete all as specified and as directed.
M&L Point Wiring with 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through/in EXISTING CONCEALED CONDUIT/ PVC CASING & CAPING with Continuous Earth Wire 2.5 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) connected to Main Earth Wire and Earth Dolly providing 3.0mm thick Hylam Sheet Top Cover ISI mark on existing Terminal Box, suitable for mounting Switches, Sockets, Fan Regulators, etc. for ONE 3 PIN SOCKET 16 AMP ON INDEPENDENT BOARD, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable drawn through and including Non-metalic Rigid PVC Conduit of size 25mm dia, medium grade, ISI marked and its Accessories including 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated unsheathed FRLS multi-stranded single core Copper Conductor Cable (Green Colour) as Earth Continuty Conductor along with the Wiring and Making Good Disturbed Surfaces of Walls/Roofs/Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable and 1-Run of 6.0 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed.
S&F PVC Conduit, ISI marked, heavy duty of size 25mm with all Fittings/ Accessories including taking down old unserviceable PVC Conduit, complete all as per specified and as directed.
S&F Switch Piano 6 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Switch Piano 16 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
S&F Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 3 Pin, complete all as specified and as directed.
S&F Socket Outlet 6 Amp & 16 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
S&F Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body complete all as specified and as directed.
S&F Fan Regulator in 5 Step type, Single Pole, 230 Volt, Electronic type, complete all as specified and as directed.
S&F LED Light Fitting 6.0 Watt 6000K, Surface mounted Square/Round shaped (as available) LED downlighter with durable Housing with Aluminum Heat Sink with Diffuser to give Glare Free Light with Removable Driver, complete all as specfied and as directed.
Taking down and refixing Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed.
Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed.
&F Decorative Wall Light Fixture made up of Polycarbonate with LED Lamp 0.5 Watt (Red/Blue/Green) (B-22 Base) Light fixed on the Wall/ Ceiling and connecting up with and including Copper Conductor Cable of size 23/0.0076 Sqmm 3 Core PVC Copper Flexible Conductor and necessary Earthing Connection from to Light Fitting complete all as specified and as directed.
S& F wall mounting fan AC 230 Volts 50 Hz single phase 450 mm sweep, energy efficient, five star rating, with built on ON/OFF & speed regulator inside mounting base oscillating type with aluminium alloy one piece blade double ball bearing heavy duty motor sturdy close mesh guard stainless steel stem having vertiical angle adjustmenty from 22 degree to 45 degree including grouting of MS rugged studs/bolts inwall/column for mounting the fan , complete all as specified and directed by Engr-in-Charge. Make :- HAVELL'S V-3/ Bajaj, Usha, Crompton, Khaitan, Orient.
S&F MCB Single Pole, 6 to 32 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up, complete all as specified and as directed.
S&F MCB Single Pole & Neutral, 40 Amp, 240 Volt, AC, 'B' Series for fixing on MCB DB’s, 10 kA, 50 Hz and connecting up, complete all as specified and as directed.
S&F MCB DB 8-way, Single Pole & Neutral, Double Door type, Regal Grey Colour, Sheet Steel Phosphatised, Powder Coated with 200 Amp rate Bus-bar, Neutral Link Earth Bar & Din Rail duly embedded in Wall including Concealed upto Wall Surface including connecting with existing Cable Incoming and Outgoing with Cable Lugs as per the requirement and and Making Good Disturbed Surfaces of Walls/Roofs/ Floors, etc. so as to match with the existing Finishes, complete all as specified and as directed.
S&F Load Line 4-way Enclosure Double Door with Incomer MCCB 100 Amp rating, 16 KA, 4 Pole and suitable for 415 Volt 50 Hz AC Supply including taking down old unserviceable one, complete all as per specified and as directed.
Supply, Install, Test and commissionig water heater storage type, energy efficient, five star rating electric supplied and installed capacity 25 ltrs including conecting to with PVC pipe 450 mm long for incoming and outgoing water supply with all arrangement of hanging of water heater with required nut bolts, washers complete all as specified and directed
Supply and fix single pole and neutral enclosure with two pin and earth plug and socket with one single pole MCB 20 amps complete all as specified and directed
M&L for Self-closing taps, cast copper alloy, chro-mium plated, screwed for iron pipe and fixed 15 mm dia complete all as specified and directed
M & L GI tubing (Medium grade) with all fitting and fixed to complete on wall and ceiling or laid in trenches of size 15 mm bore all as specified and directed.
M & L for PVC Connection 15mm dia size ISI marked with PTMT Nuts of length 450 mm, complete all as specified and as directed. MAKE : POLYTUF/ PRAYAG
M & L for stop valve, cast copper alloy, screw down high pressure, crutch handle screwed both end for iron pipe, fancy type, chromium plated for 15 mm bore pipe.
M&L for Supply and fix exhaust fan, heavy duty 230 mm sweep, 900 RPM enrgy efficient, with louvers, Single phase, 50 Hz with three core twisted cable of size 23/0.0076 for connecting upto ceiling rose and cutting of wall for fixing the exhaust fan of size 380 mm and making the surface good including masonary work, cement plastering applying distemper job to match the existing colour complete all as specified and directed.``
Supply, Install, Test and commissionig hi wall split units of capacity 1.5 Ton reverse type AC with cooling and heating function, indoor / outdoor complete with 100% copper heating and cooling coils and copper pipes, Cordless Remote Control Unit and with in-built Air ioniser and Plasma Filter for better Indoor Air quality with cordless remote control unit with 4 star rating capacity with non CFC gas including connecting to electric connection complete all as specified and directed.
M&L for Supply and fixing Voltage Stabilizer of capacity 5 KVA with Intelligent Time Delay System, Low and High Voltage Protection, Latest IC Technology, Thermal Overload Protection, Wall Mounting Cabinet design, Input 130-300 , 50 Hz complete all as specified and directed.
S& F wall mounting fan AC 230 Volts 50 Hz single phase 450 mm sweep, energy efficient, five star rating, with built on ON/OFF & speed regulator inside mounting base oscillating type with aluminium alloy one piece blade double ball bearing heavy duty motor sturdy close mesh guard stainless steel stem having vertiical angle adjustmenty from 22 degree to 45 degree including grouting of MS rugged studs/bolts inwall/column for mounting the fan , complete all as specified and directed by Engr-in-Charge. Make :- HAVELL'S V-3/ Bajaj, Usha, Crompton, Khaitan, Orient.
M&L for Ceiling fan of 1200 mm sweep Energy Efficient 5 star rating complete with three blade, canopy and downrod and connecting up to and including provision of flexible three core copper conductor cable from ceiling rose to connector block complete all as specified and directed by Engr-in-Charge
M&L Earthing with Galvanised Steel Earth Plate Electrode 600x600x6.3mm buried directly in ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connected to Galvanised Earth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down/out unserviceable Earthing, complete all as specified and as directed.
MSK Everlast Enterprises
Biju Construction & Co
M/S VISHRANTA CONSTRUCTION
Nissan Electricals
Safe Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .