| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹66.9 LAccepted-AOC 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹66.9 L Quoted ₹68.0 L | L1 | Accepted-AOC QUOTED AMOUNT IS REASONABLE |
| 2 | L2₹70.5 L+₹2.5 L (3.64%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | ₹70.5 L+₹2.5 L (3.64%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹76.3 L+₹8.2 L (12.1%)Rejected-Finance GALI NO 5 6 H NO 6 275 JHARODA MAARA EXTN PART III BURARI NEW DELHI 110084 | NEW DELHI | CENTRAL DELHI | DELHI | 110084 | ₹76.3 L+₹8.2 L (12.1%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹84.6 L+₹16.5 L (24.3%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹84.6 L+₹16.5 L (24.3%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹89.2 L+₹21.2 L (31.2%)Rejected-Finance | ₹89.2 L+₹21.2 L (31.2%) | L5 | Rejected-Finance OTHER THAN LOWEST |
| Sl No | Description | Qty | Unit | MINHAS CONSTRUCTIONS L5 | J.P. Enterprises L4 | V r traders L1 | shiva enterprises L2 | QUALITY CONSTRUCTIONS CO L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles | 25 | Cum | 90 ₹2,250 | 100 ₹2,500 | 49 ₹1,225 Lowest | 111 ₹2,775 | 400 ₹10,000 |
| 2.00 | Dismantling of brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar all as specified & directed. | 592 | Sqm | 9 ₹5,328 Lowest | 10 ₹5,920 | 9 ₹5,328 Lowest | 11 ₹6,512 | 40 ₹23,680 |
| 3.00 | Removal of Mud from top roof slab, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof). | 59.2 | Cum | 125 ₹7,400 | 100 ₹5,920 | 149 ₹8,820.8 | 111 ₹6,571.2 | 50 ₹2,960 Lowest |
| 4.00 | Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases ,landing chajjas and similar suspended work (Reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided | 17 | Cum | 190 ₹3,230 | 200 ₹3,400 | 89 ₹1,513 Lowest | 111 ₹1,887 | 200 ₹3,400 |
| 5.00 | Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed. | 75 | Cum | 90 ₹6,750 | 200 ₹15,000 | 89 ₹6,675 Lowest | 111 ₹8,325 | 140 ₹10,500 |
| 6.00 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises | 735 | Sqm | 9 ₹6,615 Lowest | 10 ₹7,350 | 9 ₹6,615 Lowest | 11 ₹8,085 | 20 ₹14,700 |
| 7.00 | Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per sqm all as specified and directed | 735 | Sqm | 25 ₹18,375 | 10 ₹7,350 | 9 ₹6,615 Lowest | 11 ₹8,085 | 50 ₹36,750 |
| 8.00 | M&L colour joint free Ceramic tiles 8 to 10mm thick area of each tiles exc. 0.18 sqm but n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and as directed. | 1,100 | Sqm | 890 ₹9,79,000 | 850 ₹9,35,000 | 829 ₹9,11,900 Lowest | 999 ₹10,98,900 | 940 ₹10,34,000 |
| 9.00 | Ditto as per above item No 8 but in vertical surfaces as in skirting/dados with backing coat 10 mm thick cement mortar 1:4 all as specifed and directed | 110 | Sqm | 990 ₹1,08,900 | 850 ₹93,500 | 829 ₹91,190 Lowest | 900 ₹99,000 | 940 ₹1,03,400 |
| 10.00 | M&L colour joint free Non-skid Ceramic tiles of size 400 x 400 mm with thickness of 7-8 mm , in ,floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and as directed. | 90 | Sqm | 790 ₹71,100 | 850 ₹76,500 | 699 ₹62,910 Lowest | 700 ₹63,000 | 900 ₹81,000 |
Tender Value
₹93.3 L
EMD Value
₹1.6 L
Closing Date
19 Dec 2025, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
SPL REPAIR TO BLDG NO P-14 (DOUBLE STOREY SINGLE LIVING BARRACKS) AT 5 SIKH LI UNDER GE (NORTH) DELHI CANTT-10
2025_MES_740903_1
CWE/D-77/2025-26
Open Tender
Civil Works
Item Rate
180 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹1.6 L
Yes
19 Mar 2026
21 Nov 2025
20 Dec 2025
21 Nov 2025
19 Dec 2025
12 Dec 2025
Amount
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
Dismantling of brick tiles, terracing tiles, single layer from roof laid, bedded and pointed in any mortar all as specified & directed.
Removal of Mud from top roof slab, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof).
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases ,landing chajjas and similar suspended work (Reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided
Demolition of cement concrete (unreinforced) of any description and in any position not specifically provided for complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Roughening surfaces of old concrete floor by picking sweeping clean and washing down with water to remove dust and brushing neat cement slurry with 3.0 Kg of cement per sqm all as specified and directed
M&L colour joint free Ceramic tiles 8 to 10mm thick area of each tiles exc. 0.18 sqm but n exc 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and as directed.
Ditto as per above item No 8 but in vertical surfaces as in skirting/dados with backing coat 10 mm thick cement mortar 1:4 all as specifed and directed
M&L colour joint free Non-skid Ceramic tiles of size 400 x 400 mm with thickness of 7-8 mm , in ,floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and as directed.
M&L glazed ceramic coloured tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match incl rendering 10 mm thick in CM (1:4) and finished rough, complete all as specified & directed.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar.
M&L 20 to 25 mm thick prepolished machine cut Kota stone slab as in flooring over and including 15mm thick screed bed in cement mortar 1:6, laid over cement slurry @ 3 Kg/Sqm and jointed with grey cement slurry mixed with pigment to match with shade of slab including moulding the edge of slab complete all as specified and as directed. (Note:- The size of Kota stone slab shall not less than 550 mm x 550 mm cut size in flooring and full length single piece in steps, except the location where the balance portion remain less than size as specified above).
M&L 20 to 25 mm thick prepolished machine cut Kota stone slab as in riser or vertical surface over or as in skirting and including 10 mm thick rendering in cement mortar 1:4, and jointed with grey cement slurry mixed with pigment to match with shade of slab including molding the edge where as specified and as directed.
M&L Granite 20mm thick colour as approved ( of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms including cutting and making hole for oval wash hand basin and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in cement mortar 1:6) all as specified and directed
M&L Granite 20mm thick colour as approved ( of any type) work (table rubbed and polished) for wall lining( veneering to wall) 12mm thick in cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in cement mortar 1:6) all as specified and directed
M & L Brickwork with subclass 'B' Brick straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:6 complete all as specified.
Ditto- item No.17 above but except brick complete.
M&L for 50mm thick type-D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base to receive Chequered Cement Concrete tiles and paver blocks all as specified and directed.
M&L for PU Coating Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:4) complete all as specified and as directed.
M&L for chipping of spalled and loose concrete and cleaning rust from re-inforcement by sand brushing scrubing down concrete surfaces with wire brushes cleaning with water allowed to dry applying a layer of zinc rich epoxy primer as antirust on all exposed reinforcement followed by a layer of bonding coat of a layer of epoxy adehessive on complete exposed surfaces of concrete and provide guniting in two layers over steel welded mesh 2 mm dia of wire and total aperture 75 mm, thickness of gunite n.exc 25 mm thick (average thickness) using cement mortar 1 :3 with OPC 43 grade cement mixed with polycrete admixture @ 2 % by wight of cement or as per manufactures instructions and finally applying cement plaster over gunite surfaces of required thickness to give an even uniform and smooth finish conforming to proper Geometrics in cement mortar 1:4 to match with the existing surface as in side and soffits of slabs,chajjas,fins,facias ,parapets ,columns and beams etc complete including necessary scaffolding ,shuttering necessary chased to brick work or RCC members at any height upto four storey buildings incl removing of small trees shrubs etc all as specified(Note: steel welded mesh to be welded with the existing reinforcement. The cost of welded meshis to be welded with the existing re-inforcement is deemed to be included in the quoted rate complete all as specified and directed.
M&L for Reinforced Cement Concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in chajjas complete (reinforcement to be measured separately).
M&L for providing precast cement concrete in window or door cills, lintels, bressumers, steps quoin blocks ( for use with masonry) string coarse coping, post column boundary pillars set in cement mortar 1:4 complete with joint match used in RCC Jali frame in opening etc
M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in columns pillars piers posts and struts etc.
M&L for Reinforcement cement concrete (design mix) in M-25 using 20mm graded stone aggregate as in beams, cantilevers bressummers, lintels over 1.5m span in cluding taking down/dismantling from old position all as specified and directed.
Mild steel TMT bars 10 mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete.
Mild steel TMT bars 6 to 8 mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete.
Ditto as per item no 27 but 5 mm dia and over upto 10 mm dia in stirrups, spacers and binders.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lilntels, cantilevers, shelves inclusing supports, overhangs, etc, also splays between floors and beams, etc.
Use and waste of formwork to chullah hoods, chajjas, throughs and similar items including edges
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.
M&L 15 mm thick Rendering in cement mortar 1:4 on faces of brick work or concrete external surfaces of wall finished even and smooth without using extra cement all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick Rendering in cement mortar 1:6 on faces of brick work or concrete internal surfaces of wall, complete all as specified and directed by Engineer-in-Charge.
M&L 5 mm thick rendering in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even and smooth complete.
M&L for Preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete.
M&L for Preparing new plastered surfaces of wall and applying two coats of oil bound distemper white or tinted over 1mm thick wall care putty on plastered surfaces complete.
M&L for followings :- (i) Removing plaster & finishes all around the RCC memeber. (on all four sides of column to full height, three sidescription of beam to entire span & bottom of slab to area as directed) (ii) After cleaning gently removing cover concrete using pneumatic/electric chipper or any other approved tool in entire portion of structural member (removal of cover concrete shall be done to an extent when reinforcement is visible) (iii) Removal of cover concrete with under cutting of up to a depth of 20mm beyond reinforcement around full circumference in case of coluns & full length of bar where directed. (concrete shall be stripped to an extent concrete substrate is exposed) (iv) Cleaning exposed concrete substrate by using water jet. (v) Removing visible rust along the length of reinforcement using hand tools as approved. (vi) Any other work as directed by Engr-in-charge to present clean surface for determination of type of repair to be carried out.
M&L for providing rust proof /anti corrosive treatment to bars :- (i) cleaning of all exposed bars (new & old) alround (ii) Apply a single coat of Alkaline rust converting primer on alround bars new & old as recommended by the manufactuer (iii) Apply two coats of Epoxy phenolic anti corrosive protective coat on bars alround new & old as recommended by the manufactuer. Note : Anti corrosive treatment shall be continuous espcially in the regions where pitting, imperfections, etc were present on the surface of the bars. It is important that the rear portions of re bars (those towards the concrete substrate) should not be left without coating.
M&L for providing PMM (Polymer modified cementitious mortar) :- (i) Dry sub strate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound substrate using approved spray machine & ensuring that no pin holes are visible.(In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above apply PMM of 30 thick Note:- Application of PMM shall be preferably be in coats of appx 10mm thickness. PMM work shall be executed in fairely rapid successions so as entire work is completed with in 30 mins). PMM shall be pre packed ready to use. (iv) PMM surface to be moist cured for three days followed by air curing in temperature as recommended by manufactuer complete all as specified and directed.
M&L for Drilling & chemical anchoring of new rebars/stirrups :- (i) Drilling in to the sound RCC members for anchoring of rebars/stirrups as directed, the dia of hole to be match with dia of rebar & length of drilling as under :- 10-12 mm dia bar - drilling length 80 to 100 mm Note : Anchoring of new re-bars of any dia as directed in to the sound RCC members as directed using pure epoxy resin anchoring mortar with appropriate diameter of drilling of holes as mentioned above for proper bonding into the concrete etc., complete all as specified and directed. Note:- The cost of drilling hole & chemical anchoring with epoxy resin is inclueded in this item
M&L for use & waste of form work using steel sheets, steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note:- Form work shall be 100% leak proof. For purpose of payment area in touch with concrete shall be measured.
M&L for Providing & Pouring Micro concreting M-40 grade :- (i) Dry concrete substrate surface and free of debris & dust (ii) Applying Epoxy bond coat on the sound concrete substrate using approved spray machine & ensuring that no pin holes are visible. (In case pin holes are still visible after a coat, a second coat shall be applied to ensure absence of pin holes). (iii) Immediately after application of epoxy bond coat as above pour Micro concreting M40 grade, Make : MasterEmaco S46T of BASF or equivalent FOSROC/SIKA using approved mixing machines/pumping under pressure via approved pneumatic pump at the locations to be repaired in RCC beams & columns etc,. Adding of aggregates will be permitted only as per manufacturer’s recommendation without compromising the strength. The rate shall include cost of all materials (except re-bar) labour charges for mixing, pouring concrete, cost of tools, lead & lift of materials, transportation etc., to carry out the complete work complete all as specified and directed including M&L for use & waste of form work using steel sheets , steel bracing, propping etc around structural members where micro concreting to be done and keeping form work in position till required specified period complete all as specified and directed. Note : Form work shall be 100% leak proof. The cost of micro concrete M-40 grade & Epoxy bond coat is inclueded in this item.
S&F for stengthening existing reinforcement by use of mild steel bars of any dia , cut to length, bent to shape required, including cranking, bending spirally and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking up or down steel water tubing and connections 15mm bore pipe complete all as specified and directed.
Taking up or down steel water tubing and connections 20mm bore pipe complete all as specified and directed.
Supply, laying and fixing of 20mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc suitable for 15mm bore bath fittings). (Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings).
Supply and laying of 25mm outer dia of CPVC pipe SDR 11 and plain CPVC SDR 11 fittings on wall/ceiling or laying in floors complete including brass CPVC fittings (i.e elbow, Tee, MTA/MBTA,FTA/FBTA, Tank adaptor, Union, etc). (Note- length of pipe with fittings to be measured for payment, no extra payment should be made for fittings).
Dismantling PVC water tanks of capacity exc 500 Ltrs but n.exc 1000 Ltrs from roof all as specified and directed .
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 1000 litres capacity,White in colour, ISI marked, double layered hoisted and fixed in position including connecting up pipes all as specified and directed.
S&Fin repair 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete.
S & F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic wall, screwed for iron pipe and fixed for 25 mm bore size (Minimum weight 210gms), complete.
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, shelves, lintels, etc, and cutting chases for concealed water tubings or conduit wiring, etc and making good, cutting not exceeding 10cm girth complete.
S&F in repair 150x100 mm Salt glazed stoneware gully traps, square or rounded mouthed type 'P' , with CI grating including jointing with solvent cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in bed all as specified and as directed.
Dismantling of 150mm bore reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required.
M&L for Cement concrete type D-2, 1:4:8 (using 40mm graded stone aggregate) in foundations filling and mass concrete complete all as specified by Engineer-in-Charge
M&L for 150mm bore DWCPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions and complete all as specified and directed by Engr-in-Charge.
Cutting into existing manholes for connecting 150mm dia of pie to new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required.
M&L for precast factory made manhole cover, area of each cover .n.exc. 1.00sqm, 100mm thick with SFRC concreting including groove and hook arrangement for lifting and placing in position and sides covred by MS sheet complete all as specified and directed.
M&L Water proofing treatment walls of bathroom consisting of the following operations including demolition or taking down old treatment:- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) Filling of all brick joints with cement mortar 1:4 (iii) Applying a coat of Chemical Dr fixit Pidifin 2K (iv) applying fiber mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, plaster the surface with CM 1:4 15 mm thick. (Note All water proofing treatment will be executed by the authorised representative of Dr fixit).
M&L Water proofing treatment on sunken floor consisting of the following operations including demolition or taking down old treatment:- (i) Cleaning of surfaces by wire brushing brooming removing dust particles (ii) M & L PCC 1:2:4 type (Bo) using 12.5 mm graded stone aggregate 50 mm thick, finishing the surface even and smooth without using extra cement (iii) Applying a coat of Chemical Dr fixit Pidifin 2K (iv) applying fibre mesh setting with chemical Dr fixit Pidicrete URP (v) final coating with Pidifin 2K and sprinking of sand (vi) After the surface dried, screeding the surface with CM 1:4 15 mm thick including finishing even and smooth using extra cement. (Note All water proofing treatment will be executed by the authorised representative of Dr fixit).
M&L for broken lean concrete 1:5:10 with broken brick aggregate in sunken of gauge n exc 63mm deposited spread and levelled in layers n exc 15 cm thick hand rammed to a true surface
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 75mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete..
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore including demolition/taking down PVC/CI drain/Rain water pipe complete.
S&F PVC (SWR) Branch piece, double (double Y) equal or unequal with access door of 75mm bore complete.
S&F PVC (SWR) Branch piece, double (double Y) equal or unequal with access door of 110mm bore complete.
S&F PVC (SWR) vent cowl, 75 mm bore complete.
S&F PVC (SWR) bends with access door any radius, 75 mm bore, complete.
S&F PVC (SWR) bends with access door any radius, 110 mm bore, complete.
S&F PVC (SWR) junction single (single T), equal or unequal, with access door 75 mm bore, complete.
S&F PVC (SWR) junction single (double T), equal or unequal, with access door 110 mm bore, complete.
S & F Soap dish disc (oval) type, stainless steel chromium plated of approximate size 100 x 50 x 10 mm, complete.
S & F sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass self 12 cm wide with chromium plated bracket guard and railing 60 cm long.
S&F in repair 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate mix with WPC complete all as specified and as directed.
S & F Tubular towel rail of brass chromium plated, 20 mm dia, 'D' type, 60 cm long between flanges complete.
S & F in repair Pillar taps fancy type,cast copper alloy, with capstan heads,chromium plated,screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts,screwed for iron pipe and fixed 15 mm bore complete.
S & F in repair Bib taps cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore complete.
S & F repair Brass CP mixer for mixing hot & cold water screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe 15 mm bore for WHB complete.
S & F in repair Brass chromium plated shower rose 12.5 mm size with swivel joints, wall flange complete.
S&F Toilet paper holder with flat recessed type stainless steel Complete all as specified and directed.
S&F in repair vitreous china squatting pan, ‘Orissa’ pattern, of size 580 mm x 440 mm white with integral foot rest complete including provn of cement concrete bedding and connection to trap, outgoing flushing pipe, anti syphonage pipe etc complete. Make Cera/Jaquar/Kohler
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed along with Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
Supply only EWC Seat cover black/white colour of PVC closed pattern with flat bottom and mild steel lchromium plated or aluminised hinging device complete all as specified and directed. Make Cera/Jaquar/Kohler
S&F 10 litre capacity PVC low level flushing cistern white with inlet, float valve including bracket with 32mm dia PVC waste/flush bend pipe appx 600 mm long complete.
S & F in repair PVC connection 600mm long and15 mm dia with brass fly nut at both ends complete.
S&F 600mm long hot water connection for Geyser Hose Pipe or nozel with pipe for Hot an Cold Pillar tap mixer all as specifed and directed
S&F in repairs oval wash hand basin white, flat bottom including waste fitting 32mm dia brass chromium plated coupling with long screwed shanks and fly nuts flange end bedded in red lead coment and other end fixed complete all as specified and directed.
S&F in repair vitreous China half stall urinals, complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing automatic flushing cistern with brackets flush pipe, grating and Union for discharge pipe, including connections to flushing pipe and outgoing pipes fixed in repairs.
S&F 32 mm dia bore Low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to walls,ceilings or in floors etc for WHB and sink complete.
S&F in repair Chromium plated brass stop or angle valve concelled type for 15mm bore pipe, fixed in repairs complete all as specified and directed.
Taking down chowkhats or frames n.exc 1.50 sqm with shutters (without taking off shutters from the frames) all as specified and directed.
Taking down chowkhats of frames exc 1.50 sqm but n. exc 4.0 sqm with shutters (without taking off shutters from the frames) all as specified and directed.
Taking down shutters of any description area of each shutter n.exc 2.00 Sqm each and refixing in same opening after easing and adjusting (Note consumable item to measured in respective items)
S&F double rebated,Pressed steel frames of size 60 x 125mm for doors including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified,supplied and fixed.
S&F Flush shutters 30-35 mm thick, solid core construction, with block board core and ply wood face panels, commercial type on both sides with leaping and beading complete.
S&F 35 mm thick second class hardwood glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered beads for securing glass/ gauge complete all as specified in SSR Pt I-1991 section 8 clause 8.24 (a) and as directed.
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with stainless steel wire staples beads, tinned tacks to wooden doors shutters complete.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete.
S&F Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
S&F of door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge
S & F Roll Forming GI ECO 4000 series double shutter (glazed shutter and mesh shutters) galvanized steel windows and ventilators with guard bars, fabricated from roll formed sections made galvanized steel colour coated/powder coated sections including 4mm thick plain glass pan in glazing for glazed shutter and stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.4mm complete for mesh shutters, including two coat of synthetic enamel paint over a coat of red oxide on steel guard bar , all fitting and fixtures all as specified.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Plain Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural Fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with density not less than 650 kg/cbm Certified Company, having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compressive Strength of 50 N/mm2, Modulus of elasticity 850N/mm2 and resistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof, Fire Retardant and fixing with stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen & Cabinets.
S&F Factory Made 18mm thick 100% Solid WPC ( Wood polymer Composite ) Laminated Board of required size comprising of virgin PVC resin of K Value 57-60 ( Suspension Grade ), Calcium Carbonate and natural fibers ( Wood Powders/ rice husk/ wheat husk ) and Non toxic additives, made from Extrusion process WPC foam sheet Single Extruded ( Inner ) with having minimum density not less than 650 kg/cbm having good screw holding capacity ( Screw Withdrawal strength of 2000 N ( Face ) & 1100 N ( Edge ), Minimum Compissive of 50 N/mm2 , Modulus of elasticity 850N/mm2 and esistance of spread of flame of Class A category with Property of being Termite/ Borer Free.Water/ Moisture Proof and Fire Retardant. WPC to be Laminated with PVC foil of minimum 14 microns thick of approved design pasted on both faces of shutter and fixinng stainless Steel butt hinges of required size with necessary full body threaded star headed counter sunk SS Screws. All as per direction of Engineer -In-Charge, Material test certificate and authentication should be compulsory provided by the manufacturing company : For WC/Bathroom/Toilet/Kitchen and Cabinets.
S&F in repair stainless steel 1mm thick sinks with drainage board made of kitchen or laboratory with plugs, washers and wastes, including bedding in cement mortar including fixing cantilever brackets connecting union to pipe and 32mm dia GI pipe duly painted upto Nihani Trap or Floor trap complete as directed at site, overall size 915mmx460mm bowl size 410mm x 330mm x160mm. all as specified.
S&F 100mm long, extruded fancy type SS handle for kitchen cup boards shutters, cabinets, crocery shelf drawers fixed with nuts , screw and washer of mild steel bright finished , complte all as specified.
S&F Continuous (piano) hinges,mild steel, bright finish or electrogalvanised,Widthof flaps 40mm(when open).
S&F 75 mm long L Bihari concealed type hydrauilc hinges incl stainless screw complete all as specified.
Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165.
S&F 150 mm long Stainless Steel barrel tower bolt with screws complete
S&F 200 mm long Stainless Steel barrel tower bolts with serews complete
S&F Stainless Steel butt hinges, 100 mm size medium weight, complete
S&F stainless steel handles 150 mm size cast type, complete
S&F stainless steel, sliding door bolts 300mm long with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate.
S&F Stainless Steel Cromium Plated tubing of 25 mm dia curtain rod fancy type including fancy type CP brabs brackets (wall to wall or flush to wall) with finials or end caps decorative type as approved by GE for securing to curtain rod to wall in position, fixed in repair complete.
M&L applying two coats of synthetic enamel paint on new steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
M&L cutting crack to 'V' groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed.
M&L for APP based polymeric membrane plain finish minimum weighting 3 kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt not less than 150 gms/sqm) over one coat of 85/25 bitumen @1.2 kg/sqm and paste the membrane with torching method and again apply a coat of 85/25 bitumen @ 1.2 kg/sqm at overlapping joints include 15 mm thick screed bed in CM (1:6).
M&L for cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as specified and directed. (Rate of WPC shall be included in unit rate)
S & F for Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface up to 3 cuts complete, including providing skirting up to 150 mm height along the parapet walls in the same manner incl 15 mm thick screed bed in 1:6.
M&L for Preparing new plastered surfaces of wall and providing and applying plaster of Paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth and finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified as directed by Engr-in-charge.
M&L for 100mm thick type-D-2 1:4:8 (using 40mm graded stone aggregate) as in sub base to receive paver blocks all as specified and directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete.
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc for taking credit including making good the disturbed surfaces to match with the existing, complete all as specified and directed.
M&L for point wiring with 1.5 Sq.mm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLSH electrolytic copper conductor cable confirming to IS 694:2010 with and including continuous earth wire of size 1.5 Sqmm (nominal size) single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH electrolytic copper conductor cable and connected to earth dolly, colour coded as per IS 11353: 1985 drawan through and including rigid non-metallic PVC concealed conduit of 20mm dia (Nominal bore) or higher, medium grade confirming to IS 9537(Part 3): 1983 complete with and including all PVC conduit accessories and factory made not less than 1.2 mm thick sunken modular flush sheet galvanised metal enclosure having zinc coating not less than 120 GSM confirming to IS 14772 : 2000 having op, bottom, side and back-wall knockouts for conduit entry from any direction, suitable modular cover plate with frame and making good of disturbed surfaces of wall/ceiling/floor etc complete all as specified in IS 732: 2019 and directed by Engr-in-Charge, for One light / bell point controlled by one, one way switch 06 Amps, complete all as specified and directed.
All as per item No 127 here-in-before but for one light point controlled by two way switches
All as per item No 127 here-in-before but one Ceiling / exhaust fan point controlled by one, one way switch 5/6 Amps
All as per item No 127 here-in-before but one 3 pin, 5/6 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per item No 127 here-in-before but with point wiring 2.5 Sqmm single core FRLS cables and earth continuity wire of 2.5 Sqmm single core FRLS cable for one 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch but not below the switch board of light points in the same vertical plane.
All as per item Srl item No.127 here-in-before but point wiring with 4 Sqmm (Nominal size) single core FRLSH cables and earth continuity wire of 4 Sq mm (Nominal size) single core FRLSH cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete
S&F modular switch, 06 Amps, single pole, one way, 230 volts, one module and IP 20 protection complete all as specified & directed
S&F switch modular 2 way switch 6 Amp, 230 Volt,suitable for one module complete all as specified and directed by Engineer -in-Charge.
S&F modular switch, with indicator, 16 Amps, single pole, one way, 230 volts complete
S&F modular socket outlet 03 Pin, 06 Amps, 02 module with shutter complete
S&F modular socket outlet 02 in 01, 03 pin, 6/16 Amps, 02 module with shutter complete
S&F ceiling rose, 6 Amps, 230 volts, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F surface/wall mounting LED batten luminaire with System Power : 20W, Length : 4ft,Housing : Epoxy powder coated white extruded aluminium channel, Diffuser : Milky white Polycarbonate, Rated Voltage : 240V, Safe operating Voltage : 140V to 270V,Rated Frequecy : 50 Hz,Power Factor : ≥ 0.95,THD : ≤ 10,Operating Temp : - 10 deg C to + 45 deg C, Lumen Efficacy of LED : ≥ 120 Lm/W,System Luminous Efficacy : ≥ 100 Lm/W, CRI : ≥ 80, CCT : 5700K, Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV, IP rating : 20 and IK rating : 03 complete all as specified and as directed.
S&F surface/wall mounting LED batten luminaire with System Power : 10W, Length : 2ft,Housing : Epoxy powder coated white extruded aluminium channel, Diffuser : Milky white Polycarbonate, Rated Voltage : 240V, Safe operating Voltage : 140V to 270V,Rated Frequecy : 50 Hz,Power Factor : ≥ 0.95,THD : ≤ 10,Operating Temp : - 10 deg C to + 45 deg C, Lumen Efficacy of LED : ≥ 120 Lm/W,System Luminous Efficacy : ≥ 90 Lm/W, CRI : ≥ 80, CCT : 4000K, Driver : Integral SMPS based constant current type with short circuit , surge voltage protection upto 2.5 KV, IP rating : 20 and IK rating : 03 complete all as specified and as directed.
S&F surface mounted LED building security light fitting in high pressure die cast aluminium housing polycarbonate deffuser not less than 45 watt fixture should have minimum efficiency at level >=120lumens/watt, life of fixture not less than 50K Hrs, Ripple<5%, UGR<19, Minimum surge protection level of 2.5 KV, CCT 6500K with same lumens/w CRI>80, PF>0.95, THD<10%@240V AC, an operating voltage range of 140-270V including light grade GI tube mounting size 40MM bracket of suitable size & length, bend to shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete and one coat of primer and one coat of synthetic enamel paint after coating of primer on GI bracket and pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core including T/D of old UNSV and depositing in MES store yard complete all as specified and as directed.
Supply and fixing of exhaust fan double ball bearing ,heavy duty motor , noise level 45-50 dB, steel body, AC, single phase,48 Watt 230 V of size 300mm sweep with blades, frame & protective steel bird guard having 1370 RPM speed,air delievery 1160 CMH with and including making of hole of suitable size, taking down old exhaust fan PVC to deposit in MES store yard and making good to the disturbed surfaces to match with the existing complete all as specified and as directed.
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 230 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete all as directed by Engineer - in - charge.
S & F 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 220 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block to ceiling rose and taking down old ceiling fan depositing in MES store complete all as specified and directed.
M&L for sub main wiring with 4 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable with and including continuous earth wire of size 4 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLSH copper conductor cable drawing into and including rigid non-metallic PVC concealed conduit of suitable dia, medium grade with all conduit accessories and connected to common earth dolly with suitable copper lugs including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing including taking down old sub main wiring complete. (Note : 3 Run of single core wire and 1 run of conduit shall be measured and paid as 1 unit), complete all as specified and directed.
All as per Srl item No.145 above but for 02 x 10 Sqmm for phase & neutral and 01 x 10 Sqmm for continuous earth wire
Supply and fix electric water heater, storage type 25 ltrs capacity, BEE star rated, vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adapter for inlet and outlet water connection, copper element corrosion resistance antiscaling magnesium anode having adustable knobe for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure having heating element 2 KW and minium two year warranty on product, minimum three years on heating element complete all as specified and as directed .
S&F in replacement sheet metal enclosure distribution board confirming to IEC- 61439-3, single pole and neutral, AC, 240 volts,8 way, with 100 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete. ( Note :- MCB and DB shall be of same make), complete all as specified and directed.
S&F in replacement sheet metal enclosure distribution board confirming to IEC- 61439-3, single pole and neutral, AC, 240 volts,12 way, with 100 Amps rated copper bus bar and metal double door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete. ( Note :- MCB and DB shall be of same make), complete all as specified and directed.
S&F in replacement sheet metal enclosure distribution board Vertical triple pole and neutral (VTPN), AC, 440 volts, 04 ways with minimum 200 Amps rated copper bus bar for each phase, 2 neutral bar, 2 earth bar and cable ties metal door with IP 43 & IK 09 protection confirming to IEC 61439-3, along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed suitable for 4-pole MCCB as incomer & MCB SP as outgoing having rating as per load requirement
S&F MCCB 125 amps, 4 Pole, 415 volt, AC, fixed type, with breaking capacity 16 KA suitable for load line/ VTPN DB & connection complete
S&F of MCB confirming to ISI/IEC- 60898-1(2002), SP, AC, 240 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs , complete all as specified and directed.
S&F of MCB confirming to ISI/IEC- 60898-1(2002), SP, AC, 240 volts of 40 to 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs , complete all as specified and directed.
S&F of MCB confirming to ISI/IEC- 60898-1(2002), SPN, AC, 240 volts of 40 to 63 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs, complete all as specified and directed.
S&F in replacement industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 230 volts of 32 Amps, 'C' curve 10 KA breaking capacity and flush to wall/ surface as per site conditions including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing, complete all as specified and directed.
Supply and fixing wall mounted flexible type study cum bed lamp LED luminaire 8 watt deep recessed aluminium housing stainless steel screws diffuser corossion & UV ray resistant coating complete all as pecified and as directed by Engr in Charge.
Supply and fixing wall mounted fan of 400 mm sweep, 230 volts, AC, 50 Hz capacity, including all arrangements for mounting of fan including connecting up with provision of PVC insulated flexible twisted type copper conductor cable 1.5 Sqmm, 2 core as required for connections complete all as pecified and as directed.
Supply and laying or fixing or passing through pipe in repair of 1100V grade, heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed of size 50 sqmm 3.5 core nominal cross section complete
Excavation in trenches not exc 1.5 Mtr wide and n.exc 1.5 mtr in depth, getting out in loose/soft soil for laying of cable complete all as specified & directed
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed
Sub class ‘B bricks, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and as directed
Sand cushioning to under ground cable with a layer of sand 8 cm before laying the cable and 15cm after laying the cable (10 cm punned thickness above the top of the upper most cable, total 18 cm), complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick directly buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below the ground level connected to GI wire 4 mmdia by means of bolts nuts check nuts and washers of galvanised iron at 2 points & GI pipe 15 mm bore light grade for protection of earthing strip, 20 mm bore light grade GI pipe for watering, PCC chamber 1:3:6 (type C-1) using 20mm graded stone aggregate, watering pipe 20 mm bore light grade, funnel with wire mesh, 50 mm thick cover of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with 8 mm MS bars at 150 mm centre to centre both ways and charcoal dust and common salt all as shown in electrical plate No. 3 of MES SSR part-I and including excavation & earth work & connecting the earthing point / equipment and testing complete (Note :- Testing will be carried out in presence Engr-in-Charge)
shiva enterprises (BID ID -3507549)
QUALITY CONSTRUCTIONS CO (BID ID -3508567)
J.P. Enterprises (BID ID -3502491)
MINHAS CONSTRUCTIONS (BID ID -3502055)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tenderdoucmentd77.pdf
Tender Documents • 1.46 MB
BOQ_829631.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .