Loading…
Loading…
Tender Value
₹3.0 Cr
EMD Value
₹5.9 L
Closing Date
12 Aug 2026, 3:00 pm
Interlocking of 03 nos.LC gates viz. RM/252, RM/255, RM/318 with associated works of Tinsukia division in N.F. Railway
N-2026-27-TSK-T-05
N-2026-27-TSK-T-05
Open
Works - General
180 Days
Tinsukia, Assam
₹0
₹5.9 L
20 Jul 2026
20 Jul 2026
29 Jul 2026
Item Breakup - A-Supply items
Red Main Signal aspect
Yellow Signal aspect
Green Signal aspect Total 869480.00 Supply and installation of Electronic LC gate telephone systems with voice recorder as per RDSO Item- 40 SPEC.NO.RDSO/SPN/TC/51-2021 rev 1.0 or latest. Material to be supplied from RDSO's. approved source only with 03(three) years full warranty Inspection- RDSO S No. Item Description of Item Unit Qty Rate Amount No
Master telephone with voice recording facility TINSUKIA DIVISION-S AND T/N F RLY
Gate (slave) telephone with surge protection and Numbers line connection unit
Power supply 24V unit with MF Battery and Charger Numbers unit with inbuilt battery Total 364124.40
Supply of 3 Aspect signal unit in FRP body without lense & transformer as per RDSO 1 specification no. RDSO/SPN/194/2006,Version-1 or latest and drawing No.SA-23002A/M (Adv) or latest, Silver pigment finish on back side of door & inside of signal unit white pigment finish to avoid any extra paint cost. Inspection- RITES
Supply of 2 Aspect signal unit in FRP body without lense & transformer as per RDSO 2 specification no. RDSO/SPN/194/2006,Version-1 or latest and drawing No.SA-23003A/M (Adv) or latest, Silver pigment finish on back side of door & inside of signal unit white pigment finish to avoid any extra paint cost. Inspection-RITES
Supply of CLS base 140mm dia tube (Drg no. 2011/M, Tubular steel post 3.6 mtr (IRS:S-6/81), ladder assembly complete with background platform & ladder base (Drg.no.SA-23150), Anchor bolt (4nos) with nuts & washers as per RDSO Drg.no.SA-115A/M or latest. Inspection-RITES
Supply of Electrically operated lifting barrier complete set as per specification no. IRS:S-41/70 (Amdt-2 and RDSO/SPN/208/2012 (Ver 2.0) or latest 110 V AC with G.I. boom, hand generator & motorized locking arrangement. Inspection-RDSO
Q-Series Line Relay (QNAI Type), AC immunized, 8F/8B, 24 V DC along with plug 5 board (base plate), connectors, retaining clips. etc. and conforming toBRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH Inspection-RDSO
LED ECR , 110V AC, conforming to RDSO specification no. STS/E/Relays/AC lit LED signal/09-2002 Inspection-RDSO
Supply of LED signal lamps for Main color light Signal, 110V AC retrofittable in 8 existing CLS housing and compatible with AC LED ECR as per RDSO Speen. No. RDSO/SPN/199/2010(Rev.1) RDSO/SPN/199/2025 Rev 1.2 with Amendment 1, or latest. Inspection- RDSO
Supply of 16/0.2mm size tinned flexible single core indoor wire IRS : S- 76/89 Amend. No. 2 or with latest amendment/specification, PVC coated in different colours as per technical specifications and to be supplied in coils of 100 meters. Inspection-RDSO
Disconnect Terminal block for Four conductor with screwless Cage Clamp type/sliding 10 switch disconnect as per RDSO Specification No. RDSO/SPN/189/2004 version 1.2, for each conductor size upto 2.5 sq. mm. Equivalent of M6 Terminals. Each Terminal block equipped with two markers on top and bottom, an end plate, 2 end clamps & adequate length rails for fitting terminal blocks. Inspection-RDSO
ARA terminal block 6 Way, PBT, as per IRS:S75/2006, Drg. No.SA-23756. Inspection- RDSO
Apparatus case large, as per RDSO Drg. No. RDSO/S/11500 with latest amendments. Inspection-RITES
Electrical Key Transmitter, rotary type, as per IRS: S-76/89 Amend. 22601(Alt-4) or latest. Inspection-RITES
Supply of Power wire (copper, multi strand) (1x25Sq.mm) as per technical specification. Inspection-Consignee
PVC insulated multistrand flexible Power wire of 10 sq.mm (140/0.30mm). Inspection- Consignee
Supply of Dual Tone Bell/Buzzer with Flasher arrangement and 25- Watt horn and 15 watt amplifier working on 24 V DC 110 V AC for warning road users at LC gates Inspection-Consignee
Relay fail safe electronic timer conforming to IRS:S- 61/2000with Amend. No. 1 or with latest amendment/specification asper TS. Inspection-RDSO 1037922.1
Supply, Installation & Commissioning of SMPS based IPS system conforming to Specification no: RDSO/SPN/165/2023 Version 4.0 with Amendment I or latest and Drg. No. 18 Annexure-III or latest (For LC Gate/IBH/RH) along with 110 V 200 AH Low Maintenance cells/VRLA Maintenance Free cells secondary Cell as per IRS:S-88/2004 Ver. 1.0 with battery rack, SPDS. Tools kit, Charging of batteries with supply of Electrolyte, Installation, testing and commissioning, configuration of different modules of IPS for working of signaling System for interlocked DETAILS OF STANDARD MODULES TO BE USED as per ANNEXURE-IIIA RDSO Specification No. of RDSO/SPN/165/2023 (Ver.4.0) Amdt. 1 or latest Inspection-RDSO
Fuse block made of PBT IRS:S-75/2006, Drg.no. SA-23748,Alt-4 or latest. Inspection- RDSO
NDT fuse 2Amp IRS:S-78/92 or latest. Inspection-RDSO
Supply of Power wire (copper, multi strand) (1x35Sq.mm) as per technical specification. Inspection-Consignee
U/G signalling cable conforming to specification no IRS spec. no S- 63/2014, Rev 4), 12 core x 1.5 sq.mm. Copper conductor. Inspection-RDSO
U/G signalling cable conforming to specification no IRS spec. no S- 63/2014,Amdt-1 or latest) 2 core x 25 sq.mm. Aluminium conductor. Inspection-RDSO
Supply of 6 Quad cable, 0.9mm dia. Copper conductor, as per specification No. IRS:TC-30/2005 (ver.1)Amdt-1 to 5 or latest. Inspection-RDSO
Supply of Micro Processor based Remote Terminal Unit (RTU) with 128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest. It includes supply of all the items required for complete indoor relay room wiring from RTU to relay rack tag blocks, 25 drawing/extension of power supply up to RTU. It includes supply of relay room door lock checking arrangement, commercial power supply monitoring arrangement & monitoring of DG sets, ELD (if installed), IPS, other Potential free contacts as per instruction of Railway Representative, interlinking and networking of RTU. It also includes supply of leased line MODEM, suitable online UPS (minimum 6 hours" backup) and other interfacing cards, if required for networking of Data Logger. Inspection- RDSO
Supply of service terminal for management and data application as per technical specification. Inspection-Consignee
Supply & Erection of Relay rack, frame, scaffolding and ladder/angle for relay room, power equipment room, batteries room and other places as required, all oven baked and powder 27 coated with Biscuit Mat colour corrosive resistant and final finish with Siemens Grey (Sigma) enamelled paint, complete as per drawing No. Drg No. CSTE/ with Insulators, grouting bolts, tripods, rack fittings, ladder arrangement and all necessary fitting, supports, insulators, string rods to support cable, and other accessories etc. Inspection-Consignee
Supply & Erection of Cable Termination rack, frame, scaffolding/ladder/angle, all oven baked and powder coated with Biscuit mat colour corrosive resistant and final finish with Siemens Grey (Sigma) enamelled paint, complete as per drawing No. Drg No. CSTE/ with Insulators, grouting 28 bolts, tripods, rack fittings, ladder arrangement, hylam sheet board of 10 mm thickness covering complete rack, all necessary fitting, supports, insulators, string rods to support cable, and other accessories etc. as per drawing and technical specifications & Erection with scaffolding arrangement, fixing of tag blocks and all types of terminals on cable termination racks as per technical specifications. Installation-Consignee
Supply, Fabrication and Fixing of Retro reflective Signal Number Plate of standard 29 size and drawing as per SEM, high intensity prismatic (hip) grade retro reflective sheet (TYPE-IV) including fixing arrangement for fixing them on existing posts as per standard practice. Inspection- Consignee
Supply of Earth electrode for outdoor equipment consisting of 2.5 meter G.I. Pipe medium grade having internal dia of above 38 mm GI pipe shall consist of spike at one end and a lug at the other for connecting the earth lead wire. Inspection-Consignee
MS strap 50x6 mm for earthing of location boxes for peripheral earth. Inspection- Consignee
One set of different type of panel key for domino type control cum indication panel. Make- Deltron/Ultra/Similar. Inspection-Consignee
Supply of CO2 type fire extinguisher capacity 4.5 Kg capacity ISI Mark IS: 15683 operating temperature (-30) to (50) for class 13 B type of fire with 1 mtr. Hose pipe fitted with PVC bend hom complete in all respect. Inspection-Consignee Square
Supply of High intensity grade retro-reflective sheet as per railway specification IS:736 (Color Yellow/RED) Inspection-Consignee
Supply of sliding boom for LC gates as per technical specification. inspection- Consignee
Supply of 25 kV RE compatible Tools as per technical specification. Inspection- Consignee
Supply of V.F. transformer 1220:600/470/:1220 as per IRS:TC-22/76 or latest Inspection-Consignee
Supply of DLP trunk 32X20mm with required all changeable internal/external angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or Similar Inspection-Consignee
Supply and installation of Electronic LC gate telephone systems with voice recorder as per RDSO SPEC.NO.RDSO/SPN/TC/51-2021 rev 1.0 or latest. Material to be supplied from RDSO's. approved source only with 03(three) years full warranty Inspection- RDSO
Hylam Sheet, resinbonded,10mm thick,grade-P3, in standardsize of 1.22mX1.22m asper spec IS2036 of 1974. Inspection-Consignee
Supply of HDPE DWC pipe of size 90/76 mm dia nominal as per RDSO Specification 42 No. RDSO/SPN/204/2011 version 1.1 Amd. 1 or latest TEC specification No. with Anti Rodent and Anti-flammable property along with socket, coupler etc. - as per technical specification and as approved by Engineer-in-charge Inspection-Consignee
Supply and installation of Goods Warning Board as per Drg. No. SA 2380(ADV) or 43 latest with retro- reflective Strips/reflective paper, making foundation as per latest drawing of CSTE/NFR complete with contractor material including angle for erection, supply and painting the board & post as per approved colour scheme complete installation as per Technical specifications. Inspection-Consignee
Fabrication, supply and fixing of P, C, A, G, R, AG etc. marker disk painted and 44 lettered with enameled paint of approved colours, on signals, conforming to RDSO Drg. No.SA- 23456, as per standard practice and technical specifications, with contractor's complete material including fixing clamps. Inspection-Consignee
B-Execution of work
Installation, wiring, testing and commissioning of electrically operated lifting barrier, 45 complete with Casting of cement concrete foundation (including supply of sand, stone, cement, bolt, plate etc.) for pedestal and boom rest post, cabling, power supply connection & wiring with complete outdoor work as per approved drawing, wiring etc.
Excavation, ramming, Casting Cement Concrete foundation for Colour Light Main Signal Post in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, as per approved drawing supplied by railway and technical specifications.
Assembling, erection, installation of 3-aspect signal complete. This includes taking of 47 cable inside unit through post, termination and wiring of CLS complete with all accessories of CLS unit, post, base, ladder, ladder guards, platform and MS supporting bracket in the middle of the ladder, hoods as per Technical specification.
Assembling, erection, installation of 2-aspect signal complete. This includes taking of 48 cable inside unit through post, termination and wiring of CLS complete with all accessories of CLS unit, post, base, ladder, ladder guards, platform and MS supporting bracket in the middle of the ladder, hoods as per Technical specification.
Excavation, ramming, Casting Cement Concrete foundation for Apparatus cases (Full) in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, as per Drg. No. CSTE's Drg. No. and technical specifications using standard size galvanized Anchor bolts
Installation of Apparatus cases/Location Boxes on CC foundation on grouted bolts, including filling the space enclosed below the location box with contractor's sand, as per technical specifications including suplly and fixing of hylumsheet as per ts(size 10mm thick).
Installation of 'EKT' in gate goomty and wiring with gate, etc as per Technical specifications
Supply and installation of maintenance free Earthing as per code of practice RDSO/SPN/197/2008 or latest. Inspection-Consignee
Installation, wiring, testing & commissioning of Micro Processor based Remote Terminal Unit (RTU) with 64/128 digital input & 16 analog input as per RDSO Spec. No. IRS (S) 99/2006 with Amdt. 3.0 or latest as per TS
Taking the all types of cables inside station relay rooms, ASM's room, location huts etc. and sealing of cable entry pit as per Technical specifications, complete with contractors' material.
Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not exceeding 3 : 8 cm including excavation, ramming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate etc.
Excavation and refilling of trenches in all types of soils as per technical specification.
All works of excavation of cable trench on pucca platform/on Road for road crossing and restoration of the platform/Road surface to original condition with contractor's material, after laying of GI/DWC pipes and then re-fill.
Excavation and refilling of cable trench for track crossing as per technical specifications.
Laying of underground signaling cables in trench as per technical specifications.
Installation of power supply arrangement including supply of Power panel board, 60 controlling switch, voltmeter, ammeter and all electrical wiring/interconnection of , inverter, Battery & charger, conveter, transformer etc. as per technical specification. Carrying of power equipments shall be done at contractors own cost. Location
Termination of cables and supporting of string rod with supply and providing identification tag/ferules/tapes with
Installation of Earth electrode for outdoor equipment as per technical specifications. Note: Installation of earth electrode includes the construction of the surrounding earth pit using contractor's own material
Fixing of GI pipes/DWC pipes of all sizes & diameters/ troughing on culverts, bridges & any other loc. etc. complete as per technical specifications. 1725375.9
Alteration/modification of existing EI as per TS
Preparation and supply of laminated one set of all completion drawings including circuit diagrams, PD, RCC, SIP and documents as per the technical specifications, for keeping at each station.
Complete painting, varnishing, lettering, numbering of all gears at LC Gate as per SEM and instruction of Railway Engineer at site with contractor's own primer, paints, varnish etc. of Asian/Shalimar/Berger make paints and as per technical specifications as per TS
Installation of Sliding type LC gate on concrete foundation with complete wiring as per technical specification. It includes (i) Excavation, ramming, casting cement concrete foundation (Ten numbers per LC gate) for sliding gate complete set as per CSTE's drg no. SK/21/00072 or latest with contractor's materials including cement, sand, stones, aggregate, etc (ii) Installation of sliding 67 gate and boom rest post along with 'E' type locks and lock up box as per CSTE's drg no. SK/21/00072 & PCSTE's drg No. SK/20/00063 and technical specifications. Necessary grouting bolts of appropriate size as directed by the supervisor in charge (40 nos per LCG) with nuts & washers etc. to be supplied by contractor. (iii) Installation of EKT on Hylum sheet and its wirings in connection with alteration, modification in existing circuit at LC gate as per instructions of Railway site supervisor. This also includes supply & fixing of Hylum Sheet, MS angles push button, LED indication for each EKT as per direction of Railway supervisor in Charge. All required consumable materials except EKT and wires to be supplied by contractor.
Carrying of slidding boom for S&T workshop/PNO to Consignee's godown and loading/unloading the same at works site as per technical specification.
Testing and commissioning of complete signalling installation at LC Gates as per TS
Dismantling and Deposit of released S&T gears from work site to Railway godown as per technical specification.
HDD boring as per technical specification. This includes transportation of HDT machine with accessories to site, preparation of site, boring and placing of HDPE pipe/Pulling of cable etc. Cost of fuel and all other accessories to be borned by the contractor.110 mm dia boring
Installation of V.F. transformer 1220:600/470 /:1220 as per IRS:TC- 22/76 or latest
Fixing & wiring (Laying) of DLP trunk 32X20mm with required all changeable 73 internal/external angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or Similar. Cable will be supplied by Railway and all other fixing material will be supplied by contractor.
Jointing of 4/6 quad /Signaling cable with Heat Shrinkable straight through Jointing 74 Kit. All the material required for the work are to be arranged by contractor himself at his own cost except Thermo shrinkable Joint Kit/Rapid Joint kit. After jointing the cable through test such as insulation test, continuity cable losses etc. to be carried out jointly with Railway Engineer. If any defect or any damage is observed during jointing, the contactor has to redo the joint free of cost
Execution of Gate (slave)telephone. This Includes testing and commissioning, all installation related material to be supplied by the contractor as per site requirement
Loading and transportation of S&T cable from the stores of Consignee godown and unloading at the site of laying.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderdocLCinterclocking.pdf TENDER DOCUMENT
ATTACHMENT
TenderdocLCinterclocking.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].