Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹3.2 Cr |
Tender Value
₹3.7 Cr
EMD Value
₹7.4 L
Closing Date
5 Apr 2026, 5:00 pmClosed
Gopal Prasad Singh
EE PDA
1ST FLOOR, UDYOG BHAWAN EAST GANDHI MAIDAN PATNA 800004
Gopal Prasad Singh
EE PDA
(Re-Tender) Upgradation/Renovation work of Institute of Entrepreneurship Development (IED), Bihar, Patna
128003
NIT 08/TEN/IDA/26
Open Tender
CIVIL
Patna
• REGISTRATION
Class
• ELECTRICAL LICENCE REGISTRATION
• "LEGAL STATUS OF BIDDER
ITB clause 4.3 (a)
• PERMANENT ACCOUNT NUMBER (PAN)
• GST REGISTRATION
• "COST OF BOQ
(e payment only)"
• EARNEST MONEY DEPOSIT (BID SECURITY)
• WORK EXPERIENCE OF SIMILAR NATURE (Multistoried Building Work)
Section 1 ITB 4.5 (A) (b) of SBD
• "QUANTITY WISE EXPERIENCE
(EXECUTED QUANTITY IN ANY ONE FINANCIAL YEAR DURING LAST FIVE YEARS ITB clause 4.5 (A)( c ), 4.5 (A) (d) & 4.5(A)(e))
MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
Furniture : Rs. 22,38,814.00
Electrical Work +HVAC Work : Rs. 68,50,054.00
PHE Work : Rs 1,67,601.00
Lift Work : Rs 5,62,847.00
Structural Steel Work : 7899.96 Kg
Aluminium Work : 685.03 Kg
Wall Panelling Work : 449.845 Sqm
• "ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS
ITB clause 4.5 (A)(a)
(Balance Sheet, Profit & Loss And Audit Report duly audited by CA)"
"FY 2020-2021 Amount To be entered (Rs in Lakhs)"
"FY 2021-2022 Amount To be entered (Rs in Lakhs)"
"FY 2022-2023 Amount To be entered (Rs in Lakhs)"
"FY 2023-2024 Amount To be entered (Rs in Lakhs)"
"FY 2024-2025 Amount To be entered (Rs in Lakhs)"
• BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR
AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST)
Section 1 ITB 4.2 ( i ) of S.B.D
• BIDDING CAPACITY (BC=A*N*3-B)
Section 1 ITB 4.7 of S.B.D"
• (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS
• (B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED
• "BANKERS' CERTIFICATE FOR EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT FACILITIES
• "AFFIDAVIT
• CHARACTER CERTIFICATE
• UNDERTAKING
(i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract.
Section 1 ITB 4.2 (ii) of SBD
• (ii) Bid Validity : 120 days
Section 1 ITB 15.1 of SBD
• LITIGATION HISTORY
Section 1 ITB 4.3 ( j ) of SBD"
• "PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION
Section 1 ITB 4.3 ( l ) of S.B.D"
• TECHNICAL PERSONNEL
Section 1 ITB Clause 4.5 B (b)"
• LIST OF KEY PLANTS & EQUIPMENTS
Section 1 ITB 4.5 B (a)"
CIVIL
ITEM RATE
L1
1
24 documents required · 24 mandatory
₹11,800
Processing Fee: 5900
₹7.4 L
IDA, 1st Floor, Udyog Bhawan, East Gandhi Maidan, Patna 800004
2 Sept 2026
24 Mar 2026
6 Apr 2026
24 Mar 2026
5 Apr 2026
24 Mar 2026
25 Mar 2026
INFRASTURUCTURE DEVELOPMENT AUTHORITY First Floor, Udyog Bhawan, East of Gandhi Maidan, Patna
TECHNICAL BID SHEET
TENDER NUMBER 08/TEN/IDA/26 DATE OF ISSUE OF TENDER 16.03.2026
NAME OF WORK (Re-Tender) m|ferk fodkl laLFkku] (IED)] fcgkj] iVuk ds Upgradation/Renovation dk dk;ZA COST OF WORK AS PER BOQ Rs. 36,937,690.00
BID SECURITY (EARNEST MONEY DEPOSIT) AMOUNT Rs. 739,000.00 COMPLETION PERIOD IN MONTHS 6.0
NAME OF TENDERER ALL COLOURED CELL IS TO BE FILLED ACCORDINGLY
ADDRESS, E-MAIL & MOBILE NUMBER OF TENDERER
S.N. ITEMS REQUIREMENT REMARKS
1 REGISTRATION (Any Contractor Registered in appropriate category with Central Government / Any State Government / Any Public Sector Undertakings or an Agency of National or International repute may tender but Registration with Infrastructure Development Authority will be essential after issue of Letter Of Acceptance.) Department
Registration No.
Date of Validity
2 ELECTRICAL LICENSE REGISTRATION Attach Valid Self Electrical License Or Sub Contractor's Electrical License With Affidavit (Attach An Affidavit As Per Format Prescribed In SBD-Annexure III, On Or After Date Of Tender, Duly Attested By An Executive Magistrate). Department
Registration No.
Date of Validity
3 LEGAL STATUS OF BIDDER Section 1 ITB 4.3 (a) of S.B.D (i) Individual/Partnership/Pvt. Ltd./Public Ltd/Joint Venture
(ii) Place of Registration.
(iii) Principal Place of Business
(iv) Power of Attorney of Signatory Bid
4 JOINT VENTURE (Bids From Joint Ventures Are Acceptable Only Above Rs. 10.00 Crores Project) The tenderer have to submit the Joint Venture documents as per eligibility criteria & other instructions issued vide Road Construction Department Letter No. 8131 (S) dated: 24.07.2012.
5 PERMANENT ACCOUNT NUMBER (PAN) Attach Copy of PAN
6 GST REGISTRATION Attach Copy of GST
7 COST OF BOQ (e payment only) Rs. 11,800.00 (Attach e-payment receipt of BOQ)
8 EARNEST MONEY DEPOSIT (BID SECURITY) Earnest Money Deposit (Bid Security) will be accepted only in online mode (Internet Payment Gateway). No other forms of Earnest Money Deposit (Bid Security) will be accepted. Amount To Be Entered (Rs. In Lakhs) Attach e-payment of Earnest Money Deposit (Bid Security).
9 WORK EXPERIENCE OF SIMILAR NATURE (Interior Work) Section 1 ITB 4.5 (A) (b) of SBD Satisfactorily completed at least one similar work (Interior Work) of value not less than 50% of the estimated value of contract. The completion certificate shall be issued by employer not below the rank of Executive Engineer or Equivalent.
10 QUANTITY WISE EXPERIENCE Section 1 ITB 4.5 (A) ( c ) of SBD MINIMUM QUANTITY / AMOUNT AS PRESCRIBED IN SBD
Furniture : Rs. 22,38,814.00
Electrical Work +HVAC Work : Rs. 68,50,054.00
PHE Work : Rs 1,67,601.00
Lift Work : Rs 5,62,847.00
Structural Steel Work : 7899.96 Kg
Aluminium Work : 685.03 Kg
Wall Paneling Work : 449.845 Sqm
11 ANNUAL FINANCIAL TURN OVER OF LAST FIVE YEARS ITB Clause 4.5 (A)(a) (Balance Sheet, Profit & Loss And Audit Report Duly Audited By CA) FY 2020-2021 Amount To be entered (Rs in Lakhs)
FY 2021-2022 Amount To be entered (Rs in Lakhs)
FY 2022-2023 Amount To be entered (Rs in Lakhs)
FY 2023-2024 Amount To be entered (Rs in Lakhs)
FY 2024-2025 Amount To be entered (Rs in Lakhs)
12 BANKER'S CERTIFICATE EVIDENCE OF ACCESS TO OR AVAILABILITY OF CREDIT FACILITIES (10% OF PROJECT COST) Section 1 ITB 4.2 ( i ) of S.B.D Certificate Issued By Bank As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender
13 BIDDING CAPACITY (BC=A*N*3-B) Section 1 ITB 4.7 of S.B.D A = Maximum value of civil engineering works executed in any one year during the last five years (updated to the price level of the year indicated in Appendix) taking into account the completed as well as works in progress. N = Number of years prescribed for completion of the works for which bids are invited. B = Value (updated to the price level of the year indicated in Appendix) of existing commitments and on-going works to be completed during the next 06 Months(period of completion of the works for which bids are invited).
14 (A) AMOUNT OF EXISTING COMMITMENTS AND ONGOING WORKS Attach As Per Sec. 2- 1.4 (A) Of SBD, On Or After Date Of Tender (Bidder must decleare themselve their all exising commitment concealment of any fact shall be sufficient cause for rejection)
(B) AMOUNT OF WORK FOR WHICH BID ALREADY SUBMITTED Attach As Per Sec 2- 1.4 (B) Of SBD, On Or After Date Of Tender
15 AFFIDAVIT (I) Attach An Affidavit As Per Format Prescribed In Sec-2 Of SBD, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
(II) Attach An Affidavit As Per NIT, On Or After Date Of Tender, Duly Attested By An Executive Magistrate.
16 CHARACTER CERTIFICATE Attach a Valid Character Certificate of Tenderer Issued By Competent Authority.
17 UNDERTAKING (i) Investment of minimum cash up to 25% of the value of the work during implementation of the contract. Section 1 ITB 4.2 (ii) of SBD (I) Attach An Undertaking As Per Format Prescribed In Sec. 2 Of SBD.
(ii) Bid Validity : 120 days Section 1 ITB 15.1 of SBD (II) Attach An Undertaking As Per Format Prescribed In Sec. 8 Of SBD.
18 LITIGATION HISTORY Section 1 ITB 4.3 ( j ) of SBD As Per Format Prescribed In Sec. 2-1.11 Of SBD On Or After Date Of Tender.
19 PROPOSED METHODOLOGY AND PROGRAMME OF CONSTRUCTION Section 1 ITB 4.3 ( l ) of S.B.D Attach Descriptions,Drawings And Charts As Necessary.
20 TECHNICAL PERSONNEL Section 1 ITB Clause 4.5 B (b) Attach As Per Sec-2-1.6 Of SBD. Attach Necessary Certificate And Current Affidavit Of Both Employee And Employer On And After Date Of Tender, Duly Attested By An Executive Magistrate.
21 LIST OF KEY PLANTS & EQUIPMENTS Section 1 ITB 4.5 B (a) Attach As Per Sec 2-1.5 Of SBD (Max. Age 5 Years). Attach Owned Voucher/Cash Memo/Invoice And Affidavit In Case Of Leased/Hire On And After Date Of Tender, Duly Attested By An Executive Magistrate.
I, the undersigned, do hereby certify that all the statements made in the required attachements are true and correct.
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 08/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.)
2 Total Non-Schedule Amount (Rs.)
TOTAL AMOUNT Rs.
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
SL.NO DESCRIPTION AMOUNT
1 TOTAL SCHEDULE ITMS
2 TOTAL NON SCHEDULE ITEMS
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
BASED ON S.O.R. B.C.D.GOVT. OF BIHAR EFFECTIVE FROM 01/01/2022/MR
SL.NO DESCRIPTION UNIT Civil PHE RWH ELEC AC Furniture Reno. Work Fire Solar Power Lift Total Qty. RATE AMOUNT
1 Dismantling tile work in floors and roofs laind in cement mortar including stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm Sqm 30.7
15.2 Demolishing cement concrete including disposal of material within 50 metre lead:
15.2.2 1:4:8 or leaner mix Cum
15.7 Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead:
15.7.4 In cement mortar Sqm 823.7
15.12 Desmantiling doors windows and clerestory windows (steel or wood) shutters including chowkhats, architrage, holdfasts etc. complete and stacking within 50 metres lead:
15.12.1 Of area 3 sqm and below Each 80
15.56 Dismantling old plaster or skirting raking out jounts and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Sqm 25 21.7
15.6 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Cum 10 219.3
14.46 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. Sqm 25
SOR 2.8 Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m
SOR 2.8.1 All kind of soil Cum 59.07 360.7
SOR 2.28 Supplying and filling in plinth with sand under floors including watering,ramming consolidating and dressing complete Cum 2.02 287.3
SOR 4.1 Providing and laying in position concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level
SOR 4.1.3 1:2:4(1cement:2 corse sand:4 graded stone aggregate 20mm nominal size Cum 1.44 3998.1
4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor five level, excluding the cost of centering, shuttering and finishing:
4.2.3 1:2:4 (1 Cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) cum 5128.3
4.2.5 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) cum 4564.2
4.2.6 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) cum 4410
SOR 5.3. Reinforced cement concrete work in beams,suspended floors roofs,having slope upto 15, landing,balconies, shelves, chajjas, lintal, bends,plain window sills stair case,and spiral staircases up to floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:2:4 Cum 11.61 5335.9
5.5 Reinforced cement concrete work in arhes, archribs, domes, vaults, shells, folded plate and roofs having slope more than 150 upto floor five level excluding the cost of centring. Shuttering. Finishing and reinforement with 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) cum 5677.1
5.37 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement
content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
5.33.2 All work from plinth level upto floor V level
5.33.2.2 Concrete of M-30 grade with minimum cement content of 350 kg/cum cum 5989
5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal
5.9 Centering and shuttering including strutting, propping etc. and removal of form for:
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. Sqm 13.68 211.6
5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 12.34 437.5
5.9.4 Shelves (Cast in situ) sqm 437.5
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 404.7
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 494.4
5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. sqm 224.2
5.9.19 Weather shade, Chajjas, corbels, etc. including edges. sqm 3.3875 550.9
5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete.
5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia Kg 760 56.7 94.5
5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia Kg 500 92.6
5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia Kg 150 90.8
5.22.7D Thermo-Mechanically Treated bars TMTFe-500-16mm dia Kg 91.7
5.22.7E Thermo-Mechanically Treated bars TMT Fe-500-20mm dia Kg 91.7
5.22.7F Thermo-Mechanically Treated bars TMT Fe-500-25mm dia Kg 91.7
SOR 6.1A Brick work with F.P.S bricks of class designation 75 in foundation and plinth in:
SOR 6.1.14A Cement morter 1:6(1 cement : 6 corse sand) Cum 1.74
6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
6.1.14C Cement mortar 1:6(1 cement:6 coarse sand) cum 4923
6.3C Extra for Brick work in superstructure above plinth level upto floor V Level cum 842.2
6.1.14A +6.3A Brick work with bricks of class designation 100A in foundations and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand )
Extra for Brick work in superstructure above plinth level upto floor V cum cum 5662.1
6.18A+ 6.19A Half brick masonry with bricks of class designation 100A in foundations and plinth in :Cement mortar 1:4 (1 cement: 4 coarse send)
Extra for half Brick masonry in superstructure above pinth level upto floor V level sqm 689
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level.
6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) sqm 700.8
6.21A Extra for providing and placing in position 2 nos. 6mm dia, MS bars at every third course of half brick masonry (with F.P.S bricks) sqm 113.6
0.9 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
9.1.1 Second class teak wood cum 120526.6
9.1.2 Sal wood cum 0 95670.7
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) each 72 24
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 2845.6
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
9.21.1 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 1775.3
9.23 Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (over all area of door shutter to be measured) sqm 401.4
9.48 Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.2 Fixed to openings / wooden frames with rawl plugs screws etc. Kg 388.8 161.1
9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. each 10 979.5
9.96 Providing and fixing aluminium sliding door bolts ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with nuts and screws etc. complete:
9.97 Providing and fixing aluminium tower bolts ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
9.97.4 150x10mm Each 58
9.1 Providing and fixing aluminium handles anodised ISI Marked (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
9.101 Providing and fixing aluminium hanging floor door stopper ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper Each 14 60.8
9.103 Providing and fixing bright finished brass 100mm mortice latch and lock with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS:1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). Each 5 655.4
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 386.1
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 447.2
21.3 Providing and fixng glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With glass panes of 5.50 mm thickness(weight not less thar 13.75 kg/sqm) Sqm
21.8 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
21.8.1 Upto 5mm depth and 5 mm width Meter 85.2
9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 6690.7
9.147D.1 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.
Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
9.147D.2 Two track two panels sliding window made of (small series)frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 704.9
10.16 Steelwork inbuilt up tubular (round, squareor rectangular hollowtubes etc.)trussesetc., including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer, including welding and bolted with special shaped washers etc. complete
1O.16.1 Hot finished welded type tubes Kg 11768.98 123.9
10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 22 165.4
10.2 Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved ateef primer all complete Kg 95.4
12.5 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. sqm 625.1
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self drilling/ self tapping screws complete :
12.51.1 Ridges plain (500 - 600mm) rmt. 17.25 396.8
12.51.6 Gutter (600 mm over all girth) rmt. 25.7 898.7
10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, Kg 114.6
10.33 Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying apriming coat of approved steel primer
10.33.1 MS tube (medium) 40mm nominal bore Kg 121.9
11.38 Providing and laying Ceramic glazed floor tiles 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brow laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement: 4 Coarse sand) including pointing the joints with white cement and matching pigments etc. complete. sqm 13.740625 862.4
11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sqm 53.865 795
11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 60x60 cm sqm 1638.8
11.41.3 Size of Tile 800 x 800 mm. sqm 2116.5
11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
11.46.2 Size of Tile 600 x 600 mm. sqm 1191.8
11.46.3 Size of Tile 800 x 800 mm. sqm 1658
11.41 A Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Laying on Toilet floor / Wall
11.41A.2 Glazed vitrified floor tiles polished finish of Size of Tile 600 x 1200 mm sqm 1356
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
8.2.2 Granite of any colour and shade
8.2.2.1 Area of slab upto 0.50 sqm sqm 1.37625
8.2.2.2 Area of slab over 0.50 sqm sqm 5.865 4401.2
8.4 Extra for fixing marble/granite stone over and above coresponding basic ite, in facia and drops of width upto 150 mm with expoxy resin based (Araldite or equivalent) adhesive including cleaning etc. complete. m 10
8.5 Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/stone work including necessary holes for pillar taps etc. including rubing and polishing of cut edges etc. complete. each 6 428.2
7.38 Stone tile work for wall lining with special adhesive like araldite or equivalent over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand ) including pointing in white cement with an admixture of pigment to match the stone shade .
7.38.1 8 mm thick (mirror polished and machine cut edge )
7.38.1.1 Granite black stone sqm 1900.9
10.37 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
10.37.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. Sqm 656
11.26 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand )
11.26.1 20 to 25 mm thick sqm 1252.7
11.27 Kota stone slab 25mm thick in risers of steps skirting. Dado & pillars laid on 12mm (average thick cement mortar 1:3( 1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. sqm 1334.9
SOR' 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes royalty all complete as per specification and direction of E/I. Per M2 283.3
13.11 12mm cement plaster of mix:
13.11.4 1:6(1 cement: 6 coarse sand) sqm 141.5
13.12 15mm cement plaster on the rough side of single or half brick wall of mix:
13.12.4 1:6(1 cement: 6 course sand) sqm
13.13 20mm cement plaster of mix:
13.13.2 1:4(1 cement: 4 course sand) sqm 209.9
SOR 13.18 15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall. Sqm. 5.04 229.3
13.24 6mm cement plaster to ceiling of mix:
13.24.2 1:4( 1 cement: 4 coarse sand) sqm 9.2525 125.6
13.36 Extra for providing and mixing water proofing material in proportion recommended by the manufacturers.
13.36.6 20mm cement plaster 1:4( 1 cement: 4 sand) sqm 10.1
13.37 Extra for plastering exterior walls of height more than 10m form ground level for every add it .irate height of 3 m or part there of sqm 44.4
13.77A Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications
13.77A.1 Two or more coats on new work sqm 56.6
13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
13.92.1 Two or more coats on new work sqm 86.4
13.95 Painting with aluminum paint of approved brand and manufacture to give an even shade.
13.95.1 Two or more coats on new work Sqm
13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete sqm 105.4
13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface:
13.78.1 Cement primer sqm 38.6
13.79 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
13.79.1 New work (three or more coats) sqm 81.2
13.46A Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade.
13.46A.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm). sqm 132.5
13.81 Applying priming coat:
13.81.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) sqm
13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.93.1 Two or more coats on new work sqm 84.5
13.94 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
13.94.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. sqm 116.5
0.000 French spirit polishing:
13.101.1 Two or more coats on works including a coat of wood filler. Sqm 215.8
15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: Cum 1411.2
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutoutsmade with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.45.2 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I sqm 964.9
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions.(ii) 11 nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) Illrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) Ivth course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni). sqm 10.62 480.6
26A.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the rchitectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS74,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). kg 370.4
26.A.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture,as per the approved sealant design, within and all around the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified,as per the approved shop drawings and as directed by the Engineerin-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by BL(National Accreditation Board for Testing and Calibration boratories), Department of Science &Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
1. Performance Laboratory Test for Air Leakage Test (-50pa to –300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME-331- 09 testing method for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” Sqm 3111.4
26A.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Sqm 3377.5
26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
26.27.1 With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) Sq.M 18 1832.4
14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. sqm 178.3
12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52X.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. Sqm 1348.4
Carriage of Materials with loading & unloading:-
Bricks 100A(local lead 8KM( 1K+7P) excluding Fly Ash brick ‰ No. 0 585 26452 50584
Coarse sand lead By Rail from Koilwar Cum 5.71 20.78 1550.08
Stone chips lead By Rail form Gaya Cum 11.22 0.64 1427.28
Local Sand 3 KM( Lead local 1K+2P) Cum 0 2.29 0
Cement Local Sand 5 KM (P) mt 518.09
Steel Lead 5 KM (P) mt 518.09
Difference Cost of materials :-
Bricks 100A (excluding Fly Ash brick) ‰ No. 0 585 26452 1606.89
Cement(PSC) mt 7.43 6.14
SOR. 17.1 Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests. Each 2
SOR 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lif, 10 litre low level white vitreous china flushing cistern & C.P flush bend with fittings & C.I brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
17.3.1 W.C pan with ISI marked white solid plastic seat and lid Each 2 5504.3
SOR 17.31 Provding and fixing 600X450mm beveled edge mirror of superior glass complete with 6mm thick hard board ground fixed to wooden cieats with CP brass screws & washers complete. Each 8 1068.5
SOR 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required:
SOR 17.10.1. Kitchen sink with drain board
SOR 17.10.1.4 510x1040mm bowl depth 178mm Each 3 5231.5
SOR 17.28 Provding and fixing PVC waste pipe for sink & wash basin including PVC waste fittings complete
17.28.2 Semi rigid pipe
SOR 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
18.7.2 20 mm Nominal outer dia pipes Metre 3 233.9
18.7.3 25 mm Nominal outer dia pipes Metre 5 317.3
18.7.4 32 mm Nominal outer dia pipes Metre 3 395.2
18.7.5 40 mm Nominal outer dia pipes Metre 12 538.4
SOR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the
18.8.1 15 mm Nominal outer dia pipes Metre 6 278.2
18.8.2 20 mm Nominal outer dia pipes Metre 13 350.8
18.8.3 25 mm Nominal outer dia pipes Metre 6 463.1
SOR. 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality.
18.17.1 25 mm Nominal bore Each. 1
18.17.3 40 mm Nominal bore Each. 2 707.3
SOR 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions.
18.21.2 45 cm length
18.21.2.1 15 mm Nominal bore Each. 4 85.2
SOR 18.46 Providing and fixing G.I. union in G.I.pipe including cutting and threading the pipe and making long screws etc.
18.46.3 25 mm dia. Nominal bore Each. 1
18.46.5 40 mm dia. Nominal bore Each. 2 419.7
SOR 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
18.50.1 15 mm Nominal bore Each 3 1242.8
SOR 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia Metre 391.7
SOR 19.01 Providing, laying and jointing glazed stoneware pipes class SP-1 'A' with stiff mixture of cement mortar in the proportion of 1:1(1 cement: 1 fine sand) including testing of joints etc. complete.
19.1.2 150mm diameter Metre 2.4 464.3
SOR 19.02 Providing and laying cement concrete 1:5:10( 1 cement: 5 coarse sand:10 graded stone aggregate 40mm nominal size) all-round S.W pipes including bed concrete as per standard design.
19.2.2 150mm diameter S.W pipe Metre 2.4 494.4
SOR 19.4 Providing and fixing square mouth SW gully trap grade A complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size(inside) the wt. of cover to be not less than4.50kg. And frame to not less than 2.70 kg. as/standard design
19.4.3 180x150mmsize p type
19.4.3.1 With F.P.S. bricks designation 7.5 Each 2 1994.1
SOR 19.6 Providing and laying non -pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc.
19.6.2 150 mm dia R.C.C. pipe Metr. 410.7
SOR 19.7 Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design:
19.7.1 Inside size 90x80cm and 45cm deep including C.I cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
19.7.1.1 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 Each 1 7914.7
SOR 19.8 Extra for depth for manholes
19.8.1 Size 90x80cm
19.8.1.1 With F.P.S bricks class designation 75 Metre 0.1 5660
SOR 19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design
19.15.1 With 20x20mm square bar Each 8 290.5
SOR 19.18 Supplying and fixing C.I cover without frame for manholes:
SOR 19.18.2 500 mm diameter C.I cover (medium duty) the weiht of he cover to be not less than 58 kg. Each 2 3164.6
SOR 19.30 Constructing brick masonry chamber for underground C.I inspection chamber and bends with 75 class designation bricks in cement mortr 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
19.30.1 Inside dimensions 455x610mm and 45cm deep for single pipe line:
19.30.1.1 With F.P.S bricks Each 4266.8
SOR 19.31 Extra for depth beyond 45cm of brick masonry chamber:
19.31.1 For 455x610mm size
19.31.1.1 With F.P.S bricks Metre 3946.2
D RAIN WATER PIPE
SOR 12.78 Providing and fixing on wall face PVC (working pressure 4kgf per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.78.2 110 mm diameter Metre 24 257.5
SOR 12.79 Providing and fixing on wall face PVC moulded fitting / accessories for rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.79.1 Coupler
12.79.2 Single pushfit Coupler:
12.79.3 Single tee with door
12.79.5.2 110 mm bend Each 6 132
SOR 12.80 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S screws of required length, including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
SOR 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 6 47.9
SOR 24.1 Boring/drilling borewell of required dia for casing/strainer pipe by suitable method prescribed in IS:2800(part-I),including collecting sample from different strata,preparing and submitting strata chart/bore log,including hire & running charges of all equipments,tools,plants and machineries required for the job ,all complete as per direction of engineer in charge,upto 90 metre depth below the ground level
SOR 24.1.1 All type of soil
SOR 24.1.1.1 300 mm dia metre 40 486.8
SOR 24.3 Supplying,assembling,lowering and fixing in virtical position in borewell ,unplasticized PVC mediumnwell casing (CM) pipe of required dia, confirming to IS:12818,including required hire and labour charges,fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
SOR 24.3.2 150 mm nominal dia metre 37 660.1
SOR 24.4 Supplying,assembling,lowering and fixing in virtical position in borewell ,unplasticized PVC medium well screen (RMS) pipes with ribs , confirming to IS:12818,including required hire and labour charges,fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
SOR 24.4.2 150 mm nominal dia metre 6 673.5
SOR 24.5 Supplying , filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in Recharge Pit,in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3.18
SOR 24.6 Supplying , filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the Recharge Pit,over the existing layer boulders in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3
SOR 24.7 Supplying , filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm, in the Recharge Pit, in the required thickness over gravel layer ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3
SOR 24.13 Providing & fixing suitable size thre platebto top of borewell housing/casing pipe,removable as per requirement all complete for borewell of
SOR 24.13.2 150 mm dia each 1 210.7
SOR 24.14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete
SOR 24.14.2 150 mm clamp each 1 1531.4
SOR 24.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
9.2 Single headed Stainless steel Each 1 5722
17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
16.2 Stainless steel (Grade 304) Each 2 4445
18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
18.2 Stainless steel (Grade 304) Each 1 1631
13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Each 1 1236
Civil 18.59 Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately)
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
14.7 150 mm dia Each 1 15398
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
11.6 150 mm dia Each 1 8241
SUBHEAD-II (B):PIPING FOR FIRE FIGHTING SYSTEM
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground)
Threaded joint upto 50mm diameter pipe.
Welded joint above 50mm diameter pipe.
7.8 150 mm nominal bore (class C) Rm 3 1856
7.7 100 mm nominal bore (class C) Rm 3 1316
7.6 80 mm nominal bore (class C) Rm 5 951
7.5 65 mm nominal bore (class C) Rm 5 832
7.4 50 mm nominal bore (class C) Rm 6 646
7.3 40 mm nominal bore (class C) Rm 3 509
7.2 32 mm nominal bore (class C) Rm 6 417
7.1 25 mm nominal bore (class C) Rm 60 359
21 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
21.3 Horizontal side wall sprinkler Each 0 0
21.1 Pendent type Sprinkler Each 25 408
21.2 Upright type sprinkler Each 0 408
22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each 1 1442
25 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
29 Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. Each 1 167
Add 5.357 % GST on SOR Item as per BCD
DSR 25 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in
meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. (Inclusive of all compents i.e solar plate, frame, inverter, earthing, wiring, bidirectional meter, apply and obtaining NOC from electrical inspector,all necessary item and liasioning with SBPSCL for commissioning and intergrating the system with grid system) (Make- Vikram, Adani, Novasys , Luminous or approved equivalent as per approval of EIC) KWp 25 54280
Electrical work Make As per BSR Approved Make list as approved by Engineer in Charge
8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 8 2482
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required Each 8 358
8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.17.1 300 mm sweep Each 3 2572
8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required. Each 8 3670
5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. Each 21 2663
5.3 Supplying and fixing 4'x20 watt LED batten with minimum efficacy 100lm/w in aluminoum housing and complete with integrated electronic driver etc. directly on ceiling / wall including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable etc. as required. Each 6 762
5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
5.7.3 12 watt Each 48 1224
1.34 Supplying and fixing batten / angle holder including connections etc. as required. Each 8 80
6.1 Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required.
6.1.6 15 watt LED lamp Each 8 250
1.33 Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Each 9 64
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps moduler socket outlet & 6A modular type switch connection etc. as required. Point 17 414
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/ 16 amps moduler socket outlet & 15/16A modular type switch connection etc. as required. Point 11 531
1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. Each 6 683
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.1 5/6 amps switch Each 28 20
1.24.4 3 pin , 5/6 amps socket outlet(For wall fan only) Each 8 28
1.24.6 Telephone socket outlet Each 8 131
1.24.7 TV antenna socket outlet Each 1 131
1.27 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches/ socket/TV / Telephone outlet in surface/ recess etc. as required.
1.27.1 75mmX75mmX50mm Each 234
MP PWD 38.4 Supply, installation testing and commissioning of telephone tag block krone connector with enclosure complete as mentioned below
MP PWD 38.4.1 10 Pair Each 1
1.26 Supplying and fixing modular blanking plate on the existing modular plate & metal box excluding modular plate, etc. as required. Each 10 34
Supplying and fixing metal/ PVC box of following sizes ( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
1.22.1 75mmX75mmX60mm deep Each 4 139
1.22.6 200mmX150mmX60mm deep Each 2 276
1.3 Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch , modular plate suitable size G.I. box etc as required.
1.3.3 Group C Point 90 1146
Wiring for group controlled (looped) light point/ fan point/ exhaust fan point / call bell point (without independent Switch etc.) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit etc as required.
1.59.3 Group C Point 12 609
1.5 Wiring for power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required Meter 340 309
1.7 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Meter 246
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 70 150
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire Meter 150
Supplying & fixing of following size medium class PVC conduit along with accessories in surface/ recess including cutting of wall and making good the same in case of recessed conduit as required.
1.21.1 20 mm dia Meter 102
1.21.2 25 mm dia Meter 20 120
1.17 Supplying and drawing co-axial W cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed PVC conduit as required. Meter 20 42
1.16 Supplying and drawing following pair 0.5 sq. mm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed PVC conduit as required.
1.16.2 2 Pair Meter 160 31
MP PWD 38.3 Supply installation, testingand commissioningof 0.5mm size solid annealed copper, jelly filled telephone cables, polythene insulated, petroleum jelly filledwithpoly-al laminatemoisturebarrier, polythene sheathed, armoured polythene jacketed telephone cables as per DOT specifications of following sizes
MP PWD 38.3.1 10 Pair Meter 30
MAIN PANEL & D.B.s
2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus -bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), Double door, horizontal type Each 2 4148
2.9.2 6 way ( 4 + 18 ), Double door, horizontal type Each 1 5132
2.32 Supplying and fixing cable end box ( Loose wire box , IP 43) suitable for following sheet steel M.C.B. Distribution board, on surface/ recess, complete with testing commissioning etc. as required
2.32.4 For 4 way Double door MCB TPN DB Each 1 1064
2.32.5 For 6 way Double door MCB TPN DB Each 1 1111
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
2.12.1 6 Amp. To 32 Amp. SP MCB 240 Volt Each 72 237
2.12.4 32 Amp TPN MCB 415 Volt Each 1282
2.12.8 40/63 Amp TPN MCB 415 Volt Each 2329
2.14 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Each 5 13
Providing and fixing of following rating electrical items in existing cubical panel including drilling holes in if required, making connections etc. as required .
2.7.7 250 A four pole ON-load panel mounted changeover switch Each 1 21415
COMPUTER NETWORK
1.58.1 Supplying and drawing of UTP 4 Pair CAT-6 LAN cable in the existing surface / recessed PVC concuit etc. as required. Meter 52
1.56 Supplying and fixing suitable size GI box with moduler base & cover plate in front on surface or in recess including providing and fixing of 3nos 5 pin 5/6 amps socket outlet and 2 nos 5/6A moduler switch connection etc. as required. Set 40 778
DSR 2025 39.14 Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. Each 80 212
DSR 2025 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Each 2 5278
DSR 2025 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.12.1 Copper Patch Cords of length 1m (3ft) Each 40 151
39.12.2 Copper Patch Cords of length 3m (10ft) Each 80 227
DSR 2025 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
39.23.1 6U Rack Each 6939
39.23.2 9U Rack Each 2 8960
DSR 2025 39.3 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
39.3.2 24 port Layer 2 Non-PoE Network Switch Each 2 86163
DSR EnM 2025 39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
i 39.1.2 8 port Layer 2 Non-PoE Network Switch Each 6 28073
DSR 2025 39.7 Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. Each 6 22739
DSR 2025 39.16 Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required Each 80 9
DSR 2025 39.19 Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required.
i 39.19.1 Single Mode 6 Core Optical fiber cable Meter 100 64
DSR EnM 2025 40.3 Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
DSR EnM 2025 40.3 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
DSR EnM 2025 40.3 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
i 40.3.1 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement). Each 30 10365
DSR EnM 2025 40.4 Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
DSR EnM 2025 40.4 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
DSR EnM 2025 40.4 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
40.4.1 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Each 10 10063
DSR EnM 2025 40.11 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
DSR EnM 2025 40.11 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
DSR EnM 2025 40.11 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF
DSR EnM 2025 40.11 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection
DSR EnM 2025 40.11 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception
DSR EnM 2025 40.11 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation
i 40.11.2 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 Each 1 82600
DSR EnM 2025 40.12 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
40.12.1 4TB (Terabytes) Each 8 13943
MP PWD 54.27.1 + GST 8 port PoE switch with 2 SFP ports Supply, installation testing and commissioning of 8 port PoE switch with 2 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP cat. 5, cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 40 GBPS, maximum 64 bytes packet forwarding rate, 14.88 MBPS, ports 1 to 8 compliant with 802.3at Each 8 27168.32
MP PWD 54.28.1 + GST 24 port PoE switch with 4 SFP ports Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP Cat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at Each 1
DSR EnM 2025 39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
39.1.1 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. Each 35091
DSR EnM 2025 39.3 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
i 39.3.1 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. Each 125393
42.4 Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.(Make-Samsung/LG/Dell/HP or Approved Equivalent)
42.4.3 55 inch or larger Each 1 82057
Make-Mahindra /Kirloskar/Cummins or Approved Equivalent
DSR EnM 2025 29.1 Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
DSR EnM 2025 29.1 (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
DSR EnM 2025 29.1 (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
DSR EnM 2025 29.1 (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
DSR EnM 2025 29.1 (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
DSR EnM 2025 29.1 F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
DSR EnM 2025 29.1 (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
DSR EnM 2025 29.1 (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
DSR EnM 2025 29.1 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
DSR EnM 2025 29.1 9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning
DSR EnM 2025 29.1 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.15 240 sq. mm, 3.5 core Meter 50 2228
7.1 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
7.1.4 Above 185 sq. mm and upto 400 sq. mm Meter 60 368
7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.4 Above 185 sq. mm and upto 400 sq. mm (Clamped with 40 x 3 mm MS flat clamp) Meter 10 171
0.9 Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. Cum 5 242
0.0 Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 metres. Cum 3 155
9.14 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. In the existing trench, complete as required.
9.14.5 200 mm dia (OD-200 mm & ID-175 mm nominal) Meter 10 572
DSR EnM 2025 10.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
10.5.4 Above 185 sq. mm. and upto 400 sq.mm M 10 170
DSR EnM 2025 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as reguired.
3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. Set 2 13721
3.10 Supplying and laying 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode, including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. Meter 60 1628
3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. Meter 60 144
3.2 Earthling with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. Set 2 6323
3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. Set 2 6884
3.11 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. Meter 30 721
3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. Meter 100 37
3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. Meter 30 53
4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l' base plate including holes etc. complete as required. Each 8 416
4.3 Fixing of lightning conductor finial (single prong) with base plate including holes etc. as required Each 8 224
4.4 Jointing copper/ G.l. tape (with another copper/ G ltape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. Each 8 81
4.7 Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) Metre 50 102
4.8 Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) Metre 240 145
4.4 Riverting and sweating and soldering of copper /G.I. tape (with another copper /G. I. tape, base of the finial or any other metallic object ) as required. Each 8 81
4.12 Providing and fixing testing joint made of 20x3mm thick GI 125 mm long with 4 nos of bolts nut and spring washer etc complete as required . Each 8 102
1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.1 5/6 amps switch Each 28 82
8.14 Supply and fixing extra down rod for ceiling fan of 1 metre length G.l. pipe, 15 mm dia, heavy guage including painting etc. as required. Each 8 409
2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts,on surfac / recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator)
2.8.7 12 way, Double door Each 1 2314
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required'
2.12.2 6A to 32 A, SP&N Each 1 606
2.25 Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 20 amps "C" curve,TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 2 3008
8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) SQFT 36 1809
8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. Each 2 6536
2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' (Make- LK, Legrand, ABB, Schneider or approved equivalent as per approval of EIC)
2.4.5 250 A,36 KA, FPMCCB Each 2 18646
2.4.1 l00 A, 30 KA, FPMCCB Each 8172
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2.12.8 40 A to 63 A, TP&N Each 2329
2.12.1 6 A to 32 A, Single pole Each 4 237
1826 (A.R) 32 mm X 6 mm copper tape ( 1.705 kg/mtr) kg 10 820
1101 (A.R) 1.5 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 25 24
1103 (A.R) 4.0 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 140 56
1107 (A.R) 25 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 40 411
2.33 Supplying and fixing , following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as lncomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBS)
2.33.2 6 way, Double door, l/C 160A , MCCB Each 1 13710
DSR 25 4.1 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness Metre 40 686
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Metre 40 866
3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. Set 4 16675
3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. Metre 20 1180
3.15 Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. Metre 20 195
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. Each 8 1275
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.9 50 sq. mm, 3.5 core Metre 50 561
7.7.12 120 sq. mm, 3.5 core Metre 20 1186
2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
DSR 25 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
DSR 25 26.1 Online UPS - Input supply: Single Phase, Output Supply: Single Phase. (Make- Vertiv, APC, Numeric or approved equivalent as per approval of EIC)
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.
The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) .
The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
MP PWD 42.84 + GST Supply and fixing transformer breather with silica gel suitable for 100 -500 KVA as reqd . Each 1
MP PWD 42.85 + GST Supply and filling of new transformer oil of desired break down value for topping as reqd. Ltr 100
MP PWD 42.86 + GST Filtration of transformer oil for 33/0.4 KV, 11/0.4 KV 3 phase 50 cycle oil immersed, naturally cooled, distribution transformer upto desired break down value. Ltr 150
DSR 25 2623 Eye Hook Each 8 32
DSR 25 28.1.4 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. Each 6 444
DSR 25 28.1.7 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. Each 6 530
DSR 25 28.1.9 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
DSR 25 28.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. MTR 105 192
Analysis Rate Cutting making conceling and finishing the pre existing wiring of each floor job 4 7786
Make-Carrier/Toshiba /O-General/Mistubishi or Approved Equivalent
1 SPLIT AC (inverter model, Cooling only) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to SO deg. C & heating within 'b deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/ indoor units should be of same make (brand). The cost includes contractor profit, labour cess, supply, transportation cost, installation, testing and commisioning cost.
1.1 1.5 TR, 5 star Each 1 58500
3 Supply installation testing and commissioning of Atomatic Voltage Stabilizer of Capacity 4 KVA, input voltage -130V± 10% and output-220 V ± 10% of Capacity & input Range 130V to 280V Model (For 1.5 Ton AC) Each 1 4800
6 Refrigerant:- Supply and additional refrigerant charge of refrigerant R410/410A & equivalent Eco friendly green gas to compensate the additional piping done at site for all systems including testing commissioning as required, kg 25 1695
7 Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.
7.2 25 mm dia ID Meter 30 238
7.3 32 mm dia ID Meter 30 350
9 Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm/13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification.
9.4 34.9 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Meter 20 50
9.5 31.8 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Meter 50 36
9.6 28.6 mm O.D. wall thickness ≥ 1.2mm (insulation – 19 mm thick) Meter 30 1640
9.8 22.2 mm O.D. wall thickness ≥ 1.0mm (insulation – 19 mm thick) Meter 50 31
9.9 19.1 mm O.D. wall thickness ≥ 1.0mm (insulation – 13 mm thick) Meter 10 20
9.1 15.9 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 10 1031
9.11 12.7 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 10 813
9.12 9.5 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 80 693
9.13 6.4 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 80 560
10 VRV/VRF outdoor AC unit:- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based scroll type compressors, electronic expansion valve, R 410A/ecofriendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg. C & heating within 0 deg. C to 15 deg. C, COP not less than 3.3. Each system should have the provision to combine maximum 3 nos compressor in each outdoor unit, every single outdoor unit should not have more than maximum Capacity 20 HP (3 phase) each compressor complete as per specification. Outdoor/indoor units should be of same make (brand). (Single phase/three phase)
12 VRF/VRV indoor AC unit (ceiling mounted 4 way):- Supply installation testing and commissioning of 4 way round flow ceiling suspended/mounted cassette type unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, auto air swing louvers, temperature &on/off display with inbuilt drain pump & decorative panels including internal wiring, controls. Dimension in terms of length & width should not be more than 950mmX 950mm with wireless remote controller. (Single phase/three phase)
16 Y joints:- Supply, installation, testing & commissioning of ref nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement, Each 5 6490
27 Controlcable: - Supply and laying, testing & commissioning of following sizes of shielded copper conductor Communication cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required.
2Cx1.5 sq.mm Meter 58 300
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
Infrastructure Development Authority, Govt. of Bihar
NON SCHEDULE ITEMS
SL.NO DESCRIPTION UNIT Civil PHE RWH ELEC AC Furniture Reno. Work Fire Solar Power Lift Total Qty. Quoted Rate In Figure (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
1 MR WALL PANELLING TYPE-1 (120mm BWP Board+ Veneer Application)
P/F Wall panelling with 12 mm thick BWP Board firmly fixed to the wall, and covered with3mm thick veneer of the given shade / colour / texture / approved equivalent, in approved pattern. The laminate may have a number of horizontal and vertical grooves / patterns / beadings as per designs and drawings. Integrating electrical points as per Electrical Drawings and design in existing wall panelling, and cuting and making good any damages is included in the scope of this item, as per instructions of the Project Engineer.
All items necessary for completing the above mentioned work are deemed to be included in the scope of work, whether or not they are specifically mentioned in the B.O.Q / tender documents / drawings.
All complete as per drawings, designs, specifications and directions of Engineer-in-Charge. (Make-Century / Green/ Merino ) sqm
MR Providing and Fixing horizontal level suspended metal ceilings comprising of Metalworks V-P 500 Hook-on baffle system manufactured by Knauf Ceiling Solutions with Rectangular vertical baffle blades made of Aluminium (Grade AA 3xxx, H14 temper) in coated thickness of 0.7mm ± 0.08mm as per IS:2676 (1981), post coated to Global White colour, suitable for architectural finishes and Interior applications, with single grid system and suitable spacing between baffles. The baffle width shall be 50mm, height shall be 100mm, length shall be 3000mm. The on-center spacing of baffles shall be 150mm (clear space between baffles 100mm). The baffles shall have plain unperforated finish with square edge, hook-on edges with suitable upturns. The baffles shall be electrostatically powder coated using RoHS compliant pure polyester powder to achieve coating thickness ranging from 60-80 microns.
The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The grids shall comprise primary U-shaped slotted carrier bars of 120gsm galvanised steel (GI) of 3000mm L x 43mm H x 30mm W x 1.5mm T. Accessories shall include baffle connector (GI), baffle face cover (GI) – RAL shade, carrier bar splice (GI), carrier spring (SS), wall anchor (GI). sqm 10
NS-2 Supplying fitting and fixing of Marvel /Hunter Douglas/D'decor Make Roller Blinds as per company specification and as per approved colour and sample inclusive of all taxes and royalty all complete as per specifications / approval and direction of Engineer-in-Charge. Sqm
MR Provding and fixing white vitreous urinal (Jaquar URS-WHT-132530) or equivalent with Aquisense Sensor concealed type flushing valve for Urinal complete set with installation box with control cock ,(jaquar CAT NO- SNR-STL-51087) etc. all complete. Each 6
MR Providing and fixing Curved shaped urinal partition with frosted glass finish: Chrome, size-900 H X 450 W (jaguar-JSE-CHR-110UC450X) or equivalent Glass: 10mm as per direction of Engineer-in-charge and finished smooth. Each 6
MR Providing and fixing counter basin size- (mm) 190x550x430 (Jaquar,CAT NO- FLS-wht-5701) including fixing and all accessories as per manufacturers specification and direction of Engineer-in-charge. Each 8
MR Provding and fixing PVC Soil ,Waste & vent pipes all complete
110 mm dia metre 42
40 mm dia metre 28
MR Provding and fixing PVC fittings all complete as/specification & directionof E/I
110 mm vent cowel Each 4
110 mm plain bend Each 1
110 mm door bend Each 1
110 mm dia X 45 Bend Each 5
110 X 110 mm dia plain - y Each 8
110 X 110 mm dia door tee Each 4
110 X 110 mm dia plain tee Each 1
110 mm pipe clip Each 13
110 X110 mm dia p-trap Each 10
40 mm elbow Each 28
40 mm plain tee Each 14
MR Providing Paper holder (jaguar AKP-35753PS) or Equivalent Each 2
MR Providing Towel Ring (Jaquar product No. AKP-35751P ) or equivalent Each 5
MR Soap dispenser (jaguar AKP-35735P) or equivalent Each 8
MR CP brass 2-way bib cock with wall flange(Kubix-F) 15mm(jaguar -KUP-35041PM) or equivalent Each 4
MR 110 mm dia cp jali Each 10
MR Providing & Fixing angle stop cock ,15 mm dia nominal bore (Jaquar -KUP-35053PM) or equivalent Each 4
MP SOR 2024 57.3 Supply, installation, testing & commissioning of water cooler with eco friendly refrigerant IN-SITUPUF Instalation Anti-corrosive body with storage of required capacity (Make-Voltas/Bluestar/Ion Exchange or Approved Equivalent)
57.3.2 Water cooler 40 liter Each 2
MP SOR 2024 57.4 Supply, installation, testing & commissioning of domestic water purifire having RO+UV+MTDS with one number prefilter having minimumwater purifying capacity of 16 liters per hour storage.installation type wall mountined/table top- stable for hardenss upto 2000mg/l operatig input voltage 150-250V AC/50 HZ (Make-Voltas/Bluestar/Ion Exchange/Aquaguard/Kent or Approved Equivalent) Each 2
MR PeopleLink or Approved Equivalent Signage Podium - Ultra
Supply Installation testing and commissioning of following ● Metallic Body with Top Sliding Mechanism ● Visualiser Tray ● Rack for Equipments ● 21.5 inches Touch Screen Monitor ● Laptop Interface with inbuilt switcher ● Gooseneck Mic(2), Wireless lapel Mic and handheld mic, ● 200 Watts DSP, ● Speaker Pair ● Central Control System with Button Pad Projector, Screen, Audio and Video Control ● 32" Signage4-microphone array 4-meter radius pickup, 85dB speaker volume,Noise reduction, echo cancellation, multi connectivity (USB, Bluetooth, 2.4G), LINE IN/OUT, extension unit support, three-party call, built-in rechargeable battery. Each 6
MR Supply Installation testing and commissioning of 75 " Interactive Display Board with Infrared Touch (40 touch Point) Input HDMI X 3 , USB-2.0 X 1 , USB 3.0-X1 Touch x 2 , USB C Type x2 (65 W) OUTPUT- HDMI OUT X 1 ,AUDIO OUT X 1, SPDIF X 1, RJ45 OUT X 1 OS Android 13/14 , RAM- 8 GB ROM 128 GB Make - MAXHUB or Approved Equivalent Each 3
MR Supply Installation testing and commissioning of 98 " Interactive Whiteboard with Interactive kit and cable like USB, Power Cable etc Make Benq / Edutek or Approved Equivalent Each 4
SHIFTING OF VRF OUTDOOR UNIT OF FIRST FLOOR TO FOURTH FLOOR
Dismantaling of 32 HP VRF outdoor Unit after necessary doing the Refrigerant back up and other work. Nos. 2
Lifting & shifting of 32 HP outdoor Unit to the Mummty of Lift & staircase including all required labour & machnary. Nos. 2
Installtion charge of 32 HP VRF Outdoor Unit with all required labour & fixing materials with anti vibration pad. Nos. 2
PCC Foundation work for the fixing of 32 HP VRF Outdoor Unit to sufficient the load carrying and proper size. Nos. 2
Copper piping of required size with tubular Insulation & with Communication cabling work with all required materials & labour. Job 2
Flushing & Leak testing with dry nitrogen of the refrigerant system with all required material & labour. Job 2
Commissioning of the system & Refrigerant charging as required. Job 2
Durian Study Table or approved equivalent in Steelcase / Usha Lexus / Wipro Study Table - TABLE TOP IN 18MM THICK PRELAMINATED BOARD WITH UNDERSTRACTURE MADE OF POWDER COATED SINGLE UNIT WITH METAL MESH SHELF FOR BOOKS TABLE SIZE: 700MML X 450MMD X 740MMH. * SCRATCHPROOF EASY WIPE TOP * METAL SHELF & WIRE SHELF WITH BAG HOOK * DURABLE ,STRONG & SAFE. Each 21
Durian Study Chair or approved equivalent in Steelcase / Usha Lexus / Wipro Durian Study Chair - CHAIR SIZE: 355MML X 381MMD X 780MMH. FIBER SEAT* SCRATCHPROOF EASY WIPE TOP SUPPORTED WITH UNDERSTRACTURE MADE OF POWDER COATED. Each 42
Durian DWS/MESS/TB or approved equivalent in Steelcase / Usha Lexus / Wipro Canteen Table - Canteen Table Size-(1200x800x750)mm table with ISO Top/Corian table supported with MS squire pipe legs the MS legs will be duly poweder coated . Each 4
Durian PJ013259 or approved equivalent in Steelcase / Usha Lexus / Wipro Dining Chair - Chair Size 525mm x 845mm x 558mm. Seat Height 450mm. Injection moulded plastic for seat and back increases rigidity and flexibility for the user Understructure has options of both MS and SS 202 grade tube Optimal Scale of the product increases comfort for all user types Absence of narrow grooves and ribs makes the maintenance of product easy Stackable design (4 chairs a stack) and ability of inverse placement on table comes in handy during maintenance of the room Retro-fit cushioned upholstery cover provided as an option makes sitting for longer durations easy Chair parts are UV stabilized as required for indoor applications to reduce colour fading effect. Each 16
Durian DWS/4800 or approved equivalent in Steelcase / Usha Lexus / Wipro Meeting Table (4800X900X750)mm- Meeting Table - Meeting Table Size L-7600 X 1500 X750MM. An all wood Durian conference table with minimalist look and basic functionality, ideal for meeting room & top comes with 40mm thik pre lam particle board & side panel 25mm thick prelam particle board & 2mm pvc edge banding with modesty given much needed ptimary and close interaction. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Black Oak. Each 1
Durian PJ0015/HB or approved equivalent in Steelcase / Usha Lexus / Wipro High Back Chair with revolving Size(W)590mm X (D)505mm X (H)1280mm. Chrome plated base with gas height adjustment and central tilting with single locking machenaism. Armrest with padding. Durian Leatherette uphlostery has the look and feel of top grain leather. Cushion wtih lumber support for all day comfort. Chrome plated loop armrest with padded upholstery for extra comfort. chair rotates a full 360 degree in either direction for ease of motion. Standard on every executive & controls rate and ease with which chair reclines to different weight and strengths of users. Quick and easy adjustment regulated height of chair relative to floor. Look out tilt function when chair is in upright position. 5% post consumed recycled content & 30% total recycled content. Color-Black. Each
Durian PJ0015/MB or approved equivalent in Steelcase / Usha Lexus / Wipro Medium Back Chair - Durian Chair Size Medium back leatherette chair in black colour with matte finish specification : durian- office seating- craze chair , type : * low back 360ø degree revolving chair, * all over size is : 660mm Lx 505mm Dx 1105mm H , *the chair made of full leatherette in black colour . it will comes in matte black finish finsih in contemporary style . details : * arms : chrome finish arms with pu padding . * use of ply: 12 mm thick hot pressed bwr plywood is grade - 303 for seat and back . * seat: 40 ñ 2 mm thick polyurethane foam with density 32 ñ3 kg per cu meter for best quality cushioning in seat , * back : 40 ñ 2 mm thick polyurethane foam with density 32 ñ3 kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support * mechanism : knee tilt mechanism . * only seat size is 525mm Lx 525mm Dx 610mm H & the back size is 660mm Lx 570mm H seat maximum height is 610mm & minimum height is 510mm & back height from floor maximum height is 1105mm & minimum height is 1005mm * gas lift 100 mm telescopic haudraulic * base : 650 mm chrome base with smooth castors. Each 16
Durian DWS/WS/1200 or approved equivalent in Steelcase / Usha Lexus / Wipro Workstation- Size (1200x600x1200)mm. ·67mm thk Sliding Tile Based Partition. Single Metal raceway cover at skirting level in Partition. Pin up & white board in partition above the tabletop. Table top made of 25mm thk Prelamin particle board with pvc edges. Pedestal of 350Lx 450Dx725 HT (2 drawer + 1filling). PVC Keyboard Tray . Metal CPU Trolley. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Each 24
Durian DWS/900/STORAGE or approved equivalent in Steelcase / Usha Lexus / Wipro Storage Cabinet- 2 Door Back Storage- Size (900x400x1050)mm. Storage top made of 25mm thk and side of 15mm thk Prelamin particle board. Storage with openable shutter with 2 shelves and lock. Storge top & shutter color will be maple and storage side & skirting color will be Dark gray. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Maple & Dark Gray. Each 30
PJ008/MB/STD or approved equivalent in Steelcase / Usha Lexus / Wipro Medium Back Chair - Chair Size (W)580mm X (D)670mm X (H)1110mm. Its Classic All-Black Look With Soft Black Fabric Upholstery Makes It An Irresistible Chair. The Deep-Cushioned Back And Seat Conform To The Natural Curvature Of The Spine For Optimum Ergonomics And Lumbar Support. The Synchro-Single Locking Mechanism Along With The Tilt Tension Control, Lets You Find Your Ergonomic Position With Ease. The Pneumatic Height Adjustment Along With The Sturdy Armrest Provide Further Comfort. A Strong Nylon Base Supports The Structure, While The 55Mm Castor Wheels And A 360-Degree Swivel Provide Swift Yet Stable Movement. Each 24
Durian DWS/1500/SU or approved equivalent in Steelcase / Usha Lexus / Wipro Table with side unit return- Table Size(1500x750x750)mm & Side runner Size(750x400x750)mm. Table made of 25mm thk pre lam particle board with edge banding. Table top supported with side panel & fron panel. Kyeboard tray & cpu trolly. Table top with wire manager & interchangable side runner with fixed pedestal of 3 drawers. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Each 2
Durian MMPL/011/VC or approved equivalent in Steelcase / Usha Lexus / Wipro Visitor Chair - Chair Size (W)590mm X (D)490mm X (H)980mm. Its moulded seat and indented back provide exceptional all-day support. Premium virgin foam sits atop a 14mm thick boiling waterproof plywood forming the moulded seat. This is then encased in deep black fabric upholstery with defined line seams that provide comfortable seating while adding depth to the high backrest. The powder-coated metal cantilever base provides extraordinary support for easy seating. Each 4
Durian DWS/1200/STORAGE or approved equivalent in Steelcase / Usha Lexus / Wipro Storage Cabinet- 2 Door Back Storage- Size (1200x400x750)mm. Storage top made of 25mm thk and side of 15mm thk Prelamin particle board. Storage with openable shutter with 2 shelves and lock. Storge top & shutter color will be maple and storage side & skirting color will be Dark gray. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Maple & Dark Gray. Each 2
M.R. Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.
Capacity 4.5 kg Nos. 3
M.R. Providing & Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) Magnetic Pressure Gauge having the facility to check at site, Discharge Time less than 9 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 21A, B Rating 55B as per BS EN-3 BIS 15683 marked, Can Construction : Deep drawn & CO2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating ofCan : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, Helium LeakDetection Tested, Warranty.
Capacity 6 Kg. Nos. 3
M.R. Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). Each 1
M.R. Providing and fixing of Fire Axe. Though the axes are to be tested to 20 000 volts their use should be limited to 1000 to 2 000 volts with precautions.. Each 1
M.R. Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete as per direction of Engineer incharge.
25 mm NB Each 1
M.R. Shifting of Fire-Fighting Pipes & Pumps Service
Providing all labour, materials, tools, and equipment for shifting the existing fire-fighting pipes from their present location on the terrace to any location as directed by the Engineer-in-Charge (E/I), complete in all respects.
The work shall include:
Making all necessary openings, cutting, extensions, or laying of new pipes, as required. Providing and fixing all accessories, specials, supports, and fittings. Executing all associated civil works and making good the disturbed surfaces to their original condition. Shutting down and restoring the water supply system as required to complete the work including repairing and serivicing pre existing pump and pipeline if required. The work shall be executed as per the directions of the E/I and shall ensure the fully functional relocation of the system complete, and shall ensure that the Fire Fighting System is fully functional and operational. Job 1
Extension of preexisting lift for 1 floor including commissiong and making lift in working condition Lift extension will be done by OEM of Pre Installed Lift only
5 L-A1, PWI13/16-19 5stops at present (Extension of 01 Floor)
Elevator Type Passenger elevator PWI13/16-19 Product IMonospace Technical Platform I MonoSpace No of Units 1 Load & Capacity 884 kg or 13 persons Speed 1.6 m/s Stops & Openings 5 stops & 5 openings, Single entrance car (at present) 01 Stops EXTENSTION (Expected 06 Openings) Total no of opening 1 entrances Travel height 14.8 m Elevator Grouping Simplex Full Collective Control Elevator main safety standard EN81-1 Well Dimension 2200 mm width and 2180 mm depth (required) Head Room height 4200 mm (required) Pit Height 1525 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1600 mm wide x 1350 mm deep x 2200 mm high Door dimensions 900 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Each 1
Dismantling of Lift Job 1
Comprehensive AMC for 3 years from OEM
INFRASTRUCTURE DEVELOPMENT AUTHORITY
(A GOVERNMENT OF BIHAR UNDERTAKING)
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
QUOTING SHEET FOR BIDDERS
Name of Contractor
Address of Contractor
E-mail ID of Contractor Whatsapp Enabled Mobile Number
NIT - 08/TEN/IDA/26
Sl no. Description Estimated Amount Rate Quoted by Contractor
% Above/Below TOTAL QUOTED AMOUNT Rs.(In Figure) TOTAL QUOTED AMOUNT Rs.(In Words)
1 Total Schedule Amount (Rs.)
2 Total Non-Schedule Amount (Rs.)
TOTAL AMOUNT Rs.
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
SL.NO DESCRIPTION AMOUNT
1 TOTAL SCHEDULE ITMS
2 TOTAL NON SCHEDULE ITEMS
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
BASED ON S.O.R. B.C.D.GOVT. OF BIHAR EFFECTIVE FROM 01/01/2022/MR
SL.NO DESCRIPTION UNIT Civil PHE RWH ELEC AC Furniture Reno. Work Fire Solar Power Lift Total Qty. RATE AMOUNT
1 Dismantling tile work in floors and roofs laind in cement mortar including stacking material within 50 metres lead.
15.23.1 For thickness of tiles 10 mm to 25 mm Sqm 30.7
15.2 Demolishing cement concrete including disposal of material within 50 metre lead:
15.2.2 1:4:8 or leaner mix Cum
15.7 Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead:
15.7.4 In cement mortar Sqm 823.7
15.12 Desmantiling doors windows and clerestory windows (steel or wood) shutters including chowkhats, architrage, holdfasts etc. complete and stacking within 50 metres lead:
15.12.1 Of area 3 sqm and below Each 80
15.56 Dismantling old plaster or skirting raking out jounts and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. Sqm 25 21.7
15.6 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. Cum 10 219.3
14.46 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. Sqm 25
SOR 2.8 Earthwork in excavation by mechanical means (Hydraulic excavator)/manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan ) including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50m
SOR 2.8.1 All kind of soil Cum 59.07 360.7
SOR 2.28 Supplying and filling in plinth with sand under floors including watering,ramming consolidating and dressing complete Cum 2.02 287.3
SOR 4.1 Providing and laying in position concrete of specified grade excluding the cost of centring and shuttering all work upto plinth level
SOR 4.1.3 1:2:4(1cement:2 corse sand:4 graded stone aggregate 20mm nominal size Cum 1.44 3998.1
4.2 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc. up to floor five level, excluding the cost of centering, shuttering and finishing:
4.2.3 1:2:4 (1 Cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) cum 5128.3
4.2.5 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) cum 4564.2
4.2.6 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 40mm nominal size) cum 4410
SOR 5.3. Reinforced cement concrete work in beams,suspended floors roofs,having slope upto 15, landing,balconies, shelves, chajjas, lintal, bends,plain window sills stair case,and spiral staircases up to floor five level excluding the cost of centering,shuttering,finishing and reinforcement with 1:2:4 Cum 11.61 5335.9
5.5 Reinforced cement concrete work in arhes, archribs, domes, vaults, shells, folded plate and roofs having slope more than 150 upto floor five level excluding the cost of centring. Shuttering. Finishing and reinforement with 1:2:4(1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) cum 5677.1
5.37 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement
content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
5.33.2 All work from plinth level upto floor V level
5.33.2.2 Concrete of M-30 grade with minimum cement content of 350 kg/cum cum 5989
5.35 Add for using extra cement in the items of design mix over and above the specified cement content therein. quintal
5.9 Centering and shuttering including strutting, propping etc. and removal of form for:
5.9.1 Foundations, footings, bases of columns etc. for mass concrete. Sqm 13.68 211.6
5.9.3 Suspended floors, roofs, landings, balconies and access platform. Sqm 12.34 437.5
5.9.4 Shelves (Cast in situ) sqm 437.5
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. sqm 404.7
5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts. sqm 494.4
5.9.15 Small lintels not exceeding 1.5m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like. sqm 224.2
5.9.19 Weather shade, Chajjas, corbels, etc. including edges. sqm 3.3875 550.9
5.22 Reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete.
5.22.7A Thermo-Mechanically Treated bars TMTC-500-8mm dia Kg 760 56.7 94.5
5.22.7B Thermo-Mechanically Treated bars TMTC-500-10mm dia Kg 500 92.6
5.22.7C Thermo-Mechanically Treated bars TMTC-500-12mm dia Kg 150 90.8
5.22.7D Thermo-Mechanically Treated bars TMTFe-500-16mm dia Kg 91.7
5.22.7E Thermo-Mechanically Treated bars TMT Fe-500-20mm dia Kg 91.7
5.22.7F Thermo-Mechanically Treated bars TMT Fe-500-25mm dia Kg 91.7
SOR 6.1A Brick work with F.P.S bricks of class designation 75 in foundation and plinth in:
SOR 6.1.14A Cement morter 1:6(1 cement : 6 corse sand) Cum 1.74
6.1C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
6.1.14C Cement mortar 1:6(1 cement:6 coarse sand) cum 4923
6.3C Extra for Brick work in superstructure above plinth level upto floor V Level cum 842.2
6.1.14A +6.3A Brick work with bricks of class designation 100A in foundations and plinth in Cement mortar 1:6 (1 cement: 6 coarse sand )
Extra for Brick work in superstructure above plinth level upto floor V cum cum 5662.1
6.18A+ 6.19A Half brick masonry with bricks of class designation 100A in foundations and plinth in :Cement mortar 1:4 (1 cement: 4 coarse send)
Extra for half Brick masonry in superstructure above pinth level upto floor V level sqm 689
6.45 Half brick masonry with non modular fly ash bricks of class designation 10, conforming IS :12894, in superstructure above plinth and upto floor V level.
6.45.2 Cement mortar 1 : 4 (1 cement : 4 coarse sand) sqm 700.8
6.21A Extra for providing and placing in position 2 nos. 6mm dia, MS bars at every third course of half brick masonry (with F.P.S bricks) sqm 113.6
0.9 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
9.1.1 Second class teak wood cum 120526.6
9.1.2 Sal wood cum 0 95670.7
9.53 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) each 72 24
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
9.20.1 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 2845.6
9.21 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
9.21.1 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 1775.3
9.23 Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (over all area of door shutter to be measured) sqm 401.4
9.48 Providing and fixing M.S grills of required pattern in frames of windows etc. with M.S flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.2 Fixed to openings / wooden frames with rawl plugs screws etc. Kg 388.8 161.1
9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. each 10 979.5
9.96 Providing and fixing aluminium sliding door bolts ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with nuts and screws etc. complete:
9.97 Providing and fixing aluminium tower bolts ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
9.97.4 150x10mm Each 58
9.1 Providing and fixing aluminium handles anodised ISI Marked (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete:
9.101 Providing and fixing aluminium hanging floor door stopper ISI Marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour and shade with necessary screws etc. complete.
9.101.2 Twin rubber stopper Each 14 60.8
9.103 Providing and fixing bright finished brass 100mm mortice latch and lock with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS:1868) aluminium lever handles with necessary screws etc. complete (Best make of approved quality). Each 5 655.4
21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 386.1
21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
21.1.2.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) Kg 447.2
21.3 Providing and fixng glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With glass panes of 5.50 mm thickness(weight not less thar 13.75 kg/sqm) Sqm
21.8 Filling the gap in between aluminium frame & adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
21.8.1 Upto 5mm depth and 5 mm width Meter 85.2
9.147B Providing and fixing factory made uPVC white colour fixed glazed windows/ ventilators comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), , uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc.
Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
9.147B.1 Fixed window / ventilator made of (small series) frame 47 x 50 mm & mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area upto 0.75 sqm.) sqm 6690.7
9.147D.1 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc.
Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately) Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.
9.147D.2 Two track two panels sliding window made of (small series)frame 52 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension. (Area of window upto 1.75 sqm) sqm 704.9
10.16 Steelwork inbuilt up tubular (round, squareor rectangular hollowtubes etc.)trussesetc., including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer, including welding and bolted with special shaped washers etc. complete
1O.16.1 Hot finished welded type tubes Kg 11768.98 123.9
10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. Each 22 165.4
10.2 Structural steel work riveted or bolted in built up sections, trusess and framed work, including cutting,hoisting,fixing in position and applying a priming coat of approved ateef primer all complete Kg 95.4
12.5 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. sqm 625.1
12.51 Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15- 18 microns using self drilling/ self tapping screws complete :
12.51.1 Ridges plain (500 - 600mm) rmt. 17.25 396.8
12.51.6 Gutter (600 mm over all girth) rmt. 25.7 898.7
10.32 Steel work welded in built up sections/framed worK including cutting hoisting, rixing in position and applying a priming coat of approved steel primer using structural steel, etc. as required.
10.32.2 In gratings, frames, guard bar, ladders, Kg 114.6
10.33 Providing and fixing hand rail by welding etc. to steel ladder railings & staircases railing including applying apriming coat of approved steel primer
10.33.1 MS tube (medium) 40mm nominal bore Kg 121.9
11.38 Providing and laying Ceramic glazed floor tiles 300x300mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS:15622 of approved make in all colours, shades, except White, Ivory, Grey, Fume Red Brow laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement: 4 Coarse sand) including pointing the joints with white cement and matching pigments etc. complete. sqm 13.740625 862.4
11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS:15622(thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mm thick bed of cement Mortar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. sqm 53.865 795
11.41 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete.
11.41.2 Size of Tile 60x60 cm sqm 1638.8
11.41.3 Size of Tile 800 x 800 mm. sqm 2116.5
11.46 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
11.46.2 Size of Tile 600 x 600 mm. sqm 1191.8
11.46.3 Size of Tile 800 x 800 mm. sqm 1658
11.41 A Providing and laying Vitrified tiles in floor in different sizes {thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only.Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Laying on Toilet floor / Wall
11.41A.2 Glazed vitrified floor tiles polished finish of Size of Tile 600 x 1200 mm sqm 1356
8.2 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.
8.2.2 Granite of any colour and shade
8.2.2.1 Area of slab upto 0.50 sqm sqm 1.37625
8.2.2.2 Area of slab over 0.50 sqm sqm 5.865 4401.2
8.4 Extra for fixing marble/granite stone over and above coresponding basic ite, in facia and drops of width upto 150 mm with expoxy resin based (Araldite or equivalent) adhesive including cleaning etc. complete. m 10
8.5 Extra for providing opening of required size & shape for wash basins/kitchen sink in kitchen platform. Vanity counters and similar location in marble/stone work including necessary holes for pillar taps etc. including rubing and polishing of cut edges etc. complete. each 6 428.2
7.38 Stone tile work for wall lining with special adhesive like araldite or equivalent over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand ) including pointing in white cement with an admixture of pigment to match the stone shade .
7.38.1 8 mm thick (mirror polished and machine cut edge )
7.38.1.1 Granite black stone sqm 1900.9
10.37 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.
10.37.2 Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. Sqm 656
11.26 Kota stone slab flooring over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand )
11.26.1 20 to 25 mm thick sqm 1252.7
11.27 Kota stone slab 25mm thick in risers of steps skirting. Dado & pillars laid on 12mm (average thick cement mortar 1:3( 1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. sqm 1334.9
SOR' 11.72 Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes royalty all complete as per specification and direction of E/I. Per M2 283.3
13.11 12mm cement plaster of mix:
13.11.4 1:6(1 cement: 6 coarse sand) sqm 141.5
13.12 15mm cement plaster on the rough side of single or half brick wall of mix:
13.12.4 1:6(1 cement: 6 course sand) sqm
13.13 20mm cement plaster of mix:
13.13.2 1:4(1 cement: 4 course sand) sqm 209.9
SOR 13.18 15 mm cement plaster 1:3 (1 cement: 3 coarse sand ) finished with a floating coat of neat cement on the rough side of single or half brick wall. Sqm. 5.04 229.3
13.24 6mm cement plaster to ceiling of mix:
13.24.2 1:4( 1 cement: 4 coarse sand) sqm 9.2525 125.6
13.36 Extra for providing and mixing water proofing material in proportion recommended by the manufacturers.
13.36.6 20mm cement plaster 1:4( 1 cement: 4 sand) sqm 10.1
13.37 Extra for plastering exterior walls of height more than 10m form ground level for every add it .irate height of 3 m or part there of sqm 44.4
13.77A Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete. As per manufacture's specifications
13.77A.1 Two or more coats on new work sqm 56.6
13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade:
13.92.1 Two or more coats on new work sqm 86.4
13.95 Painting with aluminum paint of approved brand and manufacture to give an even shade.
13.95.1 Two or more coats on new work Sqm
13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete sqm 105.4
13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface:
13.78.1 Cement primer sqm 38.6
13.79 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
13.79.1 New work (three or more coats) sqm 81.2
13.46A Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade.
13.46A.1 New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 sqm). sqm 132.5
13.81 Applying priming coat:
13.81.1 With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) sqm
13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:
13.93.1 Two or more coats on new work sqm 84.5
13.94 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
13.94.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. sqm 116.5
0.000 French spirit polishing:
13.101.1 Two or more coats on works including a coat of wood filler. Sqm 215.8
15.3 Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead: Cum 1411.2
12.45 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction,
including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutoutsmade with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
12.45.2 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part I sqm 964.9
22.3 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming tc IS 2645 in recommended proportions.(ii) 11 nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion, (iii) Illrd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) Ivth course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni). sqm 10.62 480.6
26A.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the rchitectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS74,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). kg 370.4
26.A.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including:
b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.
c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment , including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture,as per the approved sealant design, within and all around the perimeter for holding glass.d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.
e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified,as per the approved shop drawings and as directed by the Engineerin-Charge.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this subhead. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves ) on the external face shall be measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by BL(National Accreditation Board for Testing and Calibration boratories), Department of Science &Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NBL Certified laboratories
1. Performance Laboratory Test for Air Leakage Test (-50pa to –300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr”2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME-331- 09 testing method for a range up to 2000 ml.”3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range upto 2000 ml”4. Structural Performance Deflection and deformation by static air pressure test (1.5 times desing wind pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm”5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test” Tests to be conducted on site6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000ml” Sqm 3111.4
26A.3 Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Sqm 3377.5
26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’.
The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all Tsections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
26.27.1 With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) Sq.M 18 1832.4
14.72 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. sqm 178.3
12.52X Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.
Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
12.52X.1 GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. Sqm 1348.4
Carriage of Materials with loading & unloading:-
Bricks 100A(local lead 8KM( 1K+7P) excluding Fly Ash brick ‰ No. 0 585 26452 50584
Coarse sand lead By Rail from Koilwar Cum 5.71 20.78 1550.08
Stone chips lead By Rail form Gaya Cum 11.22 0.64 1427.28
Local Sand 3 KM( Lead local 1K+2P) Cum 0 2.29 0
Cement Local Sand 5 KM (P) mt 518.09
Steel Lead 5 KM (P) mt 518.09
Difference Cost of materials :-
Bricks 100A (excluding Fly Ash brick) ‰ No. 0 585 26452 1606.89
Cement(PSC) mt 7.43 6.14
SOR. 17.1 Providing and fixing water closet squatting pan (Indian type W.C pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C flushing cistern with manually controlled device (handle lever) conforming to IS:7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required:
17.1.1 White Vitreous china Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests. Each 2
SOR 17.3 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lif, 10 litre low level white vitreous china flushing cistern & C.P flush bend with fittings & C.I brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
17.3.1 W.C pan with ISI marked white solid plastic seat and lid Each 2 5504.3
SOR 17.31 Provding and fixing 600X450mm beveled edge mirror of superior glass complete with 6mm thick hard board ground fixed to wooden cieats with CP brass screws & washers complete. Each 8 1068.5
SOR 17.10 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required:
SOR 17.10.1. Kitchen sink with drain board
SOR 17.10.1.4 510x1040mm bowl depth 178mm Each 3 5231.5
SOR 17.28 Provding and fixing PVC waste pipe for sink & wash basin including PVC waste fittings complete
17.28.2 Semi rigid pipe
SOR 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall
18.7.2 20 mm Nominal outer dia pipes Metre 3 233.9
18.7.3 25 mm Nominal outer dia pipes Metre 5 317.3
18.7.4 32 mm Nominal outer dia pipes Metre 3 395.2
18.7.5 40 mm Nominal outer dia pipes Metre 12 538.4
SOR 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Concealed work, including cutting chases and making good the
18.8.1 15 mm Nominal outer dia pipes Metre 6 278.2
18.8.2 20 mm Nominal outer dia pipes Metre 13 350.8
18.8.3 25 mm Nominal outer dia pipes Metre 6 463.1
SOR. 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality.
18.17.1 25 mm Nominal bore Each. 1
18.17.3 40 mm Nominal bore Each. 2 707.3
SOR 18.21 Providing and fixing uplasticised PVC connection pipe with brass unions.
18.21.2 45 cm length
18.21.2.1 15 mm Nominal bore Each. 4 85.2
SOR 18.46 Providing and fixing G.I. union in G.I.pipe including cutting and threading the pipe and making long screws etc.
18.46.3 25 mm dia. Nominal bore Each. 1
18.46.5 40 mm dia. Nominal bore Each. 2 419.7
SOR 18.50 Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms.
18.50.1 15 mm Nominal bore Each 3 1242.8
SOR 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m:
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80mm dia but not exceeding 300mm dia Metre 391.7
SOR 19.01 Providing, laying and jointing glazed stoneware pipes class SP-1 'A' with stiff mixture of cement mortar in the proportion of 1:1(1 cement: 1 fine sand) including testing of joints etc. complete.
19.1.2 150mm diameter Metre 2.4 464.3
SOR 19.02 Providing and laying cement concrete 1:5:10( 1 cement: 5 coarse sand:10 graded stone aggregate 40mm nominal size) all-round S.W pipes including bed concrete as per standard design.
19.2.2 150mm diameter S.W pipe Metre 2.4 494.4
SOR 19.4 Providing and fixing square mouth SW gully trap grade A complete with CI grating brick masonry chamber with water tight CI cover with frame of 300X300mm size(inside) the wt. of cover to be not less than4.50kg. And frame to not less than 2.70 kg. as/standard design
19.4.3 180x150mmsize p type
19.4.3.1 With F.P.S. bricks designation 7.5 Each 2 1994.1
SOR 19.6 Providing and laying non -pressure NP2 class R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 including testing of joints etc.
19.6.2 150 mm dia R.C.C. pipe Metr. 410.7
SOR 19.7 Constructing brick masonry manhole in cement mortar 1:4(1 cement: 4 coarse sand) R.C.C top slab with 1:2:4 mix (1 cement:2 coarse sand: 4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement: 4 coarse sand:8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3( 1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design:
19.7.1 Inside size 90x80cm and 45cm deep including C.I cover with frame (light duty) 455x610mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
19.7.1.1 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 Each 1 7914.7
SOR 19.8 Extra for depth for manholes
19.8.1 Size 90x80cm
19.8.1.1 With F.P.S bricks class designation 75 Metre 0.1 5660
SOR 19.15 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design
19.15.1 With 20x20mm square bar Each 8 290.5
SOR 19.18 Supplying and fixing C.I cover without frame for manholes:
SOR 19.18.2 500 mm diameter C.I cover (medium duty) the weiht of he cover to be not less than 58 kg. Each 2 3164.6
SOR 19.30 Constructing brick masonry chamber for underground C.I inspection chamber and bends with 75 class designation bricks in cement mortr 1:4( 1 cement: 4 coarse sand) C.I cover with frame (light duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg(weight of cover 23 kg and weight of frame 15 kg) R.C.C top slab ith 1:2:4 mix ( 1 cement: 2 coarse sand:4 graded stone aggregate 20mm nominal size) foundtion concrete 1:5:10( 1 cement: 5 fine sand:10 graded stone aggregate 40mm nominal size), inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:
19.30.1 Inside dimensions 455x610mm and 45cm deep for single pipe line:
19.30.1.1 With F.P.S bricks Each 4266.8
SOR 19.31 Extra for depth beyond 45cm of brick masonry chamber:
19.31.1 For 455x610mm size
19.31.1.1 With F.P.S bricks Metre 3946.2
D RAIN WATER PIPE
SOR 12.78 Providing and fixing on wall face PVC (working pressure 4kgf per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.78.2 110 mm diameter Metre 24 257.5
SOR 12.79 Providing and fixing on wall face PVC moulded fitting / accessories for rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
12.79.1 Coupler
12.79.2 Single pushfit Coupler:
12.79.3 Single tee with door
12.79.5.2 110 mm bend Each 6 132
SOR 12.80 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised-PVC rain water pipes by means of 50 x 50 x 50 mm hard wood plugs, screwed with M.S screws of required length, including cutting brick work and fixing in cement mortar 1:4( 1 cement: 4 coarse sand) and making good the wall etc. complete.
SOR 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. Each 6 47.9
SOR 24.1 Boring/drilling borewell of required dia for casing/strainer pipe by suitable method prescribed in IS:2800(part-I),including collecting sample from different strata,preparing and submitting strata chart/bore log,including hire & running charges of all equipments,tools,plants and machineries required for the job ,all complete as per direction of engineer in charge,upto 90 metre depth below the ground level
SOR 24.1.1 All type of soil
SOR 24.1.1.1 300 mm dia metre 40 486.8
SOR 24.3 Supplying,assembling,lowering and fixing in virtical position in borewell ,unplasticized PVC mediumnwell casing (CM) pipe of required dia, confirming to IS:12818,including required hire and labour charges,fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
SOR 24.3.2 150 mm nominal dia metre 37 660.1
SOR 24.4 Supplying,assembling,lowering and fixing in virtical position in borewell ,unplasticized PVC medium well screen (RMS) pipes with ribs , confirming to IS:12818,including required hire and labour charges,fittings and accessories etc. all complete, for all depths, as per direction of Engineer-in-charge
SOR 24.4.2 150 mm nominal dia metre 6 673.5
SOR 24.5 Supplying , filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in Recharge Pit,in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3.18
SOR 24.6 Supplying , filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the Recharge Pit,over the existing layer boulders in the required thickness ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3
SOR 24.7 Supplying , filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm, in the Recharge Pit, in the required thickness over gravel layer ,for all leads & lifts, . all complete as per direction of Engineer-in-charge cu-m 3
SOR 24.13 Providing & fixing suitable size thre platebto top of borewell housing/casing pipe,removable as per requirement all complete for borewell of
SOR 24.13.2 150 mm dia each 1 210.7
SOR 24.14 Providing & fixing MS clamp of required dia to the top of housing/casing pipe of,removable as pe tubewell as per IS;2800(part-I), including necessary bolts & nuts of required size complete
SOR 24.14.2 150 mm clamp each 1 1531.4
SOR 24.15 Providing & fixing Bail plug/ bottom plug of required dia to the bottom of pipe assembly as per IS;2800(part-I),
9 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
9.2 Single headed Stainless steel Each 1 5722
17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following asrequired.
20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585
20 mm nominal internal dia gun metal globe valve & nozzle.
Drum and brackets for fixing the equipmets on wall.
Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
16 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
16.2 Stainless steel (Grade 304) Each 2 4445
18 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
18.2 Stainless steel (Grade 304) Each 1 1631
13 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Each 1 1236
Civil 18.59 Providing and fixing C.I. double acting air valves of approved quality with bolts, nuts, rubber insertions etc. complete ( The tail pieces, tapers etc. if reqd. will be paid separately)
14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
14.7 150 mm dia Each 1 15398
11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
11.6 150 mm dia Each 1 8241
SUBHEAD-II (B):PIPING FOR FIRE FIGHTING SYSTEM
7 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : (Above Ground)
Threaded joint upto 50mm diameter pipe.
Welded joint above 50mm diameter pipe.
7.8 150 mm nominal bore (class C) Rm 3 1856
7.7 100 mm nominal bore (class C) Rm 3 1316
7.6 80 mm nominal bore (class C) Rm 5 951
7.5 65 mm nominal bore (class C) Rm 5 832
7.4 50 mm nominal bore (class C) Rm 6 646
7.3 40 mm nominal bore (class C) Rm 3 509
7.2 32 mm nominal bore (class C) Rm 6 417
7.1 25 mm nominal bore (class C) Rm 60 359
21 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories
21.3 Horizontal side wall sprinkler Each 0 0
21.1 Pendent type Sprinkler Each 25 408
21.2 Upright type sprinkler Each 0 408
22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Each 1 1442
25 Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required.
29 Providing, installation, testing & commissioning of adjustable rosette plate for 15mm dia in white finish UL Listed or FM approved complete as required. Each 1 167
Add 5.357 % GST on SOR Item as per BCD
DSR 25 17.1 Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity Authority Regulations and CPWD Specifications as amended up to date, consisting of Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control, protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real time online web interfaced Data Monitoring System, Distribution panels, grid connecting arrangement, conduits, pipes, cable trays and other accessories etc. as required. a) High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV module used in any solar power project must have Radio frequency identification tag with information such as name of manufacturer, month and year of manufacturing, country of origin (separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module, Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
b)Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum IP 21 for indoor, Built-in
meter and data logger, MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter shall be capable of complete automatic operation including wake-up, synchronization & shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with shutdown/standby mode. It must be provided with grid islanding along with manual disconnect pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and other protections as per applicable standards. LCD/LED display of minimum parameters: DC input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase), Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters applicable standard. Communication interface RS 485 / RS 232.
c) Module mounting structure: The roof top solar plant generation units shall be installed by using supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 ) having minimum head room clearance of 2.4 meter above the terrace level / ground level. The mounting structure would be designed to sustain wind load and seismic parameter of the site of installation. All the structure shall be design as per applicable BIS code and the material shall also confirm the applicable BIS Code. Structural material shall be corrosion resistant and electrolytically compatible with the materials used in the module frame, its fasteners, nuts and bolts. The suitable arrangements for maintenance and cleaning shall be provided.
d) Real time online web interfaced Data Monitoring System complete with accessories for various parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle, Power produced and other parameters as per standard practices.
e) Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. Each junction box shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes, isolation switches isolate the DC input to Inverter, copper bus bar etc.
f) Lightning, surge voltage protection, earthing protection and grid islanding.
g) Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other accessories etc. as required.
h) DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded, having copper bus bar, having required protection and control gears, connection-interconnection, etc. as required. (Inclusive of all compents i.e solar plate, frame, inverter, earthing, wiring, bidirectional meter, apply and obtaining NOC from electrical inspector,all necessary item and liasioning with SBPSCL for commissioning and intergrating the system with grid system) (Make- Vikram, Adani, Novasys , Luminous or approved equivalent as per approval of EIC) KWp 25 54280
Electrical work Make As per BSR Approved Make list as approved by Engineer in Charge
8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. Each 8 2482
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate/,switch box including connections but excluding modular plate etc. as required Each 8 358
8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
8.17.1 300 mm sweep Each 3 2572
8.19 Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required. Each 8 3670
5.9 Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required. Each 21 2663
5.3 Supplying and fixing 4'x20 watt LED batten with minimum efficacy 100lm/w in aluminoum housing and complete with integrated electronic driver etc. directly on ceiling / wall including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor single core cable etc. as required. Each 6 762
5.7 Supplying and fixing recess mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
5.7.3 12 watt Each 48 1224
1.34 Supplying and fixing batten / angle holder including connections etc. as required. Each 8 80
6.1 Supplying and fixing following types lamp in existing electrical fitting/ fixture etc as required.
6.1.6 15 watt LED lamp Each 8 250
1.33 Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ wooden block including connection etc as required. Each 9 64
1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps moduler socket outlet & 6A modular type switch connection etc. as required. Point 17 414
1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/ 16 amps moduler socket outlet & 15/16A modular type switch connection etc. as required. Point 11 531
1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. Each 6 683
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.1 5/6 amps switch Each 28 20
1.24.4 3 pin , 5/6 amps socket outlet(For wall fan only) Each 8 28
1.24.6 Telephone socket outlet Each 8 131
1.24.7 TV antenna socket outlet Each 1 131
1.27 Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular switches/ socket/TV / Telephone outlet in surface/ recess etc. as required.
1.27.1 75mmX75mmX50mm Each 234
MP PWD 38.4 Supply, installation testing and commissioning of telephone tag block krone connector with enclosure complete as mentioned below
MP PWD 38.4.1 10 Pair Each 1
1.26 Supplying and fixing modular blanking plate on the existing modular plate & metal box excluding modular plate, etc. as required. Each 10 34
Supplying and fixing metal/ PVC box of following sizes ( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in the front including painting etc. as required.
1.22.1 75mmX75mmX60mm deep Each 4 139
1.22.6 200mmX150mmX60mm deep Each 2 276
1.3 Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit with modular switch , modular plate suitable size G.I. box etc as required.
1.3.3 Group C Point 90 1146
Wiring for group controlled (looped) light point/ fan point/ exhaust fan point / call bell point (without independent Switch etc.) with 1.5 Sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit etc as required.
1.59.3 Group C Point 12 609
1.5 Wiring for power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No.4 sq mm FR PVC insulated copper conductor single core cable for loop earthing as required Meter 340 309
1.7 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Meter 246
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire Meter 70 150
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire Meter 150
Supplying & fixing of following size medium class PVC conduit along with accessories in surface/ recess including cutting of wall and making good the same in case of recessed conduit as required.
1.21.1 20 mm dia Meter 102
1.21.2 25 mm dia Meter 20 120
1.17 Supplying and drawing co-axial W cable RG-6 grade, 0.7mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed PVC conduit as required. Meter 20 42
1.16 Supplying and drawing following pair 0.5 sq. mm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed PVC conduit as required.
1.16.2 2 Pair Meter 160 31
MP PWD 38.3 Supply installation, testingand commissioningof 0.5mm size solid annealed copper, jelly filled telephone cables, polythene insulated, petroleum jelly filledwithpoly-al laminatemoisturebarrier, polythene sheathed, armoured polythene jacketed telephone cables as per DOT specifications of following sizes
MP PWD 38.3.1 10 Pair Meter 30
MAIN PANEL & D.B.s
2.9 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus -bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.9.1 4 way ( 4 + 12 ), Double door, horizontal type Each 2 4148
2.9.2 6 way ( 4 + 18 ), Double door, horizontal type Each 1 5132
2.32 Supplying and fixing cable end box ( Loose wire box , IP 43) suitable for following sheet steel M.C.B. Distribution board, on surface/ recess, complete with testing commissioning etc. as required
2.32.4 For 4 way Double door MCB TPN DB Each 1 1064
2.32.5 For 6 way Double door MCB TPN DB Each 1 1111
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
2.12.1 6 Amp. To 32 Amp. SP MCB 240 Volt Each 72 237
2.12.4 32 Amp TPN MCB 415 Volt Each 1282
2.12.8 40/63 Amp TPN MCB 415 Volt Each 2329
2.14 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. Each 5 13
Providing and fixing of following rating electrical items in existing cubical panel including drilling holes in if required, making connections etc. as required .
2.7.7 250 A four pole ON-load panel mounted changeover switch Each 1 21415
COMPUTER NETWORK
1.58.1 Supplying and drawing of UTP 4 Pair CAT-6 LAN cable in the existing surface / recessed PVC concuit etc. as required. Meter 52
1.56 Supplying and fixing suitable size GI box with moduler base & cover plate in front on surface or in recess including providing and fixing of 3nos 5 pin 5/6 amps socket outlet and 2 nos 5/6A moduler switch connection etc. as required. Set 40 778
DSR 2025 39.14 Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required. Each 80 212
DSR 2025 39.11 Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel. 24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required. Each 2 5278
DSR 2025 39.12 Supplying, Installation, Testing and commissioning of following CAT6 Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
39.12.1 Copper Patch Cords of length 1m (3ft) Each 40 151
39.12.2 Copper Patch Cords of length 3m (10ft) Each 80 227
DSR 2025 39.23 Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
39.23.1 6U Rack Each 6939
39.23.2 9U Rack Each 2 8960
DSR 2025 39.3 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
39.3.2 24 port Layer 2 Non-PoE Network Switch Each 2 86163
DSR EnM 2025 39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
i 39.1.2 8 port Layer 2 Non-PoE Network Switch Each 6 28073
DSR 2025 39.7 Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for Low Density use having features and specifications etc. as mentioned here under - Dual-band Wi-Fi6 (802.11ax) 574Mbps (2.4GHz) + 1200Mbps (5GHz), WI-FI 6 Certified, 1 x RJ45 console port, 1G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2- PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Should also work as Standalone and must be Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required. Each 6 22739
DSR 2025 39.16 Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required Each 80 9
DSR 2025 39.19 Supplying and drawing following core Fiber Optic Cable having corrugated steel armoring. The Fiber should be SM Fiber Central -loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature shall be – 5 0C to +50 0C, Max Attenuation ± 0.36 (db / km) at Operational Wavelength 1310 nm and ± 0.22 db / km at Operational Wavelength 1550 nm. type of fiber should be 9/125 / G.652D & Refractive Index should be 1.4670/1.4675. The value for Mode-filed, Cladding Diameter 9.2 ± 0.4 μm and 125 ± 0.7 μm correspondingly. The Dispersion value < 3.5 < 18 ps/nm-km and PMD value < 0.2 ps/km and Cable Cutoff wavelength < 1260 nm i/c splicing & marking etc complete as required.
i 39.19.1 Single Mode 6 Core Optical fiber cable Meter 100 64
DSR EnM 2025 40.3 Supplying Installation Testing and Commissioning of 4MP IP IR Dome Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
DSR EnM 2025 40.3 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps , Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
DSR EnM 2025 40.3 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
i 40.3.1 4MP @ 25/30fps@1440P (2560 x 1440) Dome Camera with 2.8/ 3.6/ 6/8/12 mm fixed lens (as per site requirement). Each 30 10365
DSR EnM 2025 40.4 Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: > 50 dB,Camera should display Camera title, Date & Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4, AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
DSR EnM 2025 40.4 3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming , configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion, Motion Detection 8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card. 10) Recording Management: Format SD, overwrite, storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
DSR EnM 2025 40.4 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body 19) Operating Condition:- Ambient Temperature:- (- )05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
40.4.1 4MP @ 25/30fps@1440P (2560 x 1440) Outdoor Bullet Camera with 2.8/ 3.6/6/8/12 mm fixed lens (as per site requirement) Each 10 10063
DSR EnM 2025 40.11 Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned below : 1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0)
DSR EnM 2025 40.11 8) Video Output Ports: 2x HDMI and 2 VGA 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS, TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply.
DSR EnM 2025 40.11 15) Operating Condition : -5°C to 50°C, humidity 90% (max) (non-condensing) 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF
DSR EnM 2025 40.11 22) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page 23) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of alarm and a list of camera that is configured to record upon alarm 24) It should have Web and GUI interface. 25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection
DSR EnM 2025 40.11 26) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries & regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception
DSR EnM 2025 40.11 30) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics 34) Analytics by NVR: Perimeter protection and face recognation
i 40.11.2 64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16 Each 1 82600
DSR EnM 2025 40.12 Supplying, Installation, Testing and Commissioning following capacity Serveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200 RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL Certifications.
40.12.1 4TB (Terabytes) Each 8 13943
MP PWD 54.27.1 + GST 8 port PoE switch with 2 SFP ports Supply, installation testing and commissioning of 8 port PoE switch with 2 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP cat. 5, cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 40 GBPS, maximum 64 bytes packet forwarding rate, 14.88 MBPS, ports 1 to 8 compliant with 802.3at Each 8 27168.32
MP PWD 54.28.1 + GST 24 port PoE switch with 4 SFP ports Supply, installation testing and commissioning of 24 port PoE switch with 4 SFP ports, having security features like port security supports 64 MACs per port, auto surveillance VLAN, loopback detection automatically disables a port when a loop is detected, cable diagnostics allows administrators to determine cable status, UTP Cat. 5, Cat. 5e (100 m max.), full/half-duplex for 10/100 MBPS, full-duplex for 1000 MBPS, auto MDI/MDIX adjustment for all twisted-pair ports, switching capacity, 56 GBPS, maximum 64 bytes packet forwarding rate, 41.7mbps, Ports 1 to 24 compliant with 802.3 at Each 1
DSR EnM 2025 39.1 Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: Minimum 8 X RJ-45 Gigabit Ethernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP, MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP, TLS, TTLS, PEAP Support) Cable Diagnostic feature, LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c, v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
39.1.1 8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+. Each 35091
DSR EnM 2025 39.3 Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required.
i 39.3.1 24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port supporting 802.3at PoE+ min. Each 125393
42.4 Supplying, Installation, Testing and Commissioning of following size LED display (LED monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits or better, Video wall mode should be available, contrast ratio: 1200:1, OPS slot, viewing angle (H/V): 170°/ 170°, response time less than 12ms, Display control shall be on monitor screen and programmable with remote (remote shall be supplied with system), Key Board, Optical Mouse, etc. as required.(Make-Samsung/LG/Dell/HP or Approved Equivalent)
42.4.3 55 inch or larger Each 1 82057
Make-Mahindra /Kirloskar/Cummins or Approved Equivalent
DSR EnM 2025 29.1 Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing, test report OEM manual,Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
DSR EnM 2025 29.1 (A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS 10000, IS 10002, IS 13018 and as per CPWD specifications.
DSR EnM 2025 29.1 (B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following: (i) Start-stop switch with key (ii) Water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and Voltage indication (vi) RPM indication (vii) Over speed indication (viii) Low lubricantion Oil trip indication (ix) Engine Running Hours indication (x) Fuel Level
DSR EnM 2025 29.1 (C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50% RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
DSR EnM 2025 29.1 (D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. (E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications.
DSR EnM 2025 29.1 F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor. (G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside the acoustic enclosure of DG Set.
DSR EnM 2025 29.1 (H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65 protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
DSR EnM 2025 29.1 (I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power (aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
DSR EnM 2025 29.1 1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for O/C & E/F and shunt trip. 2. Auto/Manual/Test/Off selector switch 3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay). 4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering 5. Energy analyser unit to indicate current, Voltage( LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF. 6. LED Indicating lamps for load on mains and load on set 7. Fuse/ MCB for instruments 8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
DSR EnM 2025 29.1 9. Main supply failure monitor 10. Supply failure timer 11. Restoration timer 12. Control unit with three impulse automatic engine start/stop and failure to start lockout. 13. Impulse counter with locking and reset facility. 14. ON/OFF/Control circuit switch with indicator 15. Audio/Video annunciation for (i) High water temperature (ii) Low lubricating oil pressure (iii) Engine over speed (iv) Engine fails to start (v) Full load/maximum load warning
DSR EnM 2025 29.1 16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories 17. Maintenance notification based on Engine Run Hour & due date. 18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel , interlocking providing signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and necessary hardware and software required to perform the operation shall be provided by the contractor including all control wiring.
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.15 240 sq. mm, 3.5 core Meter 50 2228
7.1 Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as reqd.
7.1.4 Above 185 sq. mm and upto 400 sq. mm Meter 60 368
7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.4 Above 185 sq. mm and upto 400 sq. mm (Clamped with 40 x 3 mm MS flat clamp) Meter 10 171
0.9 Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. Cum 5 242
0.0 Filling available excavated earth (excluding rock) in trenches, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 metres. Cum 3 155
9.14 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. In the existing trench, complete as required.
9.14.5 200 mm dia (OD-200 mm & ID-175 mm nominal) Meter 10 572
DSR EnM 2025 10.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required
10.5.4 Above 185 sq. mm. and upto 400 sq.mm M 10 170
DSR EnM 2025 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as reguired.
3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. Set 2 13721
3.10 Supplying and laying 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode, including connection with brass nut, bolt, spring, washer excavation and refilling etc. as required. Meter 60 1628
3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. Meter 60 144
3.2 Earthling with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. Set 2 6323
3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. Set 2 6884
3.11 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. Meter 30 721
3.7 Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble as required. Meter 100 37
3.16 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. Meter 30 53
4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.l. tube, having single prong at top, with 85 mm dia 6 mm thick G.l' base plate including holes etc. complete as required. Each 8 416
4.3 Fixing of lightning conductor finial (single prong) with base plate including holes etc. as required Each 8 224
4.4 Jointing copper/ G.l. tape (with another copper/ G ltape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. Each 8 81
4.7 Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) Metre 50 102
4.8 Providing and fixing G.l. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) Metre 240 145
4.4 Riverting and sweating and soldering of copper /G.I. tape (with another copper /G. I. tape, base of the finial or any other metallic object ) as required. Each 8 81
4.12 Providing and fixing testing joint made of 20x3mm thick GI 125 mm long with 4 nos of bolts nut and spring washer etc complete as required . Each 8 102
1.15 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ reeessed PVC conduit as required.
1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1.24.1 5/6 amps switch Each 28 82
8.14 Supply and fixing extra down rod for ceiling fan of 1 metre length G.l. pipe, 15 mm dia, heavy guage including painting etc. as required. Each 8 409
2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts,on surfac / recess, complete with tinned copper bus bar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCBilsolator)
2.8.7 12 way, Double door Each 1 2314
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required'
2.12.2 6A to 32 A, SP&N Each 1 606
2.25 Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth,metal enclosed plug top alongwith 20 amps "C" curve,TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required. Each 2 3008
8.11 Supply and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley, internal wiring, earth terminals, Bus bar Chamber, insulator and complete in all respect etc and panel manufactures must be approved by CPRI. (But without RYB inicator, ammeter, voltmeter, inter-connection copper conductor cable/solid copper strip, switchgears etc.) SQFT 36 1809
8.13 Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc as required. Each 2 6536
2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required' (Make- LK, Legrand, ABB, Schneider or approved equivalent as per approval of EIC)
2.4.5 250 A,36 KA, FPMCCB Each 2 18646
2.4.1 l00 A, 30 KA, FPMCCB Each 8172
2.12 Supptying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
2.12.8 40 A to 63 A, TP&N Each 2329
2.12.1 6 A to 32 A, Single pole Each 4 237
1826 (A.R) 32 mm X 6 mm copper tape ( 1.705 kg/mtr) kg 10 820
1101 (A.R) 1.5 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 25 24
1103 (A.R) 4.0 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 140 56
1107 (A.R) 25 sq. mm lSl marked, FRLS PVC insulated single core copper conductor cable Metre 40 411
2.33 Supplying and fixing , following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 160 amp, four pole MCCB as lncomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBS)
2.33.2 6 way, Double door, l/C 160A , MCCB Each 1 13710
DSR 25 4.1 Supplying and installaton following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required.
4.1.2 150 mm width X 50 mm depth X 1.6 mm thickness Metre 40 686
4.1.4 300 mm width X 50 mm depth X 1.6 mm thickness Metre 40 866
3.21 Providing chemical/mineral maintenance free earthing system comprising of copper coated earth electrode 3 metre length and 17.2 mm outer dia along with 25 kg earth conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth and earth inspection pit etc. as required. Set 4 16675
3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. Metre 20 1180
3.15 Providing and fixing 25 mm X 5 mm G.l. strip on surface or in recess for connections etc. as required. Metre 20 195
Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,lP 65 protection and complete u.,ith integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. Each 8 1275
7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.9 50 sq. mm, 3.5 core Metre 50 561
7.7.12 120 sq. mm, 3.5 core Metre 20 1186
2.5 Providing and fixing following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty, complete with all accessories including connections, earthing the body etc. as required.
DSR 25 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
DSR 25 26.1 Online UPS - Input supply: Single Phase, Output Supply: Single Phase. (Make- Vertiv, APC, Numeric or approved equivalent as per approval of EIC)
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE.
The operating efficiency of the UPS systems shall be >95% at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 & 3) .
The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc
MP PWD 42.84 + GST Supply and fixing transformer breather with silica gel suitable for 100 -500 KVA as reqd . Each 1
MP PWD 42.85 + GST Supply and filling of new transformer oil of desired break down value for topping as reqd. Ltr 100
MP PWD 42.86 + GST Filtration of transformer oil for 33/0.4 KV, 11/0.4 KV 3 phase 50 cycle oil immersed, naturally cooled, distribution transformer upto desired break down value. Ltr 150
DSR 25 2623 Eye Hook Each 8 32
DSR 25 28.1.4 Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. Each 6 444
DSR 25 28.1.7 Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. Each 6 530
DSR 25 28.1.9 Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required.
DSR 25 28.5.2 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS/HFFR outer sheath complete as required. MTR 105 192
Analysis Rate Cutting making conceling and finishing the pre existing wiring of each floor job 4 7786
Make-Carrier/Toshiba /O-General/Mistubishi or Approved Equivalent
1 SPLIT AC (inverter model, Cooling only) :- Supply, installation, testing and commissioning of Split type wall mounted air conditioning unit of following capacity including indoor, outdoor unit fitted with inverter based rotary compressor, copper condenser and first charge refrigerant R410A. The condensing unit working range should be capable for providing cooling between +/-5 deg. C to SO deg. C & heating within 'b deg. C to 15 deg. C including connection of copper pipe of required size upto 3 mtr., insulation, cordless remote control, auto air swing louvers, connection copper lead wire, condensed water outlet pipe 2 mtr. complete etc as required. Outdoor/ indoor units should be of same make (brand). The cost includes contractor profit, labour cess, supply, transportation cost, installation, testing and commisioning cost.
1.1 1.5 TR, 5 star Each 1 58500
3 Supply installation testing and commissioning of Atomatic Voltage Stabilizer of Capacity 4 KVA, input voltage -130V± 10% and output-220 V ± 10% of Capacity & input Range 130V to 280V Model (For 1.5 Ton AC) Each 1 4800
6 Refrigerant:- Supply and additional refrigerant charge of refrigerant R410/410A & equivalent Eco friendly green gas to compensate the additional piping done at site for all systems including testing commissioning as required, kg 25 1695
7 Drain piping :- Providing and fixing of CPVC, 6Kg/cm2 drain water piping with fittings, support and insulated with 6 mm thick closed cell elastomeric nitrile rubber insulation complete as per specification.
7.2 25 mm dia ID Meter 30 238
7.3 32 mm dia ID Meter 30 350
9 Copper piping: - Supply, installation, testing and commissioning of interconnecting copper refrigerant pipe work (19mm/13mm thick) duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications. And exposed piping should be wrapped with glass woven cloth and lag coating for vapour barrier and weather protection. Joints shall be covered with nitrile rubber tape of 3 mm thick complete as per specification.
9.4 34.9 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Meter 20 50
9.5 31.8 mm O.D. wall thickness ≥ 1.4mm (insulation – 19 mm thick) Meter 50 36
9.6 28.6 mm O.D. wall thickness ≥ 1.2mm (insulation – 19 mm thick) Meter 30 1640
9.8 22.2 mm O.D. wall thickness ≥ 1.0mm (insulation – 19 mm thick) Meter 50 31
9.9 19.1 mm O.D. wall thickness ≥ 1.0mm (insulation – 13 mm thick) Meter 10 20
9.1 15.9 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 10 1031
9.11 12.7 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 10 813
9.12 9.5 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 80 693
9.13 6.4 mm O.D. wall thickness ≥ 0.8mm (insulation – 13 mm thick) Meter 80 560
10 VRV/VRF outdoor AC unit:- Supply installation testing and commissioning of VRV /VRF /MRV outdoor units with following multiple inverter based scroll type compressors, electronic expansion valve, R 410A/ecofriendly green refrigerant, cooling & heating mode both options, special pre-coated fin type heat exchanger, low noise direct driven propeller condenser fans in each module with top discharge including internal wiring, microprocessor controls, safety. The condensing unit should be capable of providing cooling between +/- 5deg. C. to 48 deg. C & heating within 0 deg. C to 15 deg. C, COP not less than 3.3. Each system should have the provision to combine maximum 3 nos compressor in each outdoor unit, every single outdoor unit should not have more than maximum Capacity 20 HP (3 phase) each compressor complete as per specification. Outdoor/indoor units should be of same make (brand). (Single phase/three phase)
12 VRF/VRV indoor AC unit (ceiling mounted 4 way):- Supply installation testing and commissioning of 4 way round flow ceiling suspended/mounted cassette type unit comprising of copper evaporator, electronic expansion valve, blower, motor, filter pad, auto air swing louvers, temperature &on/off display with inbuilt drain pump & decorative panels including internal wiring, controls. Dimension in terms of length & width should not be more than 950mmX 950mm with wireless remote controller. (Single phase/three phase)
16 Y joints:- Supply, installation, testing & commissioning of ref nut/Y-joints brass for indoor and outdoor units of suitable size as per requirement, Each 5 6490
27 Controlcable: - Supply and laying, testing & commissioning of following sizes of shielded copper conductor Communication cables on existing tray including fixing clamps & proper connections to equipment etc. complete as required.
2Cx1.5 sq.mm Meter 58 300
(Re-Tender) उद्यमिता विकास संस्थान (IED), बिहार, पटना के Upgradation/ Renovation का कार्य |
Infrastructure Development Authority, Govt. of Bihar
NON SCHEDULE ITEMS
SL.NO DESCRIPTION UNIT Civil PHE RWH ELEC AC Furniture Reno. Work Fire Solar Power Lift Total Qty. Quoted Rate In Figure (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Rate In Word (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect) Quoted Amount (Rs.) (the quoted rate should be inclusive of all Taxes/cess, Royalty, Seignorage fee, Carriage of materials, Transporation cost of all materials from sources to work site, all overheads etc. complete in all respect)
1 MR WALL PANELLING TYPE-1 (120mm BWP Board+ Veneer Application)
P/F Wall panelling with 12 mm thick BWP Board firmly fixed to the wall, and covered with3mm thick veneer of the given shade / colour / texture / approved equivalent, in approved pattern. The laminate may have a number of horizontal and vertical grooves / patterns / beadings as per designs and drawings. Integrating electrical points as per Electrical Drawings and design in existing wall panelling, and cuting and making good any damages is included in the scope of this item, as per instructions of the Project Engineer.
All items necessary for completing the above mentioned work are deemed to be included in the scope of work, whether or not they are specifically mentioned in the B.O.Q / tender documents / drawings.
All complete as per drawings, designs, specifications and directions of Engineer-in-Charge. (Make-Century / Green/ Merino ) sqm
MR Providing and Fixing horizontal level suspended metal ceilings comprising of Metalworks V-P 500 Hook-on baffle system manufactured by Knauf Ceiling Solutions with Rectangular vertical baffle blades made of Aluminium (Grade AA 3xxx, H14 temper) in coated thickness of 0.7mm ± 0.08mm as per IS:2676 (1981), post coated to Global White colour, suitable for architectural finishes and Interior applications, with single grid system and suitable spacing between baffles. The baffle width shall be 50mm, height shall be 100mm, length shall be 3000mm. The on-center spacing of baffles shall be 150mm (clear space between baffles 100mm). The baffles shall have plain unperforated finish with square edge, hook-on edges with suitable upturns. The baffles shall be electrostatically powder coated using RoHS compliant pure polyester powder to achieve coating thickness ranging from 60-80 microns.
The powder coating shall pass Salt Spray Test for 750 Hours as per ASTM B117, QUV –A Test for 1000hours as per ASTM G-154 – (Cycle – 1) and Humidity test for 1000hours as per DIN 50017. The powder coating shall have an adhesion of GT0 as per EN ISO 2409. The shade variation across batches shall be delta E<1 using Excite/BYK Gardner instrument and gloss level of 25±5% at 60˚ as per ASTM D523. The grids shall comprise primary U-shaped slotted carrier bars of 120gsm galvanised steel (GI) of 3000mm L x 43mm H x 30mm W x 1.5mm T. Accessories shall include baffle connector (GI), baffle face cover (GI) – RAL shade, carrier bar splice (GI), carrier spring (SS), wall anchor (GI). sqm 10
NS-2 Supplying fitting and fixing of Marvel /Hunter Douglas/D'decor Make Roller Blinds as per company specification and as per approved colour and sample inclusive of all taxes and royalty all complete as per specifications / approval and direction of Engineer-in-Charge. Sqm
MR Provding and fixing white vitreous urinal (Jaquar URS-WHT-132530) or equivalent with Aquisense Sensor concealed type flushing valve for Urinal complete set with installation box with control cock ,(jaquar CAT NO- SNR-STL-51087) etc. all complete. Each 6
MR Providing and fixing Curved shaped urinal partition with frosted glass finish: Chrome, size-900 H X 450 W (jaguar-JSE-CHR-110UC450X) or equivalent Glass: 10mm as per direction of Engineer-in-charge and finished smooth. Each 6
MR Providing and fixing counter basin size- (mm) 190x550x430 (Jaquar,CAT NO- FLS-wht-5701) including fixing and all accessories as per manufacturers specification and direction of Engineer-in-charge. Each 8
MR Provding and fixing PVC Soil ,Waste & vent pipes all complete
110 mm dia metre 42
40 mm dia metre 28
MR Provding and fixing PVC fittings all complete as/specification & directionof E/I
110 mm vent cowel Each 4
110 mm plain bend Each 1
110 mm door bend Each 1
110 mm dia X 45 Bend Each 5
110 X 110 mm dia plain - y Each 8
110 X 110 mm dia door tee Each 4
110 X 110 mm dia plain tee Each 1
110 mm pipe clip Each 13
110 X110 mm dia p-trap Each 10
40 mm elbow Each 28
40 mm plain tee Each 14
MR Providing Paper holder (jaguar AKP-35753PS) or Equivalent Each 2
MR Providing Towel Ring (Jaquar product No. AKP-35751P ) or equivalent Each 5
MR Soap dispenser (jaguar AKP-35735P) or equivalent Each 8
MR CP brass 2-way bib cock with wall flange(Kubix-F) 15mm(jaguar -KUP-35041PM) or equivalent Each 4
MR 110 mm dia cp jali Each 10
MR Providing & Fixing angle stop cock ,15 mm dia nominal bore (Jaquar -KUP-35053PM) or equivalent Each 4
MP SOR 2024 57.3 Supply, installation, testing & commissioning of water cooler with eco friendly refrigerant IN-SITUPUF Instalation Anti-corrosive body with storage of required capacity (Make-Voltas/Bluestar/Ion Exchange or Approved Equivalent)
57.3.2 Water cooler 40 liter Each 2
MP SOR 2024 57.4 Supply, installation, testing & commissioning of domestic water purifire having RO+UV+MTDS with one number prefilter having minimumwater purifying capacity of 16 liters per hour storage.installation type wall mountined/table top- stable for hardenss upto 2000mg/l operatig input voltage 150-250V AC/50 HZ (Make-Voltas/Bluestar/Ion Exchange/Aquaguard/Kent or Approved Equivalent) Each 2
MR PeopleLink or Approved Equivalent Signage Podium - Ultra
Supply Installation testing and commissioning of following ● Metallic Body with Top Sliding Mechanism ● Visualiser Tray ● Rack for Equipments ● 21.5 inches Touch Screen Monitor ● Laptop Interface with inbuilt switcher ● Gooseneck Mic(2), Wireless lapel Mic and handheld mic, ● 200 Watts DSP, ● Speaker Pair ● Central Control System with Button Pad Projector, Screen, Audio and Video Control ● 32" Signage4-microphone array 4-meter radius pickup, 85dB speaker volume,Noise reduction, echo cancellation, multi connectivity (USB, Bluetooth, 2.4G), LINE IN/OUT, extension unit support, three-party call, built-in rechargeable battery. Each 6
MR Supply Installation testing and commissioning of 75 " Interactive Display Board with Infrared Touch (40 touch Point) Input HDMI X 3 , USB-2.0 X 1 , USB 3.0-X1 Touch x 2 , USB C Type x2 (65 W) OUTPUT- HDMI OUT X 1 ,AUDIO OUT X 1, SPDIF X 1, RJ45 OUT X 1 OS Android 13/14 , RAM- 8 GB ROM 128 GB Make - MAXHUB or Approved Equivalent Each 3
MR Supply Installation testing and commissioning of 98 " Interactive Whiteboard with Interactive kit and cable like USB, Power Cable etc Make Benq / Edutek or Approved Equivalent Each 4
SHIFTING OF VRF OUTDOOR UNIT OF FIRST FLOOR TO FOURTH FLOOR
Dismantaling of 32 HP VRF outdoor Unit after necessary doing the Refrigerant back up and other work. Nos. 2
Lifting & shifting of 32 HP outdoor Unit to the Mummty of Lift & staircase including all required labour & machnary. Nos. 2
Installtion charge of 32 HP VRF Outdoor Unit with all required labour & fixing materials with anti vibration pad. Nos. 2
PCC Foundation work for the fixing of 32 HP VRF Outdoor Unit to sufficient the load carrying and proper size. Nos. 2
Copper piping of required size with tubular Insulation & with Communication cabling work with all required materials & labour. Job 2
Flushing & Leak testing with dry nitrogen of the refrigerant system with all required material & labour. Job 2
Commissioning of the system & Refrigerant charging as required. Job 2
Durian Study Table or approved equivalent in Steelcase / Usha Lexus / Wipro Study Table - TABLE TOP IN 18MM THICK PRELAMINATED BOARD WITH UNDERSTRACTURE MADE OF POWDER COATED SINGLE UNIT WITH METAL MESH SHELF FOR BOOKS TABLE SIZE: 700MML X 450MMD X 740MMH. * SCRATCHPROOF EASY WIPE TOP * METAL SHELF & WIRE SHELF WITH BAG HOOK * DURABLE ,STRONG & SAFE. Each 21
Durian Study Chair or approved equivalent in Steelcase / Usha Lexus / Wipro Durian Study Chair - CHAIR SIZE: 355MML X 381MMD X 780MMH. FIBER SEAT* SCRATCHPROOF EASY WIPE TOP SUPPORTED WITH UNDERSTRACTURE MADE OF POWDER COATED. Each 42
Durian DWS/MESS/TB or approved equivalent in Steelcase / Usha Lexus / Wipro Canteen Table - Canteen Table Size-(1200x800x750)mm table with ISO Top/Corian table supported with MS squire pipe legs the MS legs will be duly poweder coated . Each 4
Durian PJ013259 or approved equivalent in Steelcase / Usha Lexus / Wipro Dining Chair - Chair Size 525mm x 845mm x 558mm. Seat Height 450mm. Injection moulded plastic for seat and back increases rigidity and flexibility for the user Understructure has options of both MS and SS 202 grade tube Optimal Scale of the product increases comfort for all user types Absence of narrow grooves and ribs makes the maintenance of product easy Stackable design (4 chairs a stack) and ability of inverse placement on table comes in handy during maintenance of the room Retro-fit cushioned upholstery cover provided as an option makes sitting for longer durations easy Chair parts are UV stabilized as required for indoor applications to reduce colour fading effect. Each 16
Durian DWS/4800 or approved equivalent in Steelcase / Usha Lexus / Wipro Meeting Table (4800X900X750)mm- Meeting Table - Meeting Table Size L-7600 X 1500 X750MM. An all wood Durian conference table with minimalist look and basic functionality, ideal for meeting room & top comes with 40mm thik pre lam particle board & side panel 25mm thick prelam particle board & 2mm pvc edge banding with modesty given much needed ptimary and close interaction. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Black Oak. Each 1
Durian PJ0015/HB or approved equivalent in Steelcase / Usha Lexus / Wipro High Back Chair with revolving Size(W)590mm X (D)505mm X (H)1280mm. Chrome plated base with gas height adjustment and central tilting with single locking machenaism. Armrest with padding. Durian Leatherette uphlostery has the look and feel of top grain leather. Cushion wtih lumber support for all day comfort. Chrome plated loop armrest with padded upholstery for extra comfort. chair rotates a full 360 degree in either direction for ease of motion. Standard on every executive & controls rate and ease with which chair reclines to different weight and strengths of users. Quick and easy adjustment regulated height of chair relative to floor. Look out tilt function when chair is in upright position. 5% post consumed recycled content & 30% total recycled content. Color-Black. Each
Durian PJ0015/MB or approved equivalent in Steelcase / Usha Lexus / Wipro Medium Back Chair - Durian Chair Size Medium back leatherette chair in black colour with matte finish specification : durian- office seating- craze chair , type : * low back 360ø degree revolving chair, * all over size is : 660mm Lx 505mm Dx 1105mm H , *the chair made of full leatherette in black colour . it will comes in matte black finish finsih in contemporary style . details : * arms : chrome finish arms with pu padding . * use of ply: 12 mm thick hot pressed bwr plywood is grade - 303 for seat and back . * seat: 40 ñ 2 mm thick polyurethane foam with density 32 ñ3 kg per cu meter for best quality cushioning in seat , * back : 40 ñ 2 mm thick polyurethane foam with density 32 ñ3 kg per cu meter for best quality cushioning in back . backrest support foam design based on symmetrical lumbar support * mechanism : knee tilt mechanism . * only seat size is 525mm Lx 525mm Dx 610mm H & the back size is 660mm Lx 570mm H seat maximum height is 610mm & minimum height is 510mm & back height from floor maximum height is 1105mm & minimum height is 1005mm * gas lift 100 mm telescopic haudraulic * base : 650 mm chrome base with smooth castors. Each 16
Durian DWS/WS/1200 or approved equivalent in Steelcase / Usha Lexus / Wipro Workstation- Size (1200x600x1200)mm. ·67mm thk Sliding Tile Based Partition. Single Metal raceway cover at skirting level in Partition. Pin up & white board in partition above the tabletop. Table top made of 25mm thk Prelamin particle board with pvc edges. Pedestal of 350Lx 450Dx725 HT (2 drawer + 1filling). PVC Keyboard Tray . Metal CPU Trolley. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Each 24
Durian DWS/900/STORAGE or approved equivalent in Steelcase / Usha Lexus / Wipro Storage Cabinet- 2 Door Back Storage- Size (900x400x1050)mm. Storage top made of 25mm thk and side of 15mm thk Prelamin particle board. Storage with openable shutter with 2 shelves and lock. Storge top & shutter color will be maple and storage side & skirting color will be Dark gray. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Maple & Dark Gray. Each 30
PJ008/MB/STD or approved equivalent in Steelcase / Usha Lexus / Wipro Medium Back Chair - Chair Size (W)580mm X (D)670mm X (H)1110mm. Its Classic All-Black Look With Soft Black Fabric Upholstery Makes It An Irresistible Chair. The Deep-Cushioned Back And Seat Conform To The Natural Curvature Of The Spine For Optimum Ergonomics And Lumbar Support. The Synchro-Single Locking Mechanism Along With The Tilt Tension Control, Lets You Find Your Ergonomic Position With Ease. The Pneumatic Height Adjustment Along With The Sturdy Armrest Provide Further Comfort. A Strong Nylon Base Supports The Structure, While The 55Mm Castor Wheels And A 360-Degree Swivel Provide Swift Yet Stable Movement. Each 24
Durian DWS/1500/SU or approved equivalent in Steelcase / Usha Lexus / Wipro Table with side unit return- Table Size(1500x750x750)mm & Side runner Size(750x400x750)mm. Table made of 25mm thk pre lam particle board with edge banding. Table top supported with side panel & fron panel. Kyeboard tray & cpu trolly. Table top with wire manager & interchangable side runner with fixed pedestal of 3 drawers. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Each 2
Durian MMPL/011/VC or approved equivalent in Steelcase / Usha Lexus / Wipro Visitor Chair - Chair Size (W)590mm X (D)490mm X (H)980mm. Its moulded seat and indented back provide exceptional all-day support. Premium virgin foam sits atop a 14mm thick boiling waterproof plywood forming the moulded seat. This is then encased in deep black fabric upholstery with defined line seams that provide comfortable seating while adding depth to the high backrest. The powder-coated metal cantilever base provides extraordinary support for easy seating. Each 4
Durian DWS/1200/STORAGE or approved equivalent in Steelcase / Usha Lexus / Wipro Storage Cabinet- 2 Door Back Storage- Size (1200x400x750)mm. Storage top made of 25mm thk and side of 15mm thk Prelamin particle board. Storage with openable shutter with 2 shelves and lock. Storge top & shutter color will be maple and storage side & skirting color will be Dark gray. Phenol bond using in Pre-Laminated Particle Board & Edge band thickness will be start from 2mm for Top & 1mm for rest parts. Our PLPB certified from ISI grade & Termite, Borer & Fungus resistance laminated outside in selected color & inside (Non Visible Part) will be balancing white. 100% European design & texture & 100% Product Consistency, fade resistance lamination best International Technology. Color-Maple & Dark Gray. Each 2
M.R. Providing and fixing carbon-di-oxide type fire extinguishers consisting of welded M.S. cylindrical body, internal discharge tube, discharge nozzle, suspension bracket, conforming to IS 2878, finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.
Capacity 4.5 kg Nos. 3
M.R. Providing & Fixing of stored pressure Fire Extinguisher ABC powder type (Mono Ammonium Phosphate Powder) Magnetic Pressure Gauge having the facility to check at site, Discharge Time less than 9 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 21A, B Rating 55B as per BS EN-3 BIS 15683 marked, Can Construction : Deep drawn & CO2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating ofCan : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, Helium LeakDetection Tested, Warranty.
Capacity 6 Kg. Nos. 3
M.R. Providing and fixing angle iron (40 mm x 40 mm x 5 mm) MS door frame 900x2100 door capable of accommodating fire hose reel, landing valve, hose pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for making 900x600x2100 Recessed type mansoary box (by civil contractor). Each 1
M.R. Providing and fixing of Fire Axe. Though the axes are to be tested to 20 000 volts their use should be limited to 1000 to 2 000 volts with precautions.. Each 1
M.R. Providing, fixing, testing and commissioning of full way level operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not lass than 15 kg/sq.cm with threaded/flanged complete with nuts, bolts, gaskets, washers etc. as required complete as per direction of Engineer incharge.
25 mm NB Each 1
M.R. Shifting of Fire-Fighting Pipes & Pumps Service
Providing all labour, materials, tools, and equipment for shifting the existing fire-fighting pipes from their present location on the terrace to any location as directed by the Engineer-in-Charge (E/I), complete in all respects.
The work shall include:
Making all necessary openings, cutting, extensions, or laying of new pipes, as required. Providing and fixing all accessories, specials, supports, and fittings. Executing all associated civil works and making good the disturbed surfaces to their original condition. Shutting down and restoring the water supply system as required to complete the work including repairing and serivicing pre existing pump and pipeline if required. The work shall be executed as per the directions of the E/I and shall ensure the fully functional relocation of the system complete, and shall ensure that the Fire Fighting System is fully functional and operational. Job 1
Extension of preexisting lift for 1 floor including commissiong and making lift in working condition Lift extension will be done by OEM of Pre Installed Lift only
5 L-A1, PWI13/16-19 5stops at present (Extension of 01 Floor)
Elevator Type Passenger elevator PWI13/16-19 Product IMonospace Technical Platform I MonoSpace No of Units 1 Load & Capacity 884 kg or 13 persons Speed 1.6 m/s Stops & Openings 5 stops & 5 openings, Single entrance car (at present) 01 Stops EXTENSTION (Expected 06 Openings) Total no of opening 1 entrances Travel height 14.8 m Elevator Grouping Simplex Full Collective Control Elevator main safety standard EN81-1 Well Dimension 2200 mm width and 2180 mm depth (required) Head Room height 4200 mm (required) Pit Height 1525 mm (required) MAP Floor Position Topmost floor (TOP) Car dimensions 1600 mm wide x 1350 mm deep x 2200 mm high Door dimensions 900 mm wide x 2000 mm internal height Door type Two-panel centre opening Plain Panel Each 1
Dismantling of Lift Job 1
Comprehensive AMC for 3 years from OEM
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
SBD NIT 08.pdf
NIT • 3.54 MB
08TEN2026_0001.pdf
NIT • 2.64 MB
08TEN2026_0001.pdf
NIT • 2.64 MB
SBD NIT 08.pdf
NIT • 3.54 MB
TB NIT 08 IED.xlsx
NIT • 0.02 MB
FB NIT 08 IED.xls
NIT • 0.41 MB
FB NIT 08 IED.xls
NIT • 0.41 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .