| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 CrAdmitted-Finance | ₹5.3 Cr | L1 | Admitted-Finance |
| 2 | Rejected-Technical | - | - | Rejected-Technical Non Responsive |
| Sl No | Description | Qty | Unit | FUTURISTIC GLOBAL RESOURCES PVT LTD L1 |
|---|---|---|---|---|
| 1.00Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140mm/150mm dia and then enlarging to required diameter direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site. | ||||
| 2.00Drilling of 140/150mm pilot bore | ||||
| 3.00 | Upto 60m depth below ground level
TWAD SoR P.No - 302 (11 NOSX60M)=660M | 660 | Rmts | 1,698 ₹11,20,680 Lowest |
| 4.00 | From 60m to 90m depth ending from ground level.
TWAD SoR P.No - 302 (11 NOSX30M)=330M | 330 | Rmts | 1,839 ₹6,06,870 Lowest |
| 5.00 | From 90m to 120m depth ending from ground level.
TWAD SoR P.No - 302 (11 NOSX30M)=330M | 330 | Rmts | 1,950 ₹6,43,500 Lowest |
| 6.00 | From 120m to 130m depth ending from ground level.
TWAD SoR P.No - 302 (11 NOSX10M)=110M | 110 | Rmts | 2,052 ₹2,25,720 Lowest |
| 7.00Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the Engineer. | ||||
| 8.00 | Upto 60m depth below ground level
TWAD SoR P.No - 302 (11 NOSX60M)=660M | 660 | Rmts | 427 ₹2,81,820 Lowest |
| 9.00 | From 60m to 90m depth ending from ground level.
TWAD SoR P.No - 302 (11 NOSX30M)=330M | 330 | Rmts | 453 ₹1,49,490 Lowest |
| 10.00 | From 90m to 120m depth ending from ground level.
TWAD SoR P.No - 302 (11 NOSX30M)=330M | 330 | Rmts | 483 ₹1,59,390 Lowest |
Tender Value
Refer Docs
EMD Value
₹7 L
Closing Date
3 Feb 2023, 3:00 pmClosed
Executive Officer Nemili Town panchayat
5/1, Panapakkam Road, Nemili Town Panchayat
Ranipet District Amruit 2.0 Improvement of water supply in Nemili Town Panchayat
2022_DTP_274081_1
70/2022
Open Tender
Civil Works
Works
365 days
Nemili Town Panchayat Office
Class I contractor
2 documents required · 2 mandatory
₹0
₹7 L
Yes
29 Apr 2023
21 Dec 2022
3 Feb 2023
22 Dec 2022
3 Feb 2023
22 Dec 2022
22 Dec 2022 - 3 Feb 2023
Amount
Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140mm/150mm dia and then enlarging to required diameter direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site.
Drilling of 140/150mm pilot bore
Upto 60m depth below ground level TWAD SoR P.No - 302 (11 NOSX60M)=660M
From 60m to 90m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX30M)=330M
From 90m to 120m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX30M)=330M
From 120m to 130m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX10M)=110M
Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the Engineer.
Upto 60m depth below ground level TWAD SoR P.No - 302 (11 NOSX60M)=660M
From 60m to 90m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX30M)=330M
From 90m to 120m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX30M)=330M
From 120m to 130m depth ending from ground level. TWAD SoR P.No - 302 (11 NOSX10M)=110M
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete supply and packing the annular space with pebbles of size and quality as approved by the Engineer. TWAD SoR P.No - 304
200mm dia casing pipes assembly(11NOSx130M)=1430M
Charges for developing the Borewell with air compressor of 600 CFM capacity (Minimum 8 Hours) including transportation, labour and fuel charges for compressor and conducting yield test by 'V' Notch method.etc complete as directed by the Engineer. TWAD SoR P.No - 305
Supplying of PVC CASING PIPE AS PER IS 12818 / 2010 200 mm dia CM TWAD SoR P.No - 22(PLAIN PVC CASING PIPE)
Supplying of PVC CASING PIPE AS PER IS 12818 / 2010 200 mm dia CM TWAD SoR P.No - 22(SHARTING PVC CASING PIPE)
Labour charges for the erection of submersible pumpset in borewell/open well including fixing and jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. TWAD SoR P.No - 308
Upto 5 HP
Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mm x 4mm alround covered with 16 gauges MS sheet and Kiosk door made up of MS plates of size 25mm x 3mm including cutting, welding, grinding, locking arrangements and labour charges etc., complete. TWAD P.No - 89
Supply and delivery of clear water vertical wet type submersible pumpset suitable for not less than 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. Rated capable of discharging noted LPM against head of water column due to all causes.The pump shall be with stainless steel shaft and dynamically balanced bronze or Cast SS impeller, brass screws and CI FG 200 grade pump bowl/diffuser with ISI mark. The pump shall be directly coupled to a continous rated two pole suitable wet type vertical squirrel cage induction motor as per IS9283 /1995 as amended there after, suitable for operation in AC three phase 415 V+/- 10 %, 50 HZ +/- 5 % TWAD SoR P.No - 103,3.1,50
150 lpm against a total head of 142 m (150LPMx120MHEAD)
THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with 7.5 HP or Suitable rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) including Ammeter, Voltmeter, Thermal Overload relay, 16 Amps 2 pole Magnetic Contactor with under Voltage protection, Indication lamp, starting capacitor, running capacitor and On/Off Push button switches, 5 way connector, wiring with 1 sq. mm/1.5 sq. mm copper PVC insulated cable, powder coated vermin proof box including the capacitor (the cost of capacitor is to be taken separately). TWAD SoR P.No - 114,
a.7.5 HP or Suitable capacity b.5.0 HP or Suitable capacity
Supply, delivery, erection, testing and commissioning of following sizes of power shunt capacitor for power factor improvement, suitable to operate on 415V, 3Ph,50Hz A/C supply, on suitable angle iron frame-works (37.5 mm x 37.5 mm x 6.24mm ) at a height of 0.25m from the ground, including earthing and incidental civil works etc., complete. TWAD SoR P.No -
1 KVAR TWAD SoR P.No - 124
Supplying and fixing of following capacity Triple Pole fuse carrier in MS Sheet steel encloure with provision for accommodating the TNEB meter including earthing etc., complete as per TANGEDCO which includes LT meter panel board TWAD SoR P.No - 125,16.1
Supplying and fixing of following capacity Triple Pole SFU with fuses on suitable angle iron frame with earth connection only. TWAD SoR P.No - 199,4.a
PVC INSULATED AND SHEATHED 3 CORE FLAT TYPE COPPER CABLE CONFORMING TO IS 694/1990 AND AS AMENDED THEREAFTER. TWAD SoR P.No - 120
DO - 3 core 4 sq.mm - Pump (PS)
Supplying and fixing of cable gland and termination with Aluminium cable lugs for following PVC UG cable and with earth connection TWAD SoR P.No -121,12.2,1
DO - 3 core 4 sq.mm
DO - 4 core 4 sq.mm
Supply, delivery and erection of Three Phase 4 way 32 Amps, 10kA LDB with the following: 1 No of 40 A FP isolator for incoming supply 3 Nos. of 16A, DP RCCB 3 Nos. of 16A, SP MCB 1 No of 16A, DP MCB 3 Nos of 6A, DP MCB in sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete.
Run of 2 of 1.5 sq mm PVC unsheathed copper single core cable in PVC pipe for mains with continuous earth connection by 14 SWG wire From the MCB DB to the Switch boards in office, store,and 16A power socket.
Supply, conveying and fixing GI specials as per the latest revision of IS 1239 including with ISI markings on it including earthwork excavation, lowering into the trenches, aligning, refilling the trenches with excavated soil, watering and ramming to consolidation, etc. TWAD SoR P.No - 44
50 mm G.I Elbow
50 mm GI Coupling
50 mm GI Union
50 mm MS Clamp Set
Supply, conveying and fixing following GI pipes as per latest revision of IS 1239 with ISI markings TWAD SoR P.No - 44
50 mm G.I pipe (11nosx200m from bore well inner pipe to OHT inlet)
Supplying, delivery and installation at site, conveying and fixing the GM valves as per IS 5154 with ISI marking including loading, transportation charges and stacking etc complete as per specifications TWAD SoR P.No - 45
50mm GM valve
Supplying, delivery and installation at site, conveying and fixing the GM Reflux valves as per IS 5154 with ISI marking including loading, transportation charges and stacking etc complete as per specifications TWAD SoR P.No - 45
50 mm dia GM non-return valve
Earth work excavation and depositing on bank with an initial lead of 10m and initial lift of 2m
Hard stiff clay,stiff black cotton soil, hard red earth, shales, murams, gravel, stoney earth, and earth mixed with 50% fair size boulders and hard gravelly soil -SS20B
Supply and filling the foundation and basement with m sand in layers complying with standard specification including consolidation and watering etc. complete and as directed by Departmental Engineers. TP Data
Levelling course with P.C.C 1:4:8 (one cement, four sand and eigth course aggregate) using 40 mm H.B.G stone including mixing concrete, laying, curing and compacting of concrete etc., complete and as directed by the Departmental Engineers. TP Data
Brick work in CM 1:5 (one cement and six sand) using country bricks of size 8.75" X 4.25" X 2.00" including cost of all materials, labour charges, curing etc., complete for Superstructure and as directed Departmental Engineers. TP Data
Reinforced cement concrete 1:1.5:3 (one cement, one and half sand, three course aggregate) using 20mm size hard blue granite stone (machine crushed) for beam and roof slab excluding cost of reinforcement, fabrication and placing the grills in position and excluding cost of centering, shuttering, strutting but including curing and finishing mixing concrete using machanical mixer machine and compaction by machanical vibrator etc., complete and as directed by Departmental Engineerss. TP Data
Centering for sides and soffits of R.C.C slab of plane surface for R.C.C floor slab including strutting upto 3.3 mt height using MS sheets of size 90cmx60cm and stiffend with welded MS angle of size 25mmx25mmx3mm laid over silver oak (country wood) joists of size 10cmx6.5cm (space at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia 90cmx60cm and BG10 guage (spaced at 75cm c/c) complying with standard specification etc., complete as directed by the Departmental Engineers. TP Data
Column
Roof slab
Others
Plastering with CM 1:5 (one cement and five sand) 12mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by dept officers. TP Data
Supplying fabricating and placing in position of RTS grills at all heights for reinforcement including cost of steel for all works and labour charges including cost of binding wire etc., complete for all RCC works and as directed by Departmental Engineers. TP Data
Floor finsihing with CM 1:3(one cement and three sand) 20mm thick including cost of materials, labour charges for finishing, curing etc., complete and as directed by Departmental Engineers. TP Data
Special ceiling plastering with CM 1:3 (one cement and three sand) 10 mm thick including labour charges for mixing, finishing , curing etc., complete and as directed by Departmental Engineers. TP Data
White washing two coats using fine screened shell lime for the new plastered surface for inner and outer side of the room including the cost of materials labour charges etc., complete and as directed by Departmental Engineers. TP Data
Colour washing two coats with approved colour and quality over two coats of white washing for outside of the room including the cost of materials, labour charges, cleaning and preparation of the surface and curing etc., complete and as directed by Departmental Engineers. TP Data
Supplying and fixing of steel Doors two leaves including all cost , with fitting etc complete as directed by dept officers (the design should be got approved by the SE before supply & fixing)1x2.1m TP Data door and window
Weathering course with broken Brick Jelly of 20 mm size in pure slaked lime (no sand to be used) over RCC Roof slab with proportion being 32:12 1/2 for required depth of 80mm thickness over the roof slab as required well beaten with wooden beaters for giving required slope complying with standard specification etc., complete and as directed by dept officers.
Terrace Flooring with two course of flat tiles using of size 200mmx200mmx20mm laid in CM 1:3(one cement and three sand) mixed with crude oil to 10% by weight of cement and pointed neatly with the same oiled morter etc., complete complying with standard specification and as directed by dept officers. TP Data
Refilling with excavated earth (other than sand) complying with standard specifications for filling the foundations including watering & consolidation etc. complete as directed by dept officers. TWAD SoR P.No - 286
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVC power plug point. (SD-38)
Supply and fixing of 1200 mm (48") AC ceiling fan complete with stepped electronic 300W regulator with 1meter down rod on the existing clamp. (SD-106)
Supply and Fixing of WT Bulk Head Fitting with guard (Philips / Bajaj / K. Lite) Suitable for 11W CFL Lamp with CFL (SD-82)
Supply and fixng of TNEB Meter Board suitable for 3 Phases 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 200A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete - SD 130
Supplying of DI K7 Pipes of following dia , conforming to IS 8329-2000 including all local and central taxes , transportation, freight charges, loading and unloading, conveyance to site and stacking the same, cost of all labour, material & etc complete. TWAD SoR,P.No - 47
100 mm Dia DI K9
Supply & Delivery to site of the following types of specials such as Tees, Tapers. Bends, endcaps etc as per specification. TWAD SoR P.No - 52
Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16 TWAD SoR P.No - 71
100mm dia DI Sluice valve
Manufacture, Supply and Delivery of Tamper proof DI single chamber double orifice, triple function (ventilating, admitting and venting during operation) air release valves with pressure range from PN 1.0 to 2.5 with body and cover made of Ductile Iron of Grade GGG 40 or equivalent grade conforming to IS 1865 with Food Grade Epoxy Powder coating(EP-P) inside and for outside of colour blue RAL 5005. All internal parts such as float, shell etc.,cover bolts, made of Austenitic alloy steel of SS AISI 304/316. The float shall be made of Polytetrafluroethylene/ Austenitic alloy steel of AISI 304/316. Gaskets and seals of EPDM / Neoprene rubber for TWAD Board works anywhere in Tamil Nadu and with 5 years TWAD SoR P.No - 71
50mm dia DI air valve
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow.The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”.Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished.
100mm dia
Earthwork excavation
Earthwork - Excavating and storingg on bank with an initial lead of 10 m and initial lift of 2 m in trenches for laying of pipes etc. all complete as per standard specifications and as directed by the Departmental Engineer. Ordinary Soil - such as Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small boulders and hard gravelly soil etc., TWAD SoR P.No - 295
100 mm Dia DI K9
Barricading work (Where the lines are in narrow width of municipality area,busy streets like Market, Bus-stand and in the Highways etc.) for laying ofpipe line using casurina poles at 1.50m center to center (8cm to 10cm dia.and 1.80m height) vertical with horizontal poles in two rows, painting thevertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including supplying, delivery and fixing of GI sheet (0.90m x 0.8mm thick) in the horizontal poles and fixing75mm dia. reflectors including earth work excavation for fixing verticalposts and finally removing and stacking the materials safely for further useetc., complete and as directed by dept officers. TWAD SoR No - 323
Lowering of DI pipes and specials carefully into the trench and laying to proper grade and alignment including labour charges, incidental and operational charges etc complete as per standard specifications and as directed by the Departmental Engineer. TWAD SOR P.No - 258
100 mm Dia DI K7
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) TWAD SoR No - 261 & 262
100 mm Dia DI K9
Testing of pipes for water supply with hydraulic testing equipment by filling with water (including cost of water) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test,excluding the cost of pipes but including other incidential and operational charges etc.,complete for the following diametres of pipes. TWAD SoR No - 270
100 mm Dia DI K9
Refilling or backfilling trenches with excavated soil after pipe laying in layers not exceeding 20 cm in depth, ramming and consolidation of each layer, watering etc. all complete as per standard specifications and as directed by the Departmental Engineer. TWAD SoR No - 295
100 mm Dia DI K9
Plain Cement Concrete 1:2:4 (one cement, two fine aggregates and four coarse aggregates) using 20mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges etc., complete as per standard specification Data
100 mm Dia DI K9
Construction of Brick work valve Chamber with M20 Grade concrete . The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of the pit, PCC M10 for Blinding Concrete, Brick work in CM 1:5 and plastering with CM 1:5 - 12mm thick, cost of steel reinforcement fabrication charges, Cover slab with manhole cover etc., and fixing the valves in position inside the pit including laying, jointing of valves, HDPE pipes and specials including the cost of jointing materials such as bolts and nuts RI sheets washers etc., complete and as directed by the Departmental Engineer.
For sluice Valves chamber Size - 1.0m x 1.0m x 1.5 m
Supply & Delivery of the following dia of HDPE pipe of PE 100 grade, PN -6 class conforming to IS 4984 including all local and central taxes , transportation, freight charges, loading and unloading, conveyance to site and stacking the same, cost of all labour, material & etc complete. TWAD SoR - P.No - 29
HDPE Pipes of 90 mm diameter
HDPE Pipes of 110 mm diameter
HDPE Pipes of 125 mm diameter
HDPE Pipes of 140 mm diameter
HDPE Pipes of 160 mm diameter
HDPE Pipes of 180 mm diameter
Supplying of DI K7 Pipes of following dia , conforming to IS 8329-2000 including all local and central taxes , transportation, freight charges, loading and unloading, conveyance to site and stacking the same, cost of all labour, material & etc complete. TWAD SoR,P.No - 46
200 mm Dia DI K7 pipes
Supply & Delivery to site of the following types of specials such as Tees, Tapers. Bends, endcaps etc as per specification. TWAD SoR P.No - 32
90 mm dia HDPE bends
90 mm dia HDPE Tees
110 mm dia HDPE bends
110 mm dia HDPE Tees
125 mm dia HDPE bends
125 mm dia HDPE Tees
140 mm dia HDPE bends
140 mm dia HDPE Tees
160 mm dia HDPE bends
160 mm dia HDPE Tees
180 mm dia HDPE bends
180 mm dia HDPE Tees
Earthwork excavation
Earthwork - Excavating and storingg on bank with an initial lead of 10 m and initial lift of 2 m in trenches for laying of pipes etc. all complete as per standard specifications and as directed by the Departmental Engineer. Ordinary Soil - such as Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small boulders and hard gravelly soil etc., TWAD SoR No - 295
HDPE pipes from 90mm dia upto 160mm dia
HDPE Pipes of 180 mm diameter
200 mm Dia DI K7 pipes
Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height) vertical with horizontal poles in three rows including painting the vertical poles in the road facing sides with ready mix paint, tying the vertical and horizontal poles with coir rope including fixing charges and fixing 75mm diareflectors including earth work excavation for fixing vertical posts and finally removing and stacking the materials safely for further use etc., complete and as directed by Dept officers. TWAD SoR No - 323
Lowering the following dia of pipes and specials into trench and laying to proper grade and alignment complete as per standard specifications and as directed by the Departmental Engineer. TWAD SoR P.No - 268
For 90mm to 110mm dia (OD) HDPE pipes
For 125mm dia (OD) HDPE pipe
For 140mm dia (OD) HDPE pipe
For 160mm dia (OD) HDPE pipe
For 180mm dia (OD) HDPE pipe
Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the dept officers. TWAD SoR No - 258
200 mm Dia DI K7 pipes
Jointing HDPE Pipes and Specials of the following dia of pipes by butt fusion welding / electro fusion welding joints using fusion equipment as per ISO 21307-2011 and as per IS 7634 (part-2) : 2012 including cost of hire charges for butt fusion equipment power supply arrangements etc., complete as per directed byTWAD Board Officers. TWAD SoR P.No - 279
90 mm diameter pipes,Tees & Bends
110 mm diameter pipes,Tees & Bends
125 mm diameter pipes,Tees & Bends
140 mm diameter pipes,Tees & Bends
160 mm diameter pipes,Tees & Bends
1801 mm diameter pipes,Tees & Bends
Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials) TWAD SoR No - 261 & 262
200 mm Dia DI K7 pipes
Testing of D.I/HDPE pipes for water supply with hydraulic testing equipment by filling with water (including cost of water @ Rs. 60/KL) and testing to recommended pressure in convenient stretches and attending the bursts if any occured during the test, excluding the cost of pipes but including other incidential and operational charges etc., complete for the following diametres of pipes. TWAD SoR P.No - 270
HDPE Pipes of 90 mm diameter
HDPE Pipes of 110 mm diameter
HDPE Pipes of 125 mm diameter
HDPE Pipes of 140 mm diameter
HDPE Pipes of 160 mm diameter
HDPE Pipes of 180 mm diameter
200 mm Dia DI K7 pipes
Refilling or backfilling trenches with excavated soil after pipe laying in layers not exceeding 20 cm in depth, ramming and consolidation of each layer, watering etc. all complete as per standard specifications and as directed by the Departmental Enginee. TWAD SoR P.No - 296
HDPE Pipes of 90 mm diameter
HDPE Pipes of 110 mm diameter
HDPE Pipes of 125 mm diameter
HDPE Pipes of 140 mm diameter
HDPE Pipes of 160 mm diameter
HDPE Pipes of 180 mm diameter
200 mm Dia DI K7 pipes
Road restoration
Supply and delivery of DI D/F Gate sluice valves (soft seated) resilient seated soft sealing Gate Valves(Sluice Valves) with body Bonnet of Ductile cast iron ofGrade GGG 40 or equivalent grade,Wedge fully rubber lined with EPDM replaceable spindle nut without gland packing and with 3 ORing protection on the shaft and seals of NBR and the valves should be of Vacuum tight and 100% leak proof with face to face dimensions as per BS 5163-89/ISI 4846-2000/DIN 3202 F4. All the valves should be with electrostatic powder coating both inside and out side with pocket less straight through body passage. All the valves are to be compatible for buried application withpressure rating PN 10/16 . TWAD SoR P.No - 71
80mm DI Sluice valve
100mm DI Sluice valve
150mm DI Sluice valve
200mm DI Sluice valve
Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished. TWAD SoR P.No - 87
100 mm dia
Supply & delivery of following DUCTILE IRON SPECIALS AS PER IS 9523/2000 for valve in the distribution system as per IS standards TWAD SoR P.No - 52
Specials for Sluice valve - 300.00 Kgs Specials for Electromagnetic bulk Water meter - 80.00 Kgs
Construction of Brick work valve Chamber with M20 Grade concrete . The rate should include earth work excavation in various soils met with at the site of work, refilling the pit after the construction of the pit, PCC M10 for Blinding Concrete, Brick work in CM 1:5 and plastering with CM 1:5 - 12mm thick, cost of steel reinforcement fabrication charges, Cover slab with manhole cover etc., and fixing the valves in position inside the pit including laying, jointing of valves, HDPE pipes and specials including the cost of jointing materials such as bolts and nuts RI sheets washers etc., complete and as directed by the Departmental Engineer- Data
Sluice valve Chamber Size 1.0m x 1.0m x 1.5m
Electromagnetic flow meter chamber Size 1.0m x 1.0m x 1.5m
Providing House service connection with suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around including road cutting, replacement of utilities, providing house service connection, refilling, restoration of roads / drains, testing etc complete with the following materials Data
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .