Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-Finance 33 JAGGI GARDEN NARAINGARH ROAD AMBALA CITY 134003 | AMBALA | HARYANA | 134003 | L1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L2₹35.4 L+₹87,100 (2.52%)Rejected-Finance | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L3₹36.8 L+₹2.2 L (6.39%)Rejected-Finance | L3 | Rejected-Finance GREATER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹79,000
Closing Date
27 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
ADDN ALTN AND SPL REPAIR TO ROOF OF BUILDING NO P 159 AND SPL REPAIR TO ROOF OF BLDG NO P 95 AND P 106 AT INS SHIVAJI LONAVALA
2021_MES_429410_1
GE/LONAVLA/8979/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹79,000
Yes
30 Mar 2021
9 Mar 2021
29 Mar 2021
9 Mar 2021
27 Mar 2021
15 Mar 2021
10 Mar 2021 - 14 Mar 2021
60 days
Amount
Dismantling Mangalore pattern roofing tiles single layer including ridge tiles.
Dismantling battens for tiles any size exceeding 15cm in spacing.
Dismantling wooden fillets in rafter purlins etc unframed work under 40 sq cm in sections.
Dismantling of CGI/PGI sheet roofing any gauge and any thickness including ridge, valley gutter etc.
Dismantling boarding any description fixed in any position fixed with nails.
Dismantling timber scantling of framed work 40 sq.cm and over in section and in any position.
S&F Roof trusses (framed) , trussed, purlin, crane gantries, rails including distance pieces , cleats etc. conforming to Fe 410-w (Gde -E-250) quality -A complete all as specified.
M&L for prefabricated puf roofing panel with one side manglore pattern sheet & other side plain sheet with slight rib of 0.60mm TCT PPGI (Off white RAL 9002) with 60mm core of polyurethene foam of density 40 Kg/M3 (+2 Kg/M3) fixed with self tapping screws all as per manufacturer's instructions including all cutting as required as per site conditions having following specifications complete all as specified and as directed. (a) Top Sheet - Profile as approved by GE. (b) Bottom Sheet - Plain sheet with slight ribs. (c) Panel thickness - 50 mm. (d) Facing material - 300 Mpa Galvalume steel with 150 GMS Aluminium Zinc Coating. (e) Facing material thickness - 0.6 mm TCT. (f) Facing material coating - DFT 20 microns colour coated RMP/SMP/PVDF coating over 5 micron primer.
S&F Pre painted galvalume aluminium zinc coating GI based plain steel sheeting 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,eave boards fixed with self tapping screws complete all as specified and as directed.
M&L cement concrete 1:2:4 type B-1using 20mm graded stone aggregate as in holdfast blocks all as specified
Demolition of stone/brick work built in cement mortar.
M/L for brick work with subclass 'B' bricks, straight, or curved on plan exc 6m mean radius built in CM 1:4
M&L for Preparation of new surface of steel and applying two coats of synthetic enamel paint over a coat of red oxide primer
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Rendering in CM (1:6) 15mm thick on fair faces of brick work or stone surfaces finished even and smooth in patches (without using extra lime or cement) and finish the surface with 3mm thick wall care putty
Rendering in cement mortar 1:4 15mm thick (10mm as doubing coat and 5mm in finishing coat using water proofing compound on brick/ stone surfaces finished fair and even without using extra cement etc complete all as specified and directed.Note : Water proofing compound and will be measured and paid separately.
Supply only integral water proofing compound.
Preparation new plstered surface of wall and applying two coats of plastic emulsion paint over a coat of alkali resistant primimg paint .
Preparing newly plastered surfaces of walls & applying two coats of antifugal acrylic base exterior weather proof paint over a coat of primer on external surfaces of wall all as specified and directed
S&F 0.60mm thick corrugated galvanised mild steel sheeting with zinc coating of 120 gram/SqM, grade 'O' with two corrugation side lap, with corrugation of grade 'B' 12.5mm depth fixed with 'L' type or 'J' type or cranked hook bolts and washers in roofs, walls etc.
S&F 1.00 mm thick plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings(length and girth as fixed) , boarding with zinc coating 120 gram/SqM grade 'O'. Note :- Plain area will be measured for payments irrespective of curve/velly
S/F Tubular sections of size 50 x 25 as in rafters fixed with self tapping screw of size not less than 75mm and 25 x 25 for battens fixed on rafter over CGI sheet roof with necessary fittings and welding for supporting mangalore pattern roof tiles complete.
M&L Roof tiles, Mangalore pattern, interlocking at side joints, laid dry
.-Ditto- all as per item No-23 here-in-before but except tile complete all as specified and directed.
M&L ridge or hip tiles to suit Mangalore pattern roofing tiles bedded and jointed in CM 1:6 using class 'AA' tiles.
M&L cement filleting in CM 1:3 in roof sectional area n.exc 25 sqm
Removing Completely removing existing water proofing treatment of any descriptions and any type including top layer of plaster / china mosaic wherever occurs over roof and chhajja surfaces and scrubbing the surface with wire brush and cleaning wash down with water to receive new cement plaster / PCC layer and removing the waste material / debris etc , complete all as specified and directed .
M/L for rendering 15 mm thick in cm 1:4 using readi plaster on external surface of brick walls or concrete roof surfaces mixed with water and all as per manufacturer instructions etc, finishing the surface even and smooth without using extra cement etc , complete all as specified and directed . Make:- Ultra Tech / Silico / Renaplast/Kaneria
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- (a) Apply one coat of bituminous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reniforcement weighing not less than 4.00 Kg/Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
M&L for making the grooves 25mm wide and 50mm deep to 'V' section in existing walls/columns over RCC roofs, cleaning out and tacked the polymeric membrane in to the grooves, inserting chajja of PPGI sheet and sealed solidly with a hot mixture of bitumen and clean dry sand in the ratio of 1:1 by weight etc complete all as specified and directed.
Complete removal of existing treatment of external surface of wall including removing fungus /algae dirt, oil, grease and loose particles by wire brush,cleaning, washing and removing dust, . Cracks less than 2 mm, should be cleaned free of dust with a vaccum cleaner and apply Dr. Fixit Primeseal (Efflorescence resistant penetrating primer.) let it dry. Then pour Dr. Fixit Raincoat into these cracks and wait for it to dry Apply the first coat of Dr. Fixit Raincoat without any dilution at the rate of 2 sqm per litre and allow it to dry before taking up the second and third coats, the rate of application being the same, Drying time between coats will be 6 to 8 hrs, A total thickness of 1 to 1.2 mm must be achieved when Dr. Fixit Raincoat is dry and including necessary scaffoldings etc , complete all as specified and directed Note:- Application of primer and paint shall be done by the authorised applicator of the manufacturer of the paint and a certificate to this effect shall be produced by the contractor.
M&L for preparing newly plastered surface of walls and applying two coats of Oil bound distemper over a coat of alkali resistant primer over a coat of wall care putty complete all as specified.
RK AND SONS CREATION
Om Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .