Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC | L1 | Accepted-AOC Found lowest one bidder | |
| 2 | L2₹11.6 L+₹18,800 (1.64%)Rejected-AOC | L2 | Rejected-AOC Quoted high rate as compared to L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical class of contractor contradicts |
Tender Value
₹10 L
Closing Date
7 Feb 2022, 2:00 pmClosed
Executive Engineer
Rural Engineering Wing Leh
Completion of community hall at Tashi Gatsal 4 Choklamsar Block Leh
2022_RDD_5708_4
NIT 123 - UTL REWL OF 2021-22
Open Tender
Civil Works - Others
Item Rate
60 days
Leh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Payable To Executive Engineer
Exempted
2 Mar 2022
27 Jan 2022
9 Feb 2022
27 Jan 2022
7 Feb 2022
27 Jan 2022
Amount
Providing, fixing and applying plaster of paris (POP) false ceiling consisting of frame work made with 50mm sq M.S. tubes of 18 G thickness as main runner at 600 mm c/c both ways, -i suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab including providing and fixing expanded metal of size 5.25mmx1.25mm thickness welded to main runner and applying POP (calcium sulphate semihydrate variety)to the expanded metal of thickness not less than 1 Omm finished smooth to line and level including necessary supports scaffolding etc. as required and also including applying a coat of red oxide zinc chromate primer over the M.S. fiame work and suspenders complete
Wiring for light point for ceiling light LED with 1.5sqm PVC.FR insulated copper conductor single core in surface /recessed medium class PVC conduct suitable size m.s box and earthing the point with 0.75 sqm FR PVC insulated copper conductor single core cable required including LED light panel in round shapped with 10 watt using brand phillips anchor or any equivalent brand .
Wiring for light point 6amp socket with 2.5mm PVC.FR insulated copper conductor single core in surface /recessed medium class PVC conduct suitable size along with modular switch and socket 6ampplate recessed including MS box and all complete job using approved brands like phillps or any equivalent
supplying and drawing circuit wire for light and 6/16 amp socket outlet with 4.0sqm FR PVC insulated copper conductor single core cable in recessed /surface PVC conduct pipe as required
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.A) Single pole 6/10/20 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.B) Double pole 40 Amp
Supply and fixing of miniature circuit breaker of following poles in the existing MCB DB completed with connections testing and commissioning etc, as required.C) Double pole 63 Amp
supply and fixing following way horizontal type 3 pole and neutral sheet MCB distribution board 4254 on surface/recess complete with tinned copper bass bar neutral bass bar 8 way complete job
supply and fixing change over 63amp including placing in position complete job
supply and fixing of 25mm PVC casing along with acessories in surface / recessed including clipping on the walls as required complete job
supply and fixing 12mm core main wire of aluminum including placing in position complete job
supply and fixing of flash light LED outdoor 100 watt with G.I pipe fitting with 2.5mm wire and switch complete job
M/S MUBASHIR HUSSAIN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .