Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
17 Jun 2024, 6:00 pmClosed
CWE NEW DELHI
CWE NEW DELHI-10
REPAIR/MAINT OF TRANSFORMER HT/LT CABLE AND BASIC E/M WORKS AT NDC, AHQ CAMP LODHI ROAD UNDER GE NEW DELHI
2024_MES_644136_1
CWE/ND-32/2023-24
Open Tender
Civil Works - Others
Item Rate
270 days
ARMY AREA OF GE NEW DELHI
REFER TENDER
10 documents required · 10 mandatory
₹500
GE NEW DELHI
₹40,000
Yes
11 Sept 2024
4 Mar 2024
20 Jun 2024
4 Apr 2024
17 Jun 2024
3 Jun 2024
Amount
Dehydration and filtration of the existing transformer/servo voltage stabilizer oil by dehydration plant to achieve di-electric strength of 60 KV at the gap of 4 mm complete all as specified and directed by Engineer-in-charge. Notes:- Dehydration plant shall be brought at site by the contractor and shall also include the following provisions:- a) Testing of transformer /servo voltage stabilizer oil before & after dehydration shall be carried out as directed. b) The Unit of payment under this item shall be per litre of oil meant for all processes to the entire completion of jobs. (c) Contractor will maintain a register of dehydration and filtration of each and every equipment as per format given by Engr-in-charge and submit the same to Engr-in-charge.
Supply and filling mineral grade transformer oil EHV type conforming to IS-335 of 1983 for topping up or replacement in different existing transformers outdoor/indoors type of any capacity located and installed at different places and different height complete all as specified and as directed . Note: - The entire quantity of transformer oil shall be procured in one go. The complete material shall be brought at MES store and then as per requirement oil should be shifted to site. Cost of this aspect deemed to be included in the quoted rate
M&L for disconnecting power supply from HT VCB of capacity up to 630 Amps, taking out trolley unit & complete servicing of the same through decarbonizing servicing & cleaning of the male/female isolating contacts, lubricating moving part, cleaning with CRC removing dust particles from bus bar chamber, spout gear mechanism and moving parts, repair to motor charge spring mechanism, including cleaning of Vacuum Interrupter and all HT bushings , Cleaning of Flashes if any and refixing of cable by fixing the nut bolt, Washer to HT side tightly and refixing the trolley at its original position and testing and putting on load complete all as specified and directed by tightening all nuts and bolts of entire trolley, checking proper operation of trolley all as directed, inserting trolley inside, and testing and putting on load complete all as specified and directed. Note: (i) The work shall be executed through OEM or their authorized Rep. (ii) The spares required to be replaced shall be measured & paid separately as 'Supply only' under relevant item No. 4.00 to 12.00 of BOQ. The cost of replacement shall be deemed to be included in rate quoted for this item.
Supply only set of mechanical castle inter lock assembly with key suitable for HT 11 KV VCB of rating 630 Amps as per existing make complete all as specified and directed.
Supply only closing coil assembly 24/110 volts DC for VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
Supply only tripping coil assembly 24/110 volts DC for HT 11 KV VCB of rating 630 Amps, as per existing make complete all as specified and directed.
Supply only fixed contact block of VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
Supply only moving contact block of VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed..
Supply only Vacuum Interrupter , suitable for HT VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
Supply only Spring Charge motor & gear assembly 220 Volt AC suitable for VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
Supply only plug and socket assembly for VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
Supply only auxiliary switch (6 No + 6 NC) for HT VCB 11 KV 630 Amps capacity as per existing make complete all as specified and directed.
S&F in replacement 1500 watts, 230 volts, AC, single phase rated strip heater with switch and thermostat for space heating complete all as specified and as directed .
Supply and fix in replacement over current & earth fault relay suitable for 11 KV VCB 400/630 Amps indoor control panel complete all as specified & directed.
S&F in replacement frequency meter digital type suitable for HT 11 KV VCB complete all as specified and as directed .
Supply & fix in replacement set of 3 Nos pilot lamp LED type for indicate On/Off Trip, 24 Volts DC complete all as specified and as directed .
M&L for finding the fault with fault locating Machine mounted on Vehicle along with auxiliary power supply required for Installing of equipment connected to FLC Machine along with necessary manpower and T&P for finding out fault in cable HT (11 KV) / LT (1100 Volts) by using Ultra sound technique. Complete all as specified and as directed . Note: 1. Contractor shall bear all the cost incurred in arranging FLC machines along with permission of digging in case of land belonging to other than MES/Defence. 2. If contactor fails to arrange the FLC machine within six hours from getting the information either from GE, Engr-in-Charge or concerned JE verbally or telephonically,Penalty amount of Rs. 1500/- per hour shall be recovered from contactor's dues.
S&F in replacement of dehydrating agents (Silica gel) in transformers of capacity up to 500 KVA transformer outdoor/indoor type complete all as specified and as directed.
Supply and fix in replacement of LT bushing (Brass stud and bolts with porcelain insulator) suitable size to fixed the transformer capacity range 200 to 500 KVA including replacement of gasket, cable glands, etc. to make the transformer leak proof complete all as specified and as directed .
S&F in replacement of LT bushing (Brass stud and bolts with porcelain insulator) suitable size to fixed the transformer capacity range 500 KVA to 1000 KVA including replacement of gasket, cable glands, etc. to make the transformer leak proof complete all as specified and as directed .
S & F in replacement ceramic bushing and Gasket on LT side of transformer of following capacities complete all as specified and as directed:
S & F in replacement ceramic bushing and Gasket on HT side of transformer of following capacities complete all as specified and as directed:
S & F in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete including taking out old U/S all as specified and as directed .
S & F in replacement MCCB 3 Pole, 415 V, adjustable type 160 Amps with breaking capacity 36 KA complete including taking out old U/Sall as specified and as directed .
S & F in replacement MCCB 3 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete including taking out old U/S all as specified and as directed .
S & F in replacement MCCB 3 Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA complete including taking out old U/Sall as specified and as directed .
S & F in replacement MCCB 4 Pole, 415 V, adjustable type 200 Amps with breaking capacity 36 KA complete including taking out old U/S all as specified and as directed .
S & F in replacement MCCB 4 Pole, 415 V, adjustable type 250 Amps with breaking capacity 36 KA complete including taking out old U/Sall as specified and as directed .
S & F in replacement MCCB 4 Pole, 415 V, adjustable type 400 Amps with breaking capacity 36 KA complete including taking out old U/S all as specified and as directed .
S & F in replacement danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed size, for LT, 20 x 15 cm size complete all as specified and directed .
S & F in replacement Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed size, for HT, 25 x 20 cm size complete all as specified and directed .
M&L for maintenance and overhauling of ACB 630 Amps to 1250 Amps capacity including disassembling all operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories, oiling/greasing of moving parts, cleaning of all pole partition hylem sheet, isolating contacts, re assembly, fine setting of mechanism and pole assembly and making ACB perfect operational including well cleaning the complete bus bar chambers, insulator, partition etc. and checking of insulation resistance of ACB main bus bar complete all as specified and directed . Note- (i) The work shall be carried out by OEM or their authorised representative. (ii) The spares required to be replaced shall be measured & paid separately as 'Supply only' under respective item of BOQ. The cost of replacement shall be deemed to be included in rate quoted for this item.
Supply only Fixed Arc Contact- 3 pole
Supply only Moving Arc Contact- 3 pole
Supply only Auxiliary contact 4 No+ 4 NC
Supply only Motor Mechanism for 630 Amps ACB
Supply only Shunt Trip Coil
Supply only Control Fuses HRC type 2 to 10 Amps
M&L for servicing of Voltage Stabilizers capacity above 75 KVA up to 150 KVA including replacement of minor equipment and spares complete all as specified and directed . Note- Rate of minor equipment and spares deemed to be included in the quoted rate for this item.
M&L for cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of sizes120 Sqmm 3 core complete all as specified and directed .
M&L for cable XLPE insulated screened PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of the following sizes laid wall/floor with clip and trunch complete including taking out old U/S cable all as specified and directed .
120 Sqmm 3.5 core
95 Sqmm 3.5 core
70 Sqmm 3.5 core
50 Sqmm 3.5 core
35 Sqmm 3.5 Core
Supply & fix cable jointing kit and testing complete for 11 kv grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete including taking out old U/S all as specified and directed.
Supply & fix cable jointing kit and testing complete for 11 kv grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm complete all as specified and directed.
Supply , fixing & testing heat shrinkable straight through Jointing Kit suitable for LT Cable of size 50 Sqmm 3.5 core complete including taking out old U/S all as specified and directed.
Supply , fixing & testing heat shrinkable straight through Jointing Kit suitable for LT Cable of size 70 Sqmm , 3.5 core, complete including taking out old U/S all as specified and directed.
Supply , fixing & testing heat shrinkable straight through Jointing Kit suitable for LT Cable of size 95 Sqmm , 3.5 core, complete including taking out old U/Sall as specified and directed.
Supply , fixing & testing heat shrinkable straight through Jointing Kit suitable for LT Cable of size 120 Sqmm , 3.5 core, complete including taking out old U/S all as specified and directed.
M & L in replacement for galvanised pipe of dia 100 mm, light grade with all fitting, laid in trenches for passing of cable etc. complete including taking out old U/S all as specified and directed .
M & L for replacement of potential transformer (voltage transformer) 11 KV/ 1100 V, dry type , complete with winding, indoor resin cast & ratio 11 KV/rt3/1100/rt3/class 0.5-3, burden 50 VA-50 VA including connecting and testing complete including taking out old U/Sall as specified and directed .
Supply , installation, testing & commissioning with HT resin cast CT of ranging 15 Amp to 150 Amp/5-5A as per each feeder required class 1.0/5P10, burden 15 VA-15VA including connecting and testing complete all as specified and directed .
M&L for Earthing in replacement with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron strip 25x4 mm by means of bolts, nuts , check nuts and washers of GI strip 25x4 mm protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with & including 40 mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 meters, all as per electrical plate No 3 of SSR 2009 Part-I including testing on complete all as specified and as directed. Note: GI strip & protection pipe up to 7.5 m is included in the quoted rate .
M&L in replacement Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. complete all as specified and as directed .
M&L for Chemical Earthing complete with Copper earth plate 90 mx 60 cm x 5 mm thick electrode buried directly in ground vertically not less than 4 m deep below ground level with top edge of the plate not less than 2.25 m deep below ground level and connected to copper strip size of 32 x 6 mm as earthing lead by means of bolt nut and brazing, check nut and washer all as directed to test point including necessary excavation and earth work (in any type of strata) and providing charcoal duct 250 Kgs, common salt 200 kgs, magnesium sulphate 100kgs and all around the plate 15 cm depth and wide and up to 650mm height in continuous layers, balance pit will be filled with vegetable soil up to ground level including watering pipe GI light grade of 20 mm dia and 50 mm dia pipe light grade for earth strip protection up to 7.5 m, PCC(1:3:6)type C1 chamber , heavy duty funnel with & including 40 mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape all as directed. Note: Cost of Copper strip & protection pipe up to 7.5 m is included in the quoted rate .
Supply only for Discharge rod for discharging of HT side (11 KV) 3 metre long. Complete all as specified and directed .
M&L for replacement of HT (11 KV) insulation mat 16 mm thick complete including taking out old U/S all as specified and directed .
M&L for rectification of fault using eclectically operated Hi pot Machine to check the HT cable so that is stands a capacity of up to at least 11 KV. Complete all as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide in not exceeding 1.5mtr in depth for UG cable etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed by the Engineer-In-Charge.
Returning filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed by the Engineer-In-Charge.
Removing excavated material not exceeding 50mtr and depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by the Engineer-In-Charge.
M&L for sand cushioning (dry sand) to underground cable for cable protection laid in trenches / in existing cable ducts complete all as specified and as directed by the Engineer-In-Charge.
M&L for brick laying with subclass 'B' bricks well burnt, laid dry flat in trenches for protection of cable over cable, complete all as specified and as directed by the Engineer-In-Charge
KISHORE ENTERPRISES
H.B. Traders
J B Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .