Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.8 LAccepted-Finance | 1 | Accepted-Finance Lowest RAte | |
| 2 | 2₹12.1 L+₹31,480 (2.67%)Rejected-Finance | 2 | Rejected-Finance Higher Rate | |
| 3 | Rejected-Technical | - | Rejected-Technical Technical Bid Found Not Ok. |
Tender Value
₹13 L
EMD Value
₹13,000
Closing Date
3 Oct 2023, 1:00 pmClosed
SE EDC Etah
Vidhyut Colony, Aruna Nagar, Railway Road, Etah.
Various Electrical work of electric supply in the area of EDSD IInd (Aliganj), Etah (EDD-Ist, Etah) under additional business plan (339 Cr.) on Semi Turnkey basis.
2023_DVVNL_842803_1
44/2023-24/EDC ETAH
Open Tender
Electrical Works
Turn-key
Distt Etah
As per Tender Documents.
2 documents required · 2 mandatory
₹3,540
DVVNL
₹13,000
17 Oct 2023
23 Sept 2023
3 Oct 2023
23 Sept 2023
3 Oct 2023
23 Sept 2023
Amount
Supply of The Line Material as per Relevent ISS :-
Nut & Bolt with Washer
MS Droper Chanel
MS Angle
Stone Pad
Top Chanel
Holding Clamp for Top Chanel
MS T off Chanel
Danger Board
Protection Board for Power TF
Tripping Coil for VCB
LT Clamp
Base Angle
Erection Work :-
Safe carriage of line material from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
Safe carriage of following 11 KV XLPE Cable from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
(a) 11 KV XLPE Cable 3x120
(b) 11 KV XLPE Cable 3x185
Safe carriage of VCB from store center Etah to pit site in distance range 0 to 60 km including loading & unloading at both ends.
(a) 33 KV VCB
(b) 11 KV VCB
Safe Carriage of 9/8.5 Mtr Long PCC Pole from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side
Safe Carriage of following TF from Electricty store center Etah/nearest 33/11 KV S/S to direect Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side.
(a) 25/63 KVA TF
(b) 100 KVA TF
Safe Carriage of 33/11 KV CT/PT from Electricity store center Etah/nearest 33/11 KV S/S to direct Pit site in distance range 0 to 60 Kms. Including loading and unloading at both side.
Erection of 8.5 mtr long PCC Pole as single support including fixing of HT/LT accessories etc and other work complete as per RESPO norms.
Erection of 9 mtr long PCC Pole as single support including fixing of HT/LT accessories etc and other work complete as per RESPO norms.
Erection of 8.5 mtr long PCC Pole as Double Pole/Section Pole including fixing of HT/LT accessories with TPMO etc and other work complete as per RESPO norms.
Dismantling and removal of existing ACSR Weseal/Dog conductor/GI wire from the various area, stacking and placement their coils and their in the safer place including cost of lobour T&P etc. required for proper completion of work.
Laying sagging stringing, binding, jumpering & fixing of all accessories etc of following conductor on the newly/old erected pole as per RESPO manual and as per direction of supervising engineer. It includes the cost of labour, T & P, carrier etc required for proper completion of work.
(a) ACSR Dog Conductor
(b) ACSR Weseal Conductor
(c) 11 KV XLPE Cable 3x120 sqmm
(d) 11 KV XLPE Cable 3x185 sqmm
Re-sagging of loose Weseal/Dog conductor as per direction of supervising engineer. It includes the cost of labour, T & P carrier etc required for proper completion of work.
Stone Pad
Earthing Complete
11 KV Cable Jointing Kit O/D 3x185
11 KV Cable Jointing Kit I/D 3x185
33 KV Jointing Kit Straight Thourgh
Danger Board with clamp
Protection Board for Power TF
Tripping Coil for VCB
Earthing for VCB
33 KV Lighting Arrestor
33 KV VCB 800 Amp, 750 MVA
33 KV Isolator
33 KV Bus Isolator
Cable LT PVC 1x120 sqmm
11 KV PT for VCB
33 KV CT Incoming
33 KV CT Outgoing 200/100/1Amp
11 KV VCB Outgoing CTR 200/100/5A/350 MVA
33 KV VCB 800 Amp, 750 MVA
Making of 33 KV VCB double TF control panel NCT 200/100 1Amp with structure as per RESPO norms.
Erection and grouting of stays as per RESPO Norms and as per direction of supervising engineer. Grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost.
Mounting of following TF on Double Pole including making of the connection etc. complete.
(a) 25/63 KVA TF
(b) 100 KVA TF
Any other material/consumable required to complete the work shall be arrange by the contractor at his own cost.
Carriage of line material (Scrap) from pit site to JE store/store center Etah in distance range 0 to 60 km. including loading & unloading and proper stacking.
(a) ACSR Dog Conductor
(b) ACSR Weseal Conductor/GI Wire
(c) 11 KV XLPE Cable 3x185
(d) 10 KVA TF
YASH URJAA VARDHAN PVT. LTD.
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .