Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.5 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.9 L+₹1.4 L (7.69%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹20.2 L+₹2.7 L (15.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹22.6 L
EMD Value
₹45,200
Closing Date
30 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
SPECIAL REPAIR/REPLACEMENT OF BER SUMMER AND COOLING APPLIANCES AT CQA(M), DGQA, DS CELL AND PROVISION OF GEYSER FOR BATHROOM AND OR MESS, 108 A DSC PLATOON UNDER GE (I) KANPUR
2024_MES_681672_1
GE(I)/KAN/T-74 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (I) KANPUR
₹45,200
Yes
20 Jan 2025
28 Oct 2024
7 Dec 2024
28 Oct 2024
30 Nov 2024
11 Nov 2024
Amount
Disconnecting, dismantling and taking out indoor and outdoor unit of split type AC with cooling tubing and other accessories with carefully and deposited to MES store yard with outer/inner unit, copper tubing, drain pipe and remote complete all as specified and directed.
Supply, installation, testing & commissioning of split type air conditioner of capactiy 1.5 TR, wall mounted type, working on single phase, 240 volts, 50 Hz AC supply with cordless remote control unit, built-in air ionizer and plasma filter for better air quality with inverter technology having minimum 5 Star rating and EER 3.2 with copper condenser coil including fixing of indoor and outdoor unit, and necessary copper pipe connections including cutting, bending, brazing, insulation on pipe etc, PVC drain pipe, electric connection between indoor and outdoor unit with suitable size PVC insulated, multi-stranded copper cable complete all as specified and directed. [Note: (i)All connected pipes shall be concealed with casing and capping and the PVC drain pipe shall be taken to ground level. The rate quoted shall include for these provisions] (ii) The said AC will be installed Existing/New Location as directed by Engr-in-charge. (iii) Contractor shall submit guarantee/warantee certificate from manufacturer and shall be responsible for any default till guarantee/warantee period to any default of installation.
Disconnecting, dismantling and taking out window type AC with accessories carefully and deposited to MES store yard complete with remote complete all as specified and directed.
Supply and fix window type room air conditioner electric driven of capacity 1.5 TR single phase 230 Volt + 10%, 50 Hz, AC supply with cordless remote control unit with copper condenser air cooled with BEE 5 star rating including required cutting of holes in walls / window / aluminium partition etc of any thickness for installation of AC etc. connection and making good the disturbed surface to match with the existing complete all as specified and directed. Note :- (i) Cutting holes in walls / window / aluminium partition etc of any thickness for installation of AC etc, connection and making good the disturbed surface to match with the existing surface after work shall be done. The unit rate quoted by contractor shall deemed to be inclusive of this aspect. (ii) Provision of angle iron stand / wall mounted platform etc for fixing / supporting the AC unit is inclusive in above rate. (iii) Contractor shall submit guarantee / warranty certificate from manufacturer and shall be responsible for any defect till guarantee/warantee period.
Disconnecting, dismantling and taking out carefully of Water cooler/refrigerator any type/ any capactiy with accessories and deposited to MES store yard complete with remote complete all as specified and directed.
Supply and fix single door electric driven (single phase) refrigrator of capacity 165 Ltr complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage of 180 litres and nominal cooling capacity 150 litres per hour, complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage capacity of 120 litres and nominal cooling capacity 60 litres per hour, complete all as specified and directed.
S&F sub main wiring for circuit of size 4 sqmm 2 core alongwith earth wire of 2.5 sqmm single core of FRLS PVC insulated unsheathed cable (FR), 1100 volts grade with multistranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including PVC non metalic rigid conduit/casing of suitable size and conduit/casing accessories run on surface of wall/ceiling etc and connecting terminal ends of suitable size complete all as specified and directed.
M&L for single pole and neutral sheet metal encloser with a two pin with earth plug and socket 20 amps 240 volts with one single pole MCB of 20 Amps complete all as specified and directed.
Disconnecting electrically, existing ceiling/exhasut fan any type and capacity and taking down with due care, dismantling blades and deposting to MES store yard with all accessories complete all as specified and directed. Note: T&P will be provided by the contractor for reaching any height of the bldg/ Hanger.
Supply and fixing ceiling fans (existing or new location directed by EIC) with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor wih remote (BLDC) complete all as specified and directed. Note : 1. Additional down rod if required will be measured and paid separately. 2. T&P will be provided by the contractor for reaching any height of the bldg/ warehouse/ Hanger.
All as per item No 12 above but for ceiling fan 1400mm sweep & min air delivery 245 CFM complete all as specified and directed.
Supply and fixing of Exhaust Fan heavy duty 230 V, AC single phase of size 450 mm sweep 1400 RPM with louver shutter with fixing arrangement including grouting of nuts, bolts electric connection and writing MES No. with black synthetic enamel paint/engraving tool etc in wall complete all as specified and directed.
S&F in replacement of rigid steel conduit welded cut to pieces of size 20mm dia treated both ends for hanging ceiling fan 1200/1400mm size including necessary hook, calmps both sides with hook, nuts bolts, rubber real etc complete all as specified and directed.
Supply and laying 40mm dia galvanized, “Medium class” pipe, on the wall roof for hanging of ceiling fans and making good wall surface complete all as specified and directed.
Disconnecting, dismantling desert cooler of any type/capacity with accessories and taking out carefully and deposited to MES store yard complete all as specified and directed.
Supply, installation, testing and commissioning of desert cooler of fiber body fully exhaust fan 450 mm sweep, 1400 rpm motor of copper winding and suitable capacity submersible pump cabinet size not less than 69cmx117cmx47cm water tank of capacity 72 Liters ,1000 watts speed control electronic regulator, suitable size connection cable 3 core with copper conductor with moulded plug top, fan blade and all fixing accessories complete all as specified and directed Note:- All electrical equipments shall be of ISI Marks.
M&L for fixing of fan hook on the girder/ GI tube at existing or new location inside the hanger or buiding ,above or below of false ceiling at any hight of CQA (M) controllerate complete all as specified and directed.
M&L for concealed point wiring of PVC insulated and unsheather cable 1.5 sqmm (nominal area) multistranded copper conductor 1100 v FRLSH grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling with all accessories including 1.5 sqmm PVC insulated unsheathed multistranded copper conductor to common earth and connected to earth for One light/fan point controlled by one switch complete all as specified and directed. Note : 1. The cutting chases shall be finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor shall deemed to included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC pipe fixed on wall etc complete all as specified and directed.
Supply & fix in replacement cable PVC insulated flexible copper conductor cable of size 0.5 Sqmm twin core cut to pieces all as required for connection with proper thimbles, drawn in existing GI/PVC pipe fixed on wall etc complete all as specified and directed.
S&F in replacement of down rod for ceiling fans made out of 15 mm dia MS pipe, medium grade duly threaded/pin of size 45-75 Cm long as per site requirement complete all as specified and directed.
All as per item No 24 above but of size 1 Mtrs long complete all as specified and directed.
All as per item No 24 above but of size 1.5 Mtrs long complete all as specified and directed.
All as per item No 24 above but of size 2 Mtrs long complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated with all accessoriessuch as safety valve, thermostate, of NRV, connection piece etc complete all as specified and directed.
M&L for concealed point wiring of PVC insulated and unsheather cable 4 sqmm (nominal area) multistranded copper conductor 1100 v FRLSH grade single core including PVC conduit medium grade of appropriate size (not less than 25 mm dia) ISI marked concealed in wall and surface on ceiling with all accessories including 4 sqmm PVC insulated unsheathed multistranded copper conductor for common& 2.5 sqmm for earth connection dully for geyser complete all as specified and directed :- Note) : 1. The cutting chases shall b finished with cement mortar (1:4) and surface shall be matched with existing surface by using putty, POP etc and applying finishing coat of existing treatment without any extra cost. 2. Rate quoted by the contractor shall be deemed to included metal flush box of suitable size as required at site and 3 mm thick laminated sheet suitable for mounting of switch and socket etc .
M/S G S Gupta and Sons (BID ID -3170871)
AARADHIRAJ ASSOCIATES (BID ID -3177577)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .