Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹19.1 L+₹1.3 L (7.45%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹23.3 L+₹5.5 L (31.2%)Rejected-Finance 144 VIKAS BAZAR MATHURA UP 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹24.7 L+₹6.9 L (39.1%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹25.5 L+₹7.7 L (43.5%)Rejected-Finance 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Jun 2023, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR MAINTENANCE OF INTERNAL ELECTRIFICATION AND OTHER E/M RELATED MAINT SERVICES AT OTM ACCN JCO/ORs MD ACCN CENTRAL INSTITUTES AND MH IN THE AOR OF GE (EAST) MATHURA
2023_MES_599202_1
8200-1359/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE East Mathura
₹80,000
12 Jul 2023
29 May 2023
22 Jun 2023
29 May 2023
20 Jun 2023
13 Jun 2023
29 May 2023 - 20 Jun 2023
Amount
Taking down carefully copper/aluminum copper point wiring (light, fan, socket or power, bell etc.) complete including fixtures & fittings such as switch, socket, regulator, pendant etc and removing the material from site and making good the disturbed surfaces of walls, ceiling etc complete all as directed.
Taking down carefully old unserviceable submain wiring of any type complete all as specified and as directed.
Taking down old unserviceable existing SP/SPN/TPN DB/ enclousers any size and type/any descriptions MCB and making good disturbed surface of walls to match the surrounding surface complete all as specified and as directed.
M & L for point wiring with 1.5 Sqmm (nominal area) PVC single core PVC unsheathed (FRLS) copper conductor cable, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less than 20mm dia) and its all accessories complete concealed in wall including cutting & chases and making good all to the disturbed surfaces to match the existing surface, land providing modular flush metal boxes including base plate and cover plate for mounting modular switches, sockets, regulators etc including earth wire of PVC single core sheathed (FRLS) copper conductor cable of 1.5 Sqmm size in green colour complete all as specified in SSR Part-I & II & directed by the Engineer-in-Charge for the followings:-
One light/fan point controlled by one way modular switch 5 amp complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way modular switch 5 amp on same board complete all as specified and as directed.
One 3 pin 5 Amps socket point controlled by one way modular switch on independent board complete all as specified and as directed.
One bell point controlled by one push button on independent board complete all as specified and as directed.
One light point controlled by 2 way modular switch complete all as specified and as directed.
All as per item No. 4.00 here-in-above but for 3/5 pin 16 Amps socket outlet independent with 4 Sqmm PVC unsheathed (FRLS) copper conductor cable complete all as specified and as directed .
S&F Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F bell push single pole one-way, 6 Amps 1 Module with indicator complete all as specified and as directed.
S&F Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F Modular fan Regulator electronic step type 1 Module complete all as specified and as directed.
S&F modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
S&F Modular switch single pole two-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair switch piano type, SP, one way, flush type 5 Amps complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 5 pin 5 Amp complete all as specified and as directed.
S&F in repair socket out let 2-in-1 flush type 3 pin 5 & 15 Amp complete all as specified and as directed.
S&F in repair switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F in repair bell push siwtch piano flush type, SP, one way, 5 Amps complete all as specified and as directed.
S&F in repair ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified and as directed.
S&F in repair lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F in repair mini MCB enclosure including DP 16 Amp 'C' curve type complete all as specified and as directed
S&F in repair Bell Ding dong type, 230 Volts including connections complete all as specified and as directed.
S&F in repair step type electronic fan Regulator piano flush type, on existing phenolic laminated sheet etc complete all as specified and as directed.
S&F Sub main wiring with two single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranderd copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 20 mm dia and all its accesories concealed in wall/roof including cutting & chases and making good the disturbed surface, including PVC insulated 4 sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one RM.
S&F of Sub main wiring with two run of single core 6 Sqmm cable PVC insulated unsheathed (FRLS) cable with stranderd coper conductor, 1100 votls grade drawn through and including PVC conduit 25 mm dia and its all accessories concealed in wall/roof including cutting & chases and making good the disturbed surface including PVC insulated 6sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 6 Sqmm cable, one run of 6 Sqmm earth wire & 25mm PVC Conduit shall be measured as one RM.
S&F Sub main wiring with two run of single core 10 Sqmm cable PVC insulated unsheathed (FRLS) cable with strandard copper conductor, 1100 votls grade drawn through and including concealed PVC conduit 25 mm dia including all its acessories concealed in wall/roof including necessary cutting/chase and making good distured surface including 10 Sqmm PVC insulated unsheathed stranded (FRLS) cable for earth wire complete all as specified and as directed. Note : Two runs of 10 Sqmm cable, one run of 10 Sqmm earth wire & 25mm PVC Conduit shall be measured as one unit length.
S&F submain wiring with two runs of single core 6 sqmm PVC insulated unsheathed (FRLS) cable with standard copper conductor 1100 volt grade drawn through existing PVC conduit including 6 Sqmm PVC insulated unsheated strandard (FRLS) copper conductor cable as earth complete all as specified and as directed. Note : Two runs of 6 Sqmm single core cabe, one run of 6 Sqmm earth wire shall be measured as one RM.
S&F submain wiring with two runs of single core 10 sqmm PVC insulated unsheathed (FRLS) cable with standard copper conductor 1100 volt grade drawn through existing PVC conduit including 10 Sqmm PVC insulated unsheated strandard (FRLS) copper conductor cable as earth complete all as specified and as directed. Note : Two runs of 10 Sqmm single core cabe, one run of 10 Sqmm earth wire shall be measured as one RM.
S&F Sub main wiring with two single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with multistandard copper conductor, 1100 votls grade drawn through rigid non metallic PVC conduit, (not less than 20mm dia medium grade) including its all accessories complete on wall/roof(making good all to disturb surface as per existing) with and including PVC insulated 4 sqmm unsheathed stranded (FRLS) copper conductor cable for earth wire complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 4 Sqmm earth wire & 20mm PVC Conduit shall be measured as one RM.
S&F in repair indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with 1x 20 watt LED Tube including extrusion aluminium housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, neutral white colour complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F indoor decorative ultra slim surface/Wall mounted LED batten tube light fitting with 1x 20 watt LED Tube including polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K, >100 Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair indoor decorative ultra slim surface /Wall mounted T5 LED batten tube light fitting 1X9 watt LED Tube fitting (size within 600x25x40 mm) suitable for mirror light with polycarbonate channel housing & integrated electronic driver,energy efficient, 140V-270 volts,co- related colour temperature (CCT) of 6500K,>100Lm/Watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair surface mounted, LED Bulk Head fitting of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed.
S&F in replacement LED 9W suitable for B-22/E27 type holder, warm white/cool white/natural white complete all as specified and as directed.
S&F in replacement LED 9W suitable for E-14 type holder, warm white/cool white/natural white complete all as specified and as directed.
S&F in replacement 30W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, top opening and maintainable with heat resistance toughened glass, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 proction with luminaire efficiecy of greater than 80Lumen/Watt, Colour rendering (CRI) of ≥ 70 and co- related colour temperature (CCT) of 5700K (±500K) . The luminaire should have 10 KV surg protection, PF ≥ 0.9 and total harmonic distortion of THD ≤ 10%, voltage range of 140-280V including all connections complete all as specified and as directed.
S&F in repair recess type, 35/36 watt LED panel light (600x600 mm) complete with fittings integrated electronic driver,energy efficient, 230 volts,co- related colour temperature (CCT) of 6500K, natural white complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair LED decorative bed side light fitting 3 watt complete with all accessories, on/off inbuilt switch and including connection complete all as specified and directed.
S&F in replacement indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete all as specified and as directed.
S&F in replacement Post top lantern LED type 30 Watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 12 watt, integrated electronic driver, co- related colour temperature (CCT) of 6500K, warm white/ cool white/natural white complete all as specified and as directed.
S&F in repair LED Round/square recess mounted slim downlighter 18 watt, integrated electronic driver, co- related colour temperature (CCT) of 6000K, warm white/ cool white/natural white complete all as specified and as directed.
S&F in repair building security light bracket made out of 40mm dia medium grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including applying two coats of aluminium paint over a coating of red oxide primer complete all as specified and as directed.
S&F in replacement MCB distribution board, SPN 12 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in replacement MCB distribution board, SPN 8 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in replacement MCB distribution board, SPN 4 Way, Double door, sheet steel, phosphatised, powder painted with bus-bar 200Amp, neutral link, earth bar and din rail , cable ties for cable management, 240 V, complete all as specified and as directed.
S&F in replacement MCB SPN 63 Amps, 'C' series , breaking capacity10KA, 240V complete all as specified and as directed.
S&F in repair MCB SPN 40 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair MCB SPN 6-32 Amps, 'C' series , breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair MCB SP 6 - 32 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in replacement SP enclosure with a two pin and earth plug and socket complete with one single pole MCB 25 Amp complete all as specified and as directed.
S&F in replacement metal clad SPN plug to 20 Amp for fixing on AC box complete all as specified and as directed.
S&F Modular MCB DP 16 Amps, 'C' series, breaking capacity 10KA, 240V complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 1/2 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 3/4 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and as directed.
S&F in repair Plastic Surface mounting box 6/8 module gang box for mounting switches, sockets, fan regulator etc complete all as specified and directed.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 3 way to 6 way including removing & re-fixing of existing switch / socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc required to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F in repair 3 mm thick laminated mica sheet top cover suitable for switch board 8 way to 12 way including removing & re-fixing of existing switch/socket and connection complete all as specified and as directed. Note :- Switch/socket/regulator etc required to be replaced shall be measured & Paid separately under relevent item of BOQ.
S&F in repair LED Bollard light fitting IP-65 rated flare fitted with low glare diffuser 10 watt with PC diffuser, made up of MS pipe and integrated driver with uniform light distribution with required PCC foundation complete all as specified and directed.
S&F in repair Modular metal flush box 1/2 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 3 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 4 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 6 Module complete all as specified and as directed.
S&F in repair Modular metal flush box 8 Module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 1/2 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 3 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 4 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 6 module complete all as specified and as directed.
S&F in repair modular white cover plate with frame, 8 module complete all as specified and as directed.
M&L for point wiring with 1.5 Sqmm (nominal area) PVC insulated, unsheathed, (FRLS) 1100 Volts grade copper conductor cable single core, drawn through and including PVC Casing and Caping and its all accessories of suitable size on wall/roof surfaces ( making good all to the disturbed surfaces as per existing) including one run of 1.5 Sqmm PVC insulated copper conductor cable green in colour for continuous earthing having provision for gang box for fixing switches, sockets, fan regulators etc complete all as specified and as directed for the following:-
One light point/fan point/bell point controlled by one switch.
One 3 pin 5 Amps socket point controlled by one way switch on same board.
One 3 pin 5 Amps socket point controlled by one switch on independent board.
All as per item No. 69.00 here-in-before but with 4.0 Sqmm for 3 pin 15 Amps socket point controlled by one switch on independent board and 4.0 Sqmm copper conductor green in colour as earth continuity conductor complete all as specified and as directed.
S&F switch piano flush type 5 Amps, SP, one way complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 5 pin 5 Amp complete all as specified and as directed.
S&F socket out let flush type 2-in-1, 3 pin 5/15 Amp complete all as specified and as directed
S&F switch piano flush type 15 Amp, SP, 240 volt, one way complete all as specified and as directed.
S&F fan Regulator piano flush type, electronic step type 1 Module complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 6 Amps 1 Module complete all as specified and as directed.
S&F in repair Modular switch single pole one-way, 16 Amps 1 Module complete all as specified and as directed.
S&F in repair Modular fan Regulator electronic step type 1 Module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 5 Pins, 6 Amps combined 2 module complete all as specified and as directed.
S&F in repair modular socket 2-in-1, 3 and 5 Pins, 6/16 Amps combined 2 module complete all as specified and as directed.
S&F SP enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed.
S&F SP enclosure with a two pin and earth plug and socket complete with one single pole MCB 16 Amp complete all as specified and as directed.
S&F in repair indoor wall mounted fitting, brushed nickel finish fixture with opal glass diffuser, with LED retrofit bulb of capacity 09 watts complete all as specified and as directed.
S&F in repair of 70W LED highbay light fitting with wide beam optics & driver, PDC housing, built-in Short-Circuit Protection, Over voltage Protection and Surge Protection, IP-65 protection, suitable for ceiling mount (surface/suspended) including all connections and fixtures complete all as specified and as directed.
Supply, installation, testing and commissioning of outdoor double door LT feeder pillar box, cubical type suitable for 3 phase 4 wire, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 200 Amp - 04 Nos (three phase and one neutral) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following:- (a) MCCB 200 Amp, 4 Pole, 16KA (Ics=100% Icu)- 01 No(IC) (b) Digital Amp meter (0-250) - 01 Each (c) Digital Volt meter (0-250) - 01 Each (d) RYB Indicator - 01 Set Note : The drawing of chamber shall be got approved from GE before placing order for procurement.
Supply, installation, testing and commissioning of outdoor double door LT feeder pillar box, cubical type suitable for 3 phase 4 wire, 50Hz and CPRI approved factory fabricated, powder coated (thickness not less than 100 micron) outer shall be made out of 3.15 mm thick CRCA sheet and MS angle section 50x50x6mm and inner sheet shall be made out of 2.00mm thick CRCA sheet duly compartmentalized having thimble and cable entry boxes with cable glands. Panel should covered from all sides with front and back lockable door and hinges complete with aluminum bus bar of 200 Amp - 04 Nos (three phase and one neutral) mounted/fixed on suitable size angle iron frame/stand embedded in cement concrete type B-1 1:2:4 (using 20mm graded stone aggrigates) including painting steel surface with two coats of synthetic enameled paint over a coat of red oxide primer and general construction confirming to IS/IEC-61439-1:2011, 61439-2:2011 consisting of the following:- (a) MCCB 160 Amp, 4 Pole, 16KA (Ics=100% Icu) - 01 No(Incoming) (b) Digital Amp meter (0-250) - 01 Each (c) Digital Volt meter (0-250) - 01 Each (d) RYB Indicator - 01 Set Note : The drawing of chamber shall be got approved from GE before placing order for procurement.
Taking down carefully service connection of any type complete all as and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables etc and getting out complete all as specified and as directed.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Returning, filling in including spreading, levelling,watering and well ramming excavated soil in layers not exceeding 25 cm thick each after cables have been laid and tested complete all as specified and as directed.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches/duct/fixing on walls/poles or passing through HDPE double wall corrugated pipe (outer dia should not be less then 40 mm) including connecting with suitable lugs, glands, nuts and bolts in existing Panel from pole/Main Panel Box and testing complete all as specified and as directed of following sizes :- Note:- (i) Quoted rate shall deemed be inclusive of cost of HDPE pipe. (ii) Excavation and Earth work shall be measured and paid separately under appropriate item(s) of this Schedule.
10 sqmm 2 core.
16 sqmm 2 core.
16 sqmm 4 core.
25 sqmm 4 core.
S&F in replacement powder coated CRCA steel sheet MCB distrbution board, IP-43 IK-09 protection, double door recess mounted, triple pole and neutral 4 way with 100 Amps rated copper bus bar, type complete all as specified and as directed.
S&F in replacement MCB TPN 40 to 100 Amps, 'C' series , breaking capacity 10KA, 415V complete all as specified and as directed.
S&F TP&N Vertical Loadline distribution board, 4 Way, Double door, sheet steel, phosphatised, powder coated with bus-bar 200Amp, neutral link, earth bar and din rail ,blanking Plates, cable ties for cable management, 440 V, 4 way complete all as specified including fitting suitable MCBs with connections complete all as specified and as directed. Note : MCB /MCCB, DBs shall be of same make and measured and paid seperately under respective items of Sch A. DB shall be fixed in flush pattern by cutting the wall and making good disturbed surface as pe directed & rate shall be included in the items.
S&F in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 250 Amp, with breaking capacity 36kA Complete all as spccified and as directed.
S&F in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 160 Amp, with breaking capacity 25kA Complete all as spccified and as directed.
S&F in replacement MCCB 4 pole 415 Volts thermal magnetic based adjustable type 125 Amp, with breaking capacity 16kA Complete all as spccified and as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion and all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete all as specified and as directed.
Material and labour for Earthing complete with GI earth plate 600mm x 600mm x 6 mm thick electrode buried directly in ground (earth pit not less then 2.25 metres deep below ground level ) with top edge of the plate not less then 1.5 metres below normal ground level connected to GI wire 4.0 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of MES schedule Part-I and incl 15 mm bore light grade GI protection pipe (upto 7.5 metres beyond outer edge of earth pit) PCC M-10 grade (Nominal Mix) using 40mm graded stone aggregate in pit with 40mm thick RCC cover in reinforced cement concrete M-15 grade (Nominal Mix) using 20mm graded stone aggregate, reinforced with 8mm dia bar both way @ 150mm c/c, watering arrangement with funnel and wire mesh and 20 mm bore light grade GI watering pipe, common salt and chaarcoal filling, necessary excavation and earth work complete all as specified and as directed.
M/s RCC
M/s DEVI DAYAL CONSTRUCTION CO
M/S S S CONSTRUCTION
M/S A.K. ENGINEERS
M/S United Builders
Karman Infra Projects
M/s R L PAREEK
R N AGRAWAL
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .