Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.5 LAccepted-Finance 2ND FLOOR SHOP NO 303 MARUTI PLAZA RONCHI BANGAR TOWNSHIP MATHURA | MATHURA | UTTAR PRADESH | 281001 | 1 | Accepted-Finance Committee Approved being L-1 | |
| 2 | 2₹4.9 L+₹1.4 L (41.8%)Rejected-Finance 432 AJAY PAUL GWALIOR ROAD MISSION COMPOUND JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | 2 | Rejected-Finance Committee rejects being L-2 | |
| 3 | 3₹4.9 L+₹1.5 L (42.3%)Rejected-Finance 785 SNEH MARRIAGE HALL KE SAMNE BASHARATPUR SHAHPUR GORAKHPUR | 3 | Rejected-Finance Committee rejects being L-3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Qualified as per zone technical Committee | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Qualified as per zone technical Committee |
Tender Value
₹4.9 L
EMD Value
₹10,000
Closing Date
24 Sept 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Superintending Engineer ETC Office 220 KV Sub Station Banda
WORK OF ERECTION OF 01 NO 132 KV BAY AT 132 KV SUB STATION PAILANI, BANDA FOR 70 MW AVAADA INDSOLAR UNDER ETD BANDA.
2022_UPTCL_725290_1
T-08/ETC(B)/2022-23
Open Tender
Electrical Works
Item Rate
120 days
Banda
As per enclosed Tender Document
2 documents required · 2 mandatory
₹1,180
As per NIT
₹10,000
12 Jan 2023
1 Sept 2022
26 Sept 2022
1 Sept 2022
24 Sept 2022
1 Sept 2022
Amount
(1) Erection of Main and auxiliary structure consisting of columns, beams, peaks, masts etc. and auxiliary structure required for installation of isolators, C.Ts. P.Ts. L.As. and all other equipments. All material to be erected shall be supplied by UPPTCL free of cost but all men, material and T&P required for satisfactorily completion of work shall be arranged by the contractor at his own cost.
(a) 132KV side (Main & Auxilary structure)
(2) Erection of following equipments as per Instruction manual of various equipments and technical specification including shifting of material/equipments from store to erection site including all other associated work to complete the job satisfactorily.
(5) 145 KV Isolator with 1 ES (Motorised)
(6) 145 KV Isolator with 2 ES (Motorised)
(7) 145 KV Tendom Isolator (Motorised)
(9) CT/PT Junction Box
(10) 132 KV Simplex Type Relay and control Panel
(11) Meter Cubical with 02 No. ABT Meter
(3) Cutting,strengthening,bending,laying 800 mm.below in side ground and above ground of following size of MS Flat for earthing of main and auxiliary structure, equipment structure and its material etc. Encluding welding with main earth mat and with object to be earthed /excavation of trenches its back filling.
(4) Interconnection of following equipments and bus bar including cutting, bending of conductor and jumpering, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn.
(A) 132 KV Side. 1 x P (1 Main + 1Z)
(5) Preparation of interconnection diagram of various connection between CB, CT, PT & CRP etc.
(6) Laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and JB etc. In switchyard as per cable schedule.
(A) 2C x 2.5 Sq mm. unarmoured.
(B) 4C x 2.5 Sq mm. unarmoured.
(C) 6C x 2.5 Sq mm. unarmoured.
(7) Fabrication of Delta Structure required for LA with the help of 40 mm. M.S. Round bar.
(8) Termination of following sizes of cable as laid above as per cable schedule including making necessary holes in glands plates or box where ever required supply and fixing of cable glands of appropriate size, supply & providing ferrules & Nos for each core of cable and its termination with crimping type lugs of dowell/tension make and all other assiciated work to complete the job satisfactry.
(A) 2C x 2.5 Sq mm. unarmoured.
(B) 4C x 2.5 Sq mm. unarmoured.
(C) 6C x 2.5 Sq mm. unarmoured.
(9) Stringing of 132KV Bus bar with different type of conductor & span mentioned bleow including fitting of tension clamps, hoisting of insulators and other associated works to complete the job as per tension chart.
(A) Extension of 132 KV Main bus (1Mx12)
(B) Extension of 132 KV Transfer Bus (1Px12)
(C) Jumpering of existing Bus to new constructed bus and its various jumpering work.
(10) Laying of 40mm dia M.S. round bar 800mm below ground level including cutting ,straightening ,welding ,painting excavation of trench, partially on rocky land and fishered soil ,its back filling and all other associated works to complete the work satisfactorily as per drawing and technical specification ,excluding the cost of M.S. bar.
(11) Cutting, Fabrication and fixing of angle iron by welding including cost of electrodes, labour, T&P. Details of every job includes-
(a) Taking out scrap angle heap of scrap, cutting the cleats of 50x50x6mm angle iron & shifting back the scrap (scrap angle iron will be provided by department). (b) Fixing of cleats of angle iron by welding including cost of electrodes, labor, T&P.
Fabrication of 3M long Electrode with 40MM dia M.S. rod having 150mm long conical shape and then its piercing vertically in side the ground with top 500mm.below ground level and its welding with earthmat, excluding the cost of M.S. bar.
Rates qouted by the bidders shall be without taxes. Taxes applicable if any to paid extra
M/S V.K.T. SYSTEMS
AMAN CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .