Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 CrAccepted-AOC ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | ₹16.1 Cr | L1 | Accepted-AOC APPRVED ABOVE RATES FROM DULB |
| 2 | L2Rejected-AOC VPO BARI TEHSIL GANAUR SONEPAT 131101 | SONEPAT | SONIPAT | HARYANA | 131101 | - | L2 | Rejected-AOC QUOTED RATE HIGHER THEN THE L1. SO REJECTED |
Tender Value
₹11.7 Cr
EMD Value
₹23.4 L
Closing Date
15 Jul 2019, 5:00 pmClosed
SECRETARY MUNICIPAL COMMITTEE BAWAL
MUNICIPAL COMMITTEE BAWAL
Construction work of Parking and Shopping Complex in MC Bawal
2019_HRY_85055_1
MCB/2019/SHOPPING COMPLEX
Open Tender
Civil Works
365 days
MUNICIPAL COMMITTEE BAWAL
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
Secretary Municipal Committee Bawal
₹23.4 L
Yes
24 Sept 2020
6 Jul 2019
16 Jul 2019
6 Jul 2019
15 Jul 2019
6 Jul 2019
6 Jul 2019 - 15 Jul 2019
Amount
Civil Works Providing & fixing factory manufactured uPvc openable, fixed & sliding doorrs & windows with standred sections (including the cost of labour for fixing the same in position)as per the directions of Engineer in charge Fixed glass Door (N.S.)
Glass door's
ELEVATOR for Shopping Complex (N.S.) Enclosed Quotation
Providing and fixing the fabricclamping and tensioning as per direction of Engineer in charge (N.S.)
Public Health Rain Water Harvesting System Providing & fixing PVC pipe (4 kg/cm2) duly slotted IS-4985:1988 including cost of adhesive, carriage, loading, unloading etc. complete in all respect to the satisfaction engineer incharge. Size: 160 mm od (N.S.)
Public Health Works Providing and fixing in position P.V.C soil waste vent or antisyphonage pipes to I.S.I specification of manufacture or of any other reputed firm including cutting and wastage etc. and cutting holes in walls, roofs or floor etc. and making good to its original condition but excluding cost of lead jointing 100mm internal diamter(N.S.)
75mm internal diameter
Providing and fixing in position P.V.C special for soil, waste, vent or anti-syphonage pipes to I.S.I marked including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead jointing (a) 100mm i/d pipe (xiii) Bend with door (N.S.)
(xiv) Bend Plain
(xvi) Cowls
(xxii) Collars
(xxiv) c) WC connection 300mm long
(b) 75mm (xiii) Bend with door
(xiv) Bend Plain
(xxii) Collars
(xvii) Cowls
Cost for Supply of Material Provision for supply of material of reputed make complete in all respects. (N.S.) G.I. Pipes 15mm I/d
G.I. Union 15mm I/d
Peet Valve 15 mm I/d
G.I. Sleave Pieces 15 mm I/d
Providing & fixing water cooler ISI mark 100 liter capacity
Providing & fixing R.O system I.S.I marks
Electrical Work Fire Fighting system Supplying, installation, Testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect are required: a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/Sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 50 m head conforming to IS 1520. b) Suitable HP, SQ cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts 3 phase 50 Hz. AC with IP 55 protection for endosure, horizontal foot mounted type with class-'F' insulation, conforming to IS-325. c) M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required d) Suitable cement concrete foundation duly plastered, with anti-vibration pads.
Supplying, installation, Testing and Commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required: a) Horizontal type, centrifugal, pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 50 M head conforming to IS 1520. b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 volts electric starting equipment, Diesel Tank, exhaust pipe extended upto 1 m. outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm. thick aluminium sheet cladding, residential silencer, instruments and protection as per specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. c) M.S. Fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered, with anti vibration pads.
Supply, installation, Testing and Commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following: complete in all respect as required: a) Horizontal type, centrifugal, pump of cast iron, body & bronze impeller with stainless steel shaft, mechanical seal and flow of 180 LMP at 60 m. head conforming to IS:1520 b) Suitable HP, SQ cage induction motor TEFC type suitable for operation on 115 volts, 3 phase 50 HZ. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation conforming to IS: 325. c) M.S fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered with antiviabration pads.
Supplying, installation, testing and commissioning of electric driven Fire Pump for Sprinkler suitable for automatic operation and consisting of following: complete in all respect as requierd: a) Horizontal type, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 1616 lpm at 50 M head conforming to IS 1520. b) Suitable HP, SQ cage indication motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts 3 phase 50 Hz. AC with IP 55 protection for endosure, horizontal foot mounted type with class-'F' insulation, conforming to IS-325. c) M.S fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. d) Suitable cement concrete foundation duly plastered, with anti-vibration pads.
Supplying, installation, Testing & Commissioning of vertical type submersible dewatering pump set with Cl impeller cutter type integrated with the shaft of 1 HP, 1450 RMP single phase asynchronous motor as a common unit having the head 11.5 mtr., discharge 8.0m3/hr portable to be mounted in the existing trench including connection of the GI pipe, bends, NRV with discharge line of the pump, followed by electrical connection with cable etc. complete as required.
Supplying of XLPC insulated, PVC sheathed aluminium conductor 1.1 KV grade armoured U.G. cable of following sizes etc. as required a) 3.5 x 95 sq.mm
b) 3 x 50 sq. mm
c) 3 x 25 sq. mm
d) 3 x 6 sq. mm
Laying and fixing of one number PVC insulated, PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall / roof surface as required a) upto 35 sq. mm (clampped with 1 mm thick saddle)
b) Above 35 sq. mm and upto 95 sq. mm ( clampped with 25 x 3 mm MS flat clamp)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. a) upto 35 sq. mm
b) Above 95 sq.mm and upto 185 sq. mm
Supplying and laying control wiring with multicore copper standard conductor of following sizes in PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house & out side on surface/existing cable tray complete with connections at both ends as required. a) 8 x 2.5 sq. mm
b) 2 x 2.5 sq. mm
Supplying and making end termination with brass compression gland and aluminium lungs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3.5 x 95 sq. mm
b) 3 x 50 sq. mm
c) 3 x 25 sq. mm (25 mm)
d) 3 x 6 sq. mm (22 mm)
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick i/c accessories, and providing masonary endosure with cover plate having locking arrangement and watering pipe of 2.7 mtr, long etc. with charcoal/coke and salt as required.
Providing and fixing 25 mm x 5 mm GI strip in 40 mm dia GI pipe from earth electrode i/c connection with GI nut, bolt, spring, washer, escavation and refilling etc. as required
Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connection etc as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Providing, laying, testing and commissoning of 'C' class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolt, gaskets etc. in ground including excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. a) 150 mm dia
b) 80 mm. Dia
Providing, laying, testing and commissoning of Class 'C' heavy duty MS Pipe conforming to IS 1239/3589 including fittings like elbows, tees, flanges, tapers, nuts bolt, gaskets etc. on surface and providing cement concrete blocks as supports and painting with two or more coats of synthetic enamel paint of required shade complete as required. a) 200 mm dia
b) 150 mm dia
c) 100 mm dia
d) 80 mm dia
e) 65 mm dia
f) 50 mm dia
g) 40 mm dia
h) 32 mm dia
i) 25 mm dia
j) 15 mm dia
S/I/T/C of single headed internal hydrant landing valve with instantaneousgun metal couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal cap and chain as required.
S/I/T/C of single headed External hydrant landing valve with instantaneousgun metal couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal cap and chain as required.
Supplying and fixing, testing & commissioning of butterfly vave (Manual) CI Body SS Disc Nitrile Rubber seal & O-Ring PN 16 Pressure Rating as specified. a) 150 mm dia
b) 100 mm dia
c) 80 mm dia
Supplying and fixing, testing & commissioning of double flanged sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets, confirming to IS 780 of following sizes as required. a) 200 mm dia
b) 150 mm dia
c) 100 mm dia
d) 80 mm dia
Supplying, fixing, installation, testing & commissioning of non-return valve with dual plate of CI body SS plated vulcanized NBR seal flanged end & PN 16 pressure rating as specified. a) 150 mm dia
b) 80 mm. dia
providing and fixing "Y" strainer of Ductile CI Body flanged end with stainless steel strainer as specified. a) 150 mm dia
b) 80 mm dia
upplying and fixing 63 mm dia, 15 mtr. Long RRL hosc pipe with 63 mm. dia Male and Female stainless steel duly binded with G.I. wire, rivets etc. conforming to IS 636 (type-A) as required.
Supplying and fixing First-Aid-Hose Reel with MS construction spray painted in Post office red, conforming to IS 884 with up to date amendments, complete with the following as required. a) 30 m. long 20 mm (nominal internal) dia water hose Thermoplastic (Textile reinforce) Type-2 as per IS: 12585 b) 20 mm (nominal internal) dia gun metal globe valve & stainless steel nozzle. c) Drum and brackets for fixing the equipments on wall. d) Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe.
Supplying & fixing 63 mm dia stainless steel branch pipe with 20mm (nominal internal diameter) size stainless steel nozzle conforming to IS 903, subitable for instantaneous connection to interconnect hose pipe coupling as required.
Supplying and Fixing 4 way fire brigade connection of cast iron bodywith 4 Nos. Gun metal male instaneous inlet couplings complete with cap and chain as required for 150 mm dia MS pipe connection, conforming to IS 904 as required.
Supplying and Fixing 3 way FBC of CI body with 3 Nos. Gun metal male instaneous inlet couplings complete with cap and chain as required. For 150 mm dia MS pipe connection, conforming to IS 904 as required.
Supply, installation, testing & commissioning of 100 mm dia size 0 to 10 Kg/cm2 range, pressure guages with all accessories like niddle valve etc.
Supplying and fixing Air Vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia Gun metal wheel valve, with required accessories, pressure guage and painting with synthetic enamel paint of approved shade as required.
Supplying and Fixing of hose cabinet of size 900 mm x 600 mm x 500 mm made of 2 mm thick Ms sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate external hydrant with butterfly valve, 2 Nos, 15 mtr, Long Hose pipe, 1 No branch pipe, mounted on wall OR raised brick platform & duly painted with Post Office red externally and white internally with synthetic enamel paint complet in all respect, for external hydrant, as required.
S.I.T.C Auto Air Vent - 15 NB
SITC-Turbine Type Flowmeters, Complete mating Flanges- for following line sizes & Clear water application Size 150 mm dia
Signages for fire fighting equipments, as per IS9457/IS12349 ( Size 100 mm x 400 mm)
Supply, Installation, testing & commissioning of Sprinkler Alarm check Valve of Max Service Pressure 175 PSI, Mounting Vertical, Flange Connection ANSI B 16.1, Factory Hydro Test Pressure 355 PSI rating, As Per NEPA 13 & NFPA 25, MOC - Housing-Cast iron, Seat Bronze, Clapper Bronze, Hand Hole Cover Cast iron with constant pressure trim, test alarm trim, water motor gong, pressure gauge, drain valve with mating flange and testing arrangement complete with operating accessories like pressure gauge, drains etc. Valve shall be FM approved Size 100 mm Dia
Supply, Installation, testing & commissioning of Flow Switch Flow switch Vane Type, Threaded connection, with IP type terminal box for wiring connection & the maximum working temperature of 2500C with flame proof protection. Sensine Element of SS 316. Flow switch shall be FM approved Size For 100 mm dia Pipe
Supply, Installation, testing & commissioning of Quartz Bulb Sprinkler K- 5.6, 57 Deg.C, Quick Response, Standard Coverage. With all fittings such as DI nipple etc. Sprinkler shall be FM approved pendent Type
Hitech Pipe Supports for hanging Pipe ( the standard Rod Length will be 0.50 Mtrs to 0.80 Mtrs) including tic rod, hi tech dampp & purlin damp. 50 mm dia
40 mm dia
32 mm dia
25 mm dia
Supply, Installation, Testing & commissioning of Ball Valves 3 Piece Design, Body - Forged or Cast Carbon Steel, Trim and Ball SS410, Seat SS410 Threaded End Size 50 mm Dia
25 mm dia
15 mm dia
Inspector's Test Connection with Orifice and Isolation Gun Metal Ball valves with screwed ends lever operated ASTM A105, TRIM 13% Cr. 800# including 25 NB dia. Pipes, fittings, Open Sprinkler, Coupling, pressure gauge, Sight glass & Wall mounted MS Box for better operations.
Standard Braided Flexible Hose of 0.75 Mtr. /1 Mtr. / 1.2 Mtr. / 1.5 Mtr. Length of 25 MM with connecting nipple, reducing nipple to sprinkler Head. Complete with accessories like bar fixing clamp, Support bar screw etc. to Fix the Flexible Hose with False Ceilling
NP3 Grade Hume Pipe 300mm dia
Structural Steel of suitable sizes for supporting of over ground pipes in Pump House, Hydrant System & Sprinkler System pipes, cabinets etc. with application of primer and painting. Price shall include for Seismic Bracing, anchor bolts and all fastning material.
Obtaining approval on Entire Fire Protection and Detection system from Local Fire Authority
Raw Water System: Raw Water Pump: SITC-Raw Water Submersible Pump of Capacity 2.5m3/hr. and Head - 35 Mtr. Complete with Control Panel, Cable, Frame, Suction and Discharge Manifolds with Valves and NRV and MOC: impellers Noryl Pump Shaft and Housing Stainless Steel AISI 410, all hardware Stainless Steel AISI 410 with ( one nos working and one nos stand by) Submersible Pump
SITC-Raw Water Distribution Hydropneumatic System of Capacity - 2.5 m3/hr. and Head - 35 Mtr. Complete with Control Panel, Cable, Frame, Pump With Motors, Suction and Discharge Manifolds with Valves and NRV, Hydropneumatic Tank and Pressure switch etc. with one stand by pump. (Water from Pump Room to Over head Tank)
SITC of I.S.1239 part I ERW Heavy Guage G.I. Plain ends pipes and as per Spec. 'C' Class Pipe with all fittings like elbow, bend, tee, reducer & flange including-Flow Direction Marking etc (Make: Jindal, Surya, Asian) Size 100 mm dia
80 mm dia
65 mm dia
50 mm dia
25 mm dia
15 mm dia
Supplying and fixing testing & commissioning of butterfly vave (Manual) Body SS Disc Nitrile Rubber seal & O-Ring PN 16 Pressure Rating as specified Size 65 mm
Supply, Installation, testing and commissioning of "Y" type Strainer of Ductile CI Pipe Body Flange End with Stainless Steel Strainer as Specified Size 65 mm
Supplying fixing installation, testing & commissioning of non-return valve with dual plate of CI body SS plated vulcanized NBR seal flanged end & PN 16 pressure rating as specified. Size 50 mm
Excavation 450mm Depth 1200 mm, back Filling with Compaction and min 100 mm sand bedding of Underground Pipes and the Testing for Compaction shall be done
SITC of Wrapping and Coating of Under Ground Piping with 4 mm Pypkot anti Corosive tape
SITC of pressure gauges with all accessories like niddle-valve etc. Range 0-5 Kg/cm2, Dial -100 mm, Size - 1/2" BSP (Make: Hguru, Waree)
SITC of I.S.1239 part I ERW Heavy Guage G.I. plain ends pipes and as per spec. 'C' ClassPipe with all fittings like elbow, bend, tee, reducer & flange including-Flow Direction Marking etc (Make: Jindal, Surya, Asian) Note: For Taking water connection from Bore Well point to Main Water storage Tank Size 80mm
HVAC System Supply of Variable Ref. flow Multi V Ivsystem a) 45 HP
b) Connection Kit
c) Testing and Commissioning Charges of Handling of refrigerent and handling of outdoor unit
Supply, Installation, testing and commissioning of Indoor Unit four (4) way round flow CASSATTE UNIT Capacity a) 1.5 TR cassette ac
b) 2 TR cassette ac
Remote Controls a) Corded remote for ductable
b) Cordless remote for concealed type
c) Central remote for entire system
Refrigerant Joints
Supply & Installation of the following components of VRF System a) All refrigerant piping between indoor & Outdoor units duly insulated and as per specifications. All piping inside the room shall be properly supported with
b) All control cabels between indoor and outdoor unit laid in PVC pipe and clamped.
c) M.S. Structure for installing VRF outdoor / indoor units duly epoxy coated floor mounted type
d) PVC Drain piping for the units with insulation 25 mm Dia
PVC Drain piping for the units with insulation 40 mm Dia
Copper Piping with insulation
All Control cabels between indoor and outdoor unit laid in PVC and Clamped
M.S Structure for installing outdoor/indoor units duly
Testing, Commissioning and Gas Top Up
Exhaust Fan 6" exhaust fan of 50 cfm with gravity louvers
Automatic Fire Alarm System Supply, Installation, Testing And Commissioning of complete intelligent, addressable, analog, zoned non-coded and electrically supervised, multiple loop fire alarm and detection system, including initiating devices and notification appliances. The system shall interface with 3rd party systems and perform monitoring, controlling, annunciating functions. All equipment furnished and mentioned shall be new and latest and products of single manufacturer as listed in techynical specifications, all requirements of contract works. The system shall be modular and expandable and shall include following but not limited to Microprocessor based Networkable analogue addressable fire alarm control panel with 640 character LCD display, The panel should be equipped with 0.2 numbers of loop expandable up to 0.4 loop with 20% spare capacity with each loop shall have a capacity of 120 analogaddressable devices in one loop. The panel shall be complete with integrated a channel Digital Voice Evacuation and 2 ways Communication fire Fighters System capable to supervision of all the speaker circuits with adequate zone control and accessories. The system shall be equipped with necessary Digital Audio Ampilifier capable of processing one of 8 audio channels and total of 50W at 70.7 VRMS output along with necessary endosures. The DAA shall be fully monitored for fault and alarm reporting. The proposed Digital Amplifiers shall not be rall mounted/ dependant on Fire Panel CPU for operation, (Failure of Fire Panel CPU shall not result in failure of Ampilifier operation (UL 9th Edition Approved)
SITC of Analogue Addressable Microprocessor based Passive type Repeater contain central processing unit, LCD Display complete with battery backup of 24 hours operation and 30 minutes alarm operation with battery charger etc. System integrate with life safety facilities i.e. HVAC, PA Lift or elevator by providing NO/NC contacts The Repeater shall be UL Listed / FM Approved
Supply, Installation, Testing & Commissioning of Analog Addressable Photo-electric type, smoke detector with BL-Colour LED indication, electronic addressing, multiple sensitivity levels, pre-alarm option, non-volatile memory having provision for self diagnostics and history log, dust and dirt resistant with drift compensation, plug-in design, with compatible mounting bases with built-in isolator, junction box and other accessories as required and working on 24 VDC supply all complete as required. The detectors shall be UL/FM approved.
UL listed, Flush or surface mounted Manual Call Point in manufacturers prescribed matching red enamel outlet box complete with key operated test-reset lock. The word FIRE shall appear ini front of station as per all requirement of technical specifications & contracts works.
Wall mounted Strobe with suitable mounting arrangement, multi taps for sounder and visual characterstics as per all requirements of technical specifications & contract works
Addressable interface Devices: Providing, fixing, testing and commissioning UUL listed, modules complete with mounting arrangement on north American junction box as per technical specifications and all requirements of contract works. Following devices shall be used but not limited to: a) Monitor Module for monitoring of 3rd party services;
b) Control Module for Strobes.
c) Isolator Module for fault Isolator.
Ceiling Mounted Speaker for voice evacuation announcements with multi taps from 1/4 to 2 Watts complete as required at site.
Addressable Fire Fightrers Telephone Jack with module for addressing as per all requirements of technical specifications & contracts works.
Fire Fighters Telephone Reveiver as per all requirements of technical specifications & contracts works
SITC of Control Cables (FRLS)- 1.1 KV Grade to IS: 1554, Stranded Copper Conductor, PVC insulated, PVC Inner Sheathed, Armoured with accessories of reputed make. 2C x 1.5 sq m Cu. Ar. Cable 4C x 1.5 sq mm Cu. Ar. Cable
FIRE EXTINGUISHERS & MISC. ITEMS Providing and fixing Carbon-di-oxide fire extinguishers consisting of welded M.S. cylindrical body, squeeze lever discharge valve fitted with internal discharge tube, 30cms long high pressure discharge hose, discharge nozzle, suspension bracket, confirming to IS : 15683 finished externally with red enamel paint and fixed to wall with brackets with rawi plug/dash fasteners complete with internal charge. Capacity 4.5 kg. ISI Marked. (Contractor should submit test certificate form manufacturer along with serial number of every extinguishers supplied.
Supply & Installation of 6 Kg ABC Extinguisher of stored pressure type with mono ammonium phosphate discharge tube and pressure gauge complete.
a) Capacity 4 Kg. (IS: 15683)
Supply & installation of 2 Kg ABC Extinguisher of stored pressure type with mono ammonium phosphate discharge tube and pressure gauge complete
Supply & Installation of Fire Bucket with Canopy and Stand-9 Ltrs Capacity (4 Buckets/Set)
NASA- 227 Or equivalent, Clean Agent of 02 Kg for Lab, Server Room, Panel Room etc
Providing and fixing of self illuminated / auto glow "EXIT" signs printed on photoluminescent sheet containing self illuminated base chemical, of appropriate size not less than 400 x 150 mm, suspended from ceiling or fixed to the walls with accessories as required and as directed at site.
Electrical Work Supply only AC Ceiling Fan 1200 mm 48" size of ORTEM / Bajal Make complete in all respect upto the entire satisfaction of the Engineer-in-charge of work (N.S.)
Supply only Exhaust Fan of 9" size complete in all respect upto the entire satisfaction of the Engineer in-charge of work (N.S.)
Supply only Exhaust Fan of 12" size complete in all respect upto the entire satisfaction of the Engineer-in-charge of work (N.S.)
Supply only MAGIC MOON LED LIGHT 20W, energy efficient fitting of Bajaj/CG make complete in all respect upto the entire satisifaction of the Engineer-in-charge of work (N.S.)
Supply only CUBIE LED LIGHT 15 W, energy efficient fitting of Bajaj/CG make complete in all respect upto the entire satisfaction of the Engineer-in-charge of Work
Supply only 20 watt LED of Bajaj/Philips make complete in all respect upto the entire satisfaction of the Engineer-in-Charge of work
Supply only 30 watt LED of Bajal/Philips make complete in all respect upto the entire satisfaction of the Engineer-in-Charge of work
Supply only 120 WATT LED LAMP (ATTACHED QUOTATION)
Supply only Electric Motor 1 Hp
Supply only Electric Motor 1.5 HP
I.T.C. OF PCC cum PDB-01 for ground floor (App. Dimension In LxBxH - 1200mm x 600mm x 1500mm
I.T.C. OF PDB-02 FOR FIRST FLOOR
I.T.C. OF 90 KVAR APFC PANEL
I.T.C. OF PDB-03 FOR SECOND FLOOR
I.T.C OF PDB-03 FOR THIRD FLOOR
I.T.C OF DB for incomer with 40A DP MCB and 16A, 6A SP MCB
S.I.T.C of 7.5 KVA TPN in put and out put true RMS on line type UPS with inbuilt isolation Transformer and SMF batteries. The ups shall have minimum 30 min, back up at 75% load.
Supply, installation, testing and commissioning of lighting fixtures and accessories. (Down rods, lighting channels and supports required for installation of lighting fixtures shall be measured separately.) a) S.I.T.C of 4-Feet LED Fixture with Max. 2x20W LED TUBE, power consumption of each tube shall be max. 20W with min. 2000 system lumens, tube light shall be built in polycarbonate housing which acts as HET Diffuser. Batten housing shall be suitable for mounting 2 nos. of LED tube made up of CRCA powder coated construction. LED shall be 6500k. All the LED's shall be LM80 Complied as per L70 standard for Min 10000 Hours. Driver shall be 2kv Surge protected CCTV operation having voltage range of 85-265V. DC Output of driver shall be less than 60V DC as complied to SELV Norms.
b) S.I.T.C of IP-65 protected Max. 100 LED Flood light with min. 13000 system lumens, built in die cast Aluminium housing for proper heat dissipation. LED Make shall be CITIZEN, CREE and NICHIA of COB LED with CCT 5000k. All the LEDs shall be LM80 Complied as per L70 standard for Min 10000 Hours. Driver shall be 4kV Surge protected CCCV operation having voltage range of 90-295V. DC Output of driver shall be less than 60V DC as complied to SELV Norms
c) S.I.T.C of Recess Mounted 2x2 LED Fixture with Max. 31 W power consumption having min. 3000 system lumens, CRCA Powder coated housing and HET Diffuser with full glow. LED Make shall be Citizen, CREE and NICHIA of SMD type in 5700k CCT. All the LEDs shall be LM80 Complied as per L70 standard for Min 10000 Hours. Driver shall be 2kv surge Protected CCCV operation having voltage range of 150-270V.
d) S.I.T.C of Recess Mounted LED Downlighter with Max. 15W power consumption having min. 1400 lumens, CRCA Powder coated housing and HET Diffuser. LED Make shall be CITIZEN, CREE and NICHIA of SMD type in 6000k CCT. All the LEDs shall be LM80 Complied as per L70 standard for Min 10000 Hours. Driver shall be 2 kV Surge protected CCCV operation having voltage range of 150-270V.
e) S.I.T.C of Single arm wall mounting bracket and MCB for control to install lighting luminaries (LDB)
f) S.I.T.C of Wall mounted emergency light with battery back up. The equipment shall be with LED based of adequate wattage
g) Footlight-warm white 2 to 5 watts, metalic frame suitable to caste in wall/concrete
a) Maintenance free chemical type earthing electrode of 3 Mtr long, 17.2 mm dia copper coated rod of 250 microns with ready made earthing chamber and disconnecting links as defined in the earthing electrode drawing
b) 50x8 mm Hot dip Gi Strip
d) S.I.T.C of Advanced Lightning Protection System with Stainless Steel body, working on the principle of (ESE) Early Streamer Emission technology, having a coverage radius of 79 mtrs when mounted at a height of 5 mtrs giving level I protection and anticipation emission time of 60 micro second, complying to NFC 17 102 as described in OEM catalogue
a) 300 x 50 mm wide perforated type
b) 50 x 50 mm wide perforated type
c) 32 MM MS CONDUIT
a) Supply and installation of following items: Panel room safety devices Rubber mat of 1.1 KV 1x2 Mtr
b) Danger boards LT
c) Shock treatment charts
d) First aid box
e) Portable Emergency lights (legrand make)
Supply of air-conditioning VRV system. The system to facilitates the operation & control of individual room. The system shall be able to cater the partial load which can be as low as 10% of the total load. Each outdoor unit shall have 100% inverter Based Scroll Compressors & they should be able to operate individually even if one is under maintainence. Each indoor unit has Electronic Expansion Valve which senses the temperature based on variation of the load and conveys the same for the outdoor modules to respond accordingly. Proposed AC System will be microprocessor controlled inclusive of safety factor & gadgets. (60000 per HP) a) System 1 (Shops & ATMs) 52 HP
b) System 2 (Restaurants, Apparel Store, Electrical Room & Bank) 56 HP
Fabricated supports for cable trays, panels, equipments of MS Painted with two coats of primer and two coats of finish enamel paint. Anchor fasteners 100x12
street light, 4 mtrs height, 60MM Dia MS pipe, Minimum LUMEN 5000
street light, 4 mtrs height, 60MM Dia MS Pipe, Minimum 8000
220KVA DG set along with cable, earthing and all accessories fuel pump, silencer, radiator, batteries etc.
Solar System (canadian PV) with min eff. 16% suitable for rooftop with string inverter and MS hot dip galvanised mounting structure
S.I.T.C., Glanding and termination of following L.T. cables with heavy duty copper lugs, heavy duty double compression cable glands and PVC hood. 1.1KV, XLPE, AL, AR, CABLE 3.5C x 300 Sq. mm
3.5C x 185 Sq. mm
3.5C x 25 Sq. mm
S.I.T.C of 1 x 70 sq. mm. Bare Copper Twisted Condutor or 0.5 mm thick PVC insulated cable
S.I.T.C of mounting structure for fixing of LA
S.I.T.C of Distribution boards and power sockets Industrial type with double door arrangement for DB's Receptacles panel with 63A incomer MCB, 1x32A TPN, 2x20A SPN industrial power socket and plug with individual ELCB control for each socket. The unit shall be supplied with plug with safety interlocks duly mounted in enclosure
1 Phase, 20A, SPN+E Industrial type POWER SOCKET WITH 20A MCB. The unit shall be with self interlocking arrangement with plug and socket.
Bidder Name
Amount
Shree Construction Co.
Deepak Kumar Contractor
Deepak Kumar Contractor
Deepak Kumar Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid