Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹16.6 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹18.9 L+₹2.2 L (13.4%)Admitted-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Admitted-Finance | ||
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical No EMD or Fee received |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
23 Oct 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer PHED City Dn Barmer
Executive Engineer PHED City Dn Barmer
Construction and Commissioning of Clear Water Reservoir CWR 500 KL at Jalipa Head Works against the Old Damaged CWR, including Demolition of the Existing Structure Under DMFT
2026_PHCJO_603920_3
2026-27/35
Open Tender
Civil Works - Water Works
Percentage
180 days
Barmer
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer PHED City Dn. Barmer
₹60,000
Yes
2 Nov 2026
20 Oct 2026
23 Oct 2026
20 Oct 2026
23 Oct 2026
20 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Based on PHED Revised BSR 2023 Exclusive of GST | - | - | - | - |
| 2 | Construction of RCC (Dome type) Clear Water Reservoir of following capacity as per Scope of work and Technical specification, consisting of the following main activities: - | - | - | - | - |
| 3 | a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction.
b) Excavation in all types of soil, PCC below foundation & all RCC Work.
c) All the GLSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill.
d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall giving.
e) Successful hydro test and water tightness test as per I.S. code.
f) Providing and applying three coats of anti-carbonation paint on the roof Slab.
g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure.
h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from top bottom Slab inside container. Providing and fixing water level indicator (Float type). | - | - | - | - |
| 4 | h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type).
i) Providing and fixing MS ladder from ground to top slab.
j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide.
k) Providing and fixing of 150mm wide water bar for the construction joints in the container.
l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir.
m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. | - | - | - | - |
| 5 | Rates for RCC Partially Underground type clear water reservoir SBC 12.5 T/sqm, SEISMIC ZONE-2 & 3. | - | - | - | - |
| 6 | 500 KL capacity ( Jalipa HW ) | 5,00,000 | Litre | 4.73 | ₹23,65,000 |
| 7 | Construction of boundary wall of Brick/ stone masonry as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below:
1. Depth of foundation- 900 mm.
2. PCC in M-10, width -900 mm and thickness 100 mm,
3. Stone masonry in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D)
4. Superstructure work: Stone masonry in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm.
5. Cement mortar pointing on Stone masonry and cement mortar plaster 20 mm thick on brick masonry in CM 1:6.
6. Expansion joint shall be on every 30 mtr.
7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided.
8. Pillar for main gate 350x350 mm in size is part of boundary wall.
9. Cement paint of approved colour in 3 coat shall be done. | 25 | Mtr | 4,932.2 | ₹1,23,305 |
| 8 | Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge. | - | - | - | - |
| 9 | MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet) | 505 | Kg | 106.78 | ₹53,923.9 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.31 MB
2A_2B_merged.pdf
Tender Documents • 3.65 MB
BOQ_1071989.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .