Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.2 LAccepted-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹32.7 L+₹43,361.22 (1.34%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹32.8 L+₹56,001.16 (1.74%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹33.2 L+₹88,821.56 (2.75%)Rejected-Finance | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹33.3 L+₹1.1 L (3.36%)Rejected-Finance | L5 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | L and S ENTERPRISES L2 | SANJEEV CONSTRUCTIONS L7 | SHANTI MARKETING AND SERVICES L3 | omsai thermax engineers L1 | MS ENTERPRISES L10 | M/S DIVIJA BUILDERS L4 | DPS sales and services india L8 | K LAKSHMAN SINGH AND CO L5 | Poorvi Enterprises L9 | Srinivash Engineers L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | S & F panel and its connections and supply and install, testing and commissioning of Out door LT feeder panel factory made cubicle type of suitable size and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of 600 A Capacity Al strip 3 phase and half neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following | 1 | Each | 1,98,000 ₹1,98,000 | 1,62,000 ₹1,62,000 | 1,30,000 ₹1,30,000 | 1,63,800 ₹1,63,800 | 1,33,333 ₹1,33,333 | 1,80,000 ₹1,80,000 | 1,52,424 ₹1,52,424 | 2,00,000 ₹2,00,000 | 1,09,000 ₹1,09,000 Lowest | 1,30,000 ₹1,30,000 |
| 1.01(a) MCCB 4 Pole 400 Amps 36KA -01 No. MIcro processor based (incomer) (b) MCCB 4 Pole 100 Amps 36KA -02 No. Thermal Magnetic release (Outgoing) (b) MCCB 4 Pole 63 Amps 36KA -02 Nos. (Outgoing) (c) MCCB 4 Pole 32 Amps 25KA -01 Nos. (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 500/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. | |||||||||||||
| 2.00 | S & F panel and its connections and supply and install, testing and commissioning of Out door LT feeder panel factory made cubicle type of suitable size and 3.15 mm thick CRCA sheet outdoor type vermin proof with Aluminium bus bar of 400 A Capacity Al strip 3 phase and half neutral connections with neutral colour coded with heat and shrinkable PVC sleeves, with necessary supports, angle iron frame work and stand, locking arrangements and painted with one coat of red oxide primer and two coats of powder coated paint with suitable size of panel control copper wiring, accessories are fitted on suitable insulator all housed in suitable bus bar chamber and provision and fixing of digital Voltmeter, Ammeter with built in selector switch, CTs of suitable ratio, and pilot indication lamps complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands incl PCC foundation etc complete testing and commissioning complete and consisting the following | 1 | Each | 1,55,700 ₹1,55,700 | 1,53,000 ₹1,53,000 | 1,20,000 ₹1,20,000 | 1,53,000 ₹1,53,000 | 1,13,633 ₹1,13,633 | 1,86,000 ₹1,86,000 | 1,43,184 ₹1,43,184 | 2,00,000 ₹2,00,000 | 1,09,000 ₹1,09,000 Lowest | 1,32,000 ₹1,32,000 |
| 2.01(a) MCCB 4 Pole 250 Amps 36KA -01 No. Micro Processor based (incomer) (b) MCCB 4 Pole 100 Amps 25KA -01 Nos. (Outgoing) (d) MCCB 4 Pole 63 Amps 25KA -05 Nos. (Outgoing)` (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces. | |||||||||||||
| 3.00 | Supply, Installation, test and Commissioning factory fabricated, out door type, LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :– | 2 | Each | 41,400 ₹82,800 | 36,000 ₹72,000 | 25,000 ₹50,000 Lowest | 33,300 ₹66,600 | 26,333 ₹52,666 | 1,81,900 ₹3,63,800 | 40,914 ₹81,828 | 65,000 ₹1,30,000 | 25,000 ₹50,000 Lowest | 26,000 ₹52,000 |
| 3.01(a) Aluminium bas bar 200amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,36 KA Breaking capacity 4 pole Themalmagnetic release duly connected to Bus Bar As IN COMING - 01 Nos | |||||||||||||
| 4.00 | Supply, Installation, test and Commissioning factory fabricated, out door type, LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– | 2 | Each | 36,000 ₹72,000 | 32,400 ₹64,800 | 22,000 ₹44,000 Lowest | 31,500 ₹63,000 | 22,333 ₹44,666 | 33,000 ₹66,000 | 40,914 ₹81,828 | 68,000 ₹1,36,000 | 25,000 ₹50,000 | 24,000 ₹48,000 |
| 4.01(a) Aluminium bas bar 100amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 63 amps ,415 volt ,36 KA Breaking capacity 4 pole Thermalmagnetic release duly connected to Bus Bar As IN COMING - 01 No | |||||||||||||
| 5.00 | Supply, Installation, test and Commissioning factory fabricated, out door FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– | 2 | Each | 36,000 ₹72,000 | 31,500 ₹63,000 | 15,000 ₹30,000 Lowest | 29,700 ₹59,400 | 20,333 ₹40,666 | 36,000 ₹72,000 | 40,914 ₹81,828 | 70,000 ₹1,40,000 | 43,000 ₹86,000 | 22,000 ₹44,000 |
| 5.01(a) Aluminium bas bar 100 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 32 amps ,415 volt ,36 KA Breaking capacity 4 pole Thermalmagnetic release duly connected to Bus Bar As IN COMING - 01 Nos | |||||||||||||
Tender Value
₹38.8 L
EMD Value
₹77,500
Closing Date
17 Mar 2025, 6:00 pmClosed
GE (UTILITY) SECUNDERABAD
GE UTILITY SECUNDERABAD MUDFORT SECUNDERABAD-500003
SPECIAL REPAIR FOR CONVERSION OF LOW TENSION OVERHEAD CABLE TO LOW TENSION UNDER GROUND CABLE AT OLD ASSAYE LINES AND PROVISION OF 250KVA VOLTAGE STABILIZER AT MRI SCAN BLDG MH UNDER GE(U) SECUNDERABAD
2025_MES_698995_1
GE (U)/SEC/TOKEN 44 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE (UTILITY) SECUNDERABAD
₹77,500
Yes
6 Oct 2025
22 Feb 2025
22 Mar 2025
22 Feb 2025
17 Mar 2025
10 Mar 2025
Amount
(a) MCCB 4 Pole 400 Amps 36KA -01 No. MIcro processor based (incomer) (b) MCCB 4 Pole 100 Amps 36KA -02 No. Thermal Magnetic release (Outgoing) (b) MCCB 4 Pole 63 Amps 36KA -02 Nos. (Outgoing) (c) MCCB 4 Pole 32 Amps 25KA -01 Nos. (Outgoing) (d) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 500/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces.
(a) MCCB 4 Pole 250 Amps 36KA -01 No. Micro Processor based (incomer) (b) MCCB 4 Pole 100 Amps 25KA -01 Nos. (Outgoing) (d) MCCB 4 Pole 63 Amps 25KA -05 Nos. (Outgoing)` (e) Three phase Panel mounted Digital type Voltmeter meter 0-500 Volts, Ammeter 400/5A LT-CT operated complete - 01 Set (e) Indicating type lamp for Red, Yellow and Blue phases - 01 Set Note : (a)All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls etc including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces.
Supply, Installation, test and Commissioning factory fabricated, out door type, LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof, Double door with both side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level complete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Testing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,36 KA Breaking capacity 4 pole Themalmagnetic release duly connected to Bus Bar As IN COMING - 01 Nos
Supply, Installation, test and Commissioning factory fabricated, out door type, LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 100amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 63 amps ,415 volt ,36 KA Breaking capacity 4 pole Thermalmagnetic release duly connected to Bus Bar As IN COMING - 01 No
Supply, Installation, test and Commissioning factory fabricated, out door FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of suitable size with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embedded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs, and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 100 amps - 01 Nos, supported with suitable size of heavy duty porcelain stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 32 amps ,415 volt ,36 KA Breaking capacity 4 pole Thermalmagnetic release duly connected to Bus Bar As IN COMING - 01 Nos
Supply and lay in trenches/fixed to walls/poles etc and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 4 Core 10 Sqmm incl taking out of existing cable all as directed.
All as per item no 6.00 above but 4 Core 16 Sqmm
All as per item no 6.00 above but 4 Core 25 Sqmm
All as per item no 6.00 above but 3.5 Core 35 Sqmm
All as per item no 6.00 above but 3.5 Core 50 Sqmm
All as per item no 6.00 above but 3.5 Core 70 Sqmm
All as per item no 6.00 above but 3.5 Core 150 Sqmm
All as per item no 6.00 above but 3.5 Core 240 Sqmm
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in hard soil complete all as specified and as directed.
M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for coping of pole complete all as directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed
M&L filling EARTH cushioning of laying of cables to the full width of excavated trench 8 cm thick before laying the cable and 15 cm above the cable, gently punned down, stretching and testing of cable on transformer yard etc complete all as specified and directed. Note :- Thickness of sand cushion after punning down (i.e 18 cm) shall be measured for payment.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 16 to 50 Sqmm, 3.5 Core complete all as specified and directed.
Supply, lay, commissioning and testing of cable jointing Kit Heat shrinkable type for 1100 V grade cable for straight through joint with jointing material and accessories suitable for LT UG cable of size 70 to 95 Sqmm, 3.5 Core complete all as specified and directed.
Supply and install street light timer panel including, astronomical digital timer, contactor 3 phase MCB for incomer and outgoing for overload and short circuit protection , prewire ready to use & locking arrangement Cat part No IHXTSS0312A of make Havells or equivalent in Siemens/Schneider
S&F pole mounted junction box of IP55 rating, with end termination connectors and necessary insulators alongwith MCB 6-32 Amps SP, clamps to fix the box with poles including with necessary size of cable gland to secure street light cables complete all as specified and directed
Dismantling LT steel tubular pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2(using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 TYPE C2 (USING 20MM GRADED STONE AGGREGATE) IN BOTH FOUNDATION AND COPING OF POLES ALL AS SPECIFIED IN SSR part 1 2009 and applying two codes of aluminium paint to pole surface all as directed by Engineer in charge
Supply and laying GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and laying GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Supply and laying GI tubing light grade of size 80 mm for cable protection on road/drain/floor/pole including necessary clamps 40x4mm.
Dismantling of damage / broken coping of PCC/steel pole of any size and and removing the debris from site including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and coping of poles all as specified in SSR Part I-2009 complete all as directed by Engineer-in-Charge. Complete all as specified and directed
Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of underground cable and filling back with excavated soil up to 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
Dismantling insulators any type, any size
Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
Dismantling of ACSR or AAC conductors
Dismantling of Service wire of any size and type
Supply and drawn sub main wiring with two runs of 1.5 Sq mm single core PVC insulated unsheathed cable up to and including 1100 volts grade with multistranded copper conductor drawn through and including non metallic PVC rigid conduit accessories surface type on walls, floors etc including one run of 1.5 Sqmm PVC insulated copper conductor for earth continuity wire all as specified (Note : Two runs of copper conductor and one run of copper earth wire including PVC conductor will be measured and paid as one unit only) (For Street Light connection from Junction Box to Street Light)
Earthing complete with galvanised steel earth plate electrode 60x60x6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to using galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no 3 connected to earthing test point as specified or indicated including testing and completion
Supply, install, test and commissioning of servo controlled Voltage stabiliser for automatic operation, three phase naturally oil cooled out door type with neutral transformer confirming to BIS : 9815 (Part -II) with latest amendments and digital Volt meter, Ammeter and Frequency meter suitable CT's for ammeter, Voltage adjustment for increment and decrement etc with the following specifications: (a) Rated Capacity 250 KVA Out door type with IP-55 grade of protection. (b) System 03 Phase , 50Hz, AC Supply (c) Input Voltage 360V to 480V (d) Out put voltage Set 415V(+/-)1.0% speed of correction 6V/Sec (e) Operating Line Frequency : 50 Hz (f) Type of Cooling Naturally Oil Cooled (g) Type of System Unbalanced (h) Operating Temp 20 to 50⁰ C (j) High/Low Voltage cut off feature
MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) of capacity 315-400 Amps, 4 Pole, 35 KA, 415 Volt - 2 No's
All as per item No 39.01 here in before but of capacity 250 Amps, 4 pole, 25 KA - 02 No's
S&F Onload changeover switch 4P 400 Amps-01 No's
(g) LED indicating lamps with holder for main supply indicating RYB - 01 set(03 Nos)
(h) Instrument fuse holder, fused 4 amps - 06 Nos. Note: i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (ii) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the quoted rate
Supply and lay GI tubing 100 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5m below the normal ground level connected with GI strip 32 x 6mm by means of bolts, nuts, check nuts & washers of galvanised iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50m, with and including PCC chamber in PCC (1:2:4), type B1,using (20mm graded stone aggregate),"mild steel angle iron frame" made out of MS angle iron of size 40x40x6mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20mm dia medium grade pipe for watering 40mm dia light grade, GI pipe for lead protection in and including alternate layers of charcoal dust and common salt complete all as shown in electrical "plate No '3' and connected to earthing test point all as specified and directed.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or fixed to pole GI strip 32 x 6 mm all as specified and directed.
L and S ENTERPRISES (BID ID -3263617)
SHANTI MARKETING AND SERVICES (BID ID -3264615)
M/S DIVIJA BUILDERS (BID ID -3265052)
K LAKSHMAN SINGH AND CO (BID ID -3259890)
Srinivash Engineers (BID ID -3262985)
SANJEEV CONSTRUCTIONS (BID ID -3264462)
DPS sales and services india (BID ID -3263532)
Poorvi Enterprises (BID ID -3264059)
MS ENTERPRISES (BID ID -3264918)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .