Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.2 CrAccepted-AOC B 148 2ND FLOOR B BLOCK NEAR MOTHER DIARY SECTOR 8 DWARKA NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | ₹2.2 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹2.3 Cr+₹4.4 L (1.98%)Rejected-Finance VEER KUNWAR SINGH COLONY BEHIND QTR NO H 150 HINNO RANCHI 834002 | RANCHI | JHARKHAND | 834002 | ₹2.3 Cr+₹4.4 L (1.98%) | L2 | Rejected-Finance Quoted Higher than L1 |
| 3 | L3₹2.4 Cr+₹15.0 L (6.76%)Rejected-Finance HOUSE NO 6 ROAD NO 7 KILBURN COLONY HINOO RANCHI 834002 | RANCHI | JHARKHAND | 834002 | ₹2.4 Cr+₹15.0 L (6.76%) | L3 | Rejected-Finance Quoted Higher than L1 |
| 4 | L4₹2.5 Cr+₹26.9 L (12.1%)Rejected-Finance 801 VENUS BENECIA PAKVAN DINING LANE OPP RAJPATH CLUB S G HIGHWAY BODAKDEV AHMEDABAD 380053 | AHMADABAD | GUJARAT | 380053 | ₹2.5 Cr+₹26.9 L (12.1%) | L4 | Rejected-Finance Quoted Higher than L1 |
| 5 | Rejected-Technical PLOT NO 113 GURUSANGAT DARBAR ROAD SINDHI COLONY KHAMLA NAGPUR 440025 | NAGPUR | MAHARASHTRA | 440025 | - | - | Rejected-Technical Not Eligible. |
Tender Value
₹2.9 Cr
EMD Value
₹5.7 L
Closing Date
22 May 2023, 1:00 pmClosed
JGM(E-E)
B.M.Airport,Ranchi
ARMO of EandM Installations at BM Airport Ranchi. SH Providing Maintenance Services for EandM Installations of NITB, Sub-station, AAI Residential Colony, Old TB, CISF barrack, MT pool andcargo division for the year 2023-25.
2023_AAI_153007_1
AAI/RNC/ARMO-NITB/2023
Open Tender
Electrical Works
Item Rate
730 days
B.M.Airport
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,180
Yes
₹5.7 L
Yes
6 Jul 2023
1 May 2023
23 May 2023
1 May 2023
22 May 2023
1 May 2023
1 May 2023 - 12 May 2023
Amount
Sub Head - I : Operation and Maintenance Operation and Periodical Maintenance of 33 KV/433V sub station, 5x750 KVA DG sets, Internal and External Electrical Installations of Integrated Terminal Building, New Sub Station, AAI Residential Colony, Amenities in Car Parking & near ITB, Car Parking & ITB Road St. Lighting, Internal and External Electrical Installations of old terminal building , MT pool , CISF barrack ,cargo division, Approach Road & old and new Car Parking Lights etc. by deploying adequate manpower as per the conditions of contract involving operation, repairs & maintenance / faults / breakdowns and taking rectification action, ensuring serviceability / satisfactory working condition of the systems, preventive maintenance on daily/ weekly/ monthly/ quarterly/ yearly basis, maintenance of records/documentation etc. as per scope of work given in special conditions and technical specifications of contract on all day including Sundays & Holidays.
I st year
II nd year
Sub Head - I : Operation and Maintenance Coordination for renewal of CEA Licence at New terminal Building and runway power house by providing assistance in submission of drawings, reports, documents etc. including getting site inspection by CEA authorities to obtain approval of licence and submission to AAI. Statutory govt. fees shall be paid by AAI derectly to CEA. Any associated works if necessary as per CEA observation during inspection shall be carried out by AAI through the AMC as required.
Sub Head - II : Repair and Painting Works Transportation of diesel from AAI authorised petrol pump to power house( to and fro 08 KM) in 200 Ltr. barrels/ drums including loading/ unloading (for 600- 800 Ltr.) per trip as and when required.
Sub Head - II : Repair and Painting Works Annual maintenance contract of Rockwell automation make (model : Allen Bradley) Micrologix 1400 PLC for automatic operation of 5 nos. of D.G. sets (AMF panel with synchronization).including control circuit from DG Sets to AMF panels, AMF panels, and other LT panels in Sub-Station.
I st year
II nd year
Sub Head - II : Repair and Painting Works AMC of hydraulic crash rated bollards and tyre killer
I st year
II nd year
Sub Head - II : Repair and Painting Works AMC of 250 KWp terrace mounted Solar panels along with inverter and other accessories as complete(Faulty spares will be provided by AAI).
I st year
II nd year
Sub Head - II : Repair and Painting Works Decorating City side of Airport with minimum 50 nos PAR Lights , 300 nos Led Rice lights , 20 nos flood lights giving tri colour effects or as per theme dicided by E-I-C during national holidays or festivals.
I st year
II nd year
Sub Head - II : Repair and Painting Works Servicing, maintenance and testing of L & T make Air Circuit Breaker - 1250/1000/800/630A FP, EDO complete as required.
I st year
II nd year
Sub Head - II : Repair and Painting Works Servicing, maintenance and testing of L & T make Air Circuit Breaker - 2500 A, FP, EDO complete as required.
I st year
II nd year
Sub Head - II : Repair and Painting Works Servicing, maintenance and calibration of earth fault and over load relay with secondary injection kit etc. of 05 nos. HT panel complete as required.
I st year
II nd year
Sub Head - II : Repair and Painting Works Servicing, maintenance and testing of 33 kV HT - Vaccum Circuit Breaker of Siemens make etc. complete as required.
I st year
II nd year
Sub Head - II : Repair and Painting Works Testing of BDV value of transformer oil at site as per direction of EIC
Sub Head - II : Repair and Painting Works Dehydration and filtration of transformer oil at site including testing for BDV before and after dehydration and filtration and submission of test reports etc. as required for power Transformers
I st year
II nd year
Sub Head - II : Repair and Painting Works Rewinding the following with copper winding wires of required size and heat varnishing etc. as required including less for dismantled copper wire etc. as and when required.
Ceiling fans upto 1400 mm
Exhaust fans upto 450 mm
Wall Fans
Replacement of ball bearing for above fans.
Sub Head - II : Repair and Painting Works Shortening height of Perimeter Light Poles at various location complete in all respect and as per instruction of EIC
Sub Head - II : Repair and Painting Works Providing and fixing vinyl sticker on the existing information signage board inside NITB of required design and letters. The letters in Hindi and English will be electro cut computerised automated to be transferred on existing polycarbonate sheet after removing the existing vinyl sticker complete as directed by engineer-in -charge as and when required.
Sub Head - II : Repair and Painting Works Painting of Fire fighting equipments i.e. Pumps, Hose cabinets, Pipes etc. with two coats of red synthetic enemel paint as approved by engineer-in-charge after scrubbing and cleaning the old paint from the existing surface.
Sub Head - II : Repair and Painting Works Painting of Street light Poles of height more than 7 m and upto 9 m with one coat of primer and two coats of approved alumminium paint after scrubbing and cleaning the old paint complete from the existng surface.
Sub Head - II : Repair and Painting Works Painting of checkered plate/ Earth pit cover with two coat of black enamel paint after scrubbing and cleaning the old paint complete from the existng surface.
Sub Head - II : Repair and Painting Works Lettering of maximum 2" size (Alpha/ Numerical) on the existing surface of feeder pillar / panel/ earth pits with synthetic enamel paint of approved colour as approved by engineer-in-charge etc. as required.
Sub Head - II : Repair and Painting Works Lifting and lowering of Underground Submersible Pump Motor set upto 5 HP installed at various locations at airport colony.
Sub Head - III : Supply of Material (As and when required ) Supply of Spring charging motor with gearbox suitable for L&T make U-Power FP ACB of rating 800A/1000A/1250A/2500A.
Sub Head - III : Supply of Material (As and when required ) Supply of box type heavy duty capacitor of following rating suitable to work on 3 phase, 440 V, 50 Hz AC supply.
Sub Head - III : Supply of Material (As and when required ) Supply of Shunt release coil for L&T make U-Power FP ACB of raring 1250/ 2500 A.
Sub Head - III : Supply of Material (As and when required ) Supply of heavy duty SMF battery of following rating :-
12V, 100 AH. Exide XP or equivalent
12V, 180 AH. Exide XP or equivalent
Sub Head - III : Supply of Material (As and when required ) Supply of Single Core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cables, 1100 Volts Conforming to IS: 694.
Sub Head - III : Supply of Material (As and when required ) Supply of Safety shutter for 4P U-power ACBs of 2500A rating.
Sub Head - III : Supply of Material (As and when required ) Supply of medium intensity obstruction light as per latest ICAO specification
Sub Head - III : Supply of Material (As and when required ) Supply of transformer oil.as per latest government specifications for power transformer.
Sub Head - III : Supply of Material (As and when required ) Supply of syubmersible pump of 3 hp make KSB model UMAI or equivalent
Sub Head - III : Supply of Material (As and when required ) Supply of submersible pump of 5 HP make KSB model UMAI or equivalent
Sub Head - III : Supply of Material (As and when required ) Supply of table solar fan minimum 16 w, upto 1300 rpm, fan diameter minimum 35.00 cm at all Security booths situated along the perimeter road
Sub Head - III : Supply of Material (As and when required ) Supply of wall mounted 300 mm sweep fan suitable to work on single phase, 230V, 50 Hz AC supply.
Sub Head - III : Supply of Material (As and when required ) Supply of heavy duty exhaust fan of following size having 1400 RPM suitable to work on single phase, 230V, 50 Hz AC supply :-
Sub Head - III : Supply of Material (As and when required ) Supply of 400 mm sweep pedestrail fan suitable to work on single phase, 230V, 50 Hz AC supply.
Sub Head - III : Supply of Material (As and when required ) Procurement of Street Lights of 70W.
(i) Strip
(ii) Driver
Sub Head - III : Supply of Material (As and when required ) Supply of Legrand Myrius 673044 6A 5 Pin White Universal Sockets with safety Shuter
Sub Head - III : Supply of Material (As and when required ) Supply of 6A/16A, Uni Socket.
Sub Head - III : Supply of Material (As and when required ) Supply of 6A/13A Combine Socket (For All Kind Of Pins).
Sub Head - III : Supply of Material (As and when required ) Supply of white 1M Modular Combined Plate.
Sub Head - III : Supply of Material (As and when required ) Supply of white 2M Modular Combined Plate.
Sub Head - III : Supply of Material (As and when required ) Supply of white 3M Modular Combined Plate.
Sub Head - III : Supply of Material (As and when required ) Supply of 6A, Bell Push Switch.
Sub Head - III : Supply of Material (As and when required ) Supply of 20 W, tube fittings suitable to operate on single phase, 230V, 50 Hz AC supply.
Sub Head - IV DSR Works Percentage above or below on the rates of DSR'2018 (CPWD)-Electrical items worth totaling to Rs.5,00,000.00 as per requirement. (Note: The firm has to quote/upload the Percentage above/ below (+/- %) on the quantity mentioned against this item directly in the form of multiplying factor in the rate coloumn as clarified below: For Example: If desired to quote 5% above on SR-2018 rates, the rate column shall be filled as 1.05. If desired to quote 3% below on SR-2018 rates, the rate column shall be filled as 0.97.)
M/S AMAR ENTERPRISES
M/S CHAUDHARY CONSTRUCTION
ABHISHEK INTEGRATIONS LIMITED
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .