| 1 | L1₹29.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹29.9 L+₹37,175 (1.26%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹30.9 L+₹1.4 L (4.57%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance L3 | |
| 4 | L4₹31.1 L+₹1.6 L (5.37%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L4 | Rejected-Finance L4 | |
| 5 | L5₹31.6 L+₹2.1 L (7.07%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
6 Jul 2020, 10:00 amClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF 2 x TOILETS FOR JCOs/OR AT BLDG NO P-63, P-64 AND SPL REPAIRS TO DRAINS OF TECH AREA (APPROX 250 MR) OF 204 INCLUDING CERTAIN REVENUE WORKS AT DINJAN UNDER GE DINJAN
2020_MES_348946_1
C/8943/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹54,000
8 Aug 2020
1 Jun 2020
7 Jul 2020
1 Jun 2020
6 Jul 2020
16 Jun 2020
Amount
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and as directed.
Excavation in post holes each not exceeding 0.50Cum and getting out in soft/loose soil including returning, filling in and ramming earth etc. and removing surplus soil to a distance not exceeding 50m and making good surface complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth, for foundation, etc. or for shafts, wells, cesspits, manholes, etc. not exceeding 10Sqm on plan and not exceeding 1.5m in depth and getting out soft/losse soil complete all as specified and as directed.
Returning, filling in, inluding spreeding, levelling, watering and well ramming in layers not exceeding 25cm thick in soft /loose soil complete all as specified and as directed.
Removing excavated surplus soil etc not exceeding 50m and depositing where directed at level n.exc 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for Brick work with sub class 'B' brick stright or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and as directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc laid beded and pointed in any mortar complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks laid on flat, in floors bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:6) complete all as specified and as directed.
M&L for bricks, sub class 'B' laid on edge in drain bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed.
M&L for flush pointing to brick walls in cement mortar (1:3) complete all as specified and as as directed
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc, complete all as specified and as directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
All as per item No. 14 here-in-before but 8mm dia and over.
All as per item No. 14 here-in-before but 8mm dia and over and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits ( if any) of foundation and plinth beams and similar vertical or to a batter flat rough finished surface complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stantions rough finished surface square, rectangular or polygonal complete all as specified and as directed.
M&L for form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to edges of concrete flates, treads break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exceeding 10cm not exceeding 20cm wide and sisides of RCC/PCC bands in walls, horizontal or sloping and similar work complete all as specified and as directed.
M&L for reinforced cement concrete type B-1 (1:2:4) (using 20mm graeded stone aggregate) as in foundation, including rafts, footings foundation beams, plinth beams, bases of columns etc, basement slab, underreamed piles and mass concrete complete all as specified and as directed.
M&L for reinforced cement concrete type B-1 (1:2:4) (using 20mm graeded stone aggregate) as in columns, pillars piers, posts and struts complete all as specified and as directed.
M&L for reinforced cement concrete type B-1 (1:2:4) (using 20mm graeded stone aggregate) as in beam, cantilever, bressummers, lintel over 1.5 mtr span concrete flat complete all as specified and as directed.
M&L for reinforced cement concrete type B-1 (1:2:4) (using 20mm graeded stone aggregate) as in roof slabs supported on walls surfaces of concrete flat complete all as specified and as directed.
M&L for hard core of gauge not exceeding 63mm deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface using broken stone/boulders complete all as specified and as directed.
M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
M&L for 40mm thick PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) laid in panel finished even and smooth with using extra cement as in flooring complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surface in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surface in cement mortar (1:4) finished complete all as specified and as directed.
M&L for 5mm thick rendering on concrete surface of ceiling in cement mortar (1:3) finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces complete all as specified and as directed.
M&L for two coats of cement base paint on newely plaster surfaces of walls including preparation of surfaces complete all as specified and as directed.
M&L for applying three coats of white wash on wall surfaces including preparation of surfaces complete all as specified and ascdirected.
S&F for steel ventilator with top hung shutter including hinges steel peg stay complete all as specified and as directed.
S&F for galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed complete all as specified and as directed.
S&F for 3mm thick sheet glass, ordinary quality and glazing with oil putty not exceeding 0.5Sqm each pane complete all as specified and as directed.
M&L for framed work such as grills grating etc with ends of bars shoulderd and/or riveted welded or forged into spikes framedguard bars iron doors, ladders framed, balusters, walk ways railings, frame work of of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F for rotational moulded polyethylene water storage tank consisting of three layer cylindrical vertical with top closed hoisted and fixed in position of capacity 1000litres complete all as specified and as directed.
S&F for 20mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F for 20mm dia ball valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F for bib taps 15mm bore standard of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 90gms) complete all as specified and directed.
S&F for 15mm bore galvanised iron tubing medium grade with all fillings and fixtures fixed to wall ceiling or laid in floors etc. complete all as specified and as directed.
S&F for 20mm bore galvanised iron tubing medium grade with all fillings and fixtures fixed to wall ceiling or laid in floors etc. complete all as specified and as directed.
S&F for 25mm bore galvanised iron tubing medium grade with all fillings and fixtures fixed to wall ceiling or laid in floors etc. complete all as specified and as directed.
S&F for 15mm bore stop valve of PTMT any colour high prssure screwed for iron pipe and fixed (minimum weight 90gms) complete all as specified and as directed.
S&F for 15mm bore angle stop valve of PTMT any colour high prssure screwed for iron pipe and fixed (minimum weight 90gms) complete all as specified and as directed.
S&F for PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and as directed.
S&F for 75 mm dia PVC (SWR) floor trap plain with greting incl jointing with solvent cement complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
S&F for 110 mm PVC (SWR) bend any radius complete all as specified and as directed.
S&F for 110mm bore.PVC (SWR) junction single (single T) equal or unequal with access door complete all as specified and as directed.
S&F for vitreous china squatting pan "orissa" pattern size 580mmx440mm white with integral foot rests including 10ltrs capacity PVC flushing cistern low levl with inlet, ball valve float chain and pull and brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia for low level cistern complete all as specified and as directed.
S&F in repairs vitreous china semi pedestal pattern (anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC 1:4:8 type D-2 to match with existing complete all as specified and as directed.
S&F for 10 litres PVC valveless syphonic action type flushing cistern low level white, with inlet ball valve, float and handle including bracket with 32 mm dia PVC pipe 600mm long complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm (300x300x7mm) over 15mm thick screed bed in cement mortar (1:6) on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match and 20mm thick screed bed in cement mortar (1:6) complete all as specified and as directed.
M&L for non skid coloured tiles 7 to 8mm thick (Square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 Sqm, in skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match and 10mm thick rendering in cement mortar (1:4) complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350X450X7mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as dado/skirting and facea of side building over and including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
M&L for 20mm thick granite stone slab machine cut, over 15mm thick (1:4) cement mortar screed bed or bedding and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed.
M&L for machine pressed precast conctete interlocking paver block any shape and any size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and no pigment with 75mm thick sand cusion layer complete all as specified and as directed.
M&L for 75mm thick plain cement concrete type C-2, 1:3:6 (using 40mm graded aggregate) as in sub base of flooring/hard standing etc complete all as specified and as directed.
M&L for chequered cement concrete tiles 25 cmx 25cmx20mm thick set and jointed and pointed with grey cement and pig ments in neat cement slurry in floors including 15mm thick secreed bed or bedding in cement mortarin (1:4) set and jointed and pointed in neat cement slurry complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6, type C-2 (using 40mm graded stone aggregate) laid in panels surface finish even and smooth without using extra cement as in plinth protection complete all as specified and as directed.
M&L for forming 12mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'B' for 100mm thick slab complete all as specified and as directed.
S&F in repairs vitreous china urinal flat back white of size 465x355x265mm with grating union discharge pipe etc. complete all as specified and as directed.
S&F in repairs wash hand basin, vitreous China white, flat back of size 350x400mm including brackets complete all as specified and as directed.
S&F pillar tap cast copper alloy with captain heads chromium plated screwed down high pressure with or without (Hot or Cold) with long screwed shanks and fly nuts screwed for iron pipe 15mm bore complete all as specified and as directed.
S&F for solid PVC door frame of size 50x47 mm made out of 5mm PVC sheet reinforced with MS square tube as per specification drying as per manufacture instructions including all necessary fitting complete all as specified and as directed.
S&F for 30 mm thick factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top and bottom rails . MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail , and bottom rail ,Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading , and jointed together with solvent cement, complete all as specified including locking device and all necessary fitting etc here and after complete all as specified and as directed.
S&F for 200mm long aluminium anodised barrel barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F for 100mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed.
S&F for 125mm aluminium handles cast type, anodised complete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc comprising with the following operation and as specified here-in-below:- (a) M&L for screed bed and bedding layer of Mortar 20mm thick in CM 1: 4 for roof slab mixed with water proofing compound (to be measured and paid separately) as per manufactures instruction finished even and plain complete. (b) Cutting out cracks to V-section in existing roofs or terracing, cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand 1:1 (by weight) (c) Preparing & cleaning of fully dried cement concrete surface. (d) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (e) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (f) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm.
Drilling and tapping cast iron water mains (position) for branch connections of the internal dia of 25mm bore galvanised iron pipe complete all as specified and as directed.
M&L for precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded aggregate) as in cover slab of manholes, septic tank etc. set in cement mortar (1:4) including necessary form work, moulds etc and including taking out/removal of existing unserviceable cover slab form manholes/septictank complete all as specified and as directed. (Note :- Reinforcement shall be measured and paid separately).
M&L for two coat of synthetic enamel paint over a coat of red oxide zinc chrome surfaces of any description over 10cm in width or girth not other wise described including preparation of surfaces complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of red oxide surfaces of any description not exceeding 10cm in width or girth when unconnected with other painting or when painted in a different tint including preparation of surfaces complete all as specified and as directed.
M&L for roof truses (framed), trussed, purlins, crane gantries, rails and fasternings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pices, cleats etc.Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for preparation of new or previously untreated surfaces of steel or iron surfaces exceeding 10cm width or girth and applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F for pre-painted galvalume aluminium zinc coating galvanised iron based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for pre-painted galvalume aluminum zinc coating galvanised iron based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Cleaning of block drain pipe (SGSW/hume pipe) upto 150mm dia by rodding from manholes and well flushing with water after cleaning the same all as required and including disposing off the deposited sludge , etc inside pipes to a distance exceeding 50m and not exceeding 200m burried under ground (minimum 30cm below ground level) including necessary excavating of pits in soft/ioose soil and returning filling in including sprinkling of bleaching powder @ 0.20Kg/Sqm and dressing of surplus soil around slope all complete as required and as directed.
Cleaning of manholes including taking out accumulated semi liquid, sludge and other deposits such as broken bricks, silt etc from manholes of depth not exceeding 1.5m, cleaning as directed and removing the same to a distance not exceeding 50m and burried under ground (minimum 30cm below ground level) including necessary excavation of pits in soft/loose soil and returning, filling in including, sprinkling of bleaching powder @ 0.20Kg/Sqm and dressing of surplus soil around to slopel complete as specified and as directed.
M&L for plain cement concrete (1:3:6) type C-2 bed to 150mm bore drain pipes including packing under hunching against the sides of pipes after they are laid and tested complete as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.
S&F for reinforced concrete pipes 450mm Dia, Class NP-2, laid and jointed with collers complete all as specified and as directed.
Demolition of cement concrete (un reinforced) of any description and in any position not other wise specifically provided complete all as specified and as directed.
M&L for cement concrete type B-1, 1:2:4 (using 20mm graded aggregate) copings, kneelers, apex stones, bed plates, kerbs not provided, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
Supply only 50 micron polythene sheet black for flooring complete all as specified and as directed.
Dismantling asbestos cement (corrugated, semi corrugated etc.) sheets in roof coverings including ridge complete all as specified and as directed.
M&L for 6mm thick asbestos cement sheet, corrugated, or semi corrugated sheets in roofs, walls, etc. and fixed with L type or J-type or cranked hook bolts complete all as specified and as directed.
M&L for asbestos cement two piece adjustable serrated ridge for corrugated or semi corrugated sheet, fixed with L type or J type hook or cranked hook bolt with washer complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mmx600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mmx25mmx1.4mm thick for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of galvanised iron flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4mm thick non asbestor E-board, HSPC fixed to frame complete all as specified and as directed.
M&L for preparing new ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in foundation for post, struts etc completed all as specified and as directed.
S&F for mild steel angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc flat iron fillets ( for securing wire mesh etc) including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed.
S&F for mild steel screw bolts 5 to 10mm diameter of shank screw bolts (machine made) with hexagonal screw heads at one end & screwed the other or screwed both ends, each screwed endsto be fitted with washers & one hexagonal or square nuts, small end exe 5cm and not exc 10cm long complete all as specified and as directed.
Supply only Chain link mild steel galvanised fencing, any size or type Supply only Chain link fencing 4.0 mm mm dia galvanized wire (100x100) mm mesh made upto matress lapped wire and laid on position / fixed on poles complete all as specified and as directed.
Fixing only chain link fencing incl line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc incl provision of binding wire complete all as specified and as directed.
S&F for galvanized 2 strand sheet barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and straning and fixing to any type of standard rails strasing bolts complete all as specified and as directed.
S&F mild steel round bars 10 mm dia conforming to Fe-410-0 or Fe-310-0 fixed independently including hooking ends for fixing chain link fencing as in bearing bars complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets light fitting etc for taking credit removing from site and making good disturbed surface of walls, floors etc complete all as specified and as directed.
M&L for concealed point wiring with 1.5 sq mm (nominal area) single core pvc insulated FR unsheathed multi-standared copper conductor cable (maintaining colour code) , 1100 volt grade and including pvc conduitct (size as required site) concealed and sunken terminal boxes with 3 mm hylam sheet top cover of adequate size for mounting switches, sockets, regulators light fitting etc complete with all fitting and accessories fixed to wall /ceiling for one light /fan/call bell point concealed by one switch including one run 1.5 sq mm (nominal area) PVC insulated frame retardant unsheathed multistranded copper conductor cable green in colour for earth continuity conductor connected to common earth point duly completed all as specified and as directed.
M&L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size through and including PVC casing & caping terminated in PVC Box for fixing of switches, sockets, fan regulators etc for one light point or one fan point or bell point controlled by one switch complete all as specified and as directed.
All as per item No. 112 here-in-above but for one 3 pin socket outlet, 5 Amp independent.
All as per item No. 112 here-in-above but for one 3 pin socket outlet, 5 Amp on the same board with other switches.
M&L for point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 2.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 2.5 sqmm size through and including PVC casing & caping terminated in PVC Box for fixing of switches/ sockets for one 3 pin socket outlet, 15 Amps, independent complete all as specified and as directed.
S&F for switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed.
S&F for ceiling rose, 3 way PVC insulated body complete all as specified and as directed.
M&L for lamp holder, PVC/ poly carbonate type with black plate suitable for batten fittings complete all as specified and as directed.
S&F for socket outlet 2 in 1, 3 pin, 5 Amp,240 V complete all as specified and as directed.
S&F for switch socket combination 2 in 1, 5 Amp flush type, 240 V complete all as specified and as directed.
S&F Switch socket combination 5A/ 16A, 5 in 1flush type,240V complete all as specified and as directed.
S&F for stepped type (five steps), 230 V electronic fan regulator flush type (Socket Type) complete all as specified and as directed.
S&F for LED Lamp 7 Watt complete all as specified and as directed. Make : Havells/Philips/Bajaj.
S&F for exhaust fans AC single phase 230/ 240 V of size 380 mm sweep 1 phase 1400 RPM including LOUVER SHUTTER of suitable size complete all as specified and as directed. Make : Crompton/Philips/Bajaj.
S&F for sheet metal enclosure for MCB DB double door single pole and neutral 4 way, 240 volts with common bus bar at incomming end complete all as specified and as directed.
S&F in repairs sheet metal enclosure for MCB DB double door single pole and neutral 8 way, 240 volts with common bus bar at incomming end complete all as specified and as directed.
S&F for MCB 'C' curve single pole and neutral 6 to 32 Amps with breaking capacity 10 kA complete all as specified and as directed. Make : Legrand, Cat No. 408609-17
S&F for MCB 'C' series single pole 6 to 32 Amps, 240 volts, breaking capacity 10KA, complete all as specified and as directed. Make : Cat No. 4086 09-17 of Legrand/L&T/Havells.
S&F for 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection's suspended by insulating hangers not more than 1 mtr apart including 4mm suspention wire, one twin core cable slat or circular 10.0 sq mm solid conductor complete all as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering and the pit base in which pit cover rests to be made up of MS angle iron frame complete all as specified and as directed and tested on completion.
S&F for recess mounted deep drawn CRCA housing with higher power LED 34 watts seamless front frame with flat white hight transmission acrylic cover complete all as specified and as directed. Make : Cat No. PLUTONEO2X2PLR34WLED84OS of Havells/ Philips/Bajaj/CG/ Wipro.
S&F 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 including fixing arrangements clamps/nut bolts/pipe for holding the building security lights complete all as specified and as directed. Make : Cat No. ENDURAPEARLSL25WLED757SASYTOPC of Havells Philips/Bajaj/ CG/Wipro.
M&L for sub main wiring with two runs of 6 sqmm (Nominal area) single core FRLSH cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits/casing-caping of suitable size, fixed to wall/ceiling etc including 6 sqmm (nominal area) single core, FRLSH PVC insulated, multistranded, unsheathed, FRLSH copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed. (Note : PVC Conduits/Casing-caping, two run wiring cables and one run of earth wire will be measured as one length.)
M/s GANDHESWAR PHUKAN
STANDARD ELECTRIC WINDERS
Bimal Trading Company
NChetia and Sons Trading
Kaushik Enterprises
FREEZCON
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .