Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹50.0 L+₹12.1 L (31.9%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
9 Nov 2023, 6:00 pmClosed
Garrison Engineer
Garrison Engineer Chandimandir panchkula Haryana 134107
GE/CHM-62/2023-2024 SPECIAL REPAIR TO MULTIPURPOSE HALL AND PROVN OF GUARD REST ROOM UNDER AGE B/R II AT CHANDIMANDIR
2023_MES_622941_1
GE/CHM-62/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Chandimandir
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer
₹96,000
Yes
3 Feb 2024
12 Oct 2023
11 Nov 2023
12 Oct 2023
9 Nov 2023
26 Oct 2023
Amount
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges, all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors laid, bedded and pointed in any mortar including disposal of demolished material n.exc 1.5 km complete all as specified and directed.
Dismantling boarding any description fixed in any position with nails complete all as specified & directed.
Taking down cement plaster from brick walls or concrete surfaces including raking out joints, hacking out for key, scrubbing down with water complete all as specified and directed and removing rubbish etc. complete all as specified and directed.
Brick work with sub class ‘B’ bricks of old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:6 complete all as specified & directed.
Brick work with fly ash brick old size bricks, straight or curved on plan exc 6 metre mean radius built in cement mortar 1:4 complete all as specified & directed.
Brick work with fly ash brick old size bricks, straight or curved on plan exc 6 metre mean radius built, half brick thick walls built in cement mortar 1:4, complete all as specified & directed.
Material and labour plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, hold fast, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straigth or curved) complete all as specified & directed by Engineer-in-charge. - (i) The unit rate include for use of form work (straight or curved). (ii) Reinforcement if any shall be measured and paid separately.
15mm thick rendering cement plaster in Cement and Sand mortar 1:4 over concrete /brick surfaces finished even and fair complete all as specified & directed.
Rendering 15mm thick in Cement and Sand mortar 1:6 over brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
Material and labour Rendering 15mm thick on fair faces of brick work or concrete surfaces, finished even and fair in cement mortar (1:4), inclunding using water proofing compound complete all as specified. Note : WPC shall be measured and paid separately.
Rendering 10mm thick in CM 1:3 on fair faces of concrete/brick surfaces as in ceiling, chajja, facia or similar positions , finished fair and smooth complete all as specified and directed.
Preparation of new surfaces of any description of wall and applying two coats of exterior emulsion paint of approved tint over a coat of exterior wall primer, upto four storey bldg complete all as specified and directed.
Preparation of old surfaces of any description of walls,facia, ceiling, RCC etc and applying two coats of oil bound distemper over one coat of wall primer complete all as specified and directed.
Two coats of exterior emulsion paint on existing external plastered or unplastered surface of building over one coat of exterior wall primer (all as per manufactures instructions) including complete removal of existing treatment complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer, over and including 2mm thick (average) wall care putty and sand papering, complete all as specified & directed by Engineer-in-charge.
Preparation of new plastered surfaces of walls and applying two coats of cement base paint , complete all as specified and directed.
Three coats of white wash on ceiling surfaces including preparation of new plastered surfaces complete all as specified and directed
Rolled mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to grade Fe.290.Gde-E-165, fixed as in repair complete all as specified.
Pre-painted galvalume aluminium zinc coating (AZ 70) GI based corrugated steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed by Engineer-in-charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge, hips , valley gutters, drip and straight flashing (length and girth as fixed), fixed with self tapping screws complete all as specified & directed by Engineer-in-charge.
Preparation of new or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide, zinc chrome complete all as specified and directed.
One coat of synthetic enameled paint on old steel surfaces of any description ,including preparation of old surfaces , complete all as specified & directed.
Kota Stone Slab flooring, 20-25mm thick, best quality for staircase landing , treads steps, etc laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 10mm screed layer in cement mortar 1:4, cutting, rubbing, grinding and polishing upto granite finish, complete all as specified.
All as per serial item No 26 herein before but in skirting, riser of staircases etc over and including 10mm thick rendering in cement mortar 1:4
Providing and fixing false ceiling at any heights with GRG (Glass fibre reinforced Gypsum) false ceiling tiles of size 595 x 595mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99% NRCO 0.5 to 0.75 as per IS 8225:1987, Noncombustible as per BS 479(part-4) 1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 Gms as per Sqm including both sides) comprising of main T runners of size 15 x 32mm of length 3000mm, cross T of size 15 x 32mm of length 1200mm and secondary intermediate cross T of size 15 x 32mm of length 600mm to form grid module of size 600x 600mm suspended from ceiling using galvanized mild steel item ( galvanizing @ 80 grams per sqm) i.e. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1100 mm length and L-shaped adjuster of size 85 x 25x 2mm. Galvanised iron perimeter wall angle of size 24 x 24x0.4mm of length 3000mm to be fixed on periphery wall /partition with the help of plastic rawl plug at 450mm centre ot centre and 40mm long dry wall wood screws. The work shall be carried out as per specification, drawings and as per directions of the Engineer-in-Charge.
10mm thick square edged fully perorated GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 x 595mm complete all as specified and directed
Framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 complete all as specified & directed by Engineer-in-charge.
Preparation of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Granite stone slabs, 18 to 20mm thick, width and length as per site requirement, best quality machine cut and polished to be fixed in floors,cooking plateform, tread, raiser of steps and vertical surfaces etc and jointed with gray cement slurry and pointed in white cement mixed with marble dust (1:2) with admixture of pigment to match the shade of slab, rubbing, cutting / rounding of edges and corners where required with and including 15 mm thick screed bed in cement mortar 1:4, Complete all as specified and directed.
Demolition of plain cement concrete in ground floor and paving n.exc 15cm thickness below or above ground level complete all as specified and directed.
75mm thick plain cement concrete type C-1 1:3:6 (Using 20mm graded crushed stone aggregates) as in plinth protection finished fair and even without using extra cement complete all as specified and directed.
Hard core of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and leveled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed.
Dismantling floor hearth or wall tilling including cement mortar bedding, complete as specified and directed.
Non skid, first quality ceramic coloured tiles, 7 to 8 mm thick (square/ rectangular) area or each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile, over and including 15mm thick rendering in cement mortar 1:6 complete all as specified and directed.
Glazed ceramic coloured tiles of size 350mmx450mmx7mm on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
15 mm bore Galvanized Steel tubes, medium grade including all fittings for flush pipes, water supply pipes etc., fixed to walls and ceilings or laid in floors , including taking up or down existing GI tubing and removal to store complete all as specified and directed.
Steel water tubes, 15mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors, complete all as specified and directed.
Steel water tubes, 20mm dia bore, medium grade, galvanized, with all standard fittings and fixed complete to walls (surface/ concealed), ceiling or laid in floors, complete all as specified and directed.
Cutting chases, pinning in making good to facings where required and pointing in cement mortar (1:3) or PCC (1:2:4) type B-0 using 12.5mm graded crushed stone aggregate to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10cm girth, and removal of rubbish outside MoD land, complete all as specified and directed.
Vitreous china, wash down water closet pan, Pedestal pattern coloured with ‘P’ or ‘S’ trap in and, including seat cover, complete set, fixed as in repair complete all as specified and directed.
Vitreous china, wash down water closet pan, Pedestal pattern coloured with ‘P’ or ‘S’ trap in and, including seat cover, complete set, complete all as specified and directed.
Plastic water closet seat cover white closed pattern with flat bottom mild steel chromium plated or aluminium hinging device, fixed as in repairs, complete all as specified and directed.
Hand jet chromium plated (health faucet with 01 m PVC pipe) for 15mm bore with fittings, fixed as in repairs ,complete all as specified and directed.
Hand jet chromium plated (health faucet with 01 m PVC pipe) for 15mm bore with fittings, complete all as specified and directed.
PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia PVC long bend for squat pattern WC , set with concrete and making good to floor, fixed as in repair complete all as specified & directed.
PVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection with PTMT nuts and 32mm dia PVC long bend for squat pattern WC , set with concrete and making good to floor, complete all as specified & directed.
Wash hand basin, vitreous china, flat back , white , of size 550X400mm with angle brackets, waste coupling fixed as in repairs, complete all as specified and directed.
Central hole Basin Mixer, with popup waste system with 450mm long copper pipes and brass nuts, cast copper alloy, chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair, complete all as specified and directed.
Central hole Basin Mixer, with popup waste system with 450mm long copper pipes and brass nuts, cast copper alloy, chromium plated, screwed for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
Angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type , screwed both ends for iron pipe or for unions, suitable for 15mm bore pipe, fixed as in repairs, complete all as specified and directed
Angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type , screwed both ends for iron pipe or for unions, suitable for 15mm bore pipe, complete all as specified and directed
Bib taps brass, fancy type, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, fixed in repair complete all as specified and directed.
Bib taps brass, fancy type, with wall flange, chromium plated, cast copper alloy, screwed down for iron pipe or for brass ferrule, suitable for 15mm bore pipe, complete all as specified and directed.
Vitreous china squatting pan, “Orissa” pattern size 580mm x 440mm white, with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, set with cement concrete, complete all as specified & directed.
Vitreous China urinals, half stall type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) fixed as in repair, complete all as specified & directed.
Cast iron 'P' or 'S' trap, ISI marked, suitable for 100 mm bore CI spun pipes complete all as specified.
PVC (SWR) rain water pipe, 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
PVC (SWR) waste pipe, 75mm bore, single socketed in any length with cement/ rubber ring joints, laid in trenches or in floor or fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed.
75 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
Stop valve, cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
Stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 20mm bore pipe, complete all as specified and directed.
Stop valve (concealed type), chromium plated, fancy type, screwed down, high pressure with crutch or butterfly handle, screwed both and for iron pipe or for union, suitable for 15mm bore pipe, complete all as specified and directed.
PVC (SWR) floor trap 100mm bore, plain with grating incl jointing with solvent cement, complete all as specified and directed.
Brass, chromium plated, tubular towel rail 20 mm dia. ‘D’ type, 60 cm long between flanges including brackets complete all as specified and directed.
Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; chains; hand made sliding bolts; clamps; hold fasts; wall ties; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles confirming to Fe-410-O or Fe-310-O complete all as specified.
32mm dia waste coupling / waste fitting of PTMT any colour high-pressure screwed for iron pipe and fixed (minimum weight 45 gms), complete all as specified and directed.
Soap dish of cast copper alloy, chromium plated (CP), complete all as specified and directed.
Peg hook set of 6 of aluminum body,complete all as specified and directed.
Vitreous china table top basin (Premium Quality), size 600mm x 400mm x 175mm, complete all as specified and directed .
200mm aluminum anodized barrel tower bolts of extruded section, complete all as specified.
150mm size aluminium handle (ISI Marked), cast type, anodised complete all as specified & directed by Engineer-in-charge.
Aluminium alloy, anodized, sliding door bolts with hasp staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium, 300 mm long and dia of rod not less than 16 mm, ISI marked, complete all as specified.
100mm size, butt hinges, medium weight, cold rolled mild steel including necessary welding if required all as specified & directed by Engineer-in-charge.
Butt hinges 100mm long, of extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 , all as directed.
Floor door stopper of aluminum alloy body and tongue, anodized with hard drawn steel spring, fixed in floor (140mm size), complete all as specified and directed.
PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 20 cm deep and getting out in hard/dense soil, complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in soft and loose soil all as specified & directed by Engineer-in-Charge.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc.25cm thick each layer of soil all as specified.
Removal excavated soil to a distance exc 250 but n.exc 500m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
Sand filling under floors or in foundation, including watering and consolidation, all as specifed.
Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, sub base and mass concrete complete all as specified & directed.
100mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base etc, finished even and rough complete all as specified and directed.
Reinforced cement concrete (M-25 design mix, using crushed stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, bases for columns etc., basement slabs, under-reamed piles and mass concrete and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Reinforced cement concrete (M-25 , using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, balconies, roofs, canopies shelves , chajja, lintel and the like complete all as specified and directed (reinforcement shall be measured and paid for separately).
Mild steel high strength deformed TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips complete all as specified and directed.
All as per serial item No 91 herein before but 8 mm dia -ditto-
All as per serial item No 91 herein before but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders, -ditto-
Form Work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter to give rough finish to flat surfaces complete all as specified and directed.
Form work to soffits of suspended slabs such as roof slabs, beams, balconies, roofs, canopies shelves , chajja, lintel rough finished surface of concrete flat not exc 200mm thick complete all as specified and directed.
Steel window, box type, primer coated, 1.00mm wall thickness, with glazing bar and openable shutter prepared to recieve sheet glass, complete including cutting holes, four Nos. for each window and making good dismantled portion in PCC (1:2:4) type B-1. including following fittings welded to frame/ shutter:- (a) Hold fast 150mm out of 25x6mm flat iron made to shape- 04 Nos. each window (02Nos. on each side). (b) Handle of 'Z' section 20mmx25mm, 100mm long- 01No. each leaf. (c) MS tower bolt 150mm long- 02 Nos. each leaf. (d) 'Z' section 20mmx25mm, 100mm long stopper 01 No. each leaf. (e) Cleat 55mm long of hollow square section 15mmx15mm of 24 guage wall thickness, welded to hinge of 55mm size 01 No. per leaf. (f) MS box type hinges of 75 mm size- 03Nos. per leaf. (g) Fabrication & fixing complete. Note: Glass panes & painting shall be measured & paid separately under respective item.s. Design shall be approved from Engr-in-Charge as existing at site and all as per Drawing before fabrication and bulk order to the manufacturer.
All as per serial item No 96 hereinbefore but without glazing bar.
Factory made box type steel ventilators, openable with top hung shutters with box type hinges including one shop coat of red oxide primer, hinges, tower bolts 100 mm, steel handles and steel peg stay complete without glazing bars devetailed or welded, complete all as specified and directed.
4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square exc 0.5 Sqm in each panes complete all as specified and directed.
4mm thick figured glass pin head type ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes complete all as specified and directed.
Galvanised mild steel wire cloth 0.56 mm nominal dia of wire & avg width of aperture 1.18 mm in fixed with tinned tacks complete all as specified and directed.
Rendering 20mm thick (average thickness) plaster in cement mortar 1:4 mixed with WPC on concrete roof/ wall surfaces including flashings and junction of parapets etc, finishing the surface even and fair without using extra cement all as specified and directed by Engineer-in-charge. Note :- WPC will be measured & paid separately as supply only).
3mm thick Atactic polypropylene polymer (APP) based polymeric membrane minimum weighing 3.6kg/sqm and reinforced with polyester non woven fabric (weight not less than 150 gm/sqm) laid over a coat of bitumen primer @0.40L/Sqm by same membrane manufacturer of density 0.87 to 0.89 kg/L at 25° C temperature and viscosity 70 to 160 CPS, over primer coat bonding material of blown bitumen 85/25 grade heated to working temperature of 180° C applied @1.2Kg/Sqm. The membrane shall be laid using butane torch and sealing all joints etc after preparing the surface as per standard practice and as per manufacturer instructions and finished with applying one coat of bituminous aluminium paint @100gm/sqm on top of membrane, complete all as specified & directed.
1000 litres capacity rotational moulded polyethylene water storage tanks (Cylindrical vertical with closed top) double layered, screwable lid, hoisted and fixed in position, including tank nipple, PTMT 20mm dia ball valve, complete all as specified in SSR Part-I and all as directed by Engineer-in-charge.
Solid PVC frame having profile 105mm x 60mm , single rebate, made out of solid PVC foam with homogenous fine cellular structure having density not less than750Kg/ cum, smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws , complete all as specified and directed. Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life.
Pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, including fill of PCC 1:3:6 complete all as specified and directed.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC “C” channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing mentioned on Srl Page No. 134, 135 and 146 of SSR Part-II including aluminum iron mongery.
35 mm thick, factory made, second class hard wood, plain framed hammer marked, panelled shutter (two panel)with lock rail and panel of 9 mm BWP commercial ply both face including 1.00 mm thick sunmica (lamination) on both sides of p-anel and 20 mm x 20 mm x 10 mm wooden beading all round the panel. The size of rail and stile as per IS : 1003 (Part I) kiln seasoned and chemically pressure treated complete all as specified and directed.
Glazed and gauged skelton shutter (Factory made) 35mm thick of second class hard wood open rebated & prepared to receive glass, gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut & mitred beads for securing glass etc including priming coat. Size of members of shutters as specified in SSR Part I Section 8, clause 8.20 (a) including Kiln seasoned and chemically pressure treated,complete all as specified & directed.
Concrete interlocking pre polished paver block, with grey cement and pigment, design as approved, any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25mm thick sand cushioning complete all as specified and directed
Taking down carefully aluminum/copper point wiring on & including hard wood battens, surface conduit and board/blocks etc or through conduits for light , socket or power point ,fan point complete incl fitting such as switches ,sockets, ceiling rose , holder socket, light fitting, regulators and making good disturbed surfaces of wall, floor , ceiling etc and removing materials (other than those for which credit has been given by the contractor) to the MES stores yard for keeping in safe custody complete all as specified and directed.
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in existing conduit terminated on and including provn of new modular sunken box and suitable size of frame, cover for mounting switch, socket and regulator fixed on surface flush with wall , comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed.
All as per serial item 112 herein before but for socket outlet 3 pin 5 Amps on same board complete all as specified and directed
All as per serial item 112 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 112 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Point wiring with approved colour code multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade, two run of single core cable for phase & neutral and one run of single core multi stranded copper conductor, PVC insulated and unsheathed FRLSH cable of size 1.5 Sqmm ,1100 volts grade for earth continuity conductor to common earth and connected to earth dolly in and including new concealed PVC conduit terminated on and including new steel sunken boxes 1.2mm thickness covered with provision of 3mm thick plastic laminated sheet, comprising of One light /bell/buzzer point controlled by one switch or one fan point controlled by one switch &fan regulator, complete all as specified and directed. Note :Unit rate is inclusive of cutting chases in wall /foor/PCC and making good the disturbed surfaces to match the original finishes surface and nothing extra shall be paid on this account.
All as per serial item 116 herein before but for socket outlet 3 pin 6Amps on same board complete all as specified and directed
All as per serial item 116 herein before but for socket outlet 3 pin 6 Amps on independent board complete all as specified and directed
All as per serial item 116 herein before but One socket outlet three pin ,6/16 Amp, independent board, with 2.5 Sqmm (nominal area ) FRLSH cable & 2.5 Sqmm (nominal area ) cable as earth continuity conductor
Switch modular type (ISI marked), single pole, one way 6 Amps, one module (ISI marked), complete all as specified & directed.
Switch modular type (ISI marked), single pole, one way 16 Amps, one module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2/3 pin 6 Amp modular type multi purpose combined two module (ISI marked), complete all as specified & directed.
Socket shutters outlet 2 in 1 pin 6/16 Amp modular type multi purpose combined 2 module (ISI marked), complete all as specified & directed.
Modular switch type stepped fan regulator, single pole, 230 volt two module complete all as specified and directed.
Modular switch type bell push, single pole, 230 volt one module,(ISI marked) complete all as specified and directed.
Switch piano, flush type, 6 amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Switch piano, flush type, 16 Amps, 230 volts, single pole, one way (ISI marked) complete all as directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 6 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Sockets outlet multipurpose 2 in 1 pin, 6 and 16 Amps flush type ISI marked all as specified and directed by Engineer-in-charge
Stepped type electronic fan regulator flush type complete all as specfied and directed.
Electric Bell, AC, 230 volts, ding dong, single pole all as specified and directed by Engineer-in-charge.
Ceiling rose, PVC or polycarbonate of size 65mmx50mm three terminals (ISI marked) all as specified and directed by Engineer-in-charge.
Lamp holder, PVC/Polycarbonate type with back plate angular type fixed on wall suitable for batten fitting ,complete all as specified and directed.
LED lamp 9 watts, B-22 type complete all as specified .
LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size fixed as in repair complete all as specified and directed.
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
LED lights fitting 1x 10W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose fixed as in repair complete all as specified and directed.
Surface mounted 1x 4 backlit panel 36 Watt LED fullglow having whtie powder coated CRCA body with high quality PMMA diffuser, fixed as in repair complete all as specified and directed.
Taking down carefully old copper or aluminium sub main wiring of any Nos of wiring and size with earth wire on wooden batten/ surface conduit/ casing- capping complete with its all accessories and making good disturbed surfaces of wall , floors etc complete all as specified and directed.
Sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 4 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 4 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed.
Supply and fixing sub main wiring with two single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note for serial item No 141 & 142 : (i) For the purpose of measurement, 3 runs ( Phase, neutral and earth) of single core 10 sqmm cable shall be considered as 1 running metre. (ii) cutting chases and PVC conduit will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Supply and fixing sub main wiring with four single core FRLSH PVC insulated and unsheathed cable with copper conductor of size 10 Sqmm (nominal area), 1100 Volt grade(with approved colour coding as per IS) with and including continuous earth wire of size 10 Sqmm PVC insulated and unsheathed FRLSH multi stranded copper conductor 1100 volts grade , and connected to main board drawing through PVC concealed conduit 25mm size(minimum size), cutting chases in walls for PVC concealed conduit and making good the disturbed surfaces by provding by wall putty/POP after mason work and finshing to match the original surfaces and nothing extra shall be paid on this account all as specified and directed. Note for serial item No 143 : (i) For the purpose of measurement, 5 runs ( Phase, neutral and earth) of single core 10 sqmm cable shall be considered as 1 running metre. (ii) cutting chases and PVC conduit will be measured and paid separtely (iii) colour code shall be Red for phase, Black for neutral and green for earth
Disconnecting the power supply and taking down carefully by unscrewing from boards fittings and fixtures such as DBs, Junction Box, Panels of any size complete with all MCCB's ,MCB's etc and removing from site, Complete all as specified and directed .
Vertical TPN distribution board double door flush mounting with provisions for MCCBs incomer upto 100 to 125Amps & outgoing 4 way having IP 54 protection Complete all as specified and directed .
MCCB, 125 Amps, four pole, 3 phase , 16KA, 415 volt with adjustable thermal and maganetic release, with proper thimble complete all as specified and directed
MCB distribution board, double door, flush mounting with provision for MCBs TPN 4 way, 415volt having IP 43 protection complete all as specified & directed.
MCB TPN 40 to 100 Amp, 415 volts having breaking capacity 16 KA 'C' series complete all as specified and directed.
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 8 way SPN, 240V completed all as specified and directed.
MCB DB, IP 43 protection, powder coated double door with locking arrangement suitable for surface and flush mounting, 12 way SPN, 240V completed all as specified and directed.
Sheet metal enclosure for DB, flush mounted single door suitable for 2 way SPN without busbar 240V completed all as specified and directed.
MCB, DP , 240 volt, 32Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB, DP , 240 volt, 40 to 63Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP , 240 volt, 6Amps to 32Amps, 10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SP , 240 volt, 63Amps,10 KA , 'B' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
MCB ,SPN, 240 volt, 40Amps,10 KA , 'C' series including connection with suitable size aluminium / copper lugs complete all as specified and directed
20 to 25 mm dia, rigid non metallic PVC concealed conduit, 'ISI marked', inclusive of all fittings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing accessories such as couplers lock nuts, saddless, pipe hooks etc for wiring, fixed as in repair Complete all as specified and directed .
Cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good, cutting not exceeding 10cm girth Complete all as specified and directed .
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, burried directly in ground vertically to a depth not less than 2.25m below normal ground level, with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to main switch board and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI light grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of presast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Sch Part-I (2009), complete including dismantling of old earthing, all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) unit rate including protection pipe and GI wire 4.00mm dia from top to earth plate upto 7.5 meter
LED focus light 20 watts cool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
LED pannel Recess mounted -2'x2' - 36 watts cool day light fitting with heat exchanger unit, LED driver, surge protection complete including cutting hole of required size in POP/false ceiling making good disturbed including taking down any type ceiling fitting, fixed as in repair complee all as specified and directed.
GI bracket made of GI pipe medium grade of 40mm dia, 1.5 mtr long, bend to shape of 120 degre ,fixed on pole/wall with clamp of size 50x6 of suitable length fixed with nuts/ bolts and 1.5 sqmm 2 core, 1.5 metre long flexible wire from connector / ceiling rose to light fitting complete all as specified and directed.
LED secuirty light 35 watt LED with lens and water/ weather proof powder coated high pressure dia cast housing with IP-66 built- in control driver, aluminium reflector, heat resistant toughened clear glass, connector block, surge protection with 35 watt LED lamp fixed on ceiling/pole/wall/ with fixing arrangement fixed with nuts bolts and 1.5 sqmm 3 core flexible wire from ceiling rose to light fitting ,complete all as specified and directed .
Supply and laying 40mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS 14930 Pt II with Anti Rodent and non flame propagating properties of approved color with fitting for cable protection complete all as specified and directed.
XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm, 2 core, all as specified and directed.
Ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1400 mm sweep. Min air delivery 245 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as speicified and directed
Electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre (Vertical type), BEE 5 Star rated, 30 volts AC single phase with and including heavy duty fastner not less than 100mm with suitable size of nut & washer grouted in wall complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
Heavy duty metalic body exhaust fan 300mm sweep, 240 volt, 50 Hz, with louvers heavy duty, single phase including making connection with suitable size twin core cable complete all as specified and directed.
Standard Const. Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .