REPAIR AND MAINTENANCE OF LIGHTENING CONDUCTORS EARTHING INFRASTRUCTURE AND OTHER CONNECTING ITEMS UNDER GE NAGROTA
2025_MES_710133_1
CANO GEN-25/2025-2026
Open Tender
Electrical and Maintenance Works
Item Rate
NAGROTA
Class D category b i
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹80,000
Yes
31 Jul 2025
26 May 2025
3 Jul 2025
26 May 2025
26 Jun 2025
9 Jun 2025
Amount
SCHEDULE A PART-I M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 32x6 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore medium grade for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/Transformer as specified and testing on completion for desired result complete all as specified and directed
M&L in replacement for earthing complete with copper earth plate electrode of size 60cm x 60cm x 3.15mm thick burried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above Copper plate in alternate layers connected to copper strip 20x3 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore medium grade for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ Transformer as specified and testing on completion for desired result complete all as specified and directed
M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth strip 25X4 mm by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 5 of MES SSR Part-I (2009) as specified including provision of 40mm bore medium grade GI pipe for earth strip protection and 20 mm bore medium grade for watering complete , all excavation and earth work & connecting the earthing to an earthing test point /LT Panel as specified and testing on completion for desired result complete all as specified and directed
M&L in replacement for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level surrounded on all sides by 150 mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to galvanized earth lead wire 4mm (8SWG) by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm bore medium grade GI pipe for earth strip protection and 20 mm bore medium grade for watering complete all excavation and earth work & connecting the earthing to an earthing test point /LT Panel/ DB box as specified and testing on completion for desired result complete all as specified and directed
Supply and fixing in replacement aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fix in replacement of GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified and directed.
Supply and fix in replacement of GI strip of size 32 x 6 mm for earth continuity conductor or main earthing lead fixed to wall burried in ground fixed alongwith poles complete all as specified.
Supply and fixing in replacement GI earthing continuty conductor wire of 4mm dia with saddles/ insulators and fixing screws for roof/ down conductors/ earth lead including brazing and nut bolts jointing at all joints for building/ hangar (roof/down conductor)/ pipe/ trench complete all as specified and directed.
M&L for recharging of earthing pits by filling of Water soluble earth soil reactivation earthing compund in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/ poured in earth pit after mixing in water in appropriate quantity.
S&F in repairs 12 mm dia and 300 mm long air termination, single pointed aluminium rod complete all as specified and directed.
M&L for dismantling of PCC earth pit chamber and making new PCC earth pit chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC 1:2:4 type B1 with precast RCC 1:2:4 type B1 cover slab 54cm x 54cm x 5cm reinforce with 8mm dia TMT bars @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel including excavation and earth work as required at site in any type of soil complete all as specified and directed.
Taking down & Refixing existing Aluminium strip of any size from building,Store house, Bunkers with porcelain insulator and tightly fix around the building complete all as specified and directed. Note : Necessary Saddles and Nails required for fixing the strip on wall shall be deemed including in items rate.
Supply and fixing in replacement of saddle/insulator for earth strip with fixing arrangement in roof/ wall conductors of building/ hangar complete all as specified and directed.
M&L for recharging of earthing pits by filling of common salt in earthing pits complete all as specified and directed. Note:- Recharging materials shall be soluble in water and to be filled/ poured in earth pit after mixing in water in appropriate quantity.
M & L for servicing of 5/10 Ton capacity flame proof EOT crane of any make installed at different building/location at site, making the cranes in serviceable condition complete all as specified and directed with and including opeartions for maintenance specified as under:- (A) LONG TRAVERSE MOTION- (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all LT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any.
Notes : (i) Servicing of EOT Crane shall be carried out through authorized service agency of Original Equipment Manufacturer (OEM). The contractor shall submit documentary proof/evidence in this regard before taking EOT Cranes under servcing etc. (ii) Make and model of part to be replaced shall be same as used/recommended by OEM. (iii) Servicing of unserviceable main components catered for separately under respective items of this Schedule shall be measured & paid for separately. (iv) Load as required for testing shall be arranged by the user/department. However, transportation of load for testing from the place of issue and return to the place of issue shall be responsibility of the contractor. (v) Contractor shall give a certificate after servicing of EOT Crane that Crane is serviceable & fully functional in all respect and ready to use for load.
(C) HOIST MOTION (a) Checking gear box oil level, checking and rectifiaction of leakage if any and filling with new oil up to required level. (b) Checking functioning of all brakes of any capacity and making adjustment for proper working. (c) Checking motion wheel for any abnormal sound & checking mounting/ fixing arrangement. (d) Checking of grease in geared coupling and tighting of nut/bolts etc. (e) Checking of motion cut off at extreme ends with limit switches. (f) Checking drive shaft and coupling including tighting of nut and bolts. (g) Checking oil in FLP thrustors checking any leakage any filling with new oil. (h) Checking terminal connection of all hT motion of three phase FLP electric motor and tightening properly including repalcing burnt out/ over heated cable ends if any. (D) ELECTRICALS (a) Checking and tightening all electric connection (b) Checking the contactors/ relays etc for overheating or flashinng. © Clening off all connection and control cables. (d) Properly bunching the loose control cable. (e) Checking functioning of cable carriers. (f) Checking the connection and serviceability of VVVF drives for smooth working. (E) GROUND MOTION CONTROL PANEL Opening the push button control unit, checking all connection, replacing flashed/ over heated connections, general cleaning and checking all the functions,of the LT/CT/ Hoist motion push buttons and lights/ VVVF switch including reassembling the unit complete
Notes : (i) Servcing of EOT Crane shall be carried out through authorized service agency of Original Equipment Manufacturer (OEM). The contractor shall submit documentary proof/evidence in this regard before taking EOT Cranes under repair, overhauling, etc. (ii) Make and model of part to be replaced shall be same as used/recommended by OEM. (iii) Servcing of unserviceable main components catered for separately under respective items of this Schedule shall be measured & paid for separately. (iv) Load as required for testing shall be arranged by the user/department. However, transportation of load for testing from the place of issue and return to the place of issue shall be responsibility of the contractor. (v) Contractor shall give a certificate after servicing of EOT Crane that Crane is serviceable & fully functional in all respect and ready to use for load.
Supply only gear oil grade 680 suitable for hydraulic thruster brake complete all as directed.
Supply only Grease of required type/class for lubrication as specified and directed.
Supply only Ball bearing of size 6310 suitable for 10 Ton capacity gear box for main hoist complete all as specified and directed.
Supply only Ball bearing of size 6317 suitable for 10 Ton capacity gear box for main hoist complete all as specified and directed.
Supply only Ball bearing of size 6206 suitable for 10 Ton / 2 Ton capacity EOT crane for CT complete all as specified and directed.
Supply only Ball bearing of size 6212 suitable for 10 Ton / 2 Ton capacity EOT crane for Long Travel complete all as specified and directed.
Supply only Ball bearing of size 6210T suitable for 10 Ton / 2 Ton capacity EOT crane for Long Travel complete all as specified and directed.
Supply and fix Solar PV Modules of Crystalline Silicon Terrestrial PV Modules : IEC 61215 / IS14286 with Thin Film Terrestrial PV Modules : IEC 61646 with Concentrator PV Modules & Assemblies : IEC 62108 In addition, the modules must conform to IEC 61730 Part 1-requirements for construction & Part 2 - requirements for testing, for safety qualification or Equivalent IS. The PV modules must conform to the latest edition of any of the following IEC / equivalent BIS. Silicon Poly Crystalline SPV cells shall be used in the Solar Photovoltaic module. The General requirements for PV module: (i) Module shall be made up of mono or poly crystalline silicon cells. (ii) The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions (iii) The minimum clearance between the lower edge of the modules and the developed ground level shall be 300 mm. (iv) Surge arresting device to be provided at junction box, if provided,and module shall be provided with bypass diode. (v) The bidder shall carefully design & accommodate requisite numbers of the modules in the available area (refer layout attached with the tender) to achieve the rated power in his bid. (vi) The SPV module must be IEC 61215 and IEC 61730 Part I and Part II certified from any of the accredited certifying agencies (vii) Each Solar PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years from the completion of the trial run.
M&L for Servicing and calibration of grid tied string type inverter of 50 KW installed at GE Nagrota with complete testing and servicing and make it fully functional complete all as specified and directed. Note : i) Serviving include the calibration and testing from OEM.
Supply and fix in reapir DC CABLES of 1 Core 4 mm² of Solar Grade, UV resistant made of Multistrand of Tinned Copper Conductor interconnecting between module to module and string to module complete all as specfied and directed.
Supply and fix in reapir AC cables from invertor to ACDB of size 35 sqmm 4 core, copper conductor, PVC insulated, FRLS, fixed with saddles to wall and laying in ducts complete all as specfied and directed.
M& L for Testing , Servcing & calibration of cloud based Monitoring System ( SCADA) by checking all the parameter current, Power, Voltage from the OEM. SCADA web operation shall be achieved thru Wi Fi/SIM based technology. Contractor has to provide SIM card for SCADA operation and maintain the connection for the entire period contract. complete all as specfied and directed.
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out complete all as specfied and directed.
Returning, filling in. including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specfied and directed.
Removing excavated surplus material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point. complete all as specfied and directed.
M&L for Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) complete all as specfied and directed.
M& L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat abutting each other complete all as specfied and directed.
All as per Srl item No 32 above but using old bricks retrieved from excavation
Supply and fix DWC pipe for cable protection with outer dia 50 mm and inner dia 38 mm including suitable size of coupler for connection of pipe complete all as specfied and directed. Note : Pipe shall be manufactured as per IS 16205 ( Part-24) have a smmoth internal surface and corrugated external surface for cable protection
Supply and fix DWC pipe for cable protection with outer dia 40 mm and inner dia 32 mm including suitable size of coupler for connection of pipe complete all as specfied and directed. Note : Pipe shall be manufactured as per IS 16205 ( Part-24) have a smmoth internal surface and corrugated external surface for cable protection
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 95 Sqmm 3.5 core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 70 Sqmm 3.5 core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 50 Sqmm 3.5 core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5 core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 25 Sqmm 4 core, complete all as specified and directed
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 16 Sqmm 4 core, complete all as specified and directed
S&F commissioning and testing of CPRI approved outdoor cubical type LT panel of size not less than 40 cm X 75 cm X 140cm , IP-54 Protection for outdoor shell and IP- 42 for inner shall,suitable for 415V, 3 phase, 4 wire 50Hz, AC supply system fabricated fromstainless steel totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell and 2mm thick for inner shell having MS section not less then 50x50x6 mm thick having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, painting with two coat of smoke grey synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed by Engrineer-in-Charge. Note:- LT panel shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM1:6 and two coates of cement base paint and the rates shall be inclusive in the quoted rate. (Minimum size: 1.5*2.5*4.5 in Feet )
Outgoing (a) MCCB 3 Pole, 100 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 04 Nos (b) On Load change over switch front operated suitable for 4 pole 415V of capacity 250 Amp
S&F commissioning and testing of CPRI approved outdoor cubical type LT panel of size not less than 40 cm X 75 cm X 140cm , IP-54 Protection for outdoor shell and IP- 42 for inner shall,suitable for 415V, 3 phase, 4 wire 50Hz, AC supply system fabricated fromstainless steel totally enclosed,Dust,Weather & vermin proof, 3.15 mm thick for outer shell and 2mm thick for inner shell having MS section not less then 50x50x6 mm thick having TPN aluminium busbar mounted in porcelin insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB, painting with two coat of smoke grey synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed Note:- LT panel shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM1:6 and two coates of cement base paint and the rates shall be inclusive in the quoted rate.
Outgoing (a) MCCB 3 Pole, 100 Amp, 20 KA, Adjustable Thermal & Fixed Magnetic setting , Ics = 100% of Icu- 04 Nos (b) On Load change over switch front operated suitable for 4 pole 415V of capacity 200 Amp
Supply and install HT Bus bar chamber, factory made, weather and vermin proof having size 90x90x60 cm made out of 3mm thick MS Sheet wih 200 Amp rated Alumiunm bus bar and with 11 KV pedestal type HT Insulators 6 No with angle iron frame of size 75x75x6mm duly painted with 2 coats of enameled paint & neccesary PCC work for foundation complete all as specified and directed
M & L for MS Framed work as in framed structure (around 4 pole/2 pole/ LT pannel/ Transformer) guard bars, framed balusters and similar works complete including PCC work as in foundation inclusive of 2 coat of synthatic enamel paint over & incl one coat of red oxide primer complete all as specified.
M & L for Expended metal cut to length, bend to required shape weight not less than 4 kg/Sqm and laying with and including annealed MS wire or welded to steel members complete all as specified.
M & L for heat shrink cable end joint suitable termination outdoor type for 3 core cable XLPE with aluminium conductor 11000 volt graded (earthed) of cross sectional area 50 to 95 sqmm complete. Kit with all accessories and jointing material and testing after jointing complete all as specified.
M & L for Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size not less than 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate. Note: The work under subject BoQ (item No. 1.00 to 49.00 ) are meant for maint of External Electric/ Earthing infra in Nagrota Mil Stn ( Including Katra, Sanjhi Chat, Charli Hill ). The work shall be executed on ground on required basis. Contractor shall deploy sufficient resources to keep smooth working of External Electric Supply at Station. Contractor or his representative will daily attend the complaints at E/M complaint cell and in addition any breakdown shall be communicated to contractor or his representative by concerned Engineer-in-charge/JE E/M through phone call, text message, complaint slip and or in writing through site order book or through other means. Non complying of attending breakdown by contractor within 24 hours after notify the complaint, recovery @ Rs 1500/- per day shall be recovered from contractor's payment for each complaint so notified.
Allied Technologies (BID ID -3323383)
R.K. Works (BID ID -3337787)
M/S VIRENDER SADHOTRA (BID ID -3338350)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .