| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L1 | Accepted-AOC L1 | |
| 2 | L2₹17.5 L+₹1.7 L (10.6%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | - | Rejected-Technical Not enlisted in c(i) category | |
| 4 | Rejected-Technical 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | - | Rejected-Technical Not enlisted in c(i) category |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
4 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KHUMBATHANG
GE KHUMBATHANG C/o 56 APO
GE/KHU-29 /2020-21 COMPREHENSIVE MAINTENANCE OF CHS AND ALLIED SERVICES AT KHUMBATHANG UNDER GE KHUMBATHANG
2020_MES_367602_1
GE/KHU-29/2020-21
Open Tender
Civil Works
Item Rate
270 days
KHUMBATHANG
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KHUMBATHANG
₹40,000
Yes
11 Jan 2021
8 Aug 2020
5 Sept 2020
8 Aug 2020
4 Sept 2020
21 Aug 2020
60 days
Amount
M&L for detection of leakage, rectification of leakage by means of water method, making the system leak proof and serviceable complete all as specified and directed.
M&L for removing / opening of electric boiler control panel for checking serviceable state of control wiring and switches which includes replacement of minor parts (control wiring and other necessary items for making the panel serviceable) complete all as specified and directed.
Dismantling of mono block electric motor set of capacity 3 HP and taken it to civil workshop for rewinding the motor with existing size of super enamelled copper wire including all necessary insulating material and refixing the moter set at the original position and testing it on full load upto the entire satisfactrion of EIC complete all as specified and directed. ( Note : Transportation charge of motor from site to workshop and back is deemed to be included in the item rate) .
M&L for rewinding of burnt winding of electric water pump and blower of upto 5 HP capacity complete all as specified and directed.
S&F in repair complete assay of 25000 K/cal Model AH-25 AHU unit of make alfa Therm or equivalent complete all as specified and directed.
Supply only glycol / coolent alongwith the necessary additives and inhibitor in cognition and supplied in barells complete all as specified and directed.
S&F Heater bank in repair of capacity 25 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed
S&F Heater bank in repair of capacity 7 KW for electric based central heating system all as specified and directed incl taking down old one complete all as specified and directed
S&F in repair Heater bank of capicity 5 KW for electric based heating incl thermostat of suitable capacity and other connected accessories incl taking down old one complete all as specified and directed
S&F in repair of monoblock of pump 1 HP with all accessories complete all as specified and directed.
S&F in repair Burner fuel pipes incl taking down old one complete all as specified and directed.
S&F in repair oil filter (super fine glass type) of suitable for burner 1 lac K/C as per requirement at site incl taking down old one complete all as specified and directed
Labour for complete Decarbonising of boilers including replacement of damaged refractory complete all as specified and directed
S&F in repair pressure switch incl taking down old one complete all as specified and directed.
Repair to body leakage of electric Hamam of capacity 45 Ltr ,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed.
S&F in repair flexible PVC all weather/ Crack proof pipe of size 20 mm dia complete all as specified and directed.
Repair to body leakage of electric Hamam of capacity 25 Ltr ,steel body rectangular/round type with thermostates and auto cut and change of burnt heating element complete all as specified and directed.
M&L for Replacement of damaged nitril insulation of 19 mm thick over PPR pipes of 32 mm size as required at site complete all as specified and directed.
M&L for Replacement of damaged abstract rope insulation of 10 mm thick over Duct (outside) of CHS 200x200 mm size as required at site complete all as specified and directed.
M&L for Replacement of damaged Chymney for 25000 K/cal Model AH-25 AHU unit of make alfa Therm length as required at site complete all as specified and directed.
M&L for Replacement of damaged aluminium caldding over any pipe as required at site complete all as specified and directed.
Labour only for opening the Oil based boiler, dismentaling the accessories and cleaning the boiler including replacement of necessary minor accesries as per site requirement complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 500 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 300 ltr Deep Freezer complete all as specified and directed.
S&F in replacement of reciprocating/rotary compressor including refilling of refrigirent R-134a, brazing and bring to be serviceable condition and testing suitable for 200 ltr Deep Freezer complete all as specified and directed.
S&F contactor A-26-30-10, 13 NO in repair AC 3 phase complete all as specified and directed. Make - Crompton greaver/ L & T/ BCH/ABB
S&F contactor MNX 9, in repair AC 3phase complete all as specified and directed. Make : L &T /ABB/Schnider
Material & Labour for Descaling of radiator panel associated with CHS installed at signal and A Mess complete all as specified and directed.
Labour for servicing of fan coil unit of indoor units, removing dust / other remains with suitable liquid complete all as specified and directed.
S&F in replacement of wall mounted fan coil unit of capacity 1.5 TR (4500 K Cal/Hrs 600 Cfm) complete all as specified and directed.
S&F in replacement of wall mounted fan coil unit of capacity 1.0 TR (3000 K Cal/Hrs 600 Cfm) complete all as specified and directed.
S&F in replacement of Sequence control of boiler complete all as specified and directed.
S&F in replacement of iginition transformer of boiler complete all as specified and directed.
S&F in replacement of Nozzle 60 degree 2GPH of boiler complete all as specified and directed.
S&F in replacement of ignition Electrode complete all as specified and directed.
M&L for replacement of Fuel pump suitable for 1 lac kilo calories burner assembly complete all as specified and directed.
Supply, installation, testing and commissioning of wall mounted type hecco panel of size 600mm x 300mm x 18mm or rating of 65W each, complete, all as specified and directed incl taking down old one. Make of Panel : Ecco, Menos or equivalent
S&F Heat Pillar Rod of capacity 750 Watts complete all as specified and directed.
S&F in replacement of heating element AC 230 volt, triangle/round type of rating 1500 watt suitable for geyser/Hamam as per sample, complete all as specified and directed.
Supply only heating element AC 230 volt, triangle/round type of rating 2000 watt suitable for geyser/Hamam as per sample ,complete all as specified and directed.
M&L for repair of Water heater storage type, electric based ,capacity 50 litres rates including change of thermostate, stainless steel tank, heating element complete all as specified and directed by Engr-in-Charge.
S&F in replacement PVC insulated stranded copper conductor size 2.5 Sqmm 2 core for connection anti freezing tracer complete all as specified and directed.
M&L for repair of Water heater storage type, electric based ,capacity 25 litres rates including change of thermostate, stainless steel tank, heating element complete all as specified and directed by Engr-in-Charge.
S & F in repair of motor of FCU1.5 TR/1.0 TR complete all as speciifed and directed.
Repair of metal heat pillar of capacity 2x750 KW including necessary wire connection complete all as specified and directed.
S&F in repair single phase earth metal plug socket incl 32 A MCB C series complete all as specified and directed.
M & L for change of submain wiring 2 core 4.0 sqmm phase and neutral incl earth wire of 2.5 sqmm in existing conduit and PVC batten complete all as speciifed and directed.Note: 2 runs of 4.0 sqmm phase and neutral and 01 core of 2.5 sqmm as earth wire will be treated as one unit.
S & F in replacement of existing UNSV MCCB 4P 100 A 25 KA with thermal and magnetic release including providing suitable thimble complete all as speciifed and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 63 KW electric boiler complete all as specified and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 45 KW electric boiler complete all as specified and directed.
S&F in repair step up control system for 6 step including metre,control board and control wiring suitable for 75 KW electric boiler complete all as specified and directed.
Supply & Fixing in repair Ball valve of 20 mm dia complete all as specified
M&L for replacement of damaged relay 16 Amps MN-2 Complete all as specified
Dedcuct Credit for Demolished/Dismantled material Rs (-) 89060.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
SUMEET TRADING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .