Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.2 L+₹1.5 L (6.51%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹24.4 L+₹1.8 L (7.76%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹27.9 L+₹5.2 L (23.1%)Rejected-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Jul 2021, 6:00 pmClosed
GE AF Yelahanka
GE AF Yelahanka
MISC PETTY DAY TO DAY REPAIRS TO EXISTING LIGHT FITTINGS, ELECTRIC WIRING SWITCHES, SOCKETS FITTINGS AND FIXTURES IN OMQ AND SMQ AT AFS YELAHANKA.
2021_MES_452539_1
8888/E8
Open Tender
Civil Works
Item Rate
330 days
AFS Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE AF Yelahanka
₹70,000
Yes
24 Sept 2021
18 Jun 2021
3 Jul 2021
18 Jun 2021
1 Jul 2021
19 Jun 2021
Amount
Disconnecting and taking down the ceiling fan 1200/1400mm sweep carefully and dismantling blades and removing fan complete, servicing by cleaning and greasing the bearing/bush and replacement of split pin, replacing unserviceable items like bearing, bushes, rubber real, condenser, flexible cable, canopy, etc., assembling, refixing after complete servicing in the original place, connection and testing complete all as specified and as directed by the Engr-in-Charge. Note:- Replacement of unserviceable items will be measured and paid seperately under relevant items. Cost for replacement of minor items that are not included seperately in this schedule may also be included under this item.
All same as per item No 1 here-in-before but exhaust fan 280/300/450 mm sweep
All same as per item No 1 here-in-before but wall mounted fan 300/400/630 mm sweep
Supply and fix ball bearing for 1200/1400mm sweep. Make :- TATA/ SKF/NBC
Supply and fix ball bearing for Exhaust fan 280/300 /450 mm sweep Make;- TATA / SKF/NBC
Supply and fix ball bearing of suitable size for wall mounted fan of 300/400/630 mm sweep. Make:-SKF/TATA
Supply only gun metal bushes for 1200/1400mm sweep ceiling fan
Supply only condenser 2.5/3.5Mfd for ceiling fan
Supply only of canopy for 1200/1400 mm Sweep ceiling fan
Supply only rubber reel suitable for 1200/1400/1500mmsweep ceiling fan
Supply only blades suitable for 1200/1400/1500mm sweep ceiling fan set of 3 blades.
Supply only blades suitable for Exhaust Fan of size 280/300/450 mm sweep
Supply only blades suitable for Wall mounted fan of size 300/400/630 mm sweep
Supply and replacement down rod for ceiling fan with 15mm dia GI pipe medium grade ,screwed and drilled with clamps rubber real ,nuts,bolts, and safety pin,etc including painting ,up to 3 mtrs height.
Checking of ceiling fan for split pin, check nuts rubber reel, nut bolts, wiring etc complete all as directed. NOTE :- Replacement of rubber reel, nuts bolts, wiring etc will be measured and paid under relevant items of the schedule separately. Replacement of split pin, check nuts are within the scope of work.
Supply and Fix in repair PVC insulated cable of size 1.5 Sqmm single core flexible copper, heavy duty, ISI marked, FRLS unsheathed cable 1100 Volts grade with multistranded copper conductor all as specified and directed by Engr-in-Charge.
All as per item No 16 here-in-before but size 2.5 sqmm
All as per item No 16 here-in-before but size 4 sqmm
All as per item No 16 here-in-before but size 6 sqmm
All as per item No 16 here-in-before but size 10 sqmm
Supplying and fixing 10 Sqmm, 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circularall for service conncection as specified and directed by Engr-in-charge.
Collecting the burnt ceiling fans including blades of any make from AGE E/M store yard/ site, bring to reputed work shop/in-situ, dismantling removing the burnt winding, rewinding of ceiling fan with super enameled copper conduct winding wire of same gauge, insulating, varnishing, baking, including replacing of wornout bearing/bush greasing assembling and transporting the same and fixing and testing at site all as specified and as directed by Engr-in-charge,
1200 mm Sweep
1400 mm Sweep
All as per item No 22 here-in-before but Wall mounted fan 300/ 400mm sweep
All as per item No 22 here-in-beforeb but Exhaust Fan of size 280/300 mm sweep
All as per item No 22 here-in-before but Exhaust Fan of size 450mm sweep
Taking down opening and inspection of storage type water heater of size 25/50ltrs capacity and discaling with dilute hydrochloric acid, checking for water tightness of the inner tank, cable continuity, thermostat most of setting at 70 degree C checking fusible plug, stop cock including replacement of indicator lamp, rubber PVC gasket washers reassembling and refixing at old place and replacing unserviceable bolts and nuts, cementing work including hydraulic pressure testing with hard operated hydraulic pump complete after repair including spray painting of one coat with DUCO paint of approved in after preparation of surface Note : (a) Replacement of unserviceable items like heating element, Indicator lamps, thermostat, stop cock, 3 core copper cable will be measured & paid separately. (b) Cost for repalcement of Glass wool and Hot cold pipe are included in the unit rate quoted.
Supply only heating element including rubber/PVC gasket of the following all as directed including rubber washer 1.5KW / 2 KW any type
Opening, removal, testing and repalcement and calibration of thermostat of the geyser including rubber gasket and setting temperature between 70 degree C to 80 degree C for capacity of 25/50 Ltrs.
Checking thermostat calibration only of the geyser 25/50 ltrs capacity and setting temperature between 60 degree to 70 degree complete all as directed.
Material and Labour for disconnecting from Electric and water mains and dismantling the unserviceable gyeser base assembly and replacing the new base assembly with rubber gasket for 25 Ltrs capacity of any make and refixing in original place including recoonecting of electric and water supply mains including testing complete all as speicifed and directed by Engr-in-charge.
All same as per item No 30 here-in-before but 50 Ltrs capacity
S&F Stop valves bore dia 15mm, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as speicified and directed by Engr-in-Charge.
M&L for Brazing of Storage Type water heater (Geyser) of any capacity and make to stop leakage and testing after completion upto the satisfaction of concerned JE/ Engr-in-Charge. Note :- Disconnecting and reconnecting of geyser (water and elctric ) is included in unit rate.
S&F in repair copper conductor cable PVC insulated, sheathed 3 core 4 sqmm size 1100 volts grade all as specified and as directed.
M&L for replacing of unserviceable of Geyser Indicator lamps set of 2 (one no Red, one no Green) of any type complete all as specified and directed by Engr-in-Charge.
Supply only Rubber Gasket for inner Tank 25/50 Ltrs capacity of existing type and make complete all as specified and directed by Engr-in-charge.
Supply only Air release valve for 25/50 Ltrs capacity of existing type and make complete all as specified and directed by Engr-In-charge.
Supply only Non Return Valve for 25/50 Ltrs capacity of existing type and make complete all as specified and directed by Engr-in-charge.
Supply only copper tank for 25 Ltrs capacity of existing type complete all as specified and directed by Engr-in-charge.
All same as per item No 39 here-in-before but capacity 50 Ltrs
Supply only Fusible lead nut/safety valve for safety pressure of existing type complete all as specified and directed by Engr-In-charge.
Supply only PVC connections 15 mm size with PTMT nuts of length 450 mm length (for hot and cold water inlet and outlet) complete all as specified and directed by Engr-In-charge.
All same as per item No 42 here-in-before but 0.9/1m length.
Supply and fix in repair electronic meters temper proof, LCD display with polycarbonate cover single phase, 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH. NOTE:- old/unservicable energy meters will be deposited to E/M store.
All as per item No 44 here-in-before but 3 Phase, 415 volt
M&L for glass wool packing required quantity for covering the 25 ltrs copper shell to avoid the heat conduction .
M&L for glass wool packing required quantity for covering the 50 ltrs copper shell to avoid the heat conduction .
Taking down unserviceable /rusted GI tubing of 15mm bore
Supply and fix GI Tubing of 15mm bore 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors with proper clamps all as specified and directed by Engr-in-Charge.
M&L for grouting 4 nos of M12 x 100mm bolt store/brick masonry wall with 1:4 CM suitable for hanging geysers.
Taking down unserviceable /rusted GI tubing of 15/20 mm bore covered with the aluminium cladding .
Supply and fix GI tubing of 15mm bore medium grade fixed on walls with proper clamps and refixing existing aluminium cladding to cover the GI tubing to avoid heat conduction.
Supply and fix GI tubing of 15mm bore medium grade fixed on walls with proper clamps including supply and wrapping glass wool and aluminium cladding to cover the GI tubing to avoid heat conduction.
Supply and fix GI tubing of 20mm bore medium grade fixed on walls with proper clamps and refixing existing aluminium cladding to cover the GI tubing to avoid heat conduction.
Supply and fix GI tubing of 20mm bore medium grade fixed on walls with proper clamps including supply and wrapping glass wool and aluminium cladding to cover the GI tubing to avoid heat conduction.
M& L for replacing the following capacity ceiling/exhaust fan condensors
Supply and fix metal louvers of suitable size for exhaust fan of the following sweep
450 mm sweep
300 mm sweep
230 mm sweep
Supply and fix in repair CFL Lamp 9/11/18 watts 2 Pin type
Supply and fixing in repair CFL 36 watt, 4 pin type.
Supply and fix in repair Ballast 9/11/18W copper wound for CFL (2 Pin) fittings.
Supply and fix in repair Pin type lampholder for CFL fittings of 9/11/18W watts ( 2 Pin)
Supply and fix in repair Lamp 15 Watt holder type
Supply and fix in repair LED out door driver 10 Watt for bollard type fitting.
Supply and fix in repair Switch piano, flush type single pole, one way 5 Amp including disconnecting, taking down old/unserviceable switchs complete all as specified and directed by Engr-in-charge.
Supply and fix in repair modular switch, one way, 6 Amp, 1 Module including disconnecting, taking down old/unserviceable switchs complete all as specified and directed by Engr-in-charge.
Supply and fix in repair modular switch 2 way 6 Amp, 1 module including disconnecting, taking down old/ unserviceable switch 2 way complete all as specified and directed by Egnr-in-Charge.
Supply and fix in repair Bell push, flush type, 5 Amp including disconnecting and taking down old/unserviceable bell push complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Modular Bell push, 6 Amp, 1 module including disconnecting and taking down old/unserviceable bell push complete all as specified and directed by Engr-in-charge.
Supply and fix in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings including disconnecting, taking down old/ unserviceable Lamp holders complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Ceiling rose, 3 terminals PVC/polycarbonate, isolated body including disconnecting, taking down old/unserviceable ceiling rose complete all as specified and directed by Egnr-in-Charge.
Supply and fix in repair switch socket combination 2 in 1, 5 Amp flush type including disconnecting, taking down old/ unserviceable switch socket combination 5 Amps complete all as specified and directed by Egnr-in-Charge.
Supply and fix in repair switch socket combination 3/5 pin 16 Amp, flush type including disconnecting, taking down old/unserviceable switch socket outlet combination 15 Amps complete all as specified and directed by Egnr-in-Charge.
Supply and fix in repair stepped type electronic fan regulator flush type as per site requirement (Switch/Socket type) on the existing phenolic laminated sheet etc. as reqd including disconnecting, taking down old/unserviceable fan regulatorcomplete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair modular step type fan regulator, 120 Watt, 2 module including disconnecting, taking down old/unserviceable fan regulatorcomplete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair switch flame proof rotary type with termination box in LM6, 16A, single pole 250 Volt including disconnecting, taking down old/unserviceable switch flame proof complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair 8" x 6" hylem sheet 3 mm thick ISI marked.
Supply and fix in repair 7" x 4" hylem sheet 3 mm thick ISI marked.
Supply and fix in repair 4" x 4" hylem sheet 3 mm thick ISI marked.
Supply and fix in repair 10" x 12" hylem sheet 3 mm thick ISI marked.
Supply and fix in repair gang box one way suitable for switch 5 Amps complete all as specified.
Supply and fix in repair gang box two way suitable for switch 5 Amps complete all as specified.
Supply and fix in repair modular socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair modular socket 6A/16A-2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair MODULAR WHITE COVER PLATE WITH FRAME, 1 module ISI marked including dismantling and taking down old unserviceable cover plate with frame all as specified and directed by Engr in charge.
All same as per item No 84 here-in-before but 2 module
All same as per item No 84 here-in-before but 3 module
All same as per item No 84 here-in-before but 4 module
All same as per item No 84 here-in-before but 6 module
All same as per item No 84 here-in-before but 8 module
All same as per item No 84 here-in-before but 12 module
All same as per item No 84 here-in-before but 16 module
Supply and fix in repair MODULAR METAL FLUSH BOX, 1/2 module ISI marked including flushing inside the wall and making good to the disturbed surfaces and also matching with the existing surface and dismantling, taking down old unserviceable/rusty metal flux box all as specified and directed by Engr in charge.Supply and fix MODULAR METAL FLUSH BOX Metal flush box 1/2 module ISI marked complete all as specified and as directed by Engr-in-charge.
All same as per item No 92 here-in-before but 3 module
All same as per item No 92 here-in-before but 4 module
All same as per item No 92 here-in-before but 6 module
All same as per item No 92 here-in-before but 8 module
All same as per item No 92 here-in-before but 12 module
All same as per item No 92 here-in-before but 16 module
Supply and fixing in repair Call Bell 230 Volts, single pole including disconnecting, taking down old/unserviceable Call Bell complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair MCB Triple pole and Neutral, 415 volts, 40 to 100 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Triple pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair MCB Triple pole and Neutral, 415 volts, 16 to 32 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Triple pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair MCB Single pole and Neutral, 230 volts, 32 Amps, 'C' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair MCB Single pole, 230 volts, 5 to 32 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Taking down unsv MCB Distribution board/Metal clad socket of any size/capacity/make
Supply and fix sheet metal enclosures for MCB distribution board 415 Volts Triple pole and neutral 4 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 8 way Double door with 200 Amps rated busbar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface complete all as specified and directed by Engr in charge.
Supply and fix metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps, 'C' Curve, 10 KA rupturing capacity complete all as specified and directed by Engr in charge.
Supply and fix of metal clad socket outlet with Triple pole and neutral enclosure with two pin and earth plug socket complete with one triple pole MCB 32 Amps 'C' Curve, 10 KA rupturing capacity complete all as specified and directed by Engr in charge.
Taking down old/unserviceable sub main any size/type complete all specified and directed.
M&L for sub-main wiring with two runs of 1.5 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 20mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 1.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 1.5 Sq mm and PVC conduct is measured as one Run or one Meter.
All same as per item No 111 here-in-before but in PVC casing caping
M&L for sub-main wiring with two runs of 2.5 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 20mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 2.5 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 2.5 Sq mm and PVC conduct is measured as one Run or one Meter.
All same as per item No 113 here-in-before but in PVC casing caping
M&L for sub-main wiring with two runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 4 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 4 Sq mm and PVC conduct is measured as one Run or one Meter.
All same as per item No 115 here-in-before but in PVC casing caping
M&L for sub-main wiring with two runs of 6 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 6 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit will be measured as one length. Three run of 6 Sq mm and PVC conduct is measured as one Run or one Meter.
All same as per item No 117 here-in-before but in PVC casing caping
M&L for sub-main wiring with four runs of 10 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with copper stranded conductor drawn through and including not less than 30mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 10 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: Four runs of 10 Sqmm copper cable, one run of 10 Sqmm copper cable for earth continuity and PVC conduit will be measured as one run or one meter.
All same as per item No 119 here-in-before but in PVC casing caping
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
M&L for point wiring complete with 1.5 sqmm (nominal cross sectional area) single core PVC insulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including non metallic rigid PVC white conduit not less than 20mm dia and conduit accessories concealed/fixed to wall/floors/ceiling etc and provision of PVC Insulated heavy duty ISI marked unsheathed copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlests, fan regulators including fixing PVC round block 8 cm dia and 4 cm in depth etc., for the following: -
One light point controlled by one 5 Amps switch
One ceiling fan/exhaust fan controlled by one 5 Amps switch
One socket 5 Amp on independent board.
One socket 5 Amp on same board with other switches
One bell/buzzer point controlled by one push button on the same board with other switches or independent.
All as per item No 122 above but wiring with 2.5 sq mm FRLS copper cable including earth continuty conductor with 2.5 sq mm FRLS copper cable for one 6 pin 15 Amps socket outlet on independent board controlled by 15 Amps switch.
Point wiring with 1.5 Sqmm (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed copper conductor FRLS cable in and including PVC casing - caping of suitable size medium grade ISI marked complete and sunk CI/pressed steel terminal switch boxes flush mounting type with new hylam sheet (white) top cover, including earth wire continuity of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) copper conductor connected to all fittings, sunken boxes and common earth and connected to earth dolly complete all as specified and directed for the following:-
One light point controlled by one 5 Amps switch
One ceiling fan/exhaust fan controlled by one 5 Amps switch
One 3 pin socket outlet, 5 Amps on the same board with other switches
One 3 pin socket outlet, 5 Amps, independent
One bell/ buzzer point controlled by one push button on the same board with other switches or independent.
All as per item No.125 above but wiring with 2.5 sq mm copper cable with 2.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out controlled by 15 Amps switch.
M&L for point wiring complete with 2 run of 4 sqmm (nominal cross sectional area) single core PVC insulated heavy duty ISI Marked FRLS unsheathed cable 1100 volts grade with multistranded copper conductor drawn through in and including non metallic rigid PVC white conduit not less than 25mm dia and conduit accessories concealed/fixed to wall/floors/ceiling etc and provision of PVC Insulated heavy duty ISI marked unsheathed copper conductor, 4 sqmm for earth continuity conductor and connected to common earth dolly for 20 Amps metal clad socket.
Taking down the unserviceable light fittings of any capacity/any type.
Supply and fix LED luminaire 600mmx600 mm, 36 watt, 220 V AC recessed/surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix round shape 12 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge..
Supply and fix round shape 18/15 watt 220 volts AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
S&F in repair LED light fitting 10 Watt Bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engr-in-Charge.
Supply and fix LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fix LED, Tube light fitting 12 Watt, 2 feet long, 6500K self blasted LED batten, extruded thermoplastic body with PC diffuser in square shape CRI>80, beam angle 120 degree, surface mounted high and two round block for mounting tubelight fittings all as specified and directed by Engr-in-Charge. Make Polycab Cat No: LD00103028 or its Techno commercially equivalent.
Supply and fix LED light fitting (mirror light) with high out put diffuser, 2 feet long, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size and two round block for mounting tubelight fittings including dismantling old unsv fitting complete all as specified and directed by Engr-in-Charge.
Supply and fix post top lantern LED type 20 Watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engr-in-Charge.
All as per item No 135 here-in-before but 40 Watt, 230 volts AC
S&F in repair driver suitable for 20/40 Watt LED post top lantern light fittings and testing complete including taking down the same all as specified and directed.
S&F in repair energy saving building security light LED street light fitting 20 Watt 230 V AC with PDC aluminium body & secondary optical lens for superior light ditstribution, efficacy not less than 110Lm/Watt outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge. Make: Polycab Cat No PCGLS T1 20 N1 or its Techno commercially equivalent.
S&F in repair building security light LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge.
S&F in repair INVERTED PYRAMID TRIPOD TYPE LED BOLLARD 10 Watts 230 V, with control driver with efficiency 90 %, Decorative post top for 360o with high output diffuser prewired including all accessories,including dismantling old unsv fittings and connecting up with twin core copper conductor with suitable size complete all as specified and directed by Engr-in-Charge. Make: CG Cat No- LBLSN-10-CDL or its Techno commercially equivalent.
Supply and fix in repair driver suitable for inverted pyramid tripod type LED Bollard 10 watt 230 Volt and testing complete including taking down the Same all as specified and directed.
S&F in repairs LED Lamp 20 Watts with suitable to replace 36/40 Watts FTL,high Efficiency PMMA diffuser soft glare free light complete and including provision of three core textile braided copper conductor flexible wire from ceiling rose to light fitting all as specified and directed by Engr-in-Charge. Make: Polycab Cat No LTU0101009 or its Techno commercially equivalent.
S&F in repair exhaust fan 300mm sweep, made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as specified and directed by Engr-in-Charge.
S&F in repair exhaust fan 250mm sweep made, of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding complete all as specified and directed by Engr-in-Charge.
S&F in repair Meter board made out enclosures are of 2.0 mm CRCA sheet powder coating for load bearing member & non load bearing member with aluminium busbar with colour coded heat shrinkable PVC sleeve and suport with current density 1/Sqmm, including all internal wiring will be done with PVC insulated copper of suitable size, space for single phase energy meter 5 Nos, including MCBs four pole 63 Amp - 01 No as incomer and MCBs SPN 32 Amp-05 Nos as a outgoings including taking old unserviceable meter board with connected items all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Note : (a) The bidder shall note that Two Electrician (Skilled) and Two Helper (Semi-skilled) shall be made available alongwith T & P at MES Complaint Cell, AFS Yelahanka throughout the contract period against the fixing of items covered under BOQ. The rate shall be deemed to be included, in this provision in the quoted rate and nothing extra shall be entertained by Govt on this account. (b) Please note that the contract shall run for the period of 11 (eleven) months irrespective of quantities provided in BOQ. (c) The bidder shall note that electrician and helper employed should have mobile phone with them for the easy communications with USER & JE EM through ONLINE COMPLAINT SYSTEM. (d) The bidder shall note that Electrician and helper employed should have there individual bicycle to attend the complaints. (e) Daily attendance register will be maintained by the bidder to take attendance of electricians and helpers and put up to concern JE/Engr-in-Charge atleast once in a week. (f) The electricians and helpers employed should be qualified/trained enough to undertake the necessary repairs as directed by JE/Engr-in-Charge .
chowdeshwariconstructionco
Thirumala Construction
RRK PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .