Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.3 LAccepted-Finance | ₹8.3 L | L-1 | Accepted-Finance FIRST LOWEST |
| 2 | L-2₹8.4 LAccepted-Finance C C ROAD UMA NAGAR DEORIA | DEORIA | DEORIA | UTTAR PRADESH | ₹8.4 L | L-2 | Accepted-Finance SECOND LOWEST |
| 3 | L-3₹8.6 LAccepted-Finance | ₹8.6 L | L-3 | Accepted-Finance THIRD LOWEST |
| Sl No | Description | Qty | Unit | M/S DURGA PD. THIOKEDAR L2 | Sri Ramanand enterprises L1 | SRD ENTERPRISES L3 |
|---|---|---|---|---|---|---|
| 1.00Loading, Unloading and safe carriage of following materials from Store Centre, Deoria to JE dump Store and JE dump store to work site with proper stacking:- | ||||||
| 1.01 | PCC Pole 8.5/11 meter long (Distance upto 20km) | 50 | Nos. | 700 ₹35,000 | 800 ₹40,000 | 500 ₹25,000 |
| 1.02 | PCC Pole 8.5/11 meter long (Distance above 20km) | 70 | Nos. | 1,200 ₹84,000 | 1,100 ₹77,000 | 650 ₹45,500 |
| 1.03 | ST Pole 11/9 meter long | 10 | Nos. | 800 ₹8,000 | 900 ₹9,000 | 700 ₹7,000 |
| 1.04 | ACSR Dog Conductor | 1 | Kms. | 2,000 ₹2,000 | 2,250 ₹2,250 | 3,000 ₹3,000 |
| 1.05 | ACSR Weasel Conductor | 2 | Kms. | 2,500 ₹5,000 | 2,250 ₹4,500 | 2,000 ₹4,000 |
| 1.06 | Aerial Bunch Cable | 1 | Kms. | 2,500 ₹2,500 | 2,250 ₹2,250 | 4,500 ₹4,500 |
| 1.07 | Disc insulator with fitting | 50 | Nos. | 150 ₹7,500 | 200 ₹10,000 | 10 ₹500 |
| 1.08 | Pin insulator with fitting | 100 | Nos. | 150 ₹15,000 | 200 ₹20,000 | 10 ₹1,000 |
| 1.09 | Stay with 5 Kg. wire with all fitting complete | 6 | Nos. | 200 ₹1,200 | 150 ₹900 | 10 ₹60 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹8,500
Closing Date
23 Mar 2026, 12:00 pmClosed
Superintending Engineer
Electricity Distribution Circle Deoria
Annual Maintenance and Repair Works for the Year 2026-27 under Electricity Distribution Division, Barhaj
2026_PVVNV_1121317_1
30/EDC(D)/2025-26
Open Tender
Electrical Works
Electricity Distribution Division Barhaj
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Superintending Engineer
₹8,500
28 Mar 2026
28 Feb 2026
23 Mar 2026
28 Feb 2026
23 Mar 2026
28 Feb 2026
Loading, Unloading and safe carriage of following materials from Store Centre, Deoria to JE dump Store and JE dump store to work site with proper stacking:-
PCC Pole 8.5/11 meter long (Distance upto 20km)
PCC Pole 8.5/11 meter long (Distance above 20km)
ST Pole 11/9 meter long
ACSR Dog Conductor
ACSR Weasel Conductor
Aerial Bunch Cable
Disc insulator with fitting
Pin insulator with fitting
Stay with 5 Kg. wire with all fitting complete
Other Line & S/S materials
The excavation of foundation pit size 750mmx450mm and having depth of 1/6th of the full length of the pole. Fabrication & errection of Pole with fixing of necessary clamps & accessories as per required. All required materials such as Holding clamp, LT clamp, F-bracket, LT shackle insulator, Nuts & Bolts off size etc will be provided by the contractor. Grouting of Pole in cc ratio 1:4:8 (cement, sand and 40 mm brick ballast), Grouting will be done in the block of size 450x450 mm x depth upto ground level and backfilling of pits with mud completely and leveling etc (Material provided by Contractor). In case of ST pole making plinth around Pole height 300 mm above ground level with top 100 mm is kept tapered so that no rain water gets accumulated on the top. All work will be done as per RESPO norms & relevent IS Specification.
PCC Pole 8.5/11 meter long
ST Pole 9/11 meter long
Erection & grouting of stay in cc ratio 1:4:8 of cement, sand and 40 mm stone ballast including cost of grouting material with nozelling and binding of stay wire (Complete work)
Laying, stringing, sagging, binding and jumpering of conductor for LT/ 11KV/ 33KV Line with providing and fixing of LT/ other clamps, LT shackle insulator, Nuts & Bolts off size by the contractor as per required. ACSR Dog/Weasel Conductor
Dismantling and again stringing, sagging, binding and jumpering of old existing conductor for LT/11KV/33KV Line after erection of pole, Providing and fixing of LT clamps/other clamps, Shackle insulator and nuts & bolts off size by the contractor as per site requirement. ACSR Dog/Weasel Conductor
Replacement of broken/damaged following material/fitting of 33 KV/ 11 KV Line complete in all respect (Material will be provided by Department).
11 KV Pin insulator with fitting
11 KV Disc insulator with fitting
Replacement of broken/damaged following material/fitting of 33 HT/LT Line complete in all respect which will be supplied by contractor.
LT Shackle Insulator
Holding Clamps
Dismantling of following Line materials and safe loading, unloading and carraige of dismantled from work site to departmental store.
ST Pole 11/9 meter long
ACSR Dog Conductor
ACSR Weasel Conductor
Aerial Bunch Cable
Other Line & S/S materials
Lopping & Chopping of tree branches and disposal of the same at suitable place for clearance of HT/LT line.
GST EXTRA APPLICABLE
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_2086349.xls
BOQ • 0.32 MB
formsemi.rar
Tender Documents • 0.04 MB
Download all tender documents and submit your bid