| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC TAILOR MARKET MAIN BAZAAR MANDI ADAMPUR 125052 | HISAR | HARYANA | 125052 | L1 | Accepted-AOC accepted | |
| 2 | L2₹12.6 L+₹99,434 (8.53%)Rejected-AOC DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-AOC rejected | |
| 3 | L3₹12.7 L+₹1.0 L (8.59%)Rejected-AOC FIRST FLOOR GEETA COMPLEX ROHTAK ROHTAK ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | L3 | Rejected-AOC rejected | |
| 4 | L4₹12.9 L+₹1.2 L (10.5%)Rejected-AOC 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | L4 | Rejected-AOC rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical rejected |
Tender Value
₹13.4 L
EMD Value
₹26,740
Closing Date
9 Jun 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Provision of 20 Zones Fire Alarm Panel, Heat Detectors and other allied accessories have been made in this estimate
2025_HRY_450283_1
20250E3E794C B930 4E84 8C39 24452D33DCA2667BAR
Open Tender
Electrical Works
Works
90 days
Meham
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹26,740
Yes
22 Jul 2025
2 Jun 2025
10 Jun 2025
2 Jun 2025
9 Jun 2025
2 Jun 2025
Amount
HSR Items
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
NS Items
SITC of Micro processor based 2 wire fault tolerant, networkable type Fire Alarm / Detection Control Panel (having nos. of loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 characters LCD unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80 LED Indicators. The Panel shall have 3 Serial Ports. The pane\l shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in –charge of work. Make: Bosch / Edwards EST3 / Honeywell Morley Zxe series
SITC of Intelligent Analog Addressable type Smoke Detector that combine Photo Electronic and fixed temp thermal with dual LED, hard addressable having rotary decade address switches, with mounting base complete as requried conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of engineer-in-charge of work. Make: - Honeywell / Edward / Bosch
SITC of Intelligent Analog Addressable type Rate of rise / fixed Heat Detector complete with dual LED, hard addressale having rotary decade address switches, with mounting base complete as required to BS5839 Standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of engineer-in-charges of work. Make: - Honeywell / Edwards / Bosch
SITC of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliant to EN 54 having Rotary Decade switches for addressing with Back Box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Honeywell / Edwards / Bosch
SITC of Addressable Loop Powered Sounder with Strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: - Honeywell / Edwards / Bosch
Supply, Installation, Testing and Commissioning of Analog Addressable type Active Repeater fire alarm panel with 5.7` TFT colour display having controls for reset, mute, Accept, Silence alarms and self test conforming to BS5839 standards and Duly approved by EN54 with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Honeywell Morley /Edward EST3
SITC of Glow Type EXIT Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink sulphate as bare chemical class 1 material PSPA fixed on 3mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make GLOLITE / PEARL / OMEX
SITC of minimum :1000 Mtr. Range Kheraj / National make SIRON` generator provided at the roof of the building with separate Power SITC, relay with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work.
Supply, Installation, Testing and Commissioning of Addressable Control Relay Module with flexible network structures with a maximum switching current of 1A @ 30V DC. shall be EN54/UL/VDS Certification Makes: Honeywell/Edward/Bosch
Supply, Installation, Testing and Commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Makes: Honeywell / Edward / Bosch
SITC of Addressable type Fault Isolator for isolating shorted, de-linked and loose circuits between two successive fault isolators with automatic resetting arrangement to be interconnecting to loop cable complete as required conforming to BS5839 standards and duly approved by EN54/UL/VDS/BSA) with all labour and material required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: - Honeywell / Edward / Bosch
Supply and erection of `Fire Extinguishers` duly hang on wall with necessary hook complete in all respect. Make: Safex / Minimax / Cease Fire ABC Dry Powder Extinguisher 6 Kg Cap
Supply and erection of `Fire Extinguishers` duly hang on wall with necessary hook complete in all respect. Make: Safex / Minimax / Cease Fire CO2 4.5 Kg Cap
Supply and erection of PVC unsheathed copper conductor cable two core 1100 volts grade in pipe of suitable size excluding cost and erection of pipe. Make: - Havells / Polycab / Finolex / Plaza Size 1.5 sq.mm
SITC of 6 KVA Online UPS with 30 Mints Battery backup to complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make: - Microtek / APC Libert / Luminous
Supply and Erection of 12 Volt 42 Ah SMF battery complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make: - Exide / Amaron / Luminous
Supply and Erection of 16 mm angle MS Stand of 55 Kg. weight of dimension 40 mm (L) x 50 mm (H) x10 mm (W) duly painted used to accommodate 16 Nos.12 Volt 42Ah SMF batteries complete in all respect upto the entire satisfaction of Engineer in charge of the work.
Supply, Installation, Testing and Commissioning of 22 U Rack for wall / Floor mounting of Equipment with drawer shelves and wiring channels to accommodate and including all connections and terminations as required fabricated from minimum 2 mm thick CRCA sheet including power coating after surface treatment complete as required complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make: - Valrack / Comrack / Hive Network / Rittel / D-Link
Supply, Installation, Testing and Commissioning of Ceiling Speaker max Power - 6 W, Rated power (PHC) - 6W (6-3-1.5), sound pressure level at rate power (at 1 kHz 1m) - 96dB/90 dB, Effective frequency range (-10 dB) - 200 - 15000 Hz, Opening angle (at 1 kHz/ 4 kHz, - 6 dB), In degrees - 150/70, rated voltage - 100 v complete as required complete in all respect upto the entire satisfaction of Engineer in charge of the work. Make : Bosch / Ayzo/ Honeywell
INDIAN SECURITY AND FIRE SAFETY (BID ID -1275036)
Arora Telecommunication (BID ID -1275595)
Hytek Turnkey Projects Pvt. Ltd. (BID ID -1275906)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .