| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹74.0 LAccepted-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | 1 | Accepted-AOC 1 | |
| 2 | 2₹77.6 L+₹3.6 L (4.83%)Rejected-AOC VPO KHARKHARI TEHSIL LOHARU DISTRICT BHIWANI HR | BHIWANI | HARYANA | 127021 | 2 | Rejected-AOC 2 | |
| 3 | 3₹89.9 L+₹15.9 L (21.4%)Rejected-AOC | 3 | Rejected-AOC 3 | |
| 4 | 4₹95.1 L+₹21.1 L (28.5%)Rejected-AOC | 4 | Rejected-AOC 4 |
Tender Value
₹64.4 L
EMD Value
₹1.3 L
Closing Date
10 Jun 2022, 3:00 pmClosed
EE PHED No. 1 Kaithal
Near Govt ITI Kaithal
Construction of RCC NP2 pipe 300 mm i/d pipe inlet channel, 1 No. S/S tank of size 30.79 m x 30.79 m x 3.66 m , ,1 No. RCC High Level Tanks of size 7.62 m x 3.35 m , 1 No. RCC Filter Beds each of size 9.14 m x 6.10 m , 1 No. RCC Clear Water Tanks
2022_HRY_222393_1
SE Kaithal memo no. 2098 dated 19.05.2022
Open Tender
Civil Works
Works
45 days
Deora
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
₹1.3 L
Yes
29 Jul 2022
19 May 2022
10 Jun 2022
19 May 2022
10 Jun 2022
19 May 2022
Amount
Supply, erection, testing & commissioning of Horizontal spindle split casing pumping sets of minimum four (4) star rating duties directly coupled to AC squarrel cage induction type motor with 1450 RPM, 3 Phase, 50 Hz and accessories as described in Schedule No.II complete in all respect with priming arrangement with complete base frame. (a) Raw Water Pumping Set 1200 LPM with 12 Mtrs. Head.
(b) Clear Water Pumping Set 1200 LPM with 40 Mtrs. Head.
Supply, erection, testing and commissioning of Dry pannel board with suitable size power factor system, MCCB, change over, eathing as per IS: code, Bus bar chamber, wiring, cable etc. including all required electrical accessories complete in all respect to the satisfaction of Engineer-in-charge (a) For Raw Water Pumping Sets for 1200 LPM x 12 Mtrs. Head = 2 Nos. (b) For Clear Water Pumping Sets for 1200 LPM x 40 Mtrs. Head = 2 Nos.
Providing and fixing of LED outdoor Light 120 Watt reputed Make with wiring & switch etc. complete in all respects.
Providing & fixing UPVC 3/4" pipe including specials, Valves etc. For recharging tank at 2 no. pump chamber and 1 no. toilet fitting and making connections complete in all respects
Supply and Installation of Floating arm 150mm i/d complete in all respects (i.e. Floating arm 5 mtrs. Long, 18 gauze zinc sheet, swival flange bend 300mm dia 1 no., float 1 no., Standrad MS Clamp 2 nos. Suitable for 300mm dia, tail piece 300mm dia) at storage and sedimentation tank.
Taking out filter media from Filter Bed & stacking its outside Top Layer
Taking out filter media from filter bed & relaying the same after screening, washing and cleaning into the filter bed for 2nd layer
Taking out filter media from filter bed & relaying the same after screening, washing and cleaning into the filter bed for IIIrd , IVth & bottom layer
Drawing out RCC bed plates of size 16"x16"x2" from filter bed of 10' depth replacing of plates after washing
Washing Cleaning of cwntral drains & sub drains of Filter beds
Less cost of Old Pumping Machinery 2 No. Raw Water & 2 No. Clear Water, Panel Board including Pipe, S.V. NRV. complete in all respects.
Bidder Name
Amount
RAVI PARKASH CONTRACTOR(GSTN-06AJMPP2964K1ZN)
Sunil Kumar(GSTN-NA)
PARDEEP KUMAR CONTRACTOR(GSTN-NA)
Sachin Kumar(GSTN-NA)
PARDEEP KUMAR CONTRACTOR
Sachin Kumar
RAVI PARKASH CONTRACTOR
Sunil Kumar
Sachin Kumar
RAVI PARKASH CONTRACTOR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .