| 1 | L-1₹10.9 LAccepted-Finance C O BUMZOO MATTAN ANANTNAG DISTT KASHMIR 192125 J K | ANANTNAG | JAMMU AND KASHMIR | 192125 | L-1 | Accepted-Finance Being L-1 | |
| 2 | L-2₹13.9 L+₹3.0 L (27.3%)Rejected-Finance NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L-2 | Rejected-Finance Not being L-1 |
| Sl No | Description | Qty | Unit | ms new dar water star L2 | M/S ELITE ENVISION BUILDERS L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge. | 88 | Cum | 250 ₹22,000 | 100 ₹8,800 Lowest |
| 2.00 | Excavation in trenches beyond 1.5m wide and n.exc 3 m deep and getting out in soft /loose soil for laying of cable complete all as specified and directed by Engineer-in-charge. | 0.3 | Cum | 100 ₹30 Lowest | 120 ₹36 |
| 3.00 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soils complete all as specified and directed by Engineer-in-charge. | 50 | Cum | 100 ₹5,000 | 30 ₹1,500 Lowest |
| 4.00 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge. | 40 | Cum | 100 ₹4,000 | 20 ₹800 Lowest |
| 5.00 | M&L Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified and directed by Engineer-in-Charge. | 30 | Cum | 600 ₹18,000 | 380 ₹11,400 Lowest |
| 6.00 | M&L for Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed by Engineer-in-Charge. | 3.8 | Per 1000 Nos | 5,000 ₹19,000 | 3,000 ₹11,400 Lowest |
| 7.00 | M&L for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) as in foundation of pole etc complete all as specified and directed by Engineer-in-Charge. | 0.2 | Cum | 4,500 ₹900 Lowest | 4,800 ₹960 |
| 8.00 | M&L for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge. | 1.6 | Cum | 6,500 ₹10,400 | 5,500 ₹8,800 Lowest |
| 9.00 | M&L for Plain cement concrete (1: 2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all as specified and directed by Engineer-in-Charge. | 0.3 | Cum | 6,000 ₹1,800 Lowest | 6,500 ₹1,950 |
| 10.00 | Supply and lay in repairs cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 35 sq mm 3.5 core laid in trench/ duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge..
Note : The cost of thimbles/lugs and cable gland etc is deemed to be included in quoted rate and no extra payment will be made for it. | 265 | RM | 280 ₹74,200 | 250 ₹66,250 Lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
29 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 861 EWS
GE 861 EWS C/O 56 APO
REPAIR AND MAINT OF EXTERNAL ELECTRIC LOW TENSION DISTRIBUTION SYSTEM AT KHUNDRU GRN UNDER GE 861 EWS
2025_MES_738972_1
GE 861 EWS-52(T)/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE 861 EWS
₹30,000
Yes
21 Apr 2026
8 Nov 2025
6 Dec 2025
8 Nov 2025
29 Nov 2025
22 Nov 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches beyond 1.5m wide and n.exc 3 m deep and getting out in soft /loose soil for laying of cable complete all as specified and directed by Engineer-in-charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soils complete all as specified and directed by Engineer-in-charge.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying complete all as specified and directed by Engineer-in-Charge.
M&L for Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregates ) as in foundation of pole etc complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
M&L for Plain cement concrete (1: 2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and lay in repairs cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 35 sq mm 3.5 core laid in trench/ duct / along pole/wall etc including making connection complete all as specified and directed by Engineer-in-Charge.. Note : The cost of thimbles/lugs and cable gland etc is deemed to be included in quoted rate and no extra payment will be made for it.
Description all as per item No. 10 above but cross sectional area 50 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 25 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 95 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 150 Sqmm 3.5 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 16 Sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
Description all as per item No. 10 above but cross sectional area 10 Sqmm 2 core complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of GI tubing light grade 50mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc complete all as specified and directed by Engineer-in-Charge.
M&L Aluminium conductors, reinforced (ACSR) conductor of any size for OH lines including stretching, binding wire, jumpers, line taps etc including taking down old ACSR complete all as specified and directed by Engineer-in-Charge.
M&L in repairs of Pin type insulator porcelain/polymer, vitreous, white/ brown or green insulators including one galvanised MS spindle, two galvanized iron washer, GI nut of size 100 mm height and 65mm dia 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
M&L in repairs of Shackle type insulators, porcelain, vitreous white/ brown or green including galvanised MS strips, bolt, nuts and washer of size 75mm height and 90mm dia,size of strap section 31x3mm and dia of 12 mm for working pressure 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
S&F in repair of rolling type insulators, porcelain, vitreous white/ brown including galvanised MS strips, bolt, nuts and washer and dia of 12 mm for working pressure 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
M&L for Cross arms, bracings, supports, clamps and back plate fabricated from structural steel section including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shapes size as indicated or directed and inclusive of one primer coat, and one under coat and one finished coat of aluminium paint complete including dismantling cross arms of MS channel complete all as specified and directed by Engineer-in-Charge.
Supply & fix in replacement Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified type 410 SP -31 (9.00 meters long) including two coat of red oxide and applying two coat of aluminium pain with white washing for coping, as specified complete all as specified and directed by Engineer-in-Charge.
Re-stretching only the ACSR conductor fixed on overhead line pole and tightening the ACSR, taking down the conductor from insulators complete with authourised sag and rewinding with insulators in proper position after tightening with new aluminium winding wire of dia 2mm complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat of size 10.0 sqmm for service connection complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repairs of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat of size 16sqmm for service connection complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of danger notice board 1.6mm thick M.S sheet, vitreous enamelled white with letters, figures and conventional skull and bone in signal red colour and fixed with M.S clamps, bolts and nuts of approved size for LT 20x15cm size by replacing the unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED street/security light fitting 36 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED flood lights 30 W 230 Volts AC, energy saving and environmental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs 1.5 Sq mm three core PVC insulated flexible copper conductor wire for street/security light connection complete all as specified and directed by Engineer-in-Charge.
S&F in repair of MCCB 4 pole, 415 volts adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repair of MCCB 4 pole, 415 volts adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCCB 4 pole, 415 volts adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCCB 4 pole, 415 volts adjustable type, 350 Amps with breaking capacity 35/36 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCCB 4 pole, 415 volts adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCCB 4 pole, 415 volts adjustable type, 100 Amps with breaking capacity 25 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of MCCB 4 pole, 415 volts adjustable type, 63 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Changeover switch off load type 415 volts TPN in sheet metal enclosure 4 pole of capacity 400 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Changeover switch off load type, 415 volts TPN in sheet metal enclosure 4 pole of capacity 100 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in repair of Changeover switch off load type 415 volts TPN in sheet metal enclosure 4 pole of capacity 200 Amps complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of outdoor type SMC junction box of size 170x170x105mm one piece moulded SMC door hinged fixed base with hinged right or left side and fixed to the foundation pole with suitable fixing arrangement bus bar with single electrolytic aluminium for both phase and neutral supported on FRP insulator and cut out complete fixed on the pole with suitable inlet and outlet , provision for cable connection, MCB SP 6 Amps rating 'B' curve for controlling the pole light including necessary connection, complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 32× 6mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness around the earth electrode complete all as shown in electrical plate No 3 of SSR part-I including welding with suitable electrode and testing complete all as directed. NOTE :- (i) Main earthing strip from earth plate electrodeto test point upto length of 7.5 mtrs length shall deem to be included in the unit rate quoted against this item. (ii) M&L Tubing GI medium grade 40mm dia for protection of earthing strip and passing the Road/passes and etc. shall be deemed to be included in the unit rate quoted against this item. (iii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Taking out from trenches/poles/wall etc LT UG Cable PVC insulated sheathed with multistranded aluminium conductor armoured and relaying after fault rectification duly tested in trenches/Poles/Wall of LT UG Cable of any sizes including Earth work complete all as specified and directed by Engineer-in-Charge.
Supply, fixing & commissioning in replacement of sheet metal enclosure (junction/feeder pillar box) of suitable size fabricated with CRCA sheet steel 2mm thick, front door openable type, powder coated included earth bars cement spill protector cable ties, blanking plates suitable for housing 4 pole MCCB 63 Amp as incomer, copper bus bar 200 Amp rating outgoing MCB 40 Amp SPN, multifunctioning meter, indication lamp etc complete and suitable to accommodate the following accessories:- a) MCCB 63 Amps 4 pole, 16 KA, Thermal magnetic - 1 Nos b) MCB, SPN 25 Amps,10KA- 6 Nos (Out going) c) MCB, SP 6 Amp,10KA,Thermal magnetic- 2 Nos (Out going) d) Indication lamps (R,Y,B) LED type - 1 set e) Copper bus bar 200 Amp rating with colour coded heat shrinkable sleeve TPN- 01 set Note: (i) LT panel cum/ junction box shall be flush in staircase/ sub station room wall & adequate height. (ii) Cement work, plastering work & painting with existing colour is deemed to be included in quoted rate.
Supply, fixing in replacement & commissioning sheet metal enclosure (junction/feeder pillar box) of suitable size fabricated with CRCA sheet steel 2mm thick, front door openable type, powder coated included earth bars cement spill protector cable ties, balnking plates suitable for External electric supply 4 pole as incomer and outgoing (both) copper bus bar 200 Amp rating , multifunctioning meter, indication lamp etc complete all as specified and directed by Engineer-in-Charge.
ms new dar water star (BID ID -3491167)
stage.html
html • 0.04 MB
technical_827445.pdf
techsummary_827445.pdf
finance_827445.pdf
BOQ Comparative Chart
xlsx
finsummary_827445.pdf
cancelled_1.pdf
pdf • 0.14 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tender52T.pdf
Tender Documents • 1.06 MB
BOQ_827445.xls
BOQ • 14.14 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .