| 1 | L1₹49.3 LAccepted-AOC SCHOOL LINE NEAR MINNIEBAY JUNCTION SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹49.3 L Quoted ₹50.6 L | L1 | Accepted-AOC L1 |
| 2 | L2₹52.2 L+₹1.6 L (3.26%)Rejected-Finance | ₹52.2 L+₹1.6 L (3.26%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹54.7 L+₹4.1 L (8.20%)Rejected-Finance | ₹54.7 L+₹4.1 L (8.20%) | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
24 Feb 2023, 6:00 pmClosed
GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
REPAIR REPLACEMENT AND MAINT OF INTERNAL ELECTRIFICATION, ELECTRICAL FITTINGS, FIXTURES AND REPAIR MAINT OF EM INSTALLATIONS LIGHTENING PROTECTION SYSTEM AND OTHER ALLIED WORKS AT INS UTKROSH NTS TEYLERABAD,NAD DOLLYGUNJ, CHOULDARI AND PORTHAPUR FIL
2023_MES_577617_1
8221/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Minniebay Port Blair
As per tender documents
11 documents required · 11 mandatory
₹500
GE Minniebay
₹98,000
Yes
4 Mar 2023
28 Jan 2023
27 Feb 2023
28 Jan 2023
24 Feb 2023
11 Feb 2023
Amount
Taking down carefully copper/aluminium point wiring (light, Fan, Socket or power) including fitting such as switches ceiling roses, pendants, regulators, Sockets etc removing the unserviceable materials from site and making the disturbed surface good to match with existing finish etc all as specified and directed by Engineer-in-Charge.
Taking down carefully copper/aluminium Sub main wiring of size 1.5/2.5/4/6/10/16/25 Sqmm from surface/concealed /existing conduit of any height removing unserveciable materials from site and making the disturbed surface good to match with existing finish etc all as specified and directed by Engineer-in-Charge.
M&L for point wiring with PVC Insulated unsheathed Cable 2 runs of 1.5 Sqmm multistranded FRLSH copper conductor 1100 Volt grade IS-694 and drawing in and including steel conduit stove enamelled medium grade suitable dia with fixing materials, sunken terminal MS boxes of 2mm thick, laminated sheet cover 3mm thick and including provision of earth wire PVC insulated unsheathed 1.5 Sqmm stranded FRLSH copper conductor single core cable connected to common earth dolly all as specified and directed by Engineer-in-Charge for the following:-
One light/fan point controlled by 5/6 amps one way switch
One 3 pin socket outlet 5/6 amps on the same board
One 3 pin socket outlet 5/6 Amps on the Independent board
One bell/buzzer point controlled by one push button on the Independent board
One additional light point on the same switch circuit
All as per item No 3 here in before but with 2.5 Sqmm single core PVC multi stranded FRLSH copper conductor for one three pin socket 15 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly all as specified and directed by Engineer-in-Charge
All as per item No 3 herein before but with 4 Sqmm single core PVC multi stranded FRLSH copper conductor for one three pin socket 20 Amps on independent board/ metal clad socket for AC point including continuous earth wire PVC insulated 4 Sqmm FRLSH copper solid conductor to common earth dolly all as specified and directed by Engineer-in-Charge.
M&L point wiring with 1.5 Sqmm (nominal area) PVC unsheathed multi stranded copper conductor pvc insulated 1100 volt FRLSH grade multi stranded cable drawn through and including PVC casing caping/conduit ISI marked minimum 20mm size and its accessories complete along with 1.5 Sqmm cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,surface, in walls/ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches, switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as directed and specified for the following.
One light /fan/bell point controlled by one switch.
One 5 Amps plug point independent board controlled by one switch.
One three pin switch socket 5 Amps plug point on same board.
All as per item No. 6 above but with 2.5 Sqmm single core multi standard copper conductor for one three pin socket 5 Amps on independent board including continuous earth wire PVC insulated 2.5 Sqmm copper solid conductor to common earth dolly.
All as per item No.6 above but with 4 Sqmm single core multi standard copper conductor for one three pin socket 15 Amps on independent board/ metal clad socket for AC point including continuous earth wire PVC insulated 4 Sqmm copper solid conductor to common earth dolly
S&F switch piano, flush button type, single pole, one way15 amps complete all as specified and directed.
S&F socket outlet 2-in-1, 3 pin, 5 and 15 amps, flush type complete all as specified and directed.
S&F bell push 5 Amps for electric Bell/Buzzer, ding dong AC 230 Volt single pole complete all as specified and directed.
S&F electric Bell, ding dong type AC 230 Volt single pole complete all as specified and directed.
supply and fix Switch Piano flush button type, single pole, one way 5 Amp complete all as specified and directed.
S&F socket piano flush type 2-in-1 2/3 pin 5 Amps all as specified and directed.
S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 to 32 Amps complete all as specified and directed.
S&F ceiling rose, surface bakelite 65 mm x 30 mm, 3 terminals complete all as specified and directed.
S&F Electronic dimmer type fan regulator 230 Volt step type complete all as specified and directed.
S&F Switch socket combination 5/6 Amps complete all as specified and directed.
S&F Switch socket combination 15/16 Amps complete all as specified and directed
M&L for Sub main wiring complete with 2x1.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 1.5 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2x2.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 2.5 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2x4 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 4 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2x6 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 6 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2x10 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 10 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 4 x 16 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 1x 16 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 4x25 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 Volts grade, drawn through including PVC Casing Capping in surface /PVC conduit on surface (as required) along walls roofs etc including 1 run of 25 sqmm size PVC insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly all as specified and directed by Engineer-in-Charge. Note for Item No. 20 to 26:- (i) All three wire/cable(phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two/four runs of cable and one/two runs of earth conductor including one run of PVC casing/capping or PVC Conduit shall be measured as one unit run.
S&F in replacement of PVC Gang box with 15 Amp multi purpose Switch and Socket complete all as specified and directed by Engineer-in-Charge.
All as per item No. 27 above but 5 Amps, 5 Pin all as specified and directed by Engineer-in-Charge.
S&F in replacement of Cast Iron/pressed steel terminal boxes 250mmx300mmx60mm , 3mm thick rectangular with plastic laminated sheet cover all as specified and directed by Engineer-in-Charge.
All as per Item No.29 above but for 200X150mm size all as specified and directed by Engineer-in-Charge.
All as per Item No.29 above but for 175X100mm size all as specified and directed by Engineer-in-Charge.
S&F in replacemet of MCCB, 415 volts, 4 pole adjustable thermal setting type 36 KA, 200 A complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement MCB Double Pole 63 Amps, 240 Volts, 10 kA, 'C' Curve all as specified and directed by Engineer-in-Charge.
supply and fix in replacement MCB Double Pole 32 Amps, 240 Volts, 10 kA, 'C' Curve all as specified and directed by Engineer-in-Charge.
supply and fix in replacement MCB Double Pole 40 Amps, 240 Volts, 10 kA, 'C' Curve all as specified and directed by Engineer-in-Charge.
supply and fix in replacement MCB Triple Pole 40 to 63 Amps, 240 Volts, 10 kA, 'C' Curve all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable distribution board by disconnection of electric connection carefully SPN DBs, Main Switch including old models load star MCBs,Isolators,etc and making good to the disturbed surface complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceabl DBs TPN / Main Switches including old models load star MCBs, isolators,fuses,etc and making good to the distrubed surface complete all as specified and directed by Engineer-in-Charge.
supply and fix of load line vertical DB TPN 8 way IP 43 IK-09 with metal double door suitable for Provision of MCCB, 4P 36 KA 160 Amp,housing MCB's complete all as specified and directed by Engineer-in-Charge.
supply and fix of load line vertical DB TPN 12 way IP-43 IK-09 with metal double door suitable for Provision of MCCB, 36 KA 160 Amp for housing of MCBs complete all as specified and directed by Engineer-in-Charge.
supply and fix load line vertical DB TPN 4 way IP 43 IK-09 with metal double door suitable for Provision of MCCB , 36 KA 100 Amp for housing of MCBs complete all as specified and directed by Engineer-in-Charge.
S&F sheet metal distribution board SPN 4 way with category of protection double door type IP-43 IK-09 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs complete all as specified and as directed by Engr-in-Charge Make - Legrand Cat part No-5076 80 or makes mentioned in list of Makes. Note : Front cover of DB shall be flushed with wall surface
S&F sheet metal distribution board SPN 12 way with category of protection double door type IP-43 IK-09 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs complete all as specified and as directed by Engr-in-Charge Make - Legrand Cat part No-5076 73 or makes mentioned in list of makes Note : Front cover of DB shall be flushed with wall surface
S&F sheet metal distribution board SPN 8 way with category of protection double door type IP-43 IK-09 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs complete all as specified and as directed by Engr-in-Charge Make - Legrand Cat part No-5076 82 or makes mentioned in list of makes. Note : Front cover of DB shall be flushed with wall surface
S&F sheet metal flameproof distribution board SPN 8 way with category of protection double door type IP-43 IK-09 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs complete all as specified and as directed by Engr-in-Charge Note : Front cover of DB shall be flushed with wall surface
S&F in replacement of MCCB 415 V, 160 Amps, 36KA 3pole with thimbles/lugs and nut,bolts complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCCB 125 415 V, 100 Amps, 36KA 3 pole and electric connection with copper/aluminium thimbles complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB TPN 6 to 32 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB TPN 40 to 63 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB Four Pole 100 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB SP 6 to 32 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and as directed by Engr-in-Charge
S&F in replacement of MCB SP 40 to 63 Amps, 440 Volts, 10 kA, 'C' Curve complete all as specified and as directed by Engr-in-Charge
M&L for rewinding of ceiling fan, 1200 /1400 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnished including testing for required efficency complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of exhaust fan, 300 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnished including testing for required efficency complete all as specified and directed by Engineer-in-Charge.
All as per item No. 54 above but for upto 450 mm sweep(18") all as specified and directed by Engineer-in-Charge.
All as per item No. 54 above but for upto 600 mm sweep(24") all as specified and directed by Engineer-in-Charge.
M&L for rewinding of cabin/wall mounted fan, 300/450 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnished including testing for required efficency complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of air circulator fan, 600 mm sweep with super enamelled copper wire and insulation of starter with polyester paper/manllex paper with cotontak binding, heat varnished including testing for required efficency complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement in replacement of bearing of ceiling fans 1200/1400 mm of any size for proper running and testing all as specified and directed by Engineer-in-Charge.
supply and fix in replacement in replacement of Gun metal bushes for ceiling fans of size 1200/1400 mm including oiling and testing for proper running all as specified and directed by Engineer-in-Charge.
supply and fix in replacement in replacement of rotor shaft of ceiling fans of size 1200/1400 mm sweep all as specified and directed by Engineer-in-Charge.
Supply in fix in replacement of ceiling fan stator of size 1200/1400 mm sweep size match to existing fan rotor of any make as per site requirment all as specified and directed by Engineer-in-Charge.
M&L Painting of ceiling fans 1200/1400mm sweep with two coats of synthetic enamel paint by means of suitable spary gun after cleaning and prepairing the surfaces and marking the circular ring line 3 mm thick line with golden colour on bottom centre all as specified and directed by Engineer-in-Charge.
All as per item No.63 above but exhaust fan 300/450/600mm sweep all as specified and directed by Engineer-in-Charge.
All as per item No.63 above but wall/padestal fan 300/450/600mm sweep all as specified and directed by Engineer-in-Charge.
S&F in replacement Exhaust fan single phase 1400 RPM 12'' sweep heavy duty complete with louver shutter and incl fixing water proof ply wood 12 mm thick of size 350X350mm for fan base after cutting 300 mm dia of suitable size all as specified and directed by Engineer-in-Charge. Note :old unserviceable fans shall be cleaned and handed over to AGE EM store yard.
All as per Ser Item No.66 but 450 mm sweep 900 RPM
All as per Ser Item No 66 but 600 mm sweep 900 RPM
S&F in replacement ventilating fan 250 mm sweep 230Volts AC with sturdy blades fully plastic body complete sound proof incl fixing water proof ply wood 12 mm thick of size 300x300 mm for fan base after cutting 250 mm dia of suitable size all as specified and directed by Engineer-in-Charge. Note :old unserviceable fans shall be cleaned and handed over to AGE EM store yard.
S&F in replacement single phase, 230 volts, 50 Hz, wall mounted fan, 400 mm sweep fixed on wall with fan clamp/hook, connecting electrically all as specified and directed by Engineer-in-Charge. Note :old unserviceable fans shall be cleaned and handed over to AGE EM store yard.
S&F in replacement Ceiling Fan five star rated 1200 mm sweep single phase 230Volt AC energy saving complete as per manufactrer specification complete all as specified and directed by Engineer-in-Charge. Note :old unserviceable fans shall be cleaned and handed over to AGE EM store yard.
S&F in replacement of Pedestal Fan 450 mm sweep single phase AC Energy saving complete as per manufactrer specification complete all as specified and directed by Engineer-in-Charge. Note :old unserviceable fans shall be cleaned and handed over to AGE EM store yard.
S&F Bracket assembly of various sizes as required for hanging ceiling fan with rubber shackle nuts, bolts and split pin complete all as specified and directed by Engineer-in-Charge.
S&F condenser 2.5 mfd including fixing of clamps with screws, sleeves etc complete all as specified and directed by Engineer-in-Charge.
All as per item No.74 above but 3.15 mfd all as specified and directed by Engineer-in-Charge.
All as per item No.74 above but 4 mfd all as specified and directed by Engineer-in-Charge.
supply and fix in replacement ceiling fan blades as per existing pattern (set of three) of size 1200/1400 sweep complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Fan regulator step type electronic 250 volt AC complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement down rod of ceiling fan of 1m long GI pipe medium grade ISI marked including two coats of synthetic enamel paint over a coat of red oxide primer with bolts/check nuts, washers etc as per existing size and shape of fans incl New U hook with rubber reel with nut bolt and washer including drilling, threading complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement of PVC canopy (set of two) for ceiling fans 1200 mm/1400 mm sweep complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement ceiling fan bottom cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement ceiling fan Top cover suitable for 1200/1400 mm sweep with existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement exhaust fan blade as per existing make and model of size 300 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as per ser item No.83 above but 450 mm sweep all as specified and directed by Engineer-in-Charge.
All as per ser item No.83 above but 600 mm sweep all as specified and directed by Engineer-in-Charge.
supply and fix in replacement wall fan blade as per existing make and model of 300 mm/450 mm sweep complete all as specified and directed by Engineer-in-Charge.
All as per ser item No. 86 above but 600 mm sweep all as specified and directed by Engineer-in-Charge.
supply and fix in replacement in replacement of Air circulator Fan blade 600 mm sweep single phase AC Energy saving complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth plate 32x6mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50 mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick with 10 mm dia reinforcement 100mm c/c and PCC chamber pit with PCC 1:2:4 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 all as specified and directed by Engineer-in-Charge.
S&F in repair 1x 20 W LED tube rod complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1x 18 W LED tube rod complete all as specified and directed by Engineer-in-Charge.
S&F in repair 1x 10 W LED tube rod complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED electronic driver 24/33W complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED electronic driver 15/18W complete all as specified and directed by Engineer-in-Charge.
S&F in replacement LED electronic driver 9/12W complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of LED tube light fitting, 1x18 w, 230v surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, Flicker free, high efficiency and robust industrial batten family suitable for Surface, Wall and Conduit mounting connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of LED tube light fitting, 1x20 w, 230v surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, Flicker free, high efficiency and robust industrial batten family suitable for Surface, Wall and Conduit mounting connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge.
Supply and fix in replacement of LED tube light fitting, 1x23 w, 230v surface and wall mounted LED batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver, Flicker free, high efficiency and robust industrial batten family suitable for Surface, Wall and Conduit mounting connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed by Engineer-in-charge.
S& F in repair LED mirror light fittings 1x12w, 230V Helios type fixed on wall / surface including necessary connections all as specified and directed by Engineer-in-Charge.
S & F in repair LED light fitting, 1x33 w, 230v .2x2 recessed mounted general purpose square shaped luminaire with high transitivity diffuser suitable for office application with profiled & flat diffuser fitted on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr-In-Charge.
S & F in replacement LED light fitting, 1x12 w, 230v .down light recessed mounted genaral purpose squre/round shaped luminaire with high transmitivity diffuser suitable for office application with profiled & flat diffuser fiited on ceiling connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engineer-in-Charge.
S&F in replacement fan regulator 120W, 2 module modular type as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement flameproof Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A,250V, 2P+earth complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement of aluminium service wire 6sqmm 2 core 1100 volts grade fixed on wall/roof etc complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement LED lamp 9W 220V 50HZ complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement LED lamp 12W 220V 50HZ complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Modular switch 1 way 6A, 220V 50Hz 1module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Modular switch 1 way 16A, 220V 50Hz 1module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Modular switch 2 way 6A, 220V 50Hz 1module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Modular bell push 6A, 220V 50Hz 1module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Socket, 5/6A - 2/3 pin combined ,220V 50Hz 2module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Socket, 15/16A - 2/3 pin combined ,220V 50Hz 2module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement modular Fan step regulator, 120W - 1/2 module ,220V 50Hz as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement White cover plate with frame,1 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement White cover plate with frame,2 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement White cover plate with frame,3 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement White cover plate with frame,4 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement White cover plate with frame,6 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement metal flush box 1/2 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement metal flush box 4 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement metal flush box 6 module as per existing make and model complete all as specified and directed by Engineer-in-Charge.
supply and fix in replacement Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant fittings as per existing make and model complete all as specified and directed by Engineer-in-Charge.
S&F in replacement cable PVC insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 10 Sq mm for hanger motor up to 25 Mtr height and necessary clump to move the round cable all as specified and directed by Engineer-in-Charge.
S&F in replacement cable PVC insulated sheathed, unarmoured, round water proof with stranded copper conductor 1100 V grade of size 4 core 16 Sq mm for hanger motor up to 25 Mtr height and necessary clump to move the round cable all as specified and directed by Engineer-in-Charge.
Taking down carefully loose / hanging / deshaped / aluminium / copper strips of any size & type from roof / wall of the building including unserviceable insulators etc all as directed by Engr - in - Charge .
Taking down unserviceable rusted test point terminal boxes from wall on similar position all as directed by Engr - in - Charge at site .
Taking down unserviceable air termination rod all as directed at the roof top of hanger building etc upto 30m height complete all as specified and directed by Engineer-in-Charge.
Supply & fix aluminium strips 25x3 mm on porcelain insulator 15 BMD size 'T' type not more than 50 cm apart all as specified and directed by Engineer-in-Charge.
S&F copper strips 20x3.15 mm porcelain insulator 15 BMD size 'T' type placed not more than 50 cm apart all as directed by Engr - in - Charge .
S&F test point terminal block made out of gun metal or phosphorous bronze size 150x150x75 mm depth , drilled , cutting upper & lower portion for incoming & outgoing including double insulators two coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Supply and fix air termination single pointed aluminium 12 mm dia & 300 mm long complete all as specified and directed by Engineer-in-Charge.
Supply and fix air termination single pointed copper 12 mm dia & 300 mm long complete all as specified and directed by Engineer-in-Charge.
S&F stay strand galvanised of size 7 / 4 mm complete with ms clamps , nuts bolts etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of porcelain insulators 15 BMD size T type with nut bolts / screws for fixing of copper / aluminium strips / GI strips on walls etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of galvanised perforated cable tray on wall complete with accessories nuts bolts etc of size 100x12 mm thick complete all as specified and directed by Engineer-in-Charge.
Material and labour for repairs of earthing chamber of size 450x450x300mm outside and 250x250x250 mm inside of Plain Cement Concrete (1:4:8) type D-2 & including provn of precast PCC cover including painting of two coat of cement based paint/colour wash as directed complete all as directed by Engr - in - Charge .
Material and labour for Painting of earth pit chamber with two coat of cement based paint/colour wash including making the earth pit and colour of paint as directed by Engr - in - Charge .
M&L for earthing resistance testing of existing earth pits with different types of earth megger as to suit by disconnecting earth continuity conductor from test terminal block / panel and recording the results in triplicate duly Signed by tenderer, MES and users rep and reconnecting the earth continuity conductor complete all as specified and directed by Engineer-in-Charge.
Supply and errect vertically GI steel tubing 40 mm bore light grade ISI marked complete with fittings for raising height of existing air termination rods and laying of pipes for protection of earthing strips erecting vertically complete all as specified and directed by Engineer-in-Charge.
Supply and lay of GI pipe 80mm bore medium grade ISI marked for protection of cable including bends, socket etccomplete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with GI earth electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 meter below normal ground level with top edge of earth plate at a depth not less than 1.5 meter below normal ground surrounded from all sides by 15 CM thick and packed layer of charcoal dust and common salt filling in alternate layers cleaned connected to and including GI earth plate 25x4mm size upto 7.5 mtr by means of bolts, nuts, check nuts and washers made of galvanised iron and protected light grade 50 mm dia 5 mtr long GI pipe connected to main control board and GI pipe light grade 20 mm bore for watering and including funnel wire mesh, RCC pit cover 50 mm thick with 10 mm dia reinforcement 100mm c/c and PCC chamber pit with PCC 1:2:4 type C-2 (including excavation and earth work disposal of surplus soil to a distance not exceeding 50 meter) and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3 mm thick buried directly in ground (earth pit not less than 2.25m deep below GL) with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper earth strip 20x3 mm size connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 15 mm dia GI pipe medium grade for protection and 40mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6), type CI chamber. MS funnel, wire gauge. 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos. 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I incl replacement of old unserviceable earthing complete all as specified and as directed Note: (i) Cost of copper earth strip and GI protection pipe upto 7.5m length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning & filling, PCC chamber pit, RCC cover & test point.(iii) All accessories required for Copper plate electrode required, as specified and as directed.(iv) If the desired earth resistance is not achieved during testing as per IS , the complete earthing shall be replaced / repaired by the contractor at his own cost and no extra claim shall be admissible. (v) Earth test report shall be submitted to Accepting Officer for the payment of RAR / FB
S & F GI earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles for earthing etc. as required complete all as specified and directed by Engineer-in-Charge.
S & F GI earth continuity conductor or main earthing lead of size 25x4 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles as required complete all as specified and directed by Engineer-in-Charge.
S & F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles as required complete all as specified and directed by Engineer-in-Charge.
Supply and fix earth pit chamber board of 3.15mm thick mild steel sheet of size 45cmX30cm fixed with12mm thick MS rod two nos up to 90 cm height by nuts/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters 6cm height i.e Earth pit No, Location, Earthing test Value and date complete all as specified and directed by Engineer-in-Charge.
Supply and laying in replacement LT UG cable XLPE insulated armoured and PVC sheathed 1100 volts grade with aluminium conductor stranded of following sizes complete all as specified and directed by Engineer-in-Charge. :- Note : Necessary earthwork shall be measured and paid separately
50 Sqmm 3.5 core
95 Sqmm 3.5 core
120 Sqmm 3.5 core
185 Sqmm 3.5 core
240 Sqmm 3.5 core
300 Sqmm 3.5 core
Supply & laying in replacement Telerex DWC (Double Wall Corrugated) HDPE pipe ISI marked of outer dia of 77 mm and inner dia 63 mm polyethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge.
All as per item no- 149 above but outer dia of 110 mm and inner dia 95 mm complete all as specified and directed by Engineer-in-Charge.
Excavation in soft / loose soil not exceeding 1.5m wide and n exc 1.5m depth and getting out including forming of bottom for laying cable complete all as specified and directed by Engineer-in-Charge.
Excavation in hard / dense soil Including road cutting etc not exceeding 1.5m wide and n exc 1.5m depth and getting out including forming of bottom for laying cable complete all as specified and directed by Engineer-in-Charge.
Returning filling using excavated soil including spreading leveling, watering and well ramming in layers n exc 25 cms complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M/s Pooja Enterprises
bansal construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .