GE AIRFORCE LOHEGAON
GE AIRFORCE LOHEGAON
REPAIR REPLACEMENT AND MAINTENANCE OF DEFECTIVE EXTERNAL WATER SUPPLY PIPELINE AND VALVES MISC ITEMS AT TECH AREA OMQ NP AREA MAINTENANCE REPAIR AND REPLACEMENT OF UNSERVICEABLE EARTHING WITH CONNECTED ITEMS AT 509 AREA VIMAN NAGAR AKASH NAGA
2025_MES_695386_1
8855
Open Tender
Electrical and Maintenance Works
Item Rate
GE AIRFORCE LOHEGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE AIRFORCE LOHEGAON
₹90,000
Yes
7 Apr 2025
29 Jan 2025
3 Mar 2025
29 Jan 2025
25 Feb 2025
13 Feb 2025
Amount
Taking up or down unserviciable / old GI tubing any grade and fittings connections ( including dewatering of trench) and removal from site complete all as specified and directed.
15mm dia bore
20 mm dia bore
25mm dia bore
40mm to 80mm dia bore
Refixing / Relaying old steel tubing and connections in new or old position (Walls, ceiling, floors,trenches etc. complete all as specified and directed.
15 mm dia bore
20 mm dia bore
25mm dia bore
40mm to 50mm dia bore
Supply & lay and jointing tubing medium grade galvanised iron pipes, ISI marked with all fittings such as bends, tees, elbows, nipple, unions, short pieces, sockets etc and laid in trenches complete all as specified and directed of following sizes :-
15mm dia bore
20 mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
80mm dia bore
Taking down unserviceable gun metal gate valves including S & F gun metal gate valves with iron wheel head screwed both end for iron pipe and fixed complete all as specified and directed:-
20mm dia bore
25mm dia bore
40mm dia bore
50mm dia bore
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for laying of GI tubing / taking out of GI tubing and getting out in complete all as specified and directed :-
Soft /loose soil
Hard / dense soil
Soft disintegrated soil
Returning filling in including spreading levelling, watering and well ramming in layers n. exc 25cm with soil obtained from excavation complete all as specified and directed
Removing excavated soil / material n. exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above the starting point complete all as specified and directed
Repairing of leakages/blockage GI pipeline of size 15 mm,20mm,25mm by replacing the Tees, bends, sockets,unions,nipple and providing the other materials required to complete the job including pipeline of length upto 3 meter, excavation and earth work complete all as specified and directed. Note:- Required length exceeding 3 meter will be measured under respective item.
Repairing of leakages/blockage GI pipeline of size 40mm,50mm by replacing the Tees, bends, sockets,unions,nipple and providing the other materials required to complete the job including pipeline of length upto 3 meterl, excavation and earth work complete all as directed. Note:- Required length exceeding 3 meter will be measured under respective item.
Repairing of leakages/blockage GI pipeline of size 80mm by replacing the Tees, bends, sockets,unions,nipple and providing the other materials required to complete the job including including pipeliene of length upto 3 meter, excavation and earth work complete all as specified and directed. Note:- Required length exceeding 3 meter will be measured under respective item.
Supply only Calcium Hypo Chlorite 65% chlorine content (Calcium based granular) complete all as specified and directed
Dismantling / taking out insulator of any size / type from existing electric LT lines complete all as specified and directed
Dismantling / taking out existing ACSR conductor any size from existing over head lines incl disconnection complete all as specified and directed
Dismantling cross-arms of M.S. channel or angle sections, clamps, nut bolts etc. complete all as specified and directed
Refixing of serviceable cross arms, channel or angle sections obtained under above item No. 2 including painting of cross arms with two coats of synthetic enamel paint complete all as specified including necessary welding complete all as specified and directed
Material and labour for disconnecting serviceable LT cable of any size and core from LT poles and terminate it into LT panel using suitable aluminium lugs, cable glands and other accessories. The cable shall be laid underground and jointing of cable to be done if falls short to the LT panel complete all as specified and directed. Note: Cost of aluminium lugs, cable glands and termination of cable into LT panel shall be included in the quoted rate. (ii) Excavation, returning , refilling , crushed sand, brick cover and jointing kit will be measured and paid seperately.
M & L for disconnecting /Removing the under ground cable binded/Jointed with OH conductor removing carbon cutting of cable size 4 core 10 sqmm to 3.5 core 185 Sqmm and rebinding with the aluminium conductor of suitable size with OH conductor installation on 9/11 meters height pole complete all as specified and directed. Note: This scope includes T&P
Material and labour for relaying of existing LT cable of any size up to 70 Sqmm 3.5/4 core under the ground complete all as specified and directed. Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately complete all as specified and directed
Material and labour for relaying of existing LT cable of any size above 50 Sqmm 3.5/4 core to 300 Sqmm 3.5 core under the ground complete all as specified and directed. Note: Excavation, returning , refilling , crushed sand, brick cover will be measured and paid seperately.
Material and labour for servicing of LT panel duly isolated / de-energize the supply of LT panel of capacity ranging from 200 Amps to 1000 Amps and voltage 415/230 volts. The maintenence includes the following tasks:- (i) Cleaning of burnt Bus bar using CTC chemical. (ii) Taking out all incoming and ougoing cables from the LT panel and also taking out cable loop from ground. (iii) Removing old insulation and providing new heat shrink insulating sleeves, connecting and fixing in the same panel using new GI nut bolts washers of suitable size. (iv) Removing of old and broken cable connectors in the LT panel and providing new connectors of suitable capacity and fixing in the same panel using nut bolts and other accessories. (v) Removing of burnt and worn out lugs from the cables and replace it with new aluminium lugs of suitable size and capacity as per the size of the cable. (vi) Removing of worn out connecting wires inside the panel and replace it with new wires of suitbale capacity and size. Note:Cost of all material as mentioned above required for maintenance must be included in the quoted rate
Repair/ overhauling of LT Air Circuit breakers of any make and capacity 630 to 1000 amps, 3pole/ 4 pole and replacement of minor items like springs, washers, bolts, nuts and other insulating material including calibration and testing of control and protection devices of equipments in the following steps all as directed by Engineer-in-Charge:- (i) Disconnecting and taking out the breaker after taking shut down of the respective panel and check the defects. (ii) Overhauling the ACB by opening all parts and lubricating the moving parts as per requirement. (iii) Re-assembling the air circuit breaker complete, installing to its original position, testing and commissioning the breakers for both tripping and closing mechanism for proper fucntioing of the breaker all as specified and directed
Material and labour for painting to existing steel tubular poles 7/9/11 mtr long including cross arms,looping box,GI pipe bracket,clamps etc. with one coat of aluminium paint including preparation of surfaces and feeder name and pole number with zebra type painting upto 6 feet from bottom with alternate patch of size 1 foot of white and light blue colour paint complete all as directed.
Material & Labour for painting to feeder pillar box / LT panel & duct cover etc, including angle iron frame with two coat of grey synthetic enamel paint including welding of door with proper size new hinges of suitable size and locking arrangements where required complete all as specified and directed
Taking down and Supply & fix line separator suitable for LT OH line of 3 phase and neutral conductor complete all as specified and directed
All as per item No.14 above but single phase and neutral conductor complete all as specified and directed
Trimming of trees not exc 30 cm girth including cutting of upper portion of branches and disposal of same at a distance not exc 50 mtr and clearing of site complete as directed.(Note:Tools/ladder required for cutting/trimming of trees will be provided by the contractor at no extra cost and cost of the same be deemed to be included in the quoted rate.) complete all as specified and directed Note:Each Span will be measured from one pole to another pole
Provn of services for cable fault location for LT UG cable, XLPE insulated 1100 Volts, of any size with fault detector machine complete all as specified and as directed.
Material and labour for straight through jointing kits heat shrinkable type LT UG XLPE cable heavy duty armoured sheathed including excavation in any strata, taking out cable, and making disturbed surface after relaying the cable making joints suitable for aluminium conductor of size given below complete all as specified and directed
6 to 16 sqmm 2.0 core
6 to 16 sqmm 3.5 core
25 to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
150- 185 sqmm 3.5 core
240-300 sqmm 3.5 core
Supply and fix HDPE Pipe 100/110mm PE 100 Grade pipe PN 8 (SDR 17) with all connected accessories of sizes 100 mm complete all as specified and directed
Supply and fix HDPE Pipe 50 mm PE 100 Grade pipe PN 8 (SDR 17) with all connected accessories of sizes 100 mm complete all as specified and directed
Taking down and S&F shackle type insulator vitreous procelain white / brown / green with and including galvanised mild steel straps, washer insulator, bolts and nuts, insulator of size 100 mm height and 115 mm max dia with working pressure 1100 volt and galvanised steel straps 3 to 5 mm size and suitable size nut and bolts complete all as specified and directed
M&L for taking down old unsv insulator and supply and fix pin type procelain white / brown / green / insulator including galvanised mild steel spindle, two galvanised iron. Washer and one galvanised iron nut, 100mm height 65 mm dia for 1100 volts grade complete all as specified and directed
Supplying, spreading & leveling stone aggregate size of 20 mm grade to the existing sub station or complete all as specified and directed
Taking down and Supply and fix in repair / replacement of MCCB FP 630 Amps Adjustable type with breaking capacity 50 KA including connections and testing for proper functioning complete all as specified and directed
Taking down and Supply and fix in repair / replacement of MCCB FP 400 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed
Taking down and Supply and fix in repair / replacement of MCCB FP 250 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of MCCB FP 200 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed
Taking down and Supply and fix in repair / replacement of MCCB FP 160 Amps Adjustable type with breaking capacity 36 KA including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of MCCB TP 200 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of MCCB TP 160 Amps Adjustable type with breaking capacity 25 KA including connections and testing for proper functioning complete all as specified and directed
Taking down and Supply and fix in repair / replacement of MCCB TP 100 Amps Fixed type with breaking capacity 16 KA including connections and testing for proper functioning complete all as specified and directed
Supplying, Laying, jointing, testing and commissioning of LT under ground cable 1100 volts grade XLPE (cross linked polythene ) armoured with galvanised round steel wire or steel strip , electric power cable heavy duty, with multi stranded aluminium conductor, laid in trenches, ducts fix on walls/poles with proper size saddles and clamp laid under roads/path/ drain /colverts or enclosed in GI pipe/ fix complete all as specified for following size:-
6 sqmm 4 core
10 sqmm 4 core
16 sqmm 4 core
25 sqmm 4 core
35 sqmm 3.5 core
50 sqmm 3.5 core
70 sqmm 3.5 core
95 sqmm 3.5 core
120 sqmm 3.5 core
185 sqmm 3.5 core
240 sqmm 3.5 core
300 sqmm 3.5 core
Material and labour for stone dust sand cushioning to under ground cable, provided with a layer 8 cm before and 15 cm after laying and stretching jointing and testing the cable all as specified and directed. [Note : Measuremenet will be done after punning]
M&L for brick protection covers laid over cables of sub class'B' bricks all as specified and directed.
Supply and fixing MCB DB TPN 4 way IP 43-IK-09 with metal double door suitable for housing of MCBs complete all as directed by Engineer-in- Charge.
S&F MCB TPN 63 Amp 10 kA 415 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge.
S&F MCB DP 40-63 Amp 10 kA 240 Volt, 'C' Curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge.
M&L for MCB SP 6-32 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge.
Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 10 KVAR including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 15 KVAR including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 20 KVAR including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 25 KVAR including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of heavy duty resin filled capacitor 440 volt 3 ph of capacity 30 KVAR including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of APFC Controller for contactor switching with 1 CT input 4 Step including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of APFC Controller for contactor switching with 1 CT input 6 Step including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of CT 200/5A CL1 5VA including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of CT 100/5A CL1 5VA including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of digital VAF & PF meter CL1 including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 10 KVAr capacitor bank including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 15 K VAr capacitor bank including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 20 KVAr capacitor bank including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 25 KVAr capacitor bank including connections and testing for proper functioning complete all as specified and directed.
Taking down and Supply and fix in repair / replacement of Capacity duty contactors 440 V, 3Ph, 50 Hz suitable for 30 KVAr capacitor bank including connections and testing for proper functioning complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 25 X 4 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 5 of SSR Part I of 2009 & as specified or indicated and testing on completion including excavation/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab cover 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade, including galvanised iron strip 25X4 mm with GI protection pipe of 40 mm medium grade up to 7.5 meter length, etc complete all as specified.
M& L for testing of APFC panel for proper functioning in manual & auto mode, including re-wiring the burnt out wires, replacing the wiring ducts/casing capping, fuse units and cleaning and testing complete all as specified and directed by Engr-In-Charge.
Preventive Maintenance and Servicing of Servo Voltage Stabilizer, Oil Cooled & Indoor type of Capacity 10 to 75 KVA, 415 Volts, 50 Hz, AC Supply by disconnecting carefully its electric cable connection on primary & secondary side, Checking both side bushing, bus bar connections, opening top cover of the Voltage Stabilizer by unscrewing its nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any, during servicing and re-fixing the top cover of voltage stabilizer according to previous system. Servicing of the Servo Voltage Stabilizer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each Servo Voltage Stabilizer to the Engr-in-Charge. Note 1. :- Inspection of Servo Voltage Stabilizer shall involve :- (a) Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b) Checking all brazings, joints, tap heads, gaskets and connection joints etc. (c) Checking all terminations / connections inside Voltage Stabilizer. (d) Checking moving and fixed contacts for contact wear and connection to winding etc. (e) Conducting the test on dimmer/windings as per relavent IS like, short circuit, IR Value and Voltage regulation test etc. in presence of Engr-in-Charge. Note 2. : The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement without any extra cost to the department.
All as per item No. 67 above but capacity 100 to 200 KVA,
All as per item No. 67 above but of capacity 400 to 630 KVA,
S & F in replacement Sensing Control Card, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 10 to 75 KVA complete all as specified and directed.
All as per item No. 70 above but capacity 100 to 200 KVA.
All as per item No. 70 above but capacity 400 to 630 KVA.
S & F in replacement Servo Motor, 1-ph, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 10 to 75 KVA complete all as specified and directed.
All as per item No. 73 above but capacity 100 to 200 KVA.
All as per item No. 73 above but capacity 630 KVA.
All as per item No. 76 above but capacity 100 to 200 KVA.
All as per item No. 76 above but capacity 400 to 630 KVA.
S & F in replacement Volt Meter, analog type, range from 0 to 260 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type, of capacity 10 to 75 KVA.
All as per item No. 79 above but capacity 100 to 200 KVA.
All as per item No. 79 above but capacity 400 to 630 KVA.
S & F in replacement Volt Meter, analog type, range from 0 to 660 Volts, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 10 to 75 KVA.complete all as specified and directed
All as per item No. 82 above but capacity 100 to 200 KVA.
All as per item No. 82 above but capacity 630 KVA.
S & F in replacement control wiring of 1.5 Sqmm single core multi-stranded FRLS copper conductor insulated with heat shrinkable PVC sleeve tagged and secured for indicators / meters/Voltage Stabilizers etc including suitable size of copper lugs, PVC cable ducts, galvanised or cadmium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply and top up of voltage stabilizer oil with di-electric strength not less than 50 KV in to the body tank of the voltage stabilizer at various locations complete all as directed by the Engineer-in-Charge and also submit the test result before and after the top up.
S & F in replacement ampere meter including suitable size of CTs, ring type, 240 Volts, 50 Hz, AC, suitable /compatible to existing Servo Voltage Stabilizer, Oil Cooled type of capacity 10 to 75 KVA.complete all as specified and directed
All as per item No. 87 above but capacity 100 to 200 KVA.
All as per item No. 87 above but capacity 400 to 630 KVA.
Supply and re-winding Super enamelled Copper winding wire as per sample given or suitable / compatible to existing servo voltage stabilizer, Oil Cooled type of any capacity/ make and re-winding the defective coils/dimmer assembly with new copper wire as per relevant I.S. of same gauge and existing size together with new insulated materials/ bracings before placing in to the voltage stabilizer and assembling the coil with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed
M & L for replacement Super enamelled Iron core as per sample or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective iron core with new iron core as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the iron core with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed
M & L for re-insulation/re-varnishing of super enamelled copper winding wire of existing copper winding/dimmer stat assembly or suitable/compatible to existing Servo voltage stabilizer, Oil Cooled type of any capacity/make by re-assembling the defective Copper winding with new copper winding as per relevant I.S. of same gauge and existing size together with new materials/ bracings before placing in to the voltage stabilizer and assembling the Copper winding/dimmer stat assembly with new insulation and fitting the coils in the chamber, testing and commissioning the voltage stabilizer and recording the test results complete all as specified and directed
M & L for dehydration/filteration of voltage stabilizer oil at site by taking proper shutdown of various capacity of Voltages Stabilizers located at various Sub Stations inside Air Force Stn Pune, desired di-electric strength of oil not less then 50 KV complete all as directed and specified and also submit the test result before and after the de-hydration of the stabilizer oil complete all as specified and directed.
Preventive Maintenance and servicing by opening the top cover of the Voltage stabilizer, air cooled type, capacity 10 to 75 KVA, 415 Volts, 50 Hz, AC and checking the all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing, \Minor patrs etc complete all as specified and directed. Note : Servicing must be done through OEM or authorised personnel.
All as per item No. 94 above but capacity 100 to 200 KVA.
All as per item No. 94 above but capacity 400 to 630 KVA.
Preventive Maintenance and servicing by opening the top cover of the Isolation Transformer, Oil Cooled type, Capacity 10 KVA to 75 KVA, 415 Volts, 50 Hz, Checking all control wiring and cleaning internally by applying air pressure through blower and ensure testing voltage, current, Earthing etc complete all as specified and directed. Note : Servicing must be done through OEM or authorised personnel.
All as per item No. 97 above but capacity 100 to 200 KVA.
All as per item No. 97 above but capacity 400 to 630 KVA.
M&L for PCC 1:4:8 for area around existing panel including necessary foam work, curing
Taking out the submersible pump/Openwell Submersible Pump set for repairs and lowering down after repairs the submersible pump set of any capacity & of any type from the bore well to a depth of not exc. 70 mtrs including scrapping of the existing paint of submersible pump set and applying two coats of anti corrosive paint over a coat of primer complete after repair / replacement of spares and commisssioning all as directed by Engr-in-Charge. [NOTE: COST OF REPAIR SHALL BE MEASURED AND PAID AGAINST RELEVANT ITEM]
Repairs to submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of thrust plate,CI bowl,pump shaft,impeller ,Bearing,strainer,bush cable gaurd etc. reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
Repairs to Non clog ,Open well submersible Pump set of electric driven of any type make and capacity upto 5 HP incl rewinding of the motor with same gauge and weight of PVC insulated copper conductor incl renewal of Mechanical seal, Bearing ,thrust plate,CI bowl,pump shaft,impeller ,strainer,bush cable gaurd etc. reassembling, testing and commissioning complete all as directed by Engr-in-Charge.
Replacement of unserviceable PVC weather proof cable and replacement with new PVC weather proof copper cable for size 3 core 2.5 sqmm suitable for submersible pump set complete all as directed by Engr-in-Charge.
Taking out old unserviceable MCCB 200 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,200 Amps all as directed.
Taking out old unserviceable MCCB 100 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,100 Amps.
Taking out old unserviceable MCCB 63 Amps and replacing the same with new MCCB 415 V,25 KA ,4 Pole ,63 Amps.
Material and labour for reparing/maintenance of existing electrical panel boards of pump sets by replaing worn out spares as starter/single phase preventor/ relay /contactors MCCB's / MCB's / switch gear / cable glands/ lugs pin type, U type etc, cleaning of panel board, tightening of cable connection to avoid sparking, insulating bus bars bracket portion of conductor and to ensuring proper function of the panel board all as directed by Eng-in-Charge. NOTE: ( I ) Cost of spares as starter /single phase preventor/voltmeter/Amp meter/ relay / contactor /MCCB's/ MCB's / Switch gear / cable gland etc shall be measured and paid against relevant item. (ii) Cost of lugs (pin type / U Type) ,insulation taps shall be included in quoted rate. (iii) Cost of fixing of spares shall deemed to be included in quoted rate.
Renewals/replacing the following spares to the existing elecrical panels complete all as directed by Engr-in-Charge.
Supply Voltmeter/Ammeter ,3 phase for range 0-200A Class-I, suitable as per existing
Supply only contractor of capacity upto 45 A,power operating voltage 415 V AC Capacity 3 pole with AC coil etc (Make: L & T,TC)
Supply only Over load relay with range 16 to 45 A (Make: L & T)
Dismantling the centrifugal Pump/motor capacity Upto 3HP including disconnecting suction and delivery etc and reassembling same after replacement of necessary spares including greasing and painting of 2 coats of synthetic enamel paint using spray machine complete all as specified and as directed by Engr in charge. NOTE: 1.In case of Centrifugal pump dismantling of pump and motor will be paid seperatly. 2. In case of Monoblock pumpset pump/motor paid as one
All as per item no 111 above but for the capacity of 5 HP to 7.5 HP
All as per item no 111 above but for the capacity of 40HP to 50HP.
All as per item no 111 above but for the capacity of 60HP to 75 HP
Supply the following worn out spares of Centrifugal/monoblock pump sets.
Bearing as per existing Size suitable for 5HP to 7.5 HP motor
Bearing as per existing Size suitable for 40HP to 50 HP motor
Rubber bush/star rubber for coupling as per existing size for upto 50HP motor
Gland packing for 40 HP motor
Gland packing for 50 HP motor
Supply and replace old worn out couling with new Tyre coupling including machining,suitable to shaft dia of pump and motor of 30HP,40HP,50HP
Overhauling/servicing of Suction sweeper assembly trolley mounted with mud pump motor head 11.5 mtr make; Kirloskar for swimming pool complete all as specified and directer by Engr-in-charge. Notes:- including spares require for making the assembly serviceable deemed to be included in subjected item.
Rewinding of electric motor 3 phase, 415 Volt capacity 1/2HP TO 3 HP, incoming disconnection electric connections, dismantling slots, taking out burnt windings and rewinding the motor with super enameled copper wire as per existing size including insulating material and varnishing,greasing, painting with super enameled paint as per colour coad assembling the motor after rewinding and mounting at its own position, replacing the old nut, bolts and testing all as directed.
All as per item no.118 but for the capacity of 5HP.
All as per item no. 118 but for the capacity of 40HP
All as per item no. 118 but for the capacity of 50HP
Taking out unserviceable foot valve 80 mm dia from the UG sump and S & F new foot valve 80 mm dia ball type incl rubber gasket, bolts, buts complete all as directed.
Supply and replacing Automatic DOL starter suitable up to 5 HP submersible/ centrifugal pump set
Supply and replacing Automatic star Delta starter suitable 7.5 HP to 12.5 HP submersible/ centrifugal pump set (Make : as Per existing Make)
Replacement of nuts bolts to top & bottom cover of DSM pump 100 HP, 90 HP, 75 HP.
Supply & fixing in replacement LT cable 1100 volts grade PVC insulated multistranded copper conductor cable single core of size 35 sqmm. Make :- Polycab/Havells/Finolex
M&L for cleaning and sterilization of inside the RCC/ Steel Underground/semi underground/Over head/Sedmentation/clear water sumps of capacity. (a). First Stage is to drain out the water by using exit valve or high capacity dewatering system. (b). Second stage is cleaning all the algae formation inside the tank . (c). Third strage is fresh water cleaning by high speed jet pump. (d). Fourth stage and first bacteria screening is decertification. (e). Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner. (f) . Sixth stage is the second bacterio screening and sterilizing method by using ultra violet ray within the tnk and kills all suspended bacteria. (g) Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent. NOTE:-(i) COMPANY WILL SUBMIT LABORATORY TEST CERTIFICATE OF CHEMICAL USED BEFORE CLEANING, FIX THE STICKER MENTIONING THE DATE OF CLEANING & NAME OF SITE AND ALSO PROVIDE CERTIFICATE CONFIRMING THE COMPLETION OF STERILIZATION OF WATER TANKS MENTIONING THE NAME OF STATION AND DATE OF CLEANING. ALL THE CLEANING & STERILIZATION STAFFS SHOULD BE UNDER ACCIDENTAL INSURANCE COVERAGE. (ii) OUTLET PIPE OF OHT SHOULD BE PLUGGED BEFORE CLEANING THE OHT TO AVOID.ENTERING SCALS AND THE SAME SHELL BE RECONNECTED AFTER CLEANING THE OHT AND THE QUOTED RATE IS DEEMED TO INCLUDE FOR THE ROVISION . (III) STERILIZATION TEAM WILL BE COMPRISED OF AT LEAST 30% MEMBERS WHO ARE MINIMUM 03 MONTHS CERTIFICATE HOLDER IN WATER TANKS STERILIZATION. (IV) CONTRACTOR WILL BE RESPONSIBLE FOR RECTIFICATION OF COMPLAINTS OCCURRED DURING CLEANING THE TANK IE. NO WATER IN TANK/OVER FLOW DUE TO BROKEN OF FLOAT VALVE/ BLOCKAGE TO BE INCLUDED IN QUOTED RATE. NOTE:-THE WORK SHALL BE CARRIED THROUGH SPECILIZED AGENCY.
All as per Item no.127 but for UG sump 50000/30000 gallons capacity
All as per Item no. 127 but for O H Reservoir 50000 glns capacity
All as per Item no. 127 but for O H Reservoir 25000 glns capacity
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity up to 10000 Glns complete all as specified and directed by Engr-in-charge
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 10001 to 15000 Glns complete all as specified and directed by Engr-in-charge
Cleaning fire static tank for fire fighting system drain out of water and taking out the sludges from the bottom of the static tank and clean surface by scraping and two coats of white cement wash of capacity 15001 to 25000 Glns complete all as specified and directed by Engr-in-charge
Material & Labour for painting of Pumps inlcuding motor of capacity upto 12.5 HP
Material & Labour for painting of Pumps including motor of capacity upto 50 HP
Material & Labour for painting of Pumps including motor of capacity upto 100 HP
Taking up cast iron water mains with fittings ( including dewatering of trench) with spigot and socket ends and lead joint including burning out joints and recovering lead.
100 mm bore
150 mm bore
Caulking existing leaking lead joint including jointing materials such as lead, lead wool, spurn yarn for the following sizes of CI pipe lines complete all as directed.
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M & L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe upto 150 mm bore.
M & L bends (any type, radius and angle) tapers any type (straight bend, increasing, decreasing or double socked etc) tee pieces , single branch, junction, double branch, cross ( all sockets or socket and spigot) collars, caps plugs suitable for the pipe 200 mm to 300 mm bore.
Taking down and S&F PVC Float valves , high pressure ,with polythene float and flynut complete ,screwed for iron pipe of size:
15 mm dia
20 mm dia
25 mm dia
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil for cleaning surface area and cutting shurbes/grass & bushes and remove the material at various installation at site. all as directed by Engr-in-charge.
Demolishing or dismantling Concrete in ground floors and pavings n exc 15 cm thickness
Cement concrete in foundations, filling and mass concrete(1:2:4)
M&L for Construction of brick masonry valve pit inside measurement 1.2 m x 1.2 m x 90 cm in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 200 mm to 300mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement all as directed by Engr in charge.
M&L for Construction of brick masonry valve pit inside measurement 0.90m x 0.90m x 0.90m in replacement complete with MS Sheet 3.00 mm thick cover and angle iron frame (40m x 40mmx 40mm) as per existing size including locking arrangement suitable for sluice valve 80 mm to 150 mm and sheet cover with one coat of red oxide and two coat of Synthetic enamel paint and complete leveling refilling the unwanted existing trenches ,as per ground requirement all as directed by Engr in charge
M & L for Mechanical Joint clamp of (minimum thickness of 6mm) type,flap type,GP joint, Mundi Type or as per site requirement for CI,DI Pipe of size 80mm along with MS nut bolt washer
M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type or as per site requirement for CI,DI Pipe of size 100mm along with MS nut bolt washer
M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type or as per site requirement for CI,DI Pipe of size 150mm along with MS nut bolt washer
M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundi type or as per site requirement for CI,DI Pipe of size 200mm along with MS nut bolt washer
M & L for Mechanical Joint clamp (minimum thickness of 6mm) type,flap type,GP joint type, Mundii type or as per site requirement for CI,DI Pipe of size 250mm along with MS nut bolt washer
M & L DI water pipes with spigot and socket ends including rubber gasket joint Class K9, in any length, laid in trenches.
100 mm bore
150 mm bore
Taking out and S&F unserviceable CI sluice valve from exisiting position by opening the nuts , bolts and breaking of valve chamber including necessary earth work and excvation in any type of soil and S & F CI sluice valve with PN rating 1:6 conforming to IS 14846 duly ISI marked with iron wheel head HSS spindle and all other conected accessories such as gland packing, bolts, and nuts rubber gasket etc complete and making good the vlave chamber to match with the adjacent surface including brick / PCC block works, plastering etc for the following sizes complete all as directed .
100 mm bore
150 mm bore
Servicing and Maintenance of Dry air compressor by OEM or as directed by Engineer in charge . Make:- ELGI22,Model EG22 Notes :- servicing includes deep cleaning of equipment checking of electrical connection ,change of Oil and cupling connection,change all the parts as per OEM recommended 4000hrs kit.
Replacement of pre Filter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125
Replacement of Fine Filter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125
Replacement of Carbon Filter having flow rate 125 CFM as directed by Engineer in charge. Make :- ELGI22,Model 125
Servicing and Maintenance of Laminar Cum Fume hood big size by OEM or as directed by Engineer in charge.Make :- Spire Automation and inovation india Model :- SAH-FH-14-Big Notes :- Testing certificates need to be furnished by the contractor.
Servicing and Maintenance of Horizontal laminar flow cabinet or as directed by Engineer in charge. Make :- Spire Automation and inovation india,Model :- H-11 Notes :- Testing certificates need to be furnished by the contractor.
Shriyansh sales and services (BID ID -3249179)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .