| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹46.0 L+₹1.7 L (3.94%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹46.2 L+₹2.0 L (4.54%)Rejected-AOC 1 2 GR FLOOR VITHALKUNJ NO 3 V P ROAD ANDHERI WEST MUMBAI 400 058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹46.3 L+₹2.1 L (4.66%)Rejected-AOC GALA NO 08 D SOUZA SADAN OPP ANULAXMI ART PRINTERS NEAR GANESH MANDIR LOKMANAYA TILAK NAGAR A G LINK ROAD SAKINAKA MUMBAI 400 072 | MUMBAI SUBURBAN | MAHARASHTRA | 400072 | L4 | Rejected-AOC REJECTED | |
| 5 | L5₹47.2 L+₹2.9 L (6.63%)Rejected-AOC | L5 | Rejected-AOC REJECTED |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
DAY TO DAY /PETTY REPAIRS TO MISC B/R AND E/M ITEMS INCL PERIODICAL SERVICES IN DEPOT AREA AND MES INSTALLATION AT MO MB GHATKOPAR
2020_MES_378838_2
8861/B
Open Tender
Civil Works
Item Rate
274 days
GHATKOPAR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹90,000
Yes
29 Jan 2021
3 Nov 2020
19 Nov 2020
3 Nov 2020
17 Nov 2020
10 Nov 2020
60 days
Amount
Demolition of brick work or stone boulder masonry,built in cement mortar or cement lime mortar including all quoins, arches, pillars etc, but excluding ashlar facings, dressed stone work and precast concrete articles.complete all as specifed and directed
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
All as per item No 02.00 here-in-before but except stones complete all as specified and directed. Note- Serviceable stones obtained vide item No 01 shall be reused after removing mortar and cleaning with water complete all as specifed and directed. .
M&L for brick work with sub class B bricks straight or curved on plan exceeding 6 m mean radius built in CM 1:6 complete all as specifed and directed
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc complete all as specifed and directed.
M & L for rendering 12 mm thick in CM 1:6 on brick walls or concrete surfaces and finishing the surfaces even and smooth complete all as specified and directed.
M/L for 15mm thick rendering(first coat) in CM 1:4 on external surface of wall mixed with water proofing compound and shall be scored to provide key for rough finishing coat. including necessary scaffoldings etc complete all as specified and directed Note:- WPC shall be measured and paid seperately.
Supply only integral water proofing compound.
M & L for rendering 5 mm thick in CM 1:3 on concrete surfaces as in ceiling and finishing the surfaces even and smooth with sagol finish complete all as specified and directed.
M&L for Extra over stone walling for hammer dressing to face stone and dressing face beds and joints as specified of random rubble walling uncoursed or brought upto courses surface n exc 20 mm complete all as specifed and directed
M&L for 20mm thick rendering in CM 1:4 on stone masonry surfaces finishing the surface even and smooth without using extra cement complete all as specifed and directed
M&L for preparation of new plastered surfaces of wall and applying three coats of white wash complete all as specified and directed
Demolition of concrete in ground floors (un re-inforced) and paving n.exc. 15 cm thickness (below or above ground level) and removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
Demolition of RCC of any description and in any position not otherwise specifically provided rainforced (reinforcement of cut as required to facilasite demolition etc) including removal of demolished materials out side of MD land complete all as specifed and directed.
M&L for pre cast reinforced cement concrete 1:2:4 type B1 (using 20mm graded stone aggregate) as in landing, manhole covers etc including necessary form work for fair finished surfaces complete all as specifed and directed.
S & F mild steel TMT bars 10 mm dia over, cut to length, bent to shape required including crancking bending spirally for hooping for col hooking ends and binding with and including mile steel wire non less than 0.9 mm dia securing with clips in quality complete all as specifed and directed.
All as per item No 16 here-in-before but 6 to 8mm dia quality confirming complete all as spd and directed.
M&L for providing factory made RCC precast cement concrete grade M-30 cover slab of size 450mmx900mmx75mm thick size set in cement mortar 1:6 including reinforcement of 8mm dia deformed bars @150mm c/c both ways etc, complete all as specified and directed.
M&L for providing factory made RCC precast cement concrete grade M-30 cover slab of size 600mmx900mmx75mm thick size set in cement mortar 1:6 including reinforcement of 8mm dia deformed bars @150mm c/c both ways etc, complete all as specified and directed.
M&L for cement concrete type D-2 1:4:8 using 40 mm graded stone aggregate in filling foundation , sub base of floor and mass concrete complete all as specifed and directed
M&L for cement concrete type B-1, 1:2:4 ( 20mm graded aggregate ) as in surface channels and drains etc complete all as specified
M&L for providing plain cement concrete 1:2:4 type B-1using 20mm graded stone aggregate as in kerb stone, coping including framed work for man holes etc including weathering ,slightly rounded or chamfered angle and throating as directed including necessary form work complete all as specifed and directed
M&L 75 mm thick cement concrete type C-1, 1:3:6 (20 mm graded stone aggregate) as in path/plinth protection complete all as spd and directed.
M&L for 100mm thick cement concrete type B-1 1:2:4 using 20mm graded stone aggregate in flooring finishes the surfaces even and smooth without using extra cement etc complete all as pecified and directed.
M&L for chequered cement concrete tiles 25cmX25cmX22mm thick,set jointed in neat cement slurry in floors with grey cement and pigments and including over 20mm thick screed bed in CM 1:4 etc and as complete all as specified and directed
M&L for forming 20mm thick expansion joint filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' complete all as specified and directed
Dismantling of MS works of any description such as ,ladders,gates work,grating etc, including necessary straightening of bends complete all as specified and directed.
S&F Mild steel work of Angles, bars, flats etc., as in supports for fencing, wall ties, mild steel frame work for bird proofing fixing of XPM jalli, (Beam, Angle, Channel, Plates or flat section etc), distance pieces, cleats, bracing, etc, of grade E-250, Fe-410W, quality 'B' including welding, complete all as specified and directed.
S & F in repairs razor type concertina coil, 9 SWG hot galvanised spring tensile wire, 145 to 150 newton per square mm, zinc coating 250-300 gram per square meter, dia of coil when unstretched 610 mm, minimum number of coils 10 per running meter after laying, hot dip galvanised razor ribbon tape of size 0.50 mm thick, 19 mm wide before wrapping central core wire, fixed with 1.66 mm thick GI clips 25 Nos per running metre and special nut bolts, hold 'Z' coils together and extra barbered wire four rows parallel wire of 10 gauge complete all as specified and directed.
S&F in repairs galvanised two strand steel barbed wire, 2.24 mm dia, barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including making holes in rail/angle, securing or tying at crossing with and provisions of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed Note - Each line shall be measured and paid for separately.
Taking down chowkat or frame with shutter (without taking off shutter from the frames) and including grills/ guard bars not exceeding 1.5 Sqm each complete as directed
S&F aluminium section in doors / windows /ventilators sliding or openable or any type , powder coated in colour (Thickness of powder coating not less than 50 micron)(medium weight of series 'B') or as section directed by Engineer-in-Charge, cut to size, jointed together with cadmium plated steel screws including necessary pvc or rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet and all necessary fittings complete, screws, lock,plugs for fixing screws, etc all as specified and directed (Make : JINDAL/HINDALCO) Notes :- (a)Weight of aluminium sections shall only be measured. (b) The rate quoted shall be deemed to inclusive of necessary rubber breading, track pvc or gasket for aluminium sections for fixing glass / bakelite sheet
S&F aluminium anodised grill DG- 202 ( 10 mm x 5.2mm ) of Deco grill or equivalent fixed with 'F' section size not less than 20.60 x 15.20 x 1.5mm thick of approved make all as specified and directed.
M&L for removal of loose and disintegrated concrete of RCC structural members viz slab, beam, column and lintel etc by low impact hammer including removal of debris outside MD land. Cleaning of exposed reinforcement bars with wire brush and apply two coats of anti-rust protective chemical at suitable intervals all as per manufacturer's instructions to resist further deteoration of reinforcement bars. Apply approved epoxy based bonding coat on concrete surfaces to achieve sound bond between existing and new concrete. M&L for profilling of structural members with polymer modified mortar 1:3 mixed with and including 15% latex polymer by weight of cement (w/c ratio 0.35) including leveling to match the surface. Application of complete treatment shall be through approved applicator all as per manufacturers instructions (Bauchemic Krishna or Sunanda) including scaffolding for following 20mm average thickness of polymer modified mortar complete all as specified and directed
M&L for filling cracks with polymer based chemical (Dr fixit cracks shrink free or equivalent) for cracks not exc 10 mm in width as per manufacturer instruction on wall surfaces on concrete or masonary including scaffolding etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying Two coat of oil bound distemper including application of white cement based wall care putty finish (3mm thick) for smooth finish.etc complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of old decorated surfaces of ceiling brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying one coat of white wash complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller Two coat of oil bound distemper including application of white cement based wall care putty finish (3mm thick) for smooth finish.etc complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and thereafter applying with roller one coat of oil bound distemper including wherever necessary filling of nail holes/ inequalities with Putty for smooth finish.etc complete all as specified and directed.
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old decorated steel surfaces such as truss , purline etc height of the structuers exc 5 mtr of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.Note; .
M/L for preparation of new plastered surface of walls and applying 100% anti-fungal acrylic paint over a coat of acrylic primer complete.
M&L for preparation of old decorated surfaces of wall,compound wall, brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and treating oil and greasy spots and thereafter applying one coat of colour wash complete all as specified and directed.
Hacking out old brocken glass (any thickness, size, quality or description) from wooden frame or stone, concrete or brick surrounding, glazed with putty or fixed with beads.
M&L for 4.0mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane.
S &F, in repairs, aluminium alloy wire cloth, 0.45 mm nominal dia of wire and average width of aperture 1.40mm and fixed with in wooden windows, doors etc,and fixing of teak wooden beeding complete all as specified and as directed by the Engineer in charge.
M&L for 20 to 25mm machine cut pre polished kota stone slab for steps in single piece with round nosing with three numbers of serration as in treads of steps for staircase, cill of windows laid over cement screed bed or plastering and jointed with grey cement slurry mixed with pigment to match the shade of of the slab including rubbing and including over 15mm thick screed bed or bedding layer in CM1:4 complete all as specified and as directed.
M&L machine cut pre polished kota stone slab 20 - 25mm thick over 15mm cement screed in CM 1:4 as in window cill and jamb in single piece laid and jointed with gray cement slurry mixed with pigment to match to the shade of the slab complete all as specified and directed .
M&L for 20 to 25mm thick machine cut and machine polished cudappa stone slab for kitchen plateform jointed and set in CM 1:3 and fi fixed including rounding to edge of stone slabs one side edge etc complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding removing serviceable tiles and rubbish off the premises etcand removal of rubbish/ demolished materials out of MD land complete all as specified and directed.
M/L for Non-skid ceramic tiles (Coloured) 300x300 mmx 7mm thick in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300x200mmx7mm thick in vertical surfaces such as skirting/dado and risers to steps and including over 10mm thick rendering in CM 1:4 on fair faces of brick/concrete surfaces as in backing coat for tiles. etc, all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in floors etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 laying floor finishesed complete all as specified and directed.
M&L for vertified ceramic tiles 10mm (light shade of square/ rectangular) polished, area of each tiles not exc 0.36 sqm in skirting etc,.set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering CM 1:6 laying floor finishesed complete all as specified and directed.
S&F CI floor trap 75mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & taking down old trap complete all as specified and as directed.
S&F CI floor trap 100mm dia outlet, with CP grating including jointing to waste pipe, fixed in cement concrete type B1 (1:2:4) & including taking down old trap complete all as specified and as directed.
S&Fin repair wash down water closet (pedestal pattern) white and including plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging device (excluding flushing cistern ) etc complete all as specified and directed..
S&F in repairs vitreous china squatting pan, white, orissa pattern pan of size 580 mm x 440 mm of standard quality with integral foot rests,and including 'P' trap or 'S' Trap complete including connection to trap and to flushing pipe, anti syphonic pipe etc., complete all as specifiedand directed.
S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar taps chromium plated fancy type etc complete all as specified and directed.
Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
S&F in repairs CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs CP long nose bib tap 15mm bore fancy type with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S&Fin repair 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
S&F in repair low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
S&F in repair brass chromium plated towel rail 20mm dia 'D' type 600mm long between flanges, Cat No BA -01 of with and including chromium plated brass screws etc complete all as specified and directed. Make:Prayag polymers Pvt Ltd or equivalent
Taking up or down steel tubing and connection, removing clear off site after credit for the same is recovered by the dept., bore of pipe 15mm complete all as specified and directed.
Cutting and grooving of wall for fixing of GI pipe lines and after fixing of GI pipe line and making good of all cutting surfaces
S&F 15mm bore U- PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc. with all fittings completed all as specifiec and directed.
S&F in repairs 1000 ltrs Rotational mould polyethylene water storage tanks (cylinderical vertical with closed top) hoisted and fixed in position all as specified in ssr part-I complete all as specified and directed
S&F in repair 25mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe 20 mm dia (minimum weight - 210 gm) complete all as specified and directed.
Dismantling of ceiling board (fibre, pulp,insulation etc) or insulation boards/slabs/blankets any thickness, including cover fillets etc complete all as specified and directed.
M & L for false ceiling of galvanised iron frame work of angle section of 15 x 15 x 28 gauge for support and main U section of 40 x 20 x 26 Gauge and supporting U clip of 32 x 18 x 26 Gauge and gypsum board of 12.5 mm thick in panels fixed to GI frame work including cutting, bolting, welding etc of GI frame work and providing POP finish to the ceiling and applying two coat of OBD complete all as to the satisfaction of Engr - in - Charge
Taking down carefully copper/aluminum point wiring of any type such as concealed/surface/batten/casing and capping (light fan, socket or power) complete including fitting such as switches, ceiling roses, pendants, lamp/bracket holders, sketch/bulk head fittings, regulators, sockets, board outlets etc and making good the disturbed surfaces of walls, floor, ceiling etc for rewiring and repairs etc.
Taking down main switches DBs with sheet metal enclosure 2/4/6/8 way SPN/TPN/DBs etc all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including stove enamelled steel conduit ISI marked not less than 20/25 mm dia surface on wall,ceiling with GI saddles, GI screws rawl plug (surface conduit wiring) with all fittings including tee,junction boxes PVC connector and provision of modular pressed steel terminal box of suitable size with inner and outer plates of mounting switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 79 here-in-before but one 5 Amps switch socket on same board all as specified and directed.
All as per item No 79 here-in-before but one 5 Amps switch socket on indipendent board all as specified and directed.
All as per item No 79 here-in-before but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
M&L for point wiring light point/Ceiling/Exhaust fan point/ bell point with single core PVC insulated unsheathed 1100 volts grade FRLS cable with multi stranded copper conductor of size 1.5 Sqmm (nominal area) drawn through in and including non metallic PVC casing caping ISI marked not less than 20/25 mm dia surface on wall,ceiling with all fittings including tee,junction boxes PVC connector and provision of Modular steel terminal box of suitable size with inner and outer platesmounting of switch socket and regulators and drawing continuous earth wire of FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 1.5 Sqmm (nominal area) complete all as specified Note: colour coding should be maintained (PH:Red Neutral:Black, Half:Yellow Earth:Green)
All as per item No 83 here-in-before but one 5 Amps switch socket combination on independent board all as specified and directed.
All as per item No 83 here-in-before but one 5 Amps switch socket combination on same board all as specified and directed.
All as per item No 83 here-in-before but for 3 pin socket outlet 15 Amps independent with cable 2.5 sqmm unsheathed stranded 1100 volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly all as specified and directed.
Material and labour in repairs for point wiring complete with 4 sqmm PVC insulated unsheathed 1100 volts grade cable stranded copper conductor single core drawn through and including surfaced on rigid PVC conduit and conduit accessories of 20/25 mm complete with modular steel terminal box concealed in wall with inner and outer plates for fitting/ mounting switch/ sockets regulators etc with laminated sheet 3 mm thick cover and with 4 sqmm PVC insulated copper conductor earth wire and connected to earth dolly for one15 Amp socket point for connecting water coolers/ AC.
Supply and fix in repairs switch modular type 6 Amp one way, 1 module complete
Supply and fix in repairs switch modular type 16 Amp one way, 1 module complete
Supply and fix in repairs socket modular type 2/3 pin combined 6 Amp 2 module type complete all as specified and directed.
Supply and fix in repairs socket modular type 3 pin combined 6/16 Amp 2 module type complete all as specified and directed.
Supply and fixing in repairs ceiling fan modular regulator stepped type 120 watts AC 230 V 2 module type complete.
Supply and fix in repairs ceiling rose surface backelite three terminal complete all as specified and directed.
Supply, Lay, Test & Commissioning in repairs cable LT XLPE insulated and screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor, 1100 Volts grade of Size 6 Sqmm, 2 core including excavation returning filling, sand cousing, PCC cable covers complete
Material and Labour for tube light fitting box type with suitable for LED 18 watt tube rod with CRCA sheet powder coated complete with housing and LED rod 18 watt with aluminium heat sink on back of led rod,power factor >0.9,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting and shall be fitted on new plastic square/round block complete all as per specified and directed. Make: Philips/CG/Lucker Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fixing in repairs high bay LED light fittings with highly efficient LED baylight made of pressure die cast aluminium housing extraded aluminium heat sink & enclosed with toughended glass IP 66 of capacity 120W , power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on truss with MS Clamps made out of 25x5mm flat iron with nuts, bolts etc complete painting with two coats synthetic enamel paint over a coat of red oxide complete dismantling existing unserviceable high bay fittings all as specified and directed. Make:philips/Lucker/CG Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fix in repairs LED highbay light fitting with highly effiecient LED bay light with lens made of pressure die cast aluuminium housing & enclosed with toughened glass IP66 of capacity 100 watts power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including aluminium die cast housing and aluminium heat sink on back side of fitting dismantling existing unserviceable 2x40 watts Flu. tube light fitting complete. Make : philips /CG/Lucker Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost.
Supply and fixing highly efficient high power multi LED flood light fitting 100 watts with pressure die cast aluminium housing reflector and enclosed with toughened glass IP66 power factor >0.9 5700K,having inbuilt surge protection device for overvoltage protection with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceiling rose/PVC connector to light fitting, including fixing arrangement on wall etc complete including dismantling of existing unserviceable flood light fittings complete all as specified and directed by Engineer in Charge. Make: Philips/Lucker/CG. Note:1.Contractor shall produce LM79 & LM80 test reports from OEM owned NABL accredited laboratory.Contractor shall also produce certificates for power factor and surge protection from the company at no extra cost. 2.Guarantee period of complete fixture should be minimum 3 years from the date of completion 3.Inspection by company Representative before installation at site at no extra cost.
M&L for submain wiring in and including PVC conduit having thickness 1.8 mm, 20 mm dia with two run of PVC insulated, sheathed multistranded copper conductor of 6 sqmm(FRLS) and one run of PVC insulated, sheathed multistranded copper conductor 6 sqmm (green in color) for earth continuity conductor and connected to common earth dolly with thimble etc, cutting chiseling for concealed piping and making good the disturbed surface area white wash/colour wash to matching with existing colour complete all as specified and directed.. ( Note: Two run of 6 sqmm plus one run 4 sqmm of earth wire will be measured as 1RM) including dismantling of existing unserviceable submain wiring all as specified and directed. Note: colour coding is to be maintained .(Ph-Red, N-Black, Half -Yellow, Earth- Green)
Material and labour for rewinding of stator assembly of exhaust fan/bracket fans/wall mounting fans/pedestal fans 375 to 450mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in positionetc complete all as specified and directed.
Material and labour for rewinding of stator assembly of exhaust fan 600mm sweep after strip opening of motor with proper grade/guage of super enamelled copper wiring incl all insulating materials, re-assembling and replacement of worn out nuts, bolts, rubber bushes, clamps etc complete all as specified and directed by Engr-in-Charge. Note :- Taking down cleaning, greasing and re-fixing in positionetc complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder coated MCCB DB TPN vertical type double door suitable for TP/FP G frame MCCB as incomer 415 V 8 way with 200 Amps rated bus bar din rail neutral link all as specified and directed.Make:Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 8 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 12 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted for MCB DB SPN 4 way double door with din rail and bus bar complete all as specified and directed.
Supply and fix in repairs sheet metal enclosure powder painted MCB DB TPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCB as incomer all as specified and directed.Make:Legrand/Schneider/Siemens
Supply and fix in repairs sheet metal enclosure powder painted MCCB DB TPN 415 Volts 4 way double door vertical type with 200 Amps rated bus bar din rail neutral link with suitable for MCCB as incomer all as specified and directed.Make:Legrand/Schneider/Siemens
Supplying and fixing in repairs MCB TP 63 Amps, 415 volts complete all as specified.Make:Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 6 Amp to 32 Amp breaking capacity 10 KA rating complete all as specified.Make:Legrand/Schneider/Siemens
Supply and fix in repairs MCB SPN 240 Volts 40 Amp to 63 Amp breaking capacity 10 KA rating complete all as specified.Make:Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 5 to 32 Amps breaking capacity 10 KA rating complete all as specified and directed.Make:Legrand/Schneider/Siemens
Supply and fix in repairs MCB SP 240 Volts 40 to 63 Amps breaking capacity 10 KA rating complete all as specified and directed.Make:Legrand/Schneider/Siemens
Supply and fix in repairs MCCB 415 volts 16 KA FP 63 Amps complete all as specified and directed.
Supply and fix in repairs MCCB 415 volts 16 KA FP 100 Amps complete all as specified and directed.
Supply installation, testing and commissioning of FAST ELECTRODE maintenance free Chemical Earthing of Dual Pipe Technology, each of 3 Meter long with Outer Pipe Diameter of 88mm (galvanised for 80-120 micron and wall thickness 1.80mm) and Inner Pipe diameter 48mm (galvanised for 80-120 micron and wall thickness 2.60mm). There shall be terminal of size 75 x 5.20mm for connection with two holes of 14mm diameter. FAST ELECTRODE shall be duly filled with the highly conductive, Non Magnetic, Non Corrosive material and duly sealed at both ends with lead terminal of 75x5.2mm at top. The ELECTRODE shall be of 'make' having approval of CPRI (Central Power Research Institute), Govt of India for a minimum short circuit current of 42 KArms for 1 Second with initial pick of 88.2 KA. The FAST ELECTRODE Earth Enhancing Compound (minimum 25Kg) shall be pored on alround the electrode. The chemical compound to be used shall be as per the manufacturer's instructions of 'Electrode' and as also certified by any BIB (Bureau of Indian Standards) accredited laboratory.Electrode connected to GI earth strip 32 x 6mm by mean of bolts, nuts, check nuts and washer of stainless steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including PCC pit and CI cover etc GI protection pipe of suitable size including testing on completion all as specified and directed.Make : Fast Electrode or equivalent as approved by the GE. Notes:- (i) The contractor shall procure the above materials either directly from the manufacturer(s) or their authorised dealers only and shall produce the original purchase vouchers alongwith original manufacturer's test certificates and other authenticated documents in compliance of the provisions as mentioned in the above item. Also all the requisite testing as specified above, in relevant IS and as directed by the GE shall be got done by the contractor. Cost of all the above elements shall be deemed to be included in the contractor's quoted rates.(ii) Any additional quantity of Earth Enhancing Compound in case required to obtain the desired results, the same also be provided by the contractor without any additional cost to the Govt. and quoted rates of above item shall be deemed to include the above element also.(iii) Necessary earth strip to connect equipment shall also provided by the contractor .
A P ENTERPRISES
Darpan Construction
joshua construction
PANKAJ AND BROTHERS
DWARKESH STRUCT-CON
M/S VISHRANTA CONSTRUCTION
S K ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .