| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.9 LAccepted-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹43.7 L+₹4.4 L (11.1%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹48.2 L+₹8.8 L (22.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹53.2 L+₹13.8 L (35.1%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Enlisted in appropriate Category |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar-414002
Manning and operation of sewage installation under GE (N) Ahmednagar
2021_MES_411614_1
8489 / E8
Open Tender
Miscellaneous Works
Item Rate
335 days
Ahmednagar
Class D Cat d(v)
8 documents required · 8 mandatory
₹500
Yes
Garrison Engineer North Ahmednagar
₹90,000
Yes
10 Jul 2021
12 Jan 2021
3 Feb 2021
12 Jan 2021
1 Feb 2021
27 Jan 2021
60 days
Amount
Note (Applicable for Schedule 'A' Part I Sl Item Nos 02 to 11) : The bidder has to submit an affidavit duly notarised that the rates quoted are above minimum fare wages plus all statutory expenses. This affidavit has to be submitted along with Cover -1 with DD. Otherwise bid will be rejected at technical evaluation stage and if after opening financial bid rates quoted found lower than minimum fare wages plus statutory expenses financial bid will be considered as non bonafide tender and will not be considered for acceptance. The lowest tender among other eligible bidders will be considered as bonafide tender
Out sourcing of manpower for manning and operation of sewage water disposal plant / pump house including operation of sewage pump motor for disposal of sewage collected in wet well for further disposal to sewage pond also includes operation of sluice vlaves, electric motors, starters, checking of electric panel, main CI raiser upto sewage chamber ,operation of DG set installed in pump house by maintaining necessary log book, log sheet for daily operation of electric motor pumps for Pump House No 1 (BTR) comprising of two Pump sets of capacity 10 KW - 01 No by one operator (FGM) for each shift of 08 hours for one shift per day etc complete all as specified and directed.by Engineer-in-Charge Note : Quotated rate includes the following (i) ESIC @ 3.25% (on basic rate) (ii) GST @ 18% (on basic rate + ESIC) (iii) LWC @ 1% (on basic rate + ESIC + GST) (iv) Bonus (if appicable as per existing rules). (v) EPF (if applicable as per existing rules) (vi) Contractos overhead & profit
All as per serial item No 2 (here-in-before) but for Pump House No 3 (SF Qtr Nagarewala Road ) comprising of three Pump sets of capacity 50 HP and DG sets of capacity 125 KVA -01 No by One operator ( FGM) for each shift of 08 hours for two shifts per day
All as per serial item No 2 (here-in-before) but for Pump House No 4 ( Bhingar Nala Road ) comprising of two Pump sets of capacity 50 HP and DG set of capacity 63 KVA - 01 No by One operator (FGM) for each shift of 08 hours for three shifts per day.
All as per serial item No 2 (here-in-before) but for Pump House Map Qtr (AC Depot ) comprising of two submersible Pump sets of capacity 10 HP and DG sets of capacity15 KVA -01 No by One operator (FGM) for each shift of 08 hours for one shift per day.
All as per serial item No 2 (here-in-before) but for Pump House Map Qtr (DMR) comprising of two submersible Pump sets of capacity 10 HP and DG sets of capacity 15 KVA -01 No by One operator ( FGM) for each shift of 08 hours for one shift per day
All as per serial item No 2 (here-in-before) but for Pump House Map Qtr (JK Road) comprising of two submersible Pump sets of capacity 10 HP and DG sets of capacity15 KVA -01 No by One operator (FGM) for each shift of 08 hours for two shifts per day.
All as per serial item No 2 (here-in-before) but for Pump House No 7 (Fariya Bagh) comprising of three Pump sets of capacity 40 HP and DG sets of capacity 100 KVA -01 No by One operator ( FGM) for each shift of 08 hours for two shifts per day.
Out sourcing of manpower for Manning and Operation of pump of capacity 12.5HP (at KK Range & JK Road) & over head reservoirs including operation of sluice valves both for intake and delivery, area wise for the following capacities of over head tanks etc complete all as specified and directed.by Engineer-in-Charge Note : Quotated rate includes the following (i) ESIC @ 3.25% (on basic rate) (ii) GST @ 18% (on basic rate + ESIC) (iii) LWC @ 1% (on basic rate + ESIC + GST) (iv) Bonus (if appicable as per existing rules). (v) EPF (if applicable as per existing rules) (vi) Contractos overhead & profit
(a) OH tank at Dhobi ghat/JK Road (1.0 LG) and Castle road area (0.5 LG) by one operator (FGM) for each shift of 8 hours for two shifts per day.
(b) Pump 12.5 HP & OH tank at K K Range (0.05 LG) upper Camp area by one operator (FGM) for each shift of 8 hours for one shift per day. NOTES FOR SERIAL ITEM NOS 2 to 11 - 1. Each Shift shall be of eight hours, The contractor shall employee one operator per shift. 2. The reliever for weekly / holiday off to be arrangned at contractor cost and no extra payment will be made. 3. Unit rate quoted shall be inclusive of tightening/ replacement of gland packing for pumps, valves to stop leakages for suction and delivery line for trouble free operation of the pump sets. 4. All the machinery / installations installed in the pump houses shall be the responsibility of the contractor for their safe custody. 5. Shift of 08 hrs means 1st shift shall be start from 7.00 am morning. There will not be any interval between the shifts. 6. The person employed should be ITI holder with minimum of 4 years of experience in same nature of work. 7. Contractor shall be solely responsible for any mishappening / accident and loss to life due to negligence of the workmen engaged in the work. Nothing extra / No compensation shall be admissible on this account
8. Keeping the sewage installation / water supply OHTs neat and clean and in presentable conditions 9. Contractor has to provide PVC shoes, Hand gloves uniform by displaying the name of operator the cost of same is deemed to be included in the quoted rates. 10. Duty roster shall be maintained by the contractor. 11. Broom and cleaning material reqd shall be arranged by the contractor at his own cost. 12. The location of operator will be changed as per site requirement if required by the Engr-in-charge. 13. Contractor shall provide Bio-matric instrument for attendence of operators and same shall be removed after certified completion of work. payment will be allowed as per attendance of operator only. 14. The operator will not leave the installation without reliver and installation will not be left unmanned in any case. 15. If contractor fails to deploy the operator or in the absence of operator no payment will be made for the same. Howerever a penalty at double the rate quoted will be recovered from his due payment.
16. Contractor provide Fisrt Aid Box with necessary medicne on every installation like BTR. Nagarwala Road, Bhingar Nala Road, AC Depot, DMR, JK Road Fariabagh, KK Ranges, Dhoboghat 17. The contractor shall make payment to the operator through aadhar link bank account. 18. The rate quoted shall be for each shift. 19. Maintaining record of quantity of water received and delivery to users. 20. Cleaning premises of OHT (05 mtr alround form outeer edge of pillar /column/shaft) value chambers in the premises and adjacent to premises of OHT area including dressing up of OHT area including cutting and removing grass/vegitation etc complete all as specified and directed by Engineer-in-Charge
Repair of burnt out electric motor 0.5 HP Capacity from dry well of sewage installation and transprotation to workshop for replacing damaged parts such as bearings, sleeves etc. and for & including rewinding the electric motor with existing gauge,of super enamelled copper wire including insulating, varnishing, heating, re-assembling & after testing to make it functional complete in its original positions / location all as specified and as directed and directed by Engineer-in-Charge.
Supply and fix in repair cast iron sluice valve class PN-1.0 ISI marked with stainless steel spindle both ends flanged and drilled including nuts, bolts, washers and rubber gasket /packing with hand wheel of suitable size complete all as directed for the size of 150 mm dia sluice valves etc complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs cast iron sluice valve ,80 mm bore , Class PN1, ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts, bolts and washers complete all as specified and as directed by Engineer-in-Charge.
Supply & Fixing in replacement MCCB 100 Amp, 3 pole 50 Hz 415 Volts, with rupturing capacity 25 KA complete all as specified and as directed. Taking up/down unserviceable items is included in quoted rates etc complete all as specified and directed.
All as per srl item No 17 (here-in-before) but 200 Amp 4 pole 50 Hz 415 Volts, with rupturing capacity 35 KA etc complete all as specified and directed.by Engineer-in-Charge
Supply and fixing in replacement of monoblock pump of 0.5 HP for removing of leakage water at wet well etc complete all as specified and directed.by Engineer-in-Charge
Supply and fixing in repair of chain link fencing 4mm thik mild steel wires, mesh, size 50mm of any type of standards, rails, straining bolts, including provission of binding wire etc complete all as specified and directed.by Engineer-in-Charge.
Supply and fixing in replacement street /security light fitting,the lighting luminair 120 watt LED with pressure dia cast aluminium housing ,with heat resistance toughned glass,IP 65 protection fixed on and including GI bracket made out of One mtr long 40 mm dia GI pipe light grade, bent to shape,drilled for holes and fixed to pole by means of flat iron clamps ,02 Nos,of size 40 X 4 mm etc including connecting with 1.50 Sq mm multistranded copper cable etc complete all as specified and directed.by Engineer-in-Charge Make : PHILIPS CG CAT part No BRP409 LED 060 CW HE NR S1 PSU GR or equivalent in makes mentioned in list of makes in Appendix `C'.
Supply and fixing in repairs of Three phase submersible pump relay controllers, 50 Hz suitable for 5 / 7.5 HP pump, Relay range 13-21 Amp and connecting up complete all as specified and as directed.
Dismantling and taking down/out the burnt out electric motor 10 HP Capacity from pump foundation, from well of sewage installation and transprotation to repairing bay / workshop for replacing damaged parts such as bearings, sleeves, bushings etc. and for rewinding the electric motor with existing gauge,of super enamelled copper wire including insulating, varnishing, heating, re-assembling & testing the motor at workshop, shifting to site and refixing to its original/desired position including reconnecting all the electric connections by replacement of bolts, nuts & washers including foundation bolts after testing to make it functional etc complete all as specified and directed.by Engineer-in-Charge NOTE : Spares parts reqd to be replaced such as bearings etc.shall be measured and paid separately
All as per srl item No 23 (here-in-before) but centrifugal motor of 20/30 HP Capacity.
All as per srl item No 23 (here-in-before) but centrifugal motor of 50 HP Capacity.
All as per srl item No 23 hereinbefore but electric motor of 10 HP capacity, submersible KDS type pump set
All as per srl item No 23 above but centrifugal motor of 40 HP capacity
Repairs and Replacement of existing MS steel base of motor pumpset 10/20/30/40/50 HP by Removing and Dismantling PCC base and MS steel channels of motor pumpset from foundation Reconstructing the PCC Foundation as per existing (1:3:6) Type C2 using graded stone aggregates and Replacing the Motorpump set with same MS Steel angular channel,replacement of foundation nut bolts, washers,with accurate realignment of motor with pump to avoid vibration and smooth running of pump on full load,testing and commissioning etc complete all as specified and directed.by Engineer-in-Charge
Supply and fixing in replacement of unserviceable PVC insulated cable 4 Core 16 Sqmm, 1100 Volts grade, heavy duty, multistranded copper conductor for connecting motor to panel board with copper lugs duly encased through and including suitable size PVC pipe fixed to wall / laid in floors, Taking up/down unserviceable items is included in quoted rates etc complete all as specified and directed.by Engineer-in-Charge
All as per item No 29 (here-in-before) but 4 Core 10 Sqmm.
Removing blockage from sewage pumpset by opening pump set completely, sluice valve, taper reducer etc including taking out sewage sludge and suspended materials accumulated at bottom of wet well, of any liquid depth/ capacity by way of any means including desluding foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge mixed material/liquid out side MD land by any means/source and cleaning the wall surfaces of well etc complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs, non return valve, ISI marked confirming to relevent IS of size 150 mm etc complete all as specified and directed.by Engineer-in-Charge
All as per item No 32 (here-in-before) but 200mm dia
Taking up or down cast iron / ductile iron water mains with spigot and socket ends having Flange/ lead / tyton joints including all fittings and burning out joints, removing Flange/lead for 150 bore of pipes from 10 to 30 m Depth etc complete all as specified and directed by Engineer-in-Charge
Supply and laying cast iron / ductile iron pipes with spigot and socket ends centrifugally cast, Class LA / K-9 , in any length, laid in trenches for 150 mm bore pipes along with replacing New Flanges tightening with nut bolts with out any leakages up to 10 to 30 m Depth etc complete all as specified and directed.by Engineer-in-Charge Note: Lead Joints,Flange Joints With ISI marked Flanges ,Tyton joints required are deemed to be included in the quoted rate
Taking up or down GI steel tubing and connections from trenches / walls / floors/from 10 m depth of wet well etc removing from submercible motor by opening nuts, bolts and Flanges cleaning for re-fixing for 80 mm bore pipe etc complete all as specified and directed.by Engineer-in-Charge
Supply and fix 80 mm GI pipe, heavy grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors/from 10 mtr Depth of wel well etc,fixing with 10HP submercible motor with nuts and bolts and along with replacing New Flanges tightening with nut bolts with out any leakages up to 10 to 30 m Depth ensuring without any leakages for 80 mm bore pipe etc complete all as specified and directed.by Engineer-in-Charge. Make:- Swastik/suryaprakash/Jindal
Supply and fixing in replacement ball bearing 6309 suitable for 10 HP motor, etc complete all as specified and directed.by Engineer-in-Charge.
All as per item No 38 (here-in-before) but of 6310 Suitable for 20 HP motor
All as per item No 38 (here-in-before) but of 6311 Suitable for 30 HP motor
All as per item No 38 (here-in-before) but of 6313 Suitable for 50 HP motor.
Material and labour for applying two coats of synthetic enamel pain on Cast iron pipe upto 200 mm dia of Sewage pump house of depth up to 20 metre etc complete all as specified and directed.by Engineer-in-Charge
Routine Maintenance of centrifugal / submercible electric motor 10 HP Capacity from any location pump foundation, from well of sewage installation for replacing damaged parts such as bearings, sleeves, bushings etc. including insulating, varnishing, heating, re-assembling & testing the motor at workshop, shifting to site and refixing to its original/desired position including reconnecting all the electric connections by replacement of bolts, nuts & washers including foundation bolts after testing to make it functional etc complete all as specified and directed.by Engineer-in-Charge Note : Spares parts reqd to be replaced such as sleeves, bushings etc.deemed to be included in rate Quoted & included for Bearings
All as per Sl No 43 (here-in-before) but 20/30 HP capacity Electric motor
All As per Sl No 43 (here-in-before) but 40/50 HP capacity Electric motor
Material and labour for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm bore pipes etc complete all as specified and directed.by Engineer-in-Charge Note : (i) Necessary precautions as well as safety measures shall be taken by the contractor without any extra cost for working in the foul conditions. (ii) The contractor shall be enterily responsible for the lapse mishappening to any of the manpower deployed and / or to other equipment / machinary / material at the site of work during the execution.
An amount of Rs 40,812.00 shall be deducted from BOQ on account of schedule of credit
OM SAI ASSOCIATES
MS. G.A. CONSTRUCTION
Ms. S.K. ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .