Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹26.9 L+₹99,218 (3.83%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L2 | Rejected-Finance Highest bid value | |
| 3 | L3₹27.2 L+₹1.2 L (4.73%)Rejected-Finance | L3 | Rejected-Finance Highest bid value | |
| 4 | L4₹27.5 L+₹1.6 L (5.99%)Rejected-Finance | L4 | Rejected-Finance Highest bid value | |
| 5 | L5₹28.0 L+₹2.1 L (8.01%)Rejected-Finance | L5 | Rejected-Finance Highest bid value |
Tender Value
₹50,000
EMD Value
₹50,000
Closing Date
16 Dec 2019, 6:00 pmClosed
GE (AF) KALAIKUNDA
Garrison Engineer AF Kalaikunda P O Kalaikunda Air Field Dist West Midnapore St West Bengal Pin 721 303
REPAIRS/MAINTANCE OF STANDBY OF DG SETS AT AIR FORCE STATION KALAIKUNDA AND DDK RANGE UNDER GE (AF) KALAIKUNDA .
2019_MES_296870_1
8524/E8
Open Tender
Civil Works
Item Rate
270 days
kalikunda and salua
AS PER NIT / TENDER DOC
8 documents required · 8 mandatory
₹500
GE AF KALAIKUND
₹50,000
Yes
27 Feb 2020
11 Nov 2019
17 Dec 2019
11 Nov 2019
16 Dec 2019
29 Nov 2019
Amount
Service engineer / Labour for carrying out 'B' check Maintenance of DG set of 320/400 KVA capacity after 200-250 Hrs running/after 3 month from last engine oil changed or earlier as directed by Engr- in -charge for the following DG sets of Make:- Greaves Cotton Note:- (I) Maintenance of DG set to be carried out as per manufacturers instructions and by qualified service engineer of DG set service center. (II) Materials/Spare parts/Lub oil required for above 'B' check maintenance shall be measured and paid seperately under relavant items as "Supply only Material":-
All as per Item No 1.00 here-in-before but for 250 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar Bliss/Greaves
All as per Item No 1.00 here-in-before but for 200 KVA DG set complete all as directed by Engg-in-charge. Make : Greaves.
All as per Item No 1.00 here-in-before but for 160 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar Green
All as per Item No 1.00 here-in-before but for 125 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar Bliss/Kirloskar Green.
All as per Item No 1.00 here-in-before but for 100 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar.
All as per Item No 1.00 here-in-before but for 82.5 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar Green
All as per Item No 1.00 here-in-before but for 63 KVA DG set complete all as directed by Engg-in-charge. Make : Ashok Leyland.
All as per Item No 1.00 here-in-before but for 50 KVA DG set complete all as directed by Engg-in-charge. Make : Make: Leyland/Cummins.
All as per Item No 1.00 here-in-before but for 40 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar/Greaves
All as per Item No 1.00 here-in-before but for 30 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar Green
All as per Item No 1.00 here-in-before but for 20 KVA DG set complete all as directed by Engg-in-charge. Make : Kirloskar/Kirloskar Bliss/Kirloskar Green
Supply only of Lubricant Oil of specific grade (20W40 or Eqv.) for carrying out 'B' check maintenance complete all as directed by Engg-in-charge. . Make-Kirloskar/ Servo pride(IOC)/Castrol/Veedol or Equivalent.
Supply only of Coolent of radiator water for carrying out 'B' check maintenance complete all as directed by Engg-in-charge.Make Bharat /Greaves or Equivalent
Supply only of Lubricant Oil filter element with 'O' ring, of make Kirloskar/Kirloskar Green/BOSCH/Greaves for carrying out 'B' check maintenance for the DG set of 320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn complete all as directed by Engg-in-charge. Make:Greaves.
All as per Item No 4.00 here-in-before but for 250 KVA DG set at WSA complete all as directed by Engg-in-charge. Make : Kirloskar Bliss / Greaves
All as per Item No 4.00 here-in-before but for 200 KVA DG set at MAFI PS-II complete all as directed by Engg-in-charge. Make : Greaves.
All as per Item No 4.00 here-in-before but for 160 KVA DG set at ATC and Base Ops complete all as directed by Engg-in-charge. Make : Kirloskar Green
All as per Item No 4.00 here-in-before but for 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House complete all as directed by Engg-in-charge. Make : Kirloskar Bliss/Kirloskar Green.
All as per Item No 4.00 here-in-before but for 100 KVA DG set at WSA(PH-12) complete all as directed by Engg-in-charge. Make : Kirloskar.
All as per Item No 4.00 here-in-before but for 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger complete all as directed by Engg-in-charge. Make :Kirloskar Green
All as per Item No 4.00 here-in-before but for 63 KVA DG set at BSO Yard complete all as directed by Engg-in-charge. Make : Ashok Leyland.
All as per Item No 4.00 here-in-before but for 50 KVA DG Set at Transmitter Bldg complete all as directed by Engg-in-charge. Make : Leyland/Cummins.
All as per Item No 4.00 here-in-before but for 40 KVA DG Set at P.H. No-12(CWE Office) and DDK Range complete all as directed by Engg-in-charge. Make : Kirloskar/Greaves
All as per Item No 4.00 here-in-before but for 30 KVA DG Set at CADF complete all as directed by Engg-in-charge. Make : Kirloskar Green
All as per Item No 4.00 here-in-before but for 20 KVA DG Set at 17 End arrester barrier,DDK Range and ATC complete all as directed by Engg-in-charge. Make : Kirloskar/Kirloskar Bliss/Kirloskar Green
Supply only of Fuel filter element with 'O' ring, for carrying out 'B' check maintenance for the DG set of capacities 320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn complete all as directed by Engg-in-charge. Make:Greaves. as indicated below:-
As per item no 5 here-in-before but for 250 KVA DG set at WSA, complete all as directed by Engr-in-charge. Make: Kirloskar Bliss/Greaves
As per item no 5 here-in-before but for 200 KVA DG set at MAFI PS-II, complete all as directed by Engr-in-charge. Make: Greaves.
As per item no 5 here-in-before but for 160 KVA DG set at ATC and Base Ops, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 5 here-in-before but for 125 KVA DG set at 4AFH and GCA power house,ATC,Auditorium& Power House, complete all as directed by Engr-in-charge. Make : Kirloskar Bliss/Kirloskar Green.
As per item no 5 here-in-before but for 100 KVA DG set at WSA(PH-12), complete all as directed by Engr-in-charge. Make: Kirloskar.
As per item no 5 here-in-before but for 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 5 here-in-before but for 63 KVA DG set at BSO Yard , complete all as directed by Engr-in-charge. Make: Ashok Leyland.
As per item no 5 here-in-before but for 50 KVA DG Set at Transmitter Bldg, complete all as directed by Engr-in-charge. Make: Leyland/Cummins.
As per item no 5 here-in-before but for 40 KVA DG set at P.H. No-12(CWE Office), DDK Range, complete all as directed by Engr-in-charge. Make: Kirloskar.
As per item no 5 here-in-before but for 30 KVA DG Set at CADF, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 5 here-in-before but for 20 KVA DG Set at 17 End arrester barrier,DDK Range and ATC, complete all as directed by Engr-in-charge. Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Supply only of Air filter element and Vaccutator Valve for air cleaner, for carrying out 'B' check maintenance for 320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn complete all as directed by Engr-in-charge. Make: Greaves.
As per item no 6 here-in-before but for 250 KVA DG set at WSA, complete all as directed by Engr-in-charge. Make: Kirloskar Bliss/Greaves
As per item no 6 here-in-before but for 200 KVA DG set at MAFI PS-II , complete all as directed by Engr-in-charge. Make: Greaves
As per item no 6 here-in-before but for 160 KVA DG set at ATC and Base Ops, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 6 here-in-before but for 125 KVA DG set at 4AFH and GCA power house, complete all as directed by Engr-in-charge. Make : Kirloskar Bliss/Kirloskar Green
As per item no 6 here-in-before but for 100 KVA DG set at WSA(PH-12) , complete all as directed by Engr-in-charge. Make: Kirloskar
As per item no 6 here-in-before but for 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 6 here-in-before but for 63 KVA DG set at BSO Yard, complete all as directed by Engr-in-charge. Make: Ashok Leyland
As per item no 6 here-in-before but for 50 KVA DG Set at Transmitter Bldg, complete all as directed by Engr-in-charge. Make: Leyland/Cummins
As per item no 6 here-in-before but for 40 KVA DG Set at P.H. No-12(CWE Office), complete all as directed by Engr-in-charge. Make: Kirloskar
As per item no 6 here-in-before but for 30 KVA DG set at CADF, complete all as directed by Engr-in-charge. Make: Kirloskar Green
As per item no 6 here-in-before but for 20 KVA DG Set at 17 End arrester barrier,DDK Range and ATC, complete all as directed by Engr-in-charge. Make: Kirloskar/Kirloskar Green/Krilosker Biss
Takingout worn out and Replacement of Fan Belt for dynamo of 320/400 KVA DG Set at Power House,33 KV MRS, I-Lab, RSAF Airmen billet, Base Ops and Visiting Sqn. Make: Kirloskar/Fenner/Dunlop/Kirloskar green or eqv
As per item no 7 here-in-before but for 250 KVA DG set at WSA, complete all as directed by Engr-in-charge.Make : Kirloskar Bliss/Greaves
As per item no 7 here-in-before but for 200 KVA DG set at MAFI PS-II, complete all as directed by Engr-in-charge.Make : Greaves.
As per item no 7 here-in-before but for 160 KVA DG set at ATC and Base Ops, complete all as directed by Engr-in-charge.Make : Kirloskar Green
As per item no 7 here-in-before but for 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House, complete all as directed by Engr-in-charge.Make : Kirloskar Bliss/Kirloskar Green.
As per item no 7 here-in-before but for 100 KVA DG set at WSA(PH-12) complete all as directed by Engr-in-charge.Make : Kirloskar.
As per item no 7 here-in-before but for 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger complete all as directed by Engr-in-charge.Make : Kirloskar Green
As per item no 7 here-in-before but for 63 KVA DG set at BSO Yard complete all as directed by Engr-in-charge.Make : Ashok Leyland
As per item no 7 here-in-before but for 50 KVA DG set at Transmitter Bldg complete all as directed by Engr-in-charge.Make : Leyland/Cummins
As per item no 7 here-in-before but for 40 KVA DG Set at P.H. No-12(CWE Office), DDK Range of Make: Kirloskar.
As per item no 7 here-in-before but for 30 KVA DG Set at CADF of Make: Kirloskar Green
As per item no 7 here-in-before but for 20 KVA DG Set at 17 End arrester barrier,DDK Range and ATC of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Taking out and replacement of Radiator Fan Belt of 400 KVA DG set at Visiting Sqn of Make : Kirloskar Green
As per item no 8 here-in-before but for 125 KVA DG set at GCA power House of Make : Kirloskar Green
As per item no 8 here-in-before but for 160 KVA DG set at Base Ops of Make;Kirloskar Green
As per item no 8 here-in-before but for 250 KVA DG Set at WSA of Make: Kirloskar Green/Greaves
As per item no 8 here-in-before but for 82.5 KVA DG Set at HQ signal Section of Make: Kirloskar Green
As per item no 8 here-in-before but for 40 KVA DG Set at DDK Range and CWE Office.
As per item no 8 here-in-before but for 20 KVA DG Set at 17 End arrester barrier, DDK Range of Make : Kriloskar/Kirloskar Biss/Kirloskar Green
As per item no 8 here-in-before but for 50 KVA DG Set at Transmitter of Make: Kirloskar Green
Takingout and repair to of Water Pump Including replacement of complete assembly as Gasket, Bearing, rubber seal of 400 KVA DG Set of Make:Greaves.
As per item no 9 here-in-before but for 250 KVA DG set of Make : Kirloskar Bliss.
As per item no 9 here-in-before but for 200 KVA DG MAFI PS-II of Make : Greaves.
As per item no 9 here-in-before but for 160 KVA DG set of Make : Kirloskar Green
As per item no 9 here-in-before but for 100 KVA DG of Make : Kirloskar.
As per item no 9 here-in-before but for 82.5 KVA DG Set Make: Kirloskar Green
As per item no 9 here-in-before but for 63 KVA DG set of Make : Ashok Leyland.
As per item no 9 here-in-before but for 50 KVA DG Set of Make:Leyland/Cummins
As per item no 9 here-in-before but for 40 KVA DG Set of Make: Kirloskar.
As per item no 9 here-in-before but for 30 KVA DG Set of Make: Kirloskar Green
Taking out and replacement of shut down valve for the DG set of capacity 50 KVA Make of DG Set : Leyland/Cummins
Taking out and replacement of shut down valve for the DG set of capacity 400 KVA Make of DG Set :Greaves
Taking out and replacement of shut down valve of make for the DG set of capacity 200/250 KVA Make of DG Set :Greaves
M&L for Takingout and repalcement of oil presure meter for 63 KVA DG set Make: kirloskar/Ashok Leyland
M&L for Takingout and repalcement of oil presure meter for 125 KVA DG set Make: kirloskar/Bosch
M&L for Takingout and repalcement of oil presure meter for 160 KVA DG set Make: kirloskar/Bosch
M&L for Takingout and repalcement of oil presure meter for 82.5 KVA DG set Make: kirloskar/Bosch
M&L for taking out and replacement of Water temperature meter for 40 KVA DG Set .Make: kirloskar/Bosch
M&L for taking out and replacement of Water temperature meter for 125 KVA DG Set .Make: kirloskar/Bosch
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 20 KVA
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 30 KVA
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 63/82.5 KVA
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 160 KVA
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 250 KVA
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of Solenoid Switch, Penion, Auxiliary coil, carbon brush for the DG set of capacity 400 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 400 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 250 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 160 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 125 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 82.5 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 20 KVA.
Takingout burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush for the DG set of capacity 50 KVA.
Takingout and replacement of complete self starter of Make AUTOLEK or Equivalen for the DG set of 63 KVA DG Set of Make: Ashok Leyland
All as per item No 32 here-in-before but for 400 KVA DG Set Make:ENG- Greaves
All as per item No 32 here-in-before but for 250 KVA DG Set Make: Greaves
All as per item No 32 here-in-before but for 160 KVA DG Set Make: Kriloskar
M&L for fixing of Door Hinges for the DG Set of various capacity Make: Kirloskar/Kirloskar Green/Greaves
M&L for fixing the asbestos rope on silencer of DG set of various capacity including cladding with asbestos powder over wire mesh.
M&L for cleaning of the fuel tank by vacating the tank, replacement of fuel level indicator and spray painting of tank by scraping the existing paint using enamel paint of two coat with matching the existing clour.
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 20-125 KVA
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 125-400KVA
M&L for Replacement of Voltage regulator Device(AVR) for the DG set of capacity 20 to 50 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
M&L for Replacement of Voltage regulator Device(AVR) for the DG set of capacity 63 to 100 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
M&L for Replacement of Voltage regulator Device(AVR) for the DG set of capacity 125 to 250 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
M&L for Replacement of Voltage regulator Device (AVR)for the DG set of capacity 400 KVA of Make- Kirloskar/Kirloskar Green or Equivalent
M&L for earthing with Copper plate electrode of size 600 X 600 X3.15 mm thick buried directly in ground with earth pit not less than 3 mtr deep below ground level with top edge of plate not less than 2.4 mtr below normal ground level connected to Cu earth strip of size 20X3 mm up to 7.5 mtr by means of Cu nuts, bolts, check nuts and washers. And strip should be protected by galvanized iron pipe 50 mm dia of 'light grade' incl. cement concrete (1:3:6) type C1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 X 10 cm thick reinforced with 8 mm dia TMT bars @ 15 cm c/c both ways with 10 mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 50 mm dia galvanized iron pipe 'light grade ' for watering, incl charcoal or coke and salt in alternate layers and filling earth pit with fresh vegetable soil below GI plate & above upto ground level as required and necessary earth work in soft/hard soil complete all as shown in electrical plate No 3 of SSR Part 1 incl. testing on completion all complete as specified and directed by engg-in-charge. Note : (i) Charges for earth resistivity test deemed to be included in the quoted rate. (ii) Earth resistance value shall be less than 1Ω.
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 82.5 KVA DG set by Taking shut down from Main Power House , including replacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
Supply only Digital Amp meter of range 0-500 Amp
Supply only Digital Voltmeter of range 0-5000 Volt
Supply only Digital frequency meter of range 48-52 HZ
Supply only Indicator lamp of R-Y-B Phase.
Supply only 160A HRC fuse Make : L&T/SIEMENS or Equivalent / as per sample
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 400 KVA DG set by Taking shut down from Main Power House , including replacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
Supply only Digital Amp meter of range 0-500 Amp
Supply only Digital Voltmeter of range 0-500 Volt
Supply only Digital frequency meter of range 48-52 HZ
Supply only Indicator lamp of R-Y-B Phase.
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 125/250 KVA DG set by Taking shut down from Main Power House , including replacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
Supply only Panel battery charger of rating: Input 220 V Ac 50 Hz,Output 24 /12V 10 A Dc of Make: NHP or Equivalent
Supply only 3- phase, 415 V, 45-65 Hz Multi function Meter of Make -L&T or Equivalent
Takingout/servicing and refixing of power contactor 4 pole 250 to 325 Amps
Supply Only Digital Voltmeter of range 0-500 Volt
Supply Only AMF Controller Make: Kirloskar/Procom or Eqv.
Supply only 225A HRC fuse Make: L&T/SIEMENS or Equivalent /(AS per sample)
Supply only Start & Stop Relay 30Amps,24 Volt
Supply only digital Amps meter of range 0-500 Amps
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 63 KVA DG set by Taking shut down from Main Power House , including eplacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
Supply only 63 A 4-Pole Contactor OF MAKE. L&T,Model MCX 12 or Equivalent
Supply only 63 A HRC fuse Make: L&TSIEMENS or Equivalent
Supply only AMF Controller Make:Kirloskar/Procom or Eqv.
Supply only battery charger of rating 12/24 V 10 A Make-NHP or Equivalemt
Supply only Digital Amp Meter of range 0-500 Amps
Supply only Digital Volt meter rating 0-500 Volt
SSupply only Start & Stop Relay 30Amps, 12 Volty.
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 20 KVA DG set by Taking shut down from Main Power House , including eplacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
Supply only Digital Amp Meter of range 0-500 Amps
Supply only Air break power contactor, 240 volt, AC-I 40 amps, Make -L&T, Model No- MNX 40
Supply only Oil level indicator meter Make- Kirloskar or Equivalent
Supply only Push switch Make- L&T Or Equivalent
Supply only Battery charger of rating 12/24 Volt 10 A rating of Make NHP or Equivalent
Supply only R-Y-B phase indicator Make L&T or Equivalent
Supply only Start & Stop Relay 30Amps,24 Volty. Make: L&T or Equivalent
M&L For replacement of AMF controller unit for the DG Set of capacity 400 KVA of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 160 KVA of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 63/82.5 KVA of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 125 KVA of Make: Kirlosar/Procom/ or Eqv.
M&L for taking out and replacement and connection of Panel battery Charger of rating : Input 240V, 50 HZ and Output 12V, 5 A. Make- NHP or Equivalent
M&L for taking out and replacement and connection of Panel battery Charger of rating : Input 240V, 50 HZ and Output 12V, 5 A. Make- NHP or Equivalent
M&L for fixing of 180AH,12 Volt lead acid battery of Make: Exide New Express or equivelet.
M&L for taking down complete engine and overhauling fully DG set and remove spare parts i.e. exhaust manifold assembly, water pump assembly,Radiator assembly, hose pipe for radiator and water pump,fan belt, dynamo belt , electric connection ,drain out old engine oil and replacement of unserviceable piston head assembly (06 Nos),cylinder head repair, liner, ring,gasket alongwith all accessories of DG set of Capacity 100 KVA and refixing the all parts after repair testing for DG set and running condition. (Note : Supply only accessories will be measured and paid separately):--
Supply only Piston & Piston ring assembly (As per sample)
Supply only Cylinder liner (As per sample)
Supply only CR bearing with cover (As per sample)
Supply only Connecting Rod (As per sample
Supply only Oil Cooler cartridge 10 plates along with gasket (As per sample)
Supply only Engine Head Gasket (As per sample)
Supply only Head servicing and testing valve and steel polishing
M&L for taking down complete engine and overhauling fully DG set and remove spare parts i.e. exhaust manifold assembly, water pump assembly,Radiator assembly, hose pipe for radiator and water pump,fan belt, dynamo belt , electric connection ,drain out old engine oil and replacement of unserviceable piston head assembly (06 Nos),cylinder head repair, liner, ring,gasket alongwith all accessories of DG set of Capacity 63 KVA and refixing the all parts after repair testing for DG set and running condition. (Note : Supply only accessories will be measured and paid separately):--
Supply only Piston & Piston ring assembly (As per sample)
Supply only Cylinder liner (AS per sample)
Supply only CR bearing with cover (As per sample)
Supply only Connecting Rod (As per sample
Supply only Engine Head Gasket (As per sample)
Supply only Head servicing and testing valve and steel polishing
Supply only Crank shaft ball bearing (As per sample)
Supply only fly wheel ring (AS per sample)
M&L for filling of Distilled Water for Batttery
Repair/Serviceing of External battery charger for DG set of 12/24 Volt 0 to 40 A capacity of any make.
SUMAN CONSTRUCTION
Ganguly Construction
M/S Jamuna Traders
Kalpana Traders
Neha Enterprise
M/s Santosh Industrial Corporation
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .