| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 CrAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹2.6 Cr Quoted ₹2.7 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹2.7 Cr+₹4.7 L (1.77%)Rejected-Finance | ₹2.7 Cr+₹4.7 L (1.77%) | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹2.7 Cr+₹6.5 L (2.45%)Rejected-Finance 20 1ST A CROSS SAI NAGAR AREHLLI UTTARHALLI BANGALORE 560 061 | BENGALURU URBAN | KARNATAKA | 560061 | ₹2.7 Cr+₹6.5 L (2.45%) | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 4 | L4₹2.7 Cr+₹6.9 L (2.58%)Rejected-Finance NO 49 MSN NILAYAM 3RD CROSS HILL VIEW GARDEN TUNAHALLI SUBRAMANYAPURA POST BANGALORE 560061 | BANGALORE | BANGALORE | KARNATAKA | 560061 | ₹2.7 Cr+₹6.9 L (2.58%) | L4 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 5 | L5₹2.8 Cr+₹9.1 L (3.41%)Rejected-Finance | ₹2.8 Cr+₹9.1 L (3.41%) | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹2.8 Cr
EMD Value
₹3.5 L
Closing Date
27 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER R N D SECUNDERABAD
CHIEF ENGINEER R N D PICKET SECUNDERABAD 500003
ADDITION/ ALTERATION TO RMED CIVIL INFRASTRUCTURE (BUILDING NO 10) AT LRDE, BENGALURU
2022_MES_532153_1
CERD/BAN/TOKEN/12 OF 2022-23
Open Tender
Civil Works
Item Rate
365 days
LRDE BENGALURU
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I R N D WEST BENAGALURU
₹3.5 L
Yes
28 Sept 2022
20 Jun 2022
3 Aug 2022
20 Jun 2022
27 Jul 2022
12 Jul 2022
Amount
Demolition of unreinforced Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and disposed outside MD land.
40 mm thick plain cement concrete type B-0, 1:2:4 (12.5mm graded aggregate) as in flooring and finishing the surfaces even and smooth using extra cement all as specified and as directed.
M&L Polished Granite (of any type) stone 22 to 25 mm thick machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixure of pigment to match the shade of granite stone including cutting & polishing over 15mm thick screed in CM(1:4) complete all as specified and as directed.
Providing and applying 3 mm thick self levelling epoxy flooring system which consists of surface preparation includes ensuring the concrete surface is sound, even, firm and 28 days cured with moisture content not exceeding 5% and preparing the surface mechanically by grinding / shot blasting to remove dust, laitance and other contaminants like oil / grease and second part consists of one coat of two component penetrative epoxy based primer @ 0.15 to 0.2 Kg per Sqm followed by 2mm thick three component self lvelling epoxy underlay screed floor coating @ 4 Kg per Sqm having shore D hardness of 55 as DIN 53505, Compressive strength of 50 N/Sqmmas per IS 9162-1979, flexural strength of 30 N/Sqmm as per IS 9162-1979m pull off bond strength of 2.5 N/Sqmm as per ISO 4624, and tensile strength of 10-15 N/Sqmm as per ASTM D 2370-1973 and top coated with 1 mm self levelling pigmented epoxy flooring @ 1.6 Kg per Sqm having shore-D hardness of 70 as per DIN 53505, Compressive strength of 50-65 N/Sqmm as per IS 9162-1979, flexural strength of 20-25 N/Sqmm as per IS 9162-1979, pull off bond strength of 1.8-2 N/sqmm as per ISO 4624, and tensile strength of 10-15 N/Sqmm as per ASTM D 2370-1973 all complete as per specification and direction of Engr-in-Charge of approved colour Material used: 1. Sealer: Pro epishield floor sealer - 0.04 mm thick 2. Screed: Pro epishield screed - 2.0 mm thick 3. Finish coat: Pro epishield SL - 1.0 mm thick
S & F high density reflective conspicuity tape / stickers of width n exc 5 cm of approved colour fixed on existing floor of any description complete all as specified and as directed.
Taking down door / window / ventilator chowkat or frames with shutters n. exc 1.50 sqm each fixed or open type and removing from site all as specified and as directed.
Taking down door / window / ventilator chowkat or frames with shutters exc 1.50 sqm and n.exc 4 sqm each fixed or open type and removing from site all as specified and as directed.
Taking down door / window / ventilator chowkat or frames with shutters exc 4.0 sqm and n.exc 35 sqm each fixed or open type and removing from site all as specified and as directed.
Steel windows with frame and side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and as directed.
Steel windows or ventilators with frame, fixed type, with glazing bars complete all as specified and as directed.
Repairs to steel windows / ventiltors shutters of any description, area not exceeding 0.6 sqm including replacement of steel hinges and peg stay matching to the existing ones to make the shutter in perfect working condition and making good the disturbed portion and finshing the surfaces to match with existing surfaces complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and as directed.
S & F 4 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 Sqm in each pane all as specified and as directed.
Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.05 W/m K as per ASTM 518:1991,in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x25x2 mm. Galvanized iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. Tile:12 mm thick Densified tegular edged light weight calcium silicate false ceiling tiles.
Roughening surface of old concrete floor by picking, sweeping clean and washing with water to remove dust etc complete all as specified and as directed.
S&F Dark shade / double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to matchand incl 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
S&F Dark shade / double charged Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match & including 10mm thick rendering in CM (1:3) complete all as specified and as directed.
S&F Framed work such as grills, gratings etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work confirming to Fe- 290 Grade E-165 complete all as specified and as directed. Note: Plates, bolts used for ladder shall be measured and paid separately.
S&F Mild steel screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 cm and n.exc 22.5 cm long and dia of neck is 16 to 20 mm complete all as specified and as directed.
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410 -W (Gde- E- 250) quality-A complete all as specified and as directed.
S&F coloured Non Skid ceramic tiles 7 to 8mm thick (squares/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in epoxy grout to match over & including 15mm thick screed bed in CM(1:4) complete all as specified and as directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Preparation of old painted steel surfaces of any description, over 10cm in width or girth,not otherwise described and applying a coat of synthetic enamel paint complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and as directed.
Rendering 10mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
Preparation of new or previously untreated wall surfaces and applying two coats of distemper oil emulsion over a coat of alkali reistant primer over 1mm thick wall care putty complete all as specified and as directed.
Complete removal of existing treatment on walls and applying two coats of distemper oil emulsion over a coat of alkali reistant primer over 1mm thick wall care putty complete all as specified and as directed.
Complete removal of existing treatment on ceilings and applying two coats of distemper oil emulsion over a coat of alkali reistant primer over 1mm thick wall care putty complete all as specified and as directed.
Rendering 15mm thick in two coats as 5mm thick in CM 1:4 including mixing of water proofing compound over 10 mm thick in CM 1:6 on fair faces of brick work or concrete surfaces and finished even and smooth (without using extra lime or cement) complete all as specified and as directed. Note: WPC shall be measured and paid seperately
Supply only integral water proofing compound
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces over and including 1 mm thick putty, complete all as specified and as directed.
Rendering 5mm thick in CM 1:3 for ceiling on fair faces of brick work or concrete surfaces and finished even and smooth (without using extra lime or cement) complete all as specified and as directed.
Applying two coats of distemper oil emulsion over a coat of alkali reistant primer over 1mm thick wall care putty on ceiling surfaces including preparation of the newly plastered surfaces complete all as specified and as directed.
Removal of entire water proofing treatment in any position including raflt, plaster and removing the debris outside MD land all as specified and directed.
M & L for 10 mm thick rendeing in CM 1:4 over concrete surface (roof) mixed with water proofing compound @ 3% by weight of cement complete all as specified and as directed.
M&L APP based polymeric membrane minimum weighing 3.5 kg / sqm and minimum 3 mm thick reinforced with polyster non woven fabric (weight not less than 160 gms / sqm) laid over primer surface including bituminous primer conforming to IS-3384 applied @ 0.3 litre / sqm by torched application complete all as specified and directed. The roof treatment consisting of as under: i) Applying one coat of bituminous primer conforming to IS-3384 @ 0.3 lit per sqm ii) Laying of APP based membrane as specified thickness and weight iii) Applying two coats of aluminium paint @ 100ml / sqm for each coat
Dismantling structural steel work including doors, gates, railings etc but excluding framed truss etc.
Taking down steel rolling shutters of any area and any description including one coat of Synthetic enamel paint, top cover with all parts such as shaft, spring, ball bearing, drum, CI pulley complete from brackets, channel etc greasing and replacing worn out parts as directed by Engineer-in-Charge and re-fixing the same after realigning the shaft/guide channel, welding drum cage, servicing the components for smooth functioning complete all as directed by the Engineer-In-Charge. Note: Parts replaced will be measured and paid seperately
Supply only Hood cover
Supply only safety lever locks mild steel with 4 leavers for rolling shutters
Supply only ball bearing
Supply only anchoring rod
Supply only channels / guide rails
Supply only 1.25mm thick laths
S&F steel rolling shutters, without ball bearing, as specified including top cover, anchoring rod, hasp & staple & one shop coat of primer; erected in position as indicated, complete; push pull or manual type Thickness of laths 1.25 mm complete all as specified and as directed.
S&F safety lever locks mild steel with 4 leavers for rolling shutters
S&F ball bearing for rolling shutters
M&L 150mm thick PCC type B-2, (1:2:4) using 40mm graded stone aggregate as in hard standing complete all as specified and as directed.
Sand filling under floors or in foundation including watering & consolidation
M & L for rubber moulded Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 - 2006 of 60 mm thickness, M - 35 Grade with grey cement and no pigment complete all as specified and as directed.
M&L providing cement concrete of type C1, 1:3:6 using 20mm graded aggregate in kerbs including form work and weathering, slightly rounded or chamfered angles and throating all as specified and as directed.
Demolition of brick work or stone/ boulder masonry, PCC block masonry built in cement mortar including all quoins, pillars etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for, separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100 M and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge.
M&L Precast cement concrete 1:3:6 type C1 (Using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in CM (1:6) complete all as specified and as directed.
M&L Plain Cement Concrete Type B0 1:2:4 (using 12.5 mm graded stone aggregate) copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and as directed.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) and finishing the surface even and smooth complete all as specified and as directed.
M&L Applying two coat of synthetic enamel paint over a coat of primer on brick, stone, concrete, asbestos cement or plaster surface of any description over 10cm girth or width, not otherwise described including preparation of new surface complete all as specified and as directed.
M&L Precast cement concrete 1:2:4, type B1 (Using 20 mm graded stone aggregate) in landings, cover slabs (for manholes etc.) shelves and similar articles with plain faces and set in CM 1:6 complete all as specified and as directed.
M&L Mild steel TMT bars 10mm dia & over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips quality complete all as specified and as directed.
S & F 200 mm dia bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including taking down old pipes all as specified and as directed.
S & F PVC (SWR) bends any radius 200 mm dia of bore, all as specified and as directed.
Dismantling of aluminium partition / windows of any size and any description complete all as specified and as directed.
S&F powder coated aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S & F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.50 Sqm in each pane all as specified and as directed.
M & L 9 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber/ aluminium frame work in cup board shutters / aluminium partions etc..complete all as specified and as directed.
Taking down carefully existing copper/alluminium point wiring of light, fan, socket along with old lights of any type, laminated sheets, sunken boxes / boards concealed/surface type, including taking out concealed / surface conduit of any type and making good disturbed surface of walls and floors to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge.
Taking out old defective MCBs/isolators of any type and capacity complete from existing locations and making good disturbed surface of walls and floors to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge.
Taking out old unserviceable sub main wiring of any type and size including taking out concealed / surface conduit of any type and making good disturbed surface of walls and floors to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge etc .Note : The quoted rate is inclusive for taking down concealed conduit from the existing locations complete all as specified and directed by Engineer-in-charge
Taking out old DBs any type complete from existing locations and making good disturbed surface of walls and floors to match with the adjoining surfaces complete all as specified and directed by Engineer-in-charge.
Material and labour point wiring with 1.5 Sqmm ISI marked 1100 Volts grade (nominal cross sectional area ), single core, PVC insulated with multistranded PVC unsheathed FRLS copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked alongwith suitable conduit accessories including factory made modular GI metal flush box and modular white cover plate with frame including one continuity earth wire of PVC insulated, single core, multistranded,unsheathed 1.5 Sqmm (nominal cross sectional area ) FRLS copper conductor connected to all fittings, sunken boxes and common earth and connected to earth dolly complete all as specified and directed by Engineer-in-charge for the following::- Note : The quoted rate is inclusive for Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for laying of concealed conduit.
(a) One light / fan controlled by one, one way switch 5/6 Amps
(b) One 3 pin, 5/6 amps socket outlet point on independent board controlled by one, one way 5/6 amps switch
Material and labour Point wiring with 4 Sqmm (nominal cross sectional area ), single core, 1100 volts grade, ISI marked PVC insulated with multistranded PVC unsheathed FRLS copper conductor cable in and including rigid non- metallic PVC concealed conduit of suitable size medium grade ISI marked alongwith suitable conduit accessories including factory made modular GI metal flush box complete including modular metal flush box and modular white cover plate with frame as per requirement including one continuity earth wire of PVC insulated, single core, multistranded, unsheathed 4.0 Sqmm (nominal cross sectional area ) FRLS copper conductor connected to all fittings, sunken boxes and common earth and connected to earth dolly for one three pin 15/16 amps socket out-let point on an independent board complete complete all as specified and directed by Engineer-in-charge. Note : Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for concealed conduit shall be measure and paid separately under relevent item
S&F modular switch 1 way 6 Amps , 1 module complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Ceiling rose three terminals surface bakelite type, AC, 50 HZ, 230V complete all as specified and directed by Engineer-in-charge.
S/F modular socket 6 Amps 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S/F modular socket outlet 6/16 Amps combined 6 pin, 2 module and controlled by one switch complete all as specified and directed by Engineer-in-charge.
S&F modular switch 1 way 16 A , 1 module complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB DB, SPN, double door 12 ways, 240 volts flush in walls 200 Amps bus bar capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB DB, TPN, double door 8 ways, 415 volts flush in walls 200 Amps bus bar capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB DB, TPN, double door 4 ways, 415 volts flush in walls 200 Amps bus bar capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB DB, TPN, double door 12 ways, 415 volts flush in walls 200 Amps bus bar capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB SP 6 to 32 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB SPN 32 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge. .
Supply and Fix MCB TP 32 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge..
Supply and Fix MCB TP 63 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB TPN 63 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge.
Supply and Fix MCB TPN 100 Amps current rating 'C' series 10 KA breaking capacity complete all as specified and directed by Engineer-in-charge..
Material and labour Sub main wiring with 4 single core, 4 Sqmm, PVC insulated, PVC unsheathed, stranded copper conductor FRLS cable in and including PVC concealed/ surface conduit and earth wire with 2 x 4 Sqmm FRLS copper cable green colour fixed along with the sub main in PVC conduit and connecting to earth dolly complete all as specified and directed by Engineer-in-charge
Material and Labour Sub main wiring with 4 single core,6 Sqmm, PVC insulated PVC unsheathed FRLS stranded copper conductor cable in and including PVC concealed/ surface conduit, earth wire 2 x 6 Sq mm FRLS copper cable green colour connecting to earth dolly complete all as specified and directed by Engineer-in-charge
Material and Labour Sub main wiring with 4 single core 10 Sqmm, PVC insulated PVC unsheathed FRLS stranded copper conductor cable in and including PVC concealed/ surface conduit, earth wire 2 x 10 Sq mm FRLS copper cable green colour connecting to earth dolly complete all as specified and directed by Engineer-in-charge Note for Sl No. 89 to 91 : Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for concealed conduit shall be measure and paid separately under relevent item
Cutting channels, grooves or rebates n exc 15cm girth, and trimming surface with or without reinforcement for concealed conduit against for connected Schedule A items as per site requirements complete all as specified and directed by Engineer-in-charge.
Supply and fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps, 10kA, 'C' series, flush in walls including taking out old one complete all as specified and as directedby Engineer-in-charge
Supply and fix Triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Amps, 10kA, 'C' series, flush in walls including taking out old one complete all as specified and as directed by Engineer-in-charge
Taking down old conventional recessed ceiling fittings of any type / wattage from existing positions carefully making good distrubed surfaces to match with the adjoining surfaes including Supply and fixing LED ceiling mounted recessed full lit luminaire with glare free uniform illumination 34/36 W 2 ft x 2 ft (>100 Lumen/Watt) illumination suitable for ceiling, operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 80 and Driver Should be Constant Currnet LED Driver with 2.5 KV Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number, integral drivers, prewired and connecting with 3 Core 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge.MAKE:- Crompton Cat No.LCTLRNE-36-FO-CDL or techno equ in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Taking down old conventional tube light fittings of any type / wattage from existing positions carefully making good distrubed surfaces to match with the adjoining surfaces including supply and fixing wall mounted LED batten, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diiffuser should be High translucent serrated milky white , environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. MAKE:- Crompton cat No.CCS-103-20-65-SL-DP-NWH or techno equivalent in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply,Installation, Testing and Commissioning of 120W LED Highbay . Housing Made of Die-Cast Aluminium , Diffuser should be Clear Heat Resistant Toughned Glass IK07 with IP 66 Protection , System Efficacy should be >=110 Lm/W , System Having 10KV Surge apart driver surge, Fixture should be with safety chain for safety . Operating Voltage Range of 120V- 270V AC and Frequency 50HZ, Power Factor 0.95 ,THD<10%, Each LED with Individual lens and beam angle of 60 Deg, LED Life 50000 Burning Hours as per L70, CCT 5700K ANSI, CRI >70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R numberother safety test as per IS 15885 Part-2/Sec 13 . LEDs comply to the Photo biological safety standards as per IEC62471 and RoHS complete in all respects all a directed by Engineer-in-charge .Make Crompton Model No : LHB11-120-CDL/60-M or techno equivalent in philips/Havells/ Osram/ Wipro/Bajaj/GE as approved by GE.
Taking down existing exhuast fan of any type from existing locations carefully and making good all distrubed surfaces to match with the adjoining surfaces in and including Supply, fixing and testing exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers, making a hole on wall as per site conditions, duly marked location and MES No.complete all as specified and as directed by Engineer-in-charge.
Taking down existing ceiling fan of any type from existing locations carefully and making good all distrubed surfaces to match with the adjoining surfaces in and including Supply and fixing ceiling fans complete with blades, down rods, electronic dimmer 2 module step type and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed by Engineer-in-charge. Note for Sl No. 98 and 99 :- The quoted cost inclusive for handed over all old exhaust fans and ceiling fans to AGE E/M store yard complete all as directed by Engineer-in-charge.
Supply and fix in repairs wall mounted fan with 400mm sweep, 230 V, 50Hz fixed with anchor-fasterner nuts, etc. complete all as specified and as directed. Make : Havells Model : Platina with remote or techno commercially euipment model in Orient/ Bajaj/ Usha Note : Old removed wall fans to be deposited to MES.
Supply install testing and commissioning inverter type hi wall split unit indoor/outdoor of capacity 1.5 TR complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity complete all as specified and directed by Engineer-in-charge.
Supply fixing testing commissioning Voltage stabiliser cap 5 KVA 1 phase input variation 170 volt-250 volt, out put voltage stabilised at 230 volt complete all as directed by Engineer-in-charge.
Supply and fixing ODU Bracket factory made pwder coated suitable for 1.5Ton AC out door unit complete all as directed by Engineer-in-chaege.
Supply and fix sheet metal encl DP with a two pin and earth plug socket complete with one double pole MCB 20 Amps, 10kA, 'C' series complete all as specified and directed by Engineer-in-charge.
Material and labour sub main wiring 3 x 6 sqmm FRLS copper conductor cable, single core, PVC insulated, multistranded, unsheathed cable, 1100 volts grade drawn in the concealed PVC conduit of 25 mm complete all as specified and directed by Engineer-in-charge.
Supply install testing and commissioning of silent Diesel Engine driven generating set of cap 315 / 320 KVA 415 Volts, 3 phase 4 wire, engine and alternator all as per latest ISI standards and CPCB-II norms as amended upto date complete in and including Standard AMF panel as per manufactureres recommendations indoor type, electrinic governor control panel with necessary meters and sound proof canopy with PCC foundation as per manufactureres recommendations including 0.5 mtr all around the DG set and height of foundation minimum 0.5 mtr from GL complete all as directed by Engineer-in-charge. Note - (1) Supply of altrernator suitable for diesel engine all as per strictly engine manufactureres recommendations. warranty for the both is the responsibility of the quoted firm only. Engine - Kirloskar/Greaves cotton/ Ashok leyland. Alternator - Stampford/ kirloskar/Jyothi. (2) The quoted rate is deemed to be inclusive for the following :- (i) Factory testing of DG set with AMF panel as per manufacturer's procedures in the factory manufacturer premises before dispatch to site. (ii) Pre-commission test by the manufacturer engineer on the site after installation and also the presence of manufacturer's service engineer is mandatory during the 12 hours testing of DG set with AMF panel by the rep of Chief Engineer and the cost for the same in and including DHPP, load bank deemed to be included in the quoted rate. (iii) Two years maintenance, spares, etc. excluding lubricants and including tools as per manufacturer's recommendation to be submitted to Dept.
Material and Labour earthing complete with galvanised steel earth plate electrode 600 mm×600 mm.×6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not lessthan 1.5 metres below normal ground level, connected to galvanised earth lead wire 32 x 6 mm by means of bolts,nuts,check nuts and washers of galvanised iron or steel complete all as shown in electrical plate No. 3 connected to earthing test point and GI strip shall be drawn through GI pipe 40mm dia light grade upto 7.5 mtrs including watering arrangement with GI pipe 20mm dia medium grade with wire mesh funnel and PCC chamber, CI frame with cover and filling of charcoal and salt in layers including excavation and earthwork and including Testing on completion all as specified and directed by Engineer-in-charge.
Ashraya Nirman
K. VENKATESH NAIDU
PRAGATHI BUILDERS
M/S KVG CONSTRUCTIONS
Sai Ram Builders
M/S J J ENTERPRISES
D NAGI REDDY
meenakshi construction
M/s M Munivenkatappa and Company
ASSOCIATED ENGINEERS
Phoenix Infra
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .