Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69 LAccepted-AOC D NO 65 4 64 1A KOTHA NAKKAVANIPALEM MALKAPURAM POST VISAKHAPATNAM 530011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹70.0 L+₹99,000 (1.43%)Rejected-Finance 728 1 JOGIWARA VISHAVKARMA MANDIR ROAD AMBALA CITY | AMBALA CITY | AMBALA | HARYANA | 134003 | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹72.7 L+₹3.7 L (5.42%)Rejected-Finance 19 L LEHAL COLONY STATE COLLAGE ROAD PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹73.0 L+₹4.0 L (5.81%)Rejected-Finance PLOT NO 16 G BLOCK INDUSTRIAL PARK FAKIRTAKIA AUTO NAGER VISAKHAPATNAM 530046 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530046 | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 5 | L5₹77.3 L+₹8.3 L (12.0%)Rejected-Finance | L5 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹64 L
EMD Value
₹1.2 L
Closing Date
14 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
PROVISION OF OPs ROOM AT AIR FORCE STATION BEGUMPET UNDER GE AIR FORCE HAKIMPET
2023_MES_618708_2
84720/E8
Open Tender
Civil Works
Lump-sum
270 days
GE AF HAKIMPET
AS PER NIT
10 documents required · 10 mandatory
₹1,000
GE AF HAKIMPET
₹1.2 L
Yes
6 Jan 2024
15 Nov 2023
16 Dec 2023
15 Nov 2023
14 Dec 2023
30 Nov 2023
15 Nov 2023 - 24 Nov 2023
Amount
GENERAL SUMMARY NOTE: (i) Schedule ‘A’ Part I to X are prepriced by MES under Ser No. 1.10 to 10. Bidders shall insert their Lumpsum Amount in the Green coloured field under Col-6 only. (ii) Schedule 'A' Part -XI for which are to be quoted by Bidders.
Lumpsum price worked out by the contractor for “Building or Works” as listed in Schedule ‘A’ Part–I which are to be quoted by Bidders.
Lumpsum price worked out by the contractor for “Excavation and Earth Work for (For Schedule 'A' Part -II and Part -IV) as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–IV
Lumpsum price worked out by the contractor for “External Electrification ” as listed in Schedule ‘A’ Part – V.
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part– VI
Lumpsum price worked out by the contractor for “Air Conditioning” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “Fire Alarm System" as listed in Schedule ‘A’ Part VIII .
Lumpsum price worked out by the contractor for “DG Set" as listed in Schedule ‘A’ Part IX
Lumpsum price worked out by the contractor for “Misc E/M Items" as listed in Schedule ‘A’ Part X .
Schedule 'A' Part - XI : - Fittings, Fixtures & Misc items :- M&L for cutting road / PCC upto 150 mm thick for laying pipe for cable protection etc complete all as specified and as directed.
Supply and fixing surface mounted round LED luminaire 18 / 24 Watt 220 V AC pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete all as specified and as directed
Supply and fix Voltage stabilizer for automatic operation, single phase neutrally air cooled indoor type & design for input variation between 170 V to 250 V with output voltage stabilizer at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make : - V Guard / Vintech / Automatic Electrical / Brentted
M&L for configuring existing Fire Alarm Control Panel (Make-Ravel AVANI) and linking additional detectors, manual call points, Sounders etc complete all as specified and as directed.
Supply, laying, testing and commissioning of cabling for fire detection and alarm sysrem with 1.5 Sq.mm 2 core annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required. (Cost of MS conduit is deemed to be included in the quoted rate) ( Make :- Polycab / Havalls/ Finolex / RR kabel / KEI)
S&F telehpone socket RJ-45 & RJ-11(for Telephone / Data cable etc) complete all as specified and as directed.
Supply and installation, testing and commissioning of silent Diesel Engine driven generating set 415 volts, 3 phase 4 wire, engine as per IS:10001/ 10002 and Alternator as per IS: 13364 complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc. of Capacity 25 KVA complete all as specified and as directed for the following :-
(a) Diesel Engine The enginee shall be multi cylinder four stroke, 1500 RPM, Radiator water / coolant cooled, turbo charged complete with instrument panel, electronic governer, starting battery with lead, exhaust pipe and silencer pipe with suitable insulation by glass wool and aluminium cladding, safety devices and other standard fittings etc complete as per IS-10000 part-11 1980 and BHP suitable to the governer.
(b) Alternator The alternator should be designed for an output of 25 KVA continuous rating at 0.8 PF confirming to IS-4722 or BS-2613, RPM 1500 including self exciting and self regulating control panel with accessories, brushless design, electric supply teminal box with gland earth terminal etc complete all as specified.
(c) Fuel Tank The fuel tank shall be mild steel suitable to hold fuel for not less than 12 hours running capacity and shall be including fuel level indicator, fuel line from tank to the engine etc complete all as specified.
(d) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or as per standard practice of manufacture, ignition key switch, start/stop arrangement indication for engine parameters, hour run meter, RPM meter, engine oil pressure indication, water/coolant temparature indication, battery vilts display, annunciation with indication lamps for, low lube oil pressure, high water temperature, engine over speed, battery low voltage.
(i) AMF microprocessor operated control unit of suitable capacity for automatic operation of DG set & power contractors Make : Legrand, Havells or equivalant. This control unit can be installed floor/wall mounting, in generator minotoring panel or in AMF panel as per Manufacture recommendations
(ii) MCCB 415V. 3 phase 63A adjustable, 35 KA-02 (one for main supply & one for DG set supply) (III) Suitable Power contactor four pole - 02 Nos (one for main supply and one for DG set supply) (iv) Copper bus bar TPN 100 Amps - 01 set (v) Suitable battery charging unit -01 No (vi) DIgital multifunction meter for display of voltage, current, frequency, KVA, KW, KWH and PF. (vii) Electronic hooter (viii) Indication lamp for main ON, load mains, DG set ON, load on DG set, Battery DC supply ON. (ix) Voltmeter and ammeter for battery charging. (x) Suitable for MCBs for control circuit. (xi) Supply and lay control cable LT 1100 volts PVC insulted armoured heavy duty copper conductor of suitable size multicore (from DG set monitoring panel to AMF panel) (xii) Rubber matting of LV grand 19 mm thick of suitable size chequered.
(e) Battery :- Suitable Maintenance free battery with leads & terminals as per OEM recommendation (Make- Exide / Amron) .
(f) Civil Work : - All civil works including PCC platform and foundation suitable for installation of DG set alngwith anti vibration pad. The depth of foundation & PCC shall be as recommended by the manufactures. Rate quoted is deemed to be inclusive for this provision.
Notes :- (i) LT UG cable for connection between generator and AMF panel will be measured and paid separately. (ii) Diesel, grease, engine oil. etc required for commissoning and testing shall be deemed to include for the same. Testing shall be carried out as specified in particular specifications. (iii) DG set shall be provided with suitable size of acoustic enclosure provided with inside illumination with 1 No. 1 x 18 watt FTL fitting, the enclousre is duly epoxy coated and sound insulation to reduce noise level as per guide of Central Pollution Control Board or latest CPCB norms and OEM specifications and approved by Nodal agency , cost ot same is deemed to be included in the quoted rate.
Saiansh Associates
Vipin Kumar and Brother
BALAJI MATRIX HOLDINGS
CIVILEC ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .