Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹20,500
Closing Date
30 Jul 2022, 11:00 amClosed
Executive Engineer JSD PHE Mech Rural Division Sgr
Executive Engineer JSD PHE Mech Rural Division Sgr
Repairs/replacements and servicing of auxiliary power unit (40KVA DG Set) and other allied works on it at WSS Chattergam 2nd
2022_PHE_180408_1
PHE/MRD/TS/ 54 of 07/2022
Open Tender
Miscellaneous Works
Item Rate
5 days
Srinagar
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
Executive Engineer JSD PHE Mech Rural Division Sgr
2 Aug 2022
22 Jul 2022
30 Jul 2022
22 Jul 2022
30 Jul 2022
22 Jul 2022
Amount
Repairs/replacements and complete servicing of Auxiliary Power Units ( 40 kva D.G Set) at Water Supply Scheme Chattergam 2nd. The job shall be executed strictly as per the manufacturers guide lines and service manual and shall include replacement of serviceable items/stores and consumables like filters, hoses etc as required. The charges shall include items/ spare costs including carriage, stacking stores and incidentals if any at site. The charges shall not be limited to the items/spares shown here only and shall extend to items / stores also that are not specifically mentioned here but deemed necessary to be replaced. Technical specifications: • Type of power source = D.G Set • Capacity of D.G set = 40 KVA • Make of D.G. Set = Kirlosker • M oil filters = Complete Set • Fuel filters = Complete set • F/Bye Pass Filters = Complete Set • Air filters = Complete Set. • Anti vibration foundation • rubber pads = Complete Set. • Coolant = 10 ltrs
Complete checking and servicing of Alternator assy, which includes repairs to the Exciter coil of Alternator by dis-assembling the damaged exciter coil by technicians using tools/tackles/puller Cu-wire of required gauge and quality, refitting back the same on alternator. The job also includes P/F of AVR, Diode of 40 Amperes or equivalent after replacing damaged ones, worn out carbon brush rectifiers, bearings are to be replaced as per sample.
Testing of D.G. set on No-load for at least one Hour (for idling purpose) followed by testing on-full load at least for one complete shift.
M/S ASSOCIATE ENGINEERS
Friends Automobiles
M/S ASHRAF AUTO ELECTRIC WORKS
M/S BHAT ENTERPRISES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .