Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 LAccepted-Finance | L1 | Accepted-Finance Lowest | |
| 2 | L2₹13.2 L+₹41,135 (3.20%)Accepted-Finance HOUSE NO 3809 SAMRIDHI HOMES PEERMAUSHALA POST DHAKOLI MC ZIRAKPUR DISTT SAS NAGAR PIN 160104 | S A S NAGAR | PUNJAB | 160104 | L2 | Accepted-Finance Other than Lowest | |
| 3 | L3₹13.5 L+₹71,290 (5.55%)Accepted-Finance | L3 | Accepted-Finance Other than Lowest | |
| 4 | L4₹14.9 L+₹2.0 L (15.8%)Accepted-Finance | L4 | Accepted-Finance Other than Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Auronee Das GE (U) Chandimandir
GE (U) Chandimandir
GE(U)/CHM-34/2021-22 PROVN OF ROUTINE MAINTENANCE OF AIR TERMINAL NETWORK ,AVIATION LIGHTS OF VARIOUS OVERHEAD RESERVOIRS / TANKS AND REPAIRS / MAINTENANCE TO LIGHTS, EARTHINGS AND ATTENDING COMPLAINTS TO RECTIFY DEFECTS AT CHANDIMANDIR CANTT
2021_MES_485164_1
GE(U)/CHM-34/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (U) Chandimandir
As per tender Document
7 documents required · 7 mandatory
₹500
GE (U) Chandimandir
₹40,000
Yes
9 Dec 2021
30 Oct 2021
4 Dec 2021
30 Oct 2021
27 Nov 2021
13 Nov 2021
60 days
Amount
Excavating in trenches, for foundations, laying / taking out, pipes/cables in any type of soil, n. exc 1.50 m in depth and n. exc 1.50 m in width and getting out complete all as specified and as directed.
Returning, filling in soils including spreading, leveling, watering and well ramming in layer not exceeding 25 cm thick complete all as specified and as directed.
Removing excavated soils to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
Dry coarse sand, filled in trenches under and over underground cables, as cushioning to cable complete all as specified and as directed.
Supply and laying unreinforced precast concrete cable cover (ISI marked), class LV, type-2 flat size 300mm x180mm x 40mm, in trenches over sand as protection to cable complete all as specified and as directed.
Supply, laying, jointing, testing and commissioing XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor cable 1100 volts grade, 16 Sqmm 4.00 core, laid in trenches / sleeving through pipes or fixed on walls or laid under floors, in replacement (including taking up / down old unserviceable cable), complete all as specified and as directed. NOTE: Excavation and earth work shall be measured and paid for separately
40mm bore (internal dia) steel water tubing light grade, galvanised, with all fittings, laid in trenches or under floors for passing through cables, in replacement (including taking up/down old GI pipe), complete all as specified and as directed.
Air termination single pointed, copper rod, 12mm dia 300mm long with base plate / saddles fixed to any location / situation as directed with and including requisite fixing arrangement complete all as specified and as directed including dismantling / taking down existing rod and removing from site of work all as directed.
Test point terminal block made of gun metal or phosphorus bronze of size 75mm x 75mm x 25 mm drilled and screwed with and including requisite 03 no : 8mm dia 25 mm long hexagonal head screws fixed in any position and location complete all as specified and as directed including taking down old terminal block and removing from site of work, all as directed.
32mm x 6 mm galvanised iron / steel strip as earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or burried directly in ground or drawn in and including PVC conduit / pipe or any situation / location for loop earthing with and including arrangements for fixing to walls on battens or recess and including cutting chases as required and making good includuing excavation and earth work as required complete all as specified and as directed including taking up or down old strip all as directed.
25mm x 3.15mm thick aluminium strip with saddles and fixing screws and fixed to any location / situation as earth continuity / roof conductor / down conductor on overhead water storage tank / reserviours complete all as specified and as directed including dismantling / taking down existing strip and removing from site of work all as specified.
Taking down existing 32mm x 6mm galvanised iron / steel strip from any position / location and refixing the same with saddles and fixing screws for roof / down conductors on overhead reserviours / tanks, in proper position / alignement complete all as directed by Engr-in-Charge.
80 mm bore steel water tubing, galvanisewd, medium grade, with all fittings like base plate of mild steel of appropriate size and shape fixed as vertical post in ground, in cement concrete 1:2:4 type B-1 complete all as specified and as directed including taking down / up old steel tubing and depositing in store yard of AGE E/M-II all as directed. NOTE: Excavation and earth work shall be measured and paid for separetely.
DMC insulator of size SP-20 having approx size 50mm x 25mm x 25mm duly fixed on wall / roof / overhead tank / reservoir with two No steel screws and PVC rawl plugs grouted in wall / roof with drilling machine and 01 No strip holding GI bolt 6mm dia 25mm long with double nut and washers complete all as specified and as directed including taking down existing insulator and removing from site of work outside to MoD land.
All as per the description of serial item 14 here-in above but insulator of size SP-35 having approx size 90mmx40mmx35mm.
Earthing complete with galvanized steel plate electrode 600mm x 600mmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level), with top edge of the plate not less than 1.50m below ground level, connected with and including GI /Steel 32 mm x 6mm earth lead strip by means of bolts, nuts, check nuts & washers of galvanized iron / steel complete all as shown in electrical plate No 3 of MES Schedule Part-I and connected to earthing test point all as specified or indicated and testing on completion as directed by Engineer-in-Charge including excavation and earth work in any type of soil, funnel, plain cement concrete (1 :3:6) type C-1 Chamber, precast reinforced cement concrete (1:2:4) type B-1 pit cover of appropriate size with and including steel reinforcement, of thickness 50mm, charcoal, common salt including protection of earthing strip by and including 40mm bore galvanized steel tubing, medium grade and 20mm bore galvanized steel tubing, medium grade pipe for watering complete all as specified as shown on drg /plates as indicated and as directed including dismantling existing earthing and removing demolished materials outside the MoD land as directed.
NOTES: (a) RCC pit cover shall be precast with cement concrete 1:2:4 type B1 reinforced with 8mm dia TMT steel bars @ 100mm c/c bothways. (b) Earth lead 32mm x 6m of galvanised iron / steel protected with 40mm bore GI pipe shall be provided upto a length of 7.50 metre.
All as per the description of serial item 16 here-in above but with 4.00 mm dia GI wire earth lead protected by 20 mm bore galvanised steel tubing medium grade. NOTES: (a) RCC pit cover shall be precast with cement concrete 1:2:4 type B1 reinforced with 8mm dia TMT steel bars @ 100mm c/c bothways. (b) Earth lead 32mm x 6m of galvanised iron / steel protected with 40mm bore GI pipe shall be provided upto a length of 7.50 metre.
Aviation light low intesity aviation obstruction lamp of LED 300 single , 230 volt , total power consumption 15W-230V, max forward current-150mA, viewing all direction, protection weather proof IP-65 as per 2147, fixed in repairs (taking down old light), complete all as specified and directed . Make - Delta
Supply and fix in repair (taking down old cable) two single core cable with copper condutors of size 2.5 sqmm and 1.5 sqmm for earthing drawing into PCV rigid non metallic PVC conduit ISI marked, medium grade of 25 mm external dia, fixed on OHT inclusive of all fitting accessories complete and making good disturbed surfaces in repairs all as directed.
Double door SPN DBs four way of powder coated DB's suitable for MCB's fitted with bus bar, Neutral link, Earth bar and Din ral, fixed in repairs (taking down old DB) complete all as specified and as directed.
MCB SPN 5 to 40 amps 10 KA , C-series including connection with suitable size aluminium / copper lugs, fixed in repairs (taking down old MCB), complete all as specified and directed by Engr-In-Charge.
MCB SP 240 volts 5 to 40 Amps, 10 KA breaking capacity, 'C' type including connection with suitable size aluminium / copper lugs, fixed in repairs (taking down old MCB), complete all as specified and as directed by Engr-In-Charge.
MCCB 4 pole with neutral link 160-200 Amps 25 KA, in repairs (taking down old MCCB) complete all as specified and as directed.
All as per description of serial item No 23 herein above but 250-320 Amps 50 KA.
All as per description of serial item No 23 herein above but 125-160 Amps 36 KA.
22 watt surface and wall mounted LED batten fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate duffuser & integrated electronic driver with industrial grade heavy duty driver having THOL 10% complete with connecting suitable cable from ceiling rose to fitting all as directed by Engineer-in-Charge in repairs (taking down old LED fitting) complete all as specified and as directed.
Supply and fixing in repair (taking down) for energy saving and environment friendly LED Street lighting of 50 watt which uses 56 Nos high power LED as light source and IP 65 protection and luminaire housing is of pressure die-cast alluminium alloy 6063 Extrusion for heat sink for better heat transmission and connection with bracket of suitable and electrically, complete all as specified and directed by Engr-in-Charge IC.
LT feeder pillar box, in replacement, with 3.15 mm thick 75x60x25cm with GI Nut bolt for connecting earth conductor Weather Proof MS Sheet with Bus bar arrangement mounted on acrylic supprts with din rails and Slanting top kiosk to avoid accumalation of water , vermin proof ,powder coated ,both side openable with separate cable alley mounted with following accessories complete.
INCOMING : MCB TPN 32 Amp 10 KA C- Series - 01 Nos. OUTGOING: (i) three phase 4 Pole Power Contactor 20 Amp rating 415 V - 01 No. (ii) Timer 24 Hour Analog Time Switch (SST* - 30 min) toothed type mounted on din rails make L&T/Indoasian/Havells - 01 Nos. (iii) MCB SP 10 Amp 10 KA 50 Hz, 230 Volt - 4 Nos
LT feeder pillar box, in replacement, with 3.15 mm thick 75x60x25cm with GI Nut bolt for connecting earth conductor Weather Proof MS Sheet with Bus bar arrangement mounted on acrylic supprts with din rails and Slanting top kiosk to avoid accumalation of water vermin proof ,powder coated ,both side openable with separate cable alley with following accessories complete.
INCOMING :MCCB TPN 100 Amp 25 KA - 01 Nos. OUTGOING: (i) DOL Starter for 2 to 5 HP Motor Make LT/Indoasian/C&S. (ii) Changeover front operated 63 Amp 50 Hz 415 V complete all as directed make L&T/Indoasian/C&S - 01 Nos.
LED Wall Bracket fittings/bulk head, in replacement, philips vista glow 10-12W walllamp natural white or equivalent in approved makes for 6.5 to 10 watt LED all as directed
Supply and fix LED flood light, in replacement, 150W 120 degree IP 66 sysmmetric distribution luminarie with die cast aluminium housing finished in bloak and hammered finish bright anodised reflector and tonghened heat resistant glass cover and making connections with 23/0.0076 twisted copper flexible wire complete.
Attending complaints and rectifying meagre faults like decarbonsing connections in the DBs, checking for disconnections, any burning due to over loading in DBs and restoring water supply and illumination in water supply installations, repairing fittings like gate lights, tube lights, post top lantern, garden light fountain light, switches, sockets, ceiling rose/ holder, pole box, power point, DBs, MCBs, service connection by dicarbonising neutrals, checking for any loose connections in the boards, fixing loose casing capping, conduits, clamping if required complete all as specified and as directed by Engr-in-Charge. NOTES:- (i) All T&P (screw driver, testing lamp, plier, etc) required including ladder of appropriate size shall be arranged by the contractor. (ii) Minor items like machine screws, plastic clamps, insulation tape, nails, flexible pipe, thimbles, bottle lugs for DB's etc are deemed to be included in unit rate. (iii) Each job as per unit of the item shall comprise of attending nd rectifying 03 (Three) camplaints.
M/s Bhagwati Enterprises
KIRTI ELECTRICALS
Vasudeva Trading Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .