Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 01 BOKAKHAT UDAYNAGAR GOLAGHAT ASSAM 785612 | GOLAGHAT | ASSAM | 785612 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical BISHNUPUR MARANGI KANAIGHAT NH 39 VILLAGE TOWN KANAIGHAT CITY GOLAGHAT GOLAGHAT ASSAM 785699 INDIA | GOLAGHAT | ASSAM | 785699 | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹61,000
Closing Date
5 Nov 2026, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Nilakshi Thakur 9435599859
Numaligarh Refinery Limited
Miscellaneous Lighting Jobs for 3 Numbers of Blast-Proof Cabin at NRL
2026_NRL_931293_1
PUR1013427
Open Tender
Electrical Works
Works
365 days
Numaligarh Refinery Limited
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹61,000
Yes
6 Nov 2026
22 Oct 2026
6 Nov 2026
22 Oct 2026
5 Nov 2026
22 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 10 | Supply of LED Square 2x2 Downlighter complete with driver: * Mounting: Recess with provision for suspension,* Size: 595 × 595 sq. mm (approx), * Housing:CRCA housing with White Powder coated,* Optics: High quality polycarbonate diffuser,* Lumen output: ≥3600 Lumen at source,* Lumen per watt >= 85 L/W at 25°C* Colour Rendering Index: > 75,* Cromaticity range: As per ANSI Standard* Working life of LED: ≥ 50,000 hours @ L70,*System Watt: 34-36Watt ,* Nominal Voltage: 230V 50 Hz AC,* Operating voltage range = 170 V AC-270 V AC,* Driver: SMPS based constant current,* Total Harmonics Disturbance: < 20%,* Power Factor : ≥ 0.9, * Driver efficiency: ≥ 80 %* Minimum Burning life of Driver: ≥ 30,000 hours,*Corolated Colour Temperature: 6500 K(6530±510),* Efficacy : ≥ 55 lumen per watt* Junction Temperature:90°C @ 25° ambient temp.* Working Temperature Range: 0°C -45°C* Charge withstand Capacity: 2KV(IEC Std 61547),* Warranty period : 2 Years* Protection : IP20 or more,*Compliance : IS 10322 P-1 for safety.* Test Certficate LM 79 & LM 80 from NABL-accredieted laboratory needs enclosed,* Make:Havells/Philips /Bajaj/ CGL (Orion 36W). | 100 | NOS | - | - |
| 20 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting/2X2 Panel Light of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc.as required. | 100 | NOS | - | - |
| 30 | Supply of FLP Exhaust Fan:
FLP/Weather proof single phase Exhaustfan of the following specifications :
Rating: HP-0.33, 1 ph, 50Hz, 230Vac
RPM-1440;
Sweep-18"
Enclosure construction:Ex-d
Area Classification: DIV-1& 2, Gas-Gr. II A/B
Protection: IP-65
Temperature Class: T6
Peso Certificate Required : Yes
Motor having Copper Winding : Yes
Make: Sudhir/ Flexpro/ CEAG/Equivalent(To submit PESO Certificate) | 5 | NOS | - | - |
| 40 | Installation of FLP exhaust fan in the existing opening, including installation/fixing, making connection, testing, commissioning etc.as required.Upto 450 mm sweep as per direction of EIC. | 5 | NOS | - | - |
| 50 | Supplying and fixing following way, single pole and neutral,
sheet steel, MCB distribution board, 240 V, on surface/ recess,
complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including
earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door. | 5 | NOS | - | - |
| 60 | RCCB 4-Pole, 40A, 30mA having following specification:
# No of Poles:4
# Current Ratting:40A
# Operating Voltage:415V AC
# Sensitivity: 30mA
# Short Circuit Rating:10KA
# Ingress protection: IP20
# Tripping Characteristic: "C" Curve
# Test button for regular inspection
# Terminal: Cables upto 35sqmm cross sectional area
# Mounting: DIN rail
# Conforms to IS 12640-1:2000<(>&<)> IEC 61008-1 | 6 | NOS | - | - |
| 70 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing/new MCB DB complete with connections, testing and commissioning etc. as required 2P MCB. | 30 | NOS | - | - |
| 80 | Supplying and fixing following rating, four pole, 415 V, MCB in the existing/new MCB DB complete with connections, testing and commissioning etc. as required 4P MCB.Type-10 kA, "C" curve.Rating-63 Amps | 6 | NOS | - | - |
| 90 | Supply of ceiling fan Complete without Regulator, 1200mm sweep, double ball bearing, excellent & long lasting paint finish, Speed- 350RPM, Air delevery -230CMM. Make - ORIENT, BAJAJ OR HAVELLS, Colour - White ONLY which shall be equivalent to HAVELLS Velocity model as and when required as per the direction of E-I-C. | 20 | NOS | - | - |
| 100 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. | 20 | NOS | - | - |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.42 MB
BOQ_978636.xls
BOQ • 0.34 MB
Tender.pdf
Tender Documents • 1.52 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .