Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.2 L+₹1,764.50 (0.19%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹9.6 L+₹46,928.50 (5.14%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | UNIVERSAL INFRAPROJECT PVT LTD L1 | M/S ROHIT CONSTRUCTION L2 | S.R.Enterprises L3 |
|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed. | 12 | CUM | 250 ₹3,000 | 200 ₹2,400 | 90 ₹1,080 Lowest |
| 2.00 | Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed | 4.8 | CUM | 70 ₹336 | 100 ₹480 | 50 ₹240 Lowest |
| 3.00 | Excavation in soft / loose soil for post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. | 5 | EACH | 150 ₹750 | 200 ₹1,000 | 80 ₹400 Lowest |
| 4.00 | Surface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and directed | 50 | SQM | 25 ₹1,250 | 15 ₹750 Lowest | 25 ₹1,250 |
| 5.00 | Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed. | 7.2 | CUM | 70 ₹504 | 100 ₹720 | 50 ₹360 Lowest |
| 6.00 | M&L for hard core of broken stone / boulders, broken to gauge n.exc. 63mm complete all as specified and directed. | 7 | CUM | 800 ₹5,600 | 900 ₹6,300 | 450 ₹3,150 Lowest |
| 7.00 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. | 6 | CUM | 2,000 ₹12,000 Lowest | 2,800 ₹16,800 | 3,500 ₹21,000 |
| 8.00 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed. | 0.2 | CUM | 7,000 ₹1,400 | 3,200 ₹640 Lowest | 6,500 ₹1,300 |
| 9.00 | M&L for providing precast cement concrete louvres and jallies 25 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed. | 15 | SQM | 700 ₹10,500 | 600 ₹9,000 Lowest | 600 ₹9,000 Lowest |
| 10.00 | M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately. | 0.8 | CUM | 7,000 ₹5,600 | 4,500 ₹3,600 Lowest | 6,500 ₹5,200 |
Tender Value
₹9.6 L
EMD Value
₹19,200
Closing Date
1 Aug 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
ADDN / ALTERATION TO BUILDING NO. P-603 AT PRATAP ENCLAVE UNDER GE (S) JAIPUR AT JAIPUR MIL STN
2025_MES_718657_1
GE(S)/J-15P/2025-26 8995/E8
Open Tender
Civil Works
Item Rate
180 days
GE (S) Jaipur
Class E and category a(i)
8 documents required · 8 mandatory
₹500
GE(S) Jaipur
₹19,200
Yes
13 Sept 2025
4 Jul 2025
7 Aug 2025
4 Jul 2025
1 Aug 2025
18 Jul 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m depth for foundation etc or for shafts, wells cesspits manholes pier holes etc not exceeding 10 sqm on plan and in soft /loose soil etc complete all as specified and directed.
Returning, filing in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil etc complete all as specified and directed
Excavation in soft / loose soil for post holes (or similar holes) each not exceeding 0.50 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed.
Surface dressing not exceeding 15 cm deep in soft / loose soil complete all as specified and directed
Removal of excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed.
M&L for hard core of broken stone / boulders, broken to gauge n.exc. 63mm complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, cills, copings, bed plate, plinth courses, roof kerbs or mud stops rounded or chamfered on edges including necessary form work complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 25 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregate as in beam, cantilevers, bressummers, lintels over 1.5 m span and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
M&L for RCC (nominal mix) 1:2:4 type B1 using 20 mm graded stone aggregates as in columns, pillars, piers, posts and struts and similar work complete all as specified and directed. Note - Reinforcement and form work shall be measured and paid separately.
M&L brick work using old size sub class 'B' bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed
M&L for Form work to sides of pillars, posts, struts, piers, columns and stanchions for square, rectangular or polygonal rough finished concrete surface complete all as specified and directed
S&F Second class hard wood 35 mm thick glazed and skeleton shutters, open rebated and prepared to receive glass , gauze etc, divided into square,with plain, chamfered or rounded,mitered and rebated sash bars,any number, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR part I section 8 clause 8.24 (a) complete all as specified and directed.
S&F 40 mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, with both face are covered with decorative face veneer with lipping / frame to match complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sqm but n.exc 4.0 Sqm each with shutters (without taking off shutters from the frames) including making good of disturbed portion except space for holdfast complete all as specified and directed.
S&F mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate of 300 mm length of bolt complete all as specified and directed.
S&F door closer hydraulically regulated designation No 3, universal type, suitable for door shutter of weight between 61 to 80 Kg of aluminium (die cast) body complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 100 mm long stainless steel butt hinges fixed with CP finish steel screws as in PVC door complete all as specified and directed.
S&F stainless steel handles, fancy type, of 200 mm size complete all as specified and directed.
S&F stainless steel barrel tower bolts stove enamelled black with bright bolt 200 mm long complete all as specified and directed.
S&F mild steel framed work such as grills, gratings etc with ends of bars shouldered and / or riveted or forged into spikes, framed guard bars, barred iron doors and similar work conforming to Fe -290 Gde E-165 complete all as specified and directed.
M&L for mild Steel TMT bar 10 mm dia and over cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild Steel TMT bar 6 to 8 mm dia cut to length bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S&F rolled mild steel section as in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of grade Fe 410-W (Gde E-250) quality A complete all as specified and directed
S&F rolled mild steel section in roof trusses (framed), trussed, purlins, crane gantries,rail and fastenings and heavy bracket framing (beam, tee, angle,channel or flat sections) including distance pieces, cleat etc of grade Fe 410-W (Gde E-250) quality B complete all as specified and directed.
M&L for powder Coated (minimum thickness of powder coating 50 micron) anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed.
S&F powder coated (thickness of powder coating not less than 50 micron) anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1 No), hinges type B-21, 100 mm long (2 No) , suitable handle (1 No) complete all as specified and directed. Note-Glass and other filling material in panels shall be measured and paid seperately
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading, screws etc. complete all as specified and directed. Note:- The cost of 4.8mm thick glass and other filling material in panels shall deemed to be included in quoted rate.
S&F aluminium expanded metal for securing wiremesh over gauzed shutter complete all as specified and directed.
Taking down mild steel gate exc. 1.5 sqm but n.exc. 4 sqm for refixed in other opening after necessary minor repair including oiling / greesing etc. complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for suspended false ceiling (Make - Armstong ANF AH 95 or equivalent as approved by GE) extra micro-perforation size of 600 x 600 x 15 mm ceiling tiles over suspension metal system (MICRO LOOK) designer grid (15 mm grid 8mm return) SILHOUETTE X L 15 MM (NOMINAL) of Make Armstorng or equivalent make including necessary hanging system arrangement which is required to be made from existing RCC roof /stone /slab /AC sheet of existing ceiling complete all as specified and directed.
M&L for machine cut kota stone slab flooring mirror finished 20-25 mm thick (each slab not less than 0.25 sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing on treads of step and landing of stair including screed bed 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for 75 mm thick Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. and including brushing neat cement slurry with 3.0kg of cement per sqm complete all as specified and directed.
M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in vertical surface such as dado / skirting / risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including screed bed or bedding layer 15 mm thick in CM 1:6 complete all as specified and directed.
M&L for 08mm to 12mm thick coloured outdoor tiles exc. 0.09 sqm but n.exc 0.16 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including screed bed 20mm thick in CM 1:4 complete all as specified and directed. Make : Johnson Endura / Kajaria / Orient or equivalent as approved by GE.
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering on fair faces of brick work or concrete surface of wall 15 mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for complete removal of existing treatment and preparation of old surface of wall of any description and applying two coats of oil bound distemper over and including 1 mm thick wall putty complete all as specified and directed.
M&L for preparation of new surface of wall of any description and applying two coats of oil bound distemper (OBD) over and including 2mm thick wall putty all as specified and directed.
M&L for preparation of new surface of walls of any description with a coat of wall putty and applying two coats of acrylic emulsion exterior grade weather proof paint over a coat of primer complete all as specified and directed.
S&F 12 mm thick toughened glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed.
M&L for point wiring complete with 1.5 Sqmm single core (Phase - Red, Neutral - Black) PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade PVC insulated and unsheathed cable inclosed in and including concealed PVC conduit 20 mm dia medium grade with all accessories ISI marked, including MS sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting fitting like switches, sockets fan regulators etc. including 1.5 Sqmm single core (Green colour) PVC insulated unsheathed copper earth continuity conductor FRLS cable 1100 V grade as continuous earth wire for one light / fan / bell point controlled by one, one way switch. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonry and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for one 3 pin socket outlet 5 Amps on the same board with other switches, complete all as specified and as directed.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 1.5 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 1.5 Sqmm (Green), concealed in wall and drawn into and including rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 pin 5 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
M&L for point wiring with 1100 volts grade PVC insulated FRLS multistranded copper conductor cable 4.0 Sqmm (Phase - Red, Neutral - Black) and earth continuity conductor 4.0 Sqmm (Green), concealed in wall, drawn into and including rigid non metallic PVC conduit medium grade not less than 25 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and terminated in MS Sunken box of thickness not less than 1.2 mm, cover with 3 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulator as required for 3 Pin 15 Amps socket outlet on independent board, complete all as specified and directed. Note :- (i) The Switch / Socket accessories shall be measure and paid separately. (ii) The cost of MS sunken box & cover plate of size as required at site and cutting chases in stone / brick masonary and making good disturbed surfaces using CM 1:3 shall deemed to be included in quoted rate.
S&F in repair LED lights fitting 1x20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Modular Switch one way 6 A, 1 module complete all as specified and directed.
S&F modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F modular bell push 6A, 1 module complete all as specified and directed.
S & F Bell Ding Dong AC 230 volts, single pole complete all as specified and directed.
S & F Modular Socket, 6A - 2/3 pin combined, 2 module complete all as specified and directed.
S&F modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module complete all as specified and directed.
S&F sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB of capacity 20 Amps complete all as directed.
S&F sheet metal enclosure factory fabricated for MCB distribution board SPN double door type concealed in wall 240 Volt 8 way IP-42 protection with 200 amp rated bus bar complete all as specified and directed.
S&F ceiling rose 3 phase, PVC / polycarbonate, isolated body complete all as specified and directed.
M&L in repair for sub main wiring complete with 2 runs of 6 Sqmm single core PVC insulated unsheathed FRLS copper cable 1100 V grade with multistranded copper conductor ISI marked drawn through and including PVC rigid conduit / casing capping not less than 20mm and conduit accessories fixed on surface of wall / celing etc including provision of 1 Run of 6 Sqmm PVC insulated unsheathed FRLS cable with multistranded copper conductor as earth continuity complete all as specified and directed. Note : 02 Run of 06 Sqmm copper wire and 01 Run of 06 Sqmm copper earth wire along with PVC conduct shall be measured as one unit.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of Single Pole and 06 to 32 Amp current carrying capacity complete with connection testing and commissioning all as specified and directed.
S&F amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of SPN and 32 Amp current carrying capacity in the MCB DB complete with connection testing and commissioning all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) and removal of rubbish from site complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of AC corrugated / semi corrugated or translucent sheet as in roof coverings complete all as specified and directed.
M/S ROHIT CONSTRUCTION (BID ID -3376847)
S.R.Enterprises (BID ID -3379623)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .