Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.1 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹45.0 L+₹14.1 L (45.7%)Rejected-Finance AT ROAD TINSUKIA HIJUGURI BASH BARI P O HIJUGURI DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹47.2 L+₹16.3 L (52.9%)Rejected-Finance 01 CHANGSARI KAMRUP ASSAM 781101 | KAMRUP | ASSAM | 781101 | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹48.2 L+₹17.4 L (56.3%)Rejected-Finance PO PS BANDERDEVA DIST PAPUM PARE ARUNACHAL PRADESH PIN 791123 | PAPUM PARE | ARUNACHAL PRADESH | 791123 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹49.1 L+₹18.2 L (59.0%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹46.9 L
EMD Value
₹93,800
Closing Date
11 Jun 2025, 6:00 pmClosed
GE 872 EWS
GE 872 EWS, C/O 99 APO
REPAIR AND MAINT OF SECURITY PERIMETER HIGH MAST LIGHTS SOLAR LIGHTS GARDEN LIGHTS AND CONNECTED ITEMS AT LIKABALI MIL STN UNDER GE 872 EWS
2025_MES_702332_2
8724/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
LIKABALI
All as per NIT and Tender documents
7 documents required · 7 mandatory
₹500
Yes
GE 872 EWS
₹93,800
Yes
5 Jul 2025
28 May 2025
13 Jun 2025
28 May 2025
11 Jun 2025
4 Jun 2025
Amount
M & L for taking down Street/ Perimeter light fittings of any descriptions from any height after disconnecting electric connections and opening cover and checking of light fittings for serviceability and repaired as required and re-fixing the light fittings in existing position after repair and providing connections including replacement of defective/ unserviceable spares/ parts etc as required to make the fittings in smooth serviceable condition and testing complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc shall deemed to be included in the unit quoted rate)
Supply only Driver (as approved) suitable for LED street/ security light fittings of 30/35 Watt complete all as specified and directed.
Supply only Driver (as approved) suitable for LED street/ security light fittings of 40/45 Watt complete all as specified and directed.
Supply only Driver (as approved) suitable for LED street/ security light fittings of 60 Watt complete all as specified and directed.
M & L for taking down High mast light fittings of any descriptions from any height after disconnecting electric connections and repair the same by applying greasing, oiling etc as required and re-hoisting light fittings after reqpair including replacement of defective/ unserviceable spares/ parts etc as required to make the fittings in smooth serviceable condition and testing complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts shall be measured and paid seperately as "supply only" (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc shall deemed to be included in the unit quoted rate)
Supply only Driver (as approved) suitable for LED Flood light fittings of 120 Watt complete all as specified and directed.
S & F in repair LED 70 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell's Cat No. JETAALBAFLOODLIGHT70W or equivelant of make as per list of manufacturer)
S & F in repair LED 100 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell's Cat No. JETAALBAFLOODLIGHT100W or equivelant of make as per list of manufacturer)
S & F in repair LED 120 Watt flood light luminaire, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium, IP66, suitable for highlighting architectural facade and general purpose lighting with lamp and all accessories including mounting clamps, bolts, nuts and washers and copper conductor cable of suitable size to fittings of suitable length fixed as in High mast light at any height complete all as specified and as directed. (Make: Havell's Cat No. JETAIRISFL120WLED757APWBLTG or equivelant of make as per list of manufacturer)
M & L for taking down Solar light fittings of any descriptions from any height after disconnecting electric connections and repair the same by replacing of defective/ unserviceable spares/ parts etc as required and applying Jelly to the battery terminals, tightening of all connections, cleaning of solar panel thoroughly, filling distilled water to solar light battery to make the fittings in smooth serviceable condition and re-fixing the solar light fittings in its original position and testing complete all as specified and as directed. (Note: (i) Replacement of unserviceable parts, distilled water etc shall be measured and paid seperately as "supply only" (ii) Replacement of minor spares/ parts such as nuts, bolts & washer, worn out cables as per existing size etc shall deemed to be included in the unit quoted rate)
Supply only Solar light Battery, 12 Volts, 75 AH, Dry Gel (as approved) suitable for 3 days backup capacity complete all as specified and directed.
Supply only Tinned copper battery terminal (as approved) complete all as specified and directed.
Supply only Distilled water suitable for Solar light batteries complete all as specified and directed.
S & F in repairs 35 Watt LED Street light fittings, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 including lamp and connections complete all as specified and as directed. (Make: Havell's Cat No. ENDURASUNDOWNSL35WLED765PASYBOPC or equivelant of make as per list of manufacturer)
S & F in repairs 45 Watt LED Street light fittings, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08 including lamp and connections complete all as specified and as directed. (Make: Havell's Cat No. ENDURASUNDOWNSL45WLED765PASYBOPC or equivelant of make as per list of manufacturer)
S & F in repairs 60 Watt LED Street light fittings, New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and Toughened glass having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK07 including lamp and connections complete all as specified and as directed. (Make: Havell's Cat No. ENDURASUNDOWNSL60WLED765PASYBOTG or equivelant of make as per list of manufacturer)
S & F in repair 25 Watt, 230 Volts AC Post Top Lantern, outdoor type New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. (Make: Havell's Cat No. RUBYPT25WLED830SSYMTOPC or equivelant of make as per list of manufacturer)
S & F in repair 40 Watt, 230 Volts AC Post Top Lantern, outdoor type New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications with driver and lamp, fixing accessories and connecting up with suitable copper conductor complete all as specified and directed. (Make: Havell's Cat No. RUBYPT40WLED757PSYMTOPC or equivelant of make as per list of manufacturer)
S & F in repairs 08 Watt, LED Bollard light fittings, New generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source. including lamp and making good disturbed surfaces complete all as specified and directed. (Make: Havell's Cat No. BAMBOOBL8WLED830SSYMTOPCM or equivelant of make as per list of manufacturer)
Dismantling of unserviceable broken LT steel pole/Strut any size including demolition of foundation as required and making good disturbed surface complete all as directed. (Note : Earth work wherever invloved shall be measured and paid separately)
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside serviceable materials for re-use with in 50m and removing unserviceable materials from site of work complete all as directed by the Engr-in-Charge
Dismantling LT Stay assembly, of any size and unserviceable materials removing from the Site(s), complete all as specified and directed. (Note: (a) Unserviceable Stay assembly shall be taken off/dismantled at Ground Level and making good disturbed ground surface. (b) Earthwork for demolition of cement concrete shall be measured and paid separately under relevant Items of this Schedule.)
Dismantling/taking down old aluminium steel reinforced (ACSR) conductor of any size from LT overhead line including all jumper etc and keeping serviceable materials in safe custody for reuse in the work complete all as specified and directed.
Dismantling existing unserviceable GI earth wire, cradles of any type from service feeder or distributor span complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, trenches for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sq m on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches not exc. 1.5 metre wide and exc. 1.5 metre & not exc. 3 metre depth (beyond the first 1.5 metre) for foundation of poles etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for boring of horizontally holes by manual method under road and dia of hole not exc 100mm without damaging the exsting road, getting out and disposal of excavated soil, etc to a distance not exc. 50 meter from the site of work complete all as directed by Engineer in charge.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Plain cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, including necessary formwork complete all as specified and as directed.
M & L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including one coat of aluminium paint over a coat of red oxide zinc chrome primer and providing 03 Nos band/strap with black/yellow colour paint 300mm apart from the plinth block, numbering of pole painting embedded portion of pole with one coat of black bitumenous paint complete all as specified and directed. (Note : Excavation and Earth work shall be measured and paid separately)
M & L for Cross arms bracing supports clamps and back plates fabricated from structural steel sections including nut bolt washers welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide zinc chrome primer, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Dismantling of insulators of any type from LT poles of any size and type and setting aside complete all as specified and directed.
M & L for pin type porcelain vitreous white/brown insulator including one galvanised mild steel spindle two galvanised iron nut 100 mm height 65 mm dia suitable for 1100 volts grade complete all as specified and directed.
M & L for shackle type porcelain, insulator vitreous, white, brown or green, including galvanised mild steel, straps, washers, insulator bolts, washers and nuts, 100 mm height and 115 mm dia, size of strap 31 mm x 5 mm and dia of bolt 14 mm suitable for 1100 volts complete all as specified and directed.
M & L for loop type insulator, vitreous porcelain, white, brown or green of overall dimension 65 x 90 mm, clearance of hole 25.5 mm etc complete all as specified and directed.
S & F aluminium conductor steel reinforced (ACSR) conductor including binding, straining in LT over head line including all jumper connection and binding on insulator with new wire complete all as specified and directed.
Re-straining and tightening of existing serviceable ACSR conductor of any size without taking down including all arangement and including binding wire 2 mm dia and colour sleeve Jumpers complete all as specified and directed.
S & F in repair jumper made of ACRS conductor of suitable size and binding with and including aluminium binding wire properly on the existing LT OH line complete all as specified and as directed .
S & F PVC/fibre separator for LT over head line 1100 volts conductor 3/4 wire system for horizontal spacing of conductor complete with nuts and bolts minimum 2 Nos to prevent the line touching each other on heavy wind including taking down old separator complete all as specified and as directed .
M & L for galvanised steel continuous earth wire 3.15mm or 4 mm dia suitable for LT over head line complete all as specified and directed.
M & L for galvanised steel earth wire 4 mm dia (hexagonal/rectangular) used for craddle guarding suitable for LT/HT over head line complete all as specified and directed.
M & L for Stay assembly complete with all accessories as shown in electrical plate No 1 of MES Schedule Part I dia of stay rod 20mm with and including 7 / 3.15 mm galvanised stay strand complete all as specified and directed. (Note : Loop insulator, excavation & earthwork and cement concrete measured and paid separately under relevant items of this Schedule.)
Trimming of tree branches around the overhead conductor, poles & stays (not less than 3 metre) to clear the approach of overhead lines including removing of nest, wild grass creepers, unwanted vegetation, etc from pole/stay including cleaning of creepers climbed on poles and angles, channels and disposed off from site beyond 50m and upto a total distance of 250m complete all as specified and directed by the Engr-in-Charge.
M & L for Preparation of old painted surface above the planting depth/PCC coping of steel tubular LT pole upto 11.00 metre long including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to external surface of poles, MS cross arms, MS clamp, cable protection pipe etc to give even shade including 5 Nos strips painting of 300mm high each around the pole with two different colour (black/yellow) of synthetic enamel paint and numbering of poles complete all as specified and as directed by the Engr-in-Charge.
M & L for Preparation of old painted surface above the planting depth/PCC coping of Pre-stressed LT concrete pole upto 11.00 metre long by two coats of cement base paint including MS clamps, cable protection pipe, bracket fitted with steet light fittings etc by scraping with steel wire brush and applying one coat of aluminium paint to MS cross arms, MS clamp, cable protection pipe etc to give even shade and numbering of poles complete all as specified and as directed by the Engr-in-Charge.
S & F in repair PVC insulated and FRLS PVC Round Sheathed, multi-stranded Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 of size 1.5 Sqmm 3 core nominal cross sectional areacomplete all as specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, LT electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor conforming to IS-7098 (Part-I) 1988 of size 16 Sqmm 2 core including connection by using suitable size of aluminium thimbles, connectors, cable glands, bolts, nuts etc including taking up/down existing unserviceable cable complete all as specified and directed. (Note: Excavation and earth work will be measured and paid seperately)
All as per Serial item No. 50 above but 25 Sqmm 4 Core cable complete ditto
All as per Serial item No. 50 above but 35 Sqmm 3.5 Core cable complete ditto
M & L for Sand cushioning with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply and laying locally available best quality, well burnt sub class B bricks (old size), laid dry in trenches for protection of UG cables complete all as specified and directed.
S & F in repair for 40 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair for 50 mm bore, steel tubes, galvanised, light grade with all fittings, laid in floor/road crossing/drain etc as in cable protection complete to walls and ceilings or laid in floors complete all as specified and directed.
S & F in repair MCCB 415 Volt 16 KA, 4 Pole, 63 Amps Capacity complete all as specified and as directed . (Make: Havell's Cat Part No. IHLGNF0063 or equivelant of make as per List of Manufacturer's)
S & F in repair MCCB 415 Volt 16 KA, 4 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: Havell's Cat Part No. IHLGNF0100# or equivelant of make as per List of Manufacturer's)
S & F in repair MCCB 415 Volt, 36 KA, 4 Pole, 160 Amps Capacity complete all as specified and as directed. (Make: Havell's Cat Part No. IHA13EB40160 or equivelant of make as per List of Manufacturer's)
S & F in repair MCCB 415 Volt, 36 KA, 4 Pole, 200 Amps Capacity complete all as specified and as directed. (Make: Havell's Cat Part No. IHLLSEB40200 or equivelant of make as per List of Manufacturer's)
S & F in repair on load Change over switch, general purpose with side handle, current rating 100Amps, 4 pole, 415 V, 50 Hz complete all as specified and directed. (Make: L & T Cat No. CO11000OOOO or equivelant approved make as per list of manufacturer)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia TMT bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab of size 350x350x50mm (reinforced with 10 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion inclduing taking down old one complete all as specified and as directed by the Engineer-in-Charge.
M/S R D CONSTRUCTION (BID ID -3319793)
M/S A K ENTERPRISE (BID ID -3319691)
ABOTANI ENTERPRISE (BID ID -3319608)
Construction House (BID ID -3320041)
FREEZCON (BID ID -3319970)
MAA COMMUNICATION (BID ID -3319663)
M/S A K BROTHERS (BID ID -3319326)
M/s PRABIR ENTERPRISE (BID ID -3319096)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .