Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 CrAccepted-Finance BHUCHO | ₹10.3 Cr | L1 | Accepted-Finance Lowest amount bidder |
| 2 | L2₹10.3 CrRejected-Finance | ₹10.3 Cr | L2 | Rejected-Finance More than lowest amount bidder |
| 3 | L3₹11.1 CrRejected-Finance | ₹11.1 Cr | L3 | Rejected-Finance More than lowest amount bidder |
| 4 | Rejected-Technical HOSHIARPUR | HOSHIARPUR | HOSHIARPUR | PUNJAB | - | - | Rejected-Technical work Experince certificate not uoloaded as per required bid conditions |
| Sl No | Description | Qty | Unit | SURESH KUMAR CONTRACTOR L1 | M/S GARGA ASSOCIATES L2 | SHIV BHANDAR CONSTRUCTION CO. L3 |
|---|---|---|---|---|---|---|
| 1.00Providing of Asbestos Cement AC pressure pipe as per IS Code 1592 2003 by Mazza process PN 10 class 20 for water distribution system with all required accessories at site. | ||||||
| 1.01 | 4.65 km Long AC Pressure pipe 800 mm dia | 4,650 | MTR | 16,240 ₹7,55,16,000 Lowest | 16,279 ₹7,56,97,350 | 17,532 ₹8,15,23,800 |
| 1.02 | 1.10 km Long AC Pressure pipe 350 mm dia | 1,100 | MTR | 3,005 ₹33,05,500 Lowest | 3,037 ₹33,40,700 | 3,456 ₹38,01,600 |
| 2.00 | Earth Work in digging trenches as per IS Code 6530 1972 for laying AC Pressure pipe including labour material and TandP required for proper completion of work as per direction of Engineer in charge. | 17,073 | CUM | 112 ₹19,12,176 | 110 ₹18,78,030 Lowest | 121 ₹20,65,833 |
| 3.00 | Laying erection of 800 mm diameter Asbestos Cement AC Pressure pipe by Mazza process PN 10 class 20 for water distribution system with all required accessories and TandP to complete the work as per IS Code 6530 1972 | 4,650 | MTR | 3,940 ₹1,83,21,000 Lowest | 3,955 ₹1,83,90,750 | 4,255 ₹1,97,85,750 |
| 4.00 | Laying erection of 350 mm diameter Asbestos Cement AC Pressure pipe by Mazza process PN10 class 20 for water distribution system with all required accessories and TandP to complete the work as per IS Code 6530 1972 | 1,100 | MTR | 1,921 ₹21,13,100 Lowest | 1,955 ₹21,50,500 | 2,055 ₹22,60,500 |
| 5.00Providing erecting testing and commissioning of C.I plain end Bend with all required accessories and TandP to complete the work | ||||||
| 5.01 | size 800 mm x 22.5 degree | 2 | No | 1,20,000 ₹2,40,000 | 1,12,000 ₹2,24,000 Lowest | 1,36,000 ₹2,72,000 |
| 5.02 | size 350 mm x 22.5 degree | 1 | No | 9,400 ₹9,400 | 9,200 ₹9,200 Lowest | 10,800 ₹10,800 |
| 6.00Providing erecting testing and commissioning of C.I Double flange sluice valve as per IS 14846 PN 10 PD Type short body with both size tail pieces jointing material with all required accessories and TandP to complete the work. | ||||||
Tender Value
₹10.3 Cr
EMD Value
₹20.6 L
Closing Date
13 Jul 2026, 1:00 pmClosed
Superintending Engineer
Tubewell Circle banda
PROVIDING LAYING AND JOINTING OF AC PRESSURE PIPE BY MAZZA PROCESS OF 800 MM DIA 4.65 KM FOR MAIN CANAL 350 MM DIA 1.10 KM FOR TANGAMAU MINOR CLASS 20 AS PER IS CODE 1592 2003 AND IS CODE 6530 1972 WITH ALL FITTINGS AND OUTLETS AS PER DRAWIN
2026_UPIDM_1164683_1
01/SE/2026-27
Open Tender
Pipe Laying Works
Item Rate
90 days
Banda
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,354
₹20.6 L
24 Jul 2026
29 Jun 2026
14 Jul 2026
29 Jun 2026
13 Jul 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing of Asbestos Cement AC pressure pipe as per IS Code 1592 2003 by Mazza process PN 10 class 20 for water distribution system with all required accessories at site. | |||||
| 1.01 | 4.65 km Long AC Pressure pipe 800 mm dia | - | MTR | - | - |
| 1.02 | 1.10 km Long AC Pressure pipe 350 mm dia | - | MTR | - | - |
| 2Earth Work in digging trenches as per IS Code 6530 1972 for laying AC Pressure pipe including labour material and TandP required for proper completion of work as per direction of Engineer in charge. | |||||
| 3Laying erection of 800 mm diameter Asbestos Cement AC Pressure pipe by Mazza process PN 10 class 20 for water distribution system with all required accessories and TandP to complete the work as per IS Code 6530 1972 | |||||
| 4Laying erection of 350 mm diameter Asbestos Cement AC Pressure pipe by Mazza process PN10 class 20 for water distribution system with all required accessories and TandP to complete the work as per IS Code 6530 1972 | |||||
| 5Providing erecting testing and commissioning of C.I plain end Bend with all required accessories and TandP to complete the work | |||||
| 5.01 | size 800 mm x 22.5 degree | - | No | - | - |
| 5.02 | size 350 mm x 22.5 degree | - | No | - | - |
| 6Providing erecting testing and commissioning of C.I Double flange sluice valve as per IS 14846 PN 10 PD Type short body with both size tail pieces jointing material with all required accessories and TandP to complete the work. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.00 MB
Documents.pdf
Tender Documents • 5.66 MB
BOQ_2184037.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].