Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Not Admitted-Finance PROP NO A 80 FIRST FLOOR FLAT NO 3 CHATTAR PUR ENCLAVE PHASE 2 NEW DELHI SOUTH WEST DELHI DELHI 110074 | SOUTH DELHI | DELHI | 110074 | Not Admitted-Finance Others-FDR/EMD not submitted by the firm |
Tender Value
Refer Docs
EMD Value
₹14,100
Closing Date
3 Dec 2024, 11:15 amClosed
EE ENM M6
DELHI JAL BOARD MU BLOCK, PITAMPURA, DELHI-34
Replacement of motor control panel with all allied accessories at Sudarshan Park SPS in AC 25
2024_DJB_265188_15
NIT NO. 17(M-6)
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M 6
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No 50448339804
₹14,100
Yes
4 Mar 2025
23 Nov 2024
3 Dec 2024
23 Nov 2024
3 Dec 2024
23 Nov 2024
LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. Each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment's of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section, Each wire will be terminating with a ferule crimped to the wire, size 1200MM x1000x375mm. Having following components of approved make.
MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,400Amp with spreader & Handle Make L&T/Siemens/ DJB approved
MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz, 160Amp with spreader& Handle Make L&T/Siemens/ DJB approved
MCB Single pole 6Amp. Make L&T/Siemens / DJB approved
MCB Triple pole 63Amp. Make L&T/Siemens/ DJB approved
MCB Triple pole 32Amp. Make L&T/Siemens/ DJB approved
Over load relay 45-75ampMake. L&T/Siemens/ DJB approved
Over load relay 4.5-7.5 ampMake: L&T/Siemens/ DJB approved
Digital Amp. Meter Make AE/L&T/ DJB approved
Digital Volt Meter-Make AE/L&T/ DJB approved
Motor protection RelayM-10 Make: L&T/Siemens/Protech/ DJB approved
Power contactor 220V 3phase110Amp. Make L&T/Siemens/ DJB approved
Power contactor 220V 3phase95Amp. Make L&T/Siemens/ DJB approved
Power contactor 220V 3phase18Amp. Make L&T/Siemens/ DJB approved
Star delta timer on delay make: L&T/Siemens/ DJB approved
Indicating lights LED type RYB & On/OFF Make: L&T/Siemens/ DJB approved
Current Transformer 400/5& 200/5 & 30/5 Make AE/Advance/ DJB approved
On load change over switch 200Amp. Open execution type Make:L&T/HPL/ DJB approved
Supply of 25 sq mm Single core Copper Cable. Make Havells/Grandlay/gloster/ DJB approved
Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface.
Installation of the panel at site on base frame, laying of cable, termination of cable both incoming &out going side
Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow i) Continuity and earth testing ii) Meagering of all equipment's for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and bolts. iv) Alignments of doors etc. v Interlocking tests. All function tests
GOGIA BROTHERS (BID ID -1546767)
Premier Engineering Company (BID ID -1545521)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .