SITC of Cassette Air Conditioners in RBSC Chennai
2026_RBI_290312_1
1
Limited
Electrical Works
Works
Reserve Bank Staff College
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
RBSC Chennai
10 Sept 2026
10 Sept 2026
9 Oct 2026
10 Sept 2026
8 Oct 2026
18 Sept 2026
10 Sept 2026 - 17 Sept 2026
17 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0 | Laying and Jointing PVC Pipe. Heading | - | - | - | - |
| 1 | Supply of 02 TR capacity, minimum BEE 03-star rating, Inverter type Cassette AC unit with cordless remote, suitable plug top etc. as per the technical specifications given in the tender. (Cost should be based on free kit model such as copper pipes, wires included type AC unit, if OEM possess such free kit model available & also prevails in the market) | 3 | Nos | - | - |
| 2 | Supply of 03 TR capacity, minimum BEE 03-star rating, Inverter type Cassette AC unit with cordless remote, suitable plug top etc. as per the technical specifications given in the tender. (Cost should be based on free kit model such as copper pipes, wires included type AC unit, if OEM possess such free kit model available & also prevails in the market) | 1 | Nos | - | - |
| 3 | Installation, testing and commissioning (ITC) of above cassette air conditioner units (SN 01) with suitable supports, all labour charges, including gas top ups, pressure checks, providing wall opening, core cutting, finishing the surface used for taking copper pipe & drain pipes, pvc pipes end covered using white cement /suitable insulation material, handling, storage, transportation, loading, unloading etc. Rates shall also be inclusive dismantling of old existing split AC units (including pipes, wires etc at LAB-01 etc) and handover the same to the custody of Bank engineer. | 3 | Nos | - | - |
| 4 | Installation, testing and commissioning (ITC) of above cassette air conditioner units (SN 02) with suitable supports, all labour charges, providing wall opening, core cutting, finishing the surface used for taking copper pipe & drain pipes, pvc pipes using white cement /suitable insulation material, handling, storage, transportation, loading, unloading etc. | 1 | Nos. | - | - |
| 5 | Supply and erection of refrigerant copper pipes to integrate outdoor / indoor units of Cassette AC units at SN1 (both Gas and Liquid) as per manufacturer recommendations. The rate shall be inclusive of Nitrile insulation (tubular form). | 45 | Meters | - | - |
| 6 | Supply and erection of refrigerant copper pipes to integrate outdoor / indoor units of Cassette AC units at SN2 (both Gas and Liquid) as per manufacturer recommendations. The rate shall be inclusive of Nitrile insulation (tubular form). | 17 | Meters | - | - |
| 7 | SITC of suitable power / communication cable for the supplied AC mentioned in Sl.No.1 from outdoor unit to indoor unit without joints and as directed by the Bank Engineer. | 50 | Meters | - | - |
| 8 | SITC of suitable power / communication cable for the supplied AC mentioned in Sl.No.2 from outdoor unit to indoor unit without joints and as directed by the Bank Engineer. | 18 | Meters | - | - |
| 9 | SITC of Cotton Tape for covering copper piping for insulation as mentioned in Sl. No. 4 (a) & 4 (b). | 62 | Meters | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocument.pdf
Tender Documents • 0.63 MB
BOQ_338612.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .