Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance TP 117 2ND FLOOR MAURYA ENCLAVE PITAMPURA DELHI 110034 | DELHI | DELHI | DELHI | 110034 | Admitted-Finance |
| 2 | Admitted-Finance 194 IIND FLOOR POCKET 9 SECTOR 24 ROHINI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Finance |
| 3 | Admitted-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | Admitted-Finance |
| 4 | Admitted-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
30 Sept 2024, 6:00 pmClosed
GE (South West)
GE (South West) New Delhi-03
REPAIR/ REPLACEMENT OF INTERNAL FITTING AND FIXTURES OF DPL COMPLEX BLDG, MAYUR VIHAR, POCKET-1, REPAIR/ MAINT OF INTERNAL ELECTRIFICATION AND ALLIED WORKRS AT POCKET B AND D SECTOR-53, NOIDA, REPAIR/ MAINT OF INTERNAL AND EXTERNAL ELECTRIC SUPPLY,
2024_MES_666868_1
GE/SW-38/2024-25
Limited
Electrical and Maintenance Works
Item Rate
330 days
GE (South West) New Delhi
Class D Category b(i)
7 documents required · 7 mandatory
₹500
GE (South West) New Delhi
₹99,980
Yes
3 Oct 2024
2 Sept 2024
3 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
M&L for point wiring in replacement for modular switches with 1.5 Sqmm, PVC insulated, Copper conductor Cable, multistranded, FRLS, 1100 Volt grade, drawn through and including concealed, rigid non-metallic PVC Conduit with all fittings of minimum 20mm dia or as per site requirement including cadmium plated screws as per IS, including sunk type CI/steel terminal boxes concealed in any type of wall, including Modular cover plates/face plates etc and make good to the disturbed surfaces with existing one, including 1.5 Sqmm size, PVC insulated, Copper earth continuity conductor, connected to earth dolly, suitable for One light/ fan point controlled by one No 5 Amp, one way switch complete all as specified and as directed.
All as per item No. 1 here-in-before but point wiring suitable for one three pin, 5 Amps socket out let, on same board complete all as specified and as directed.
All as per item No. 1 here-in-before but point wiring suitable for one three pin, 5 Amps socket out let, on independent board complete all as specified and as directed.
All as per item No 1 here-in-before but point wiring with 2.5 Sqmm, single core, FRLS, copper conductor cables and 2.5 Sqmm, copper earth continuity conductor, suitable for one 3 pin 15 Amps socket out let point on independent board complete all as specified and as directed.
Supply only modular switch socket combination unit, 5 Amps, flush Type in existing modular Face plate/cover plates etc as per existing model and size complete all as specified and as directed.
Supply only switch socket combination unit,15 Amps, Modular Type in existing modular Face/cover plate etc as per existing model and size complete all as specified and as directed.
S & F in replacement modular Switch, one Module, 6 Amp complete all as specified and as directed.
Supply only Modular switch, one Module, 16 Amps complete all as specified and as directed.
Supply only modular Switch, one Module, 6 Amp, 2 Way complete all as specified and as directed.
Supply only modular socket outlet 3 pin, 2-in-1 combined, 6 Amp, 2 Modules complete all as specified and as directed.
Supply only modular socket outlet, 5 pin, 2-in-1 combined, 6 & 16 Amp, 2 Modules complete all as specified and as directed.
Supply only modular step type, fan regulator, 230V, single phase, 2 Module complete all as specified and as directed.
Supply only Bell Push switch, Modular type, single pole, 5 Amp complete all as specified and as directed.
Supply only PVC, Non metallic, Casing Capping with interlocking arrangement of 20 mm size, medium grade, including all fittings such as tees, bends, elbow, reducers, bell mouth tube end and fixing accessories such as coupler, lock nuts, saddles, pipe hooks etc but excluding junction boxes complete all as specified and as directed.
All as per ser item No. 15 here-in- before but 25 mm size complete all as specified and as directed.
All as per ser item No. 15 here-in- before but 32 mm size complete all as specified and as directed.
Supply only PVC Conduit of dia 20 mm including all accessories i.e Tees, Bends, Elbow, Reducers, Bell Mouth tubeend and all other standard fixing accessories such as coupler, lock, nuts, saddles, pipe hooks etc but excluding of junction boxes complete all as specified and directed at site.
All as per item srl No. 18 above but 25 mm dia.
All as per item srl No. 18 above but 32 mm dia.
S&F in replacement sub main wiring with 2 runs of 2.5 Sqmm, single core, PVC insulated FRLS Power Cable 1100 Volts grade with multi stranded, copper conductor, drawn through existing surface /recessed steel/PVC conduit or casing capaing and one run of 2.5 Sqmm size PVC insulated copper conductor cable as earth wire complete all as specified and as directed. Note:- Two run of cable along with one run of earth conductor shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 4 Sqmm, single core, PVC insulated FRLS Power Cable 1100 Volts grade with multi stranded, copper conductor, drawn through existing surface /recessed steel/PVC conduit or casing capaing and one run of 4 Sqmm size PVC insulated copper conductor cable as earth wire complete all as specified and as directed. Note:- Two run of cable along with one run of earth conductor shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated FRLS Power Cable 1100 Volts grade with multi stranded, copper conductor, drawn through existing surface /recessed steel/PVC conduit or casing capaing and one run of 6 Sqmm size PVC insulated copper conductor cable as earth wire complete all as specified and as directed. Note:- Two run of cable along with one run of earth conductor shall be measured as one RM length).
S&F in replacement sub main wiring with 2 runs of 10 Sqmm, single core, PVC insulated FRLS Power Cable 1100 Volts grade with multi stranded, copper conductor, drawn through existing surface /recessed steel/PVC conduit or casing capaing and one run of 10 Sqmm size PVC insulated copper conductor cable as earth wire complete all as specified and as directed. Note:- Two run of cable along with one run of earth conductor shall be measured as one RM length).
Supply only LED Recess Mounted Type, 2 x 2 feet Luminarie with high brightness fittings LED, 36 Watt, White/Worm White, cast Aluminium housing, toughened glass, Silicon gasket 6500K high power LED with lens for uniform distribution and suitable for armstrong/grid ceiling, pre-wired and electric connection with suitable size stranded copper flexible PVC insulated wire including clamps and nut & bolts for fixing complete all as specified and directed. Make : Havells Cat Part No. LHEBAEP7IW1W036 or its equivalent model mentioned in PS.
Supply only LED Surface Mounted Type, Full window opal diffuser, LED panel light fitting, 36 Watt, size 600 x 600 mm with CRCA powder coated white housing surge voltage protection minimum 3 KV, including connection copper flexible PVC insulated wire and all other standard fixing accessories complete all as specified and directed. Make : Havells Cat Part No. PLANOSUR2X2PLS36WLED857S0720 or its equivalent model mentioned in PS.
Supply only LED surface mounted batten for LED T-8 tube fitting 1X20 W 4 feet long of pre-wired and electric connections, decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient complete all as specified and directed. (Make- Havells Cat No:- LHEXAWP7IN1W020 or equivalent model of Make mentioned in PS.
Supply only 10W, 230 V, LED batten, 2 Feet long with Polycarbonate housing & integrated electronic driver suitable for surface and wall mounted complete all as specified and directed. (Make : Havells Cat No:- LHEXACP5IN1W010 or equivlent make in PS )
Supply only energy efficient LED downlighter fitting, Round shape, recess mounted type,18 W , 6000 K 230 Volt, Ultra bright compact in polycarbonate housing with high brightness LED chips, Ideally suited for low ceiling areas to give glare free light, complete all as specified and as directed. (Make : Havells Cat No LHEBFCP7IZ1W018 or equivalent Model of Make mentioned in PS)
Supply only energy efficient LED downlighter fitting, Round shape, recess mounted type, 20 Watt, 6500 K, 230 Volt, Ultra bright compact in polycarbonate housing with high brightness LED chips, Ideally suited for low ceiling areas to give glare free light, complete all as specified and as directed. (Make : Havells Cat No LHLDESAFRANE020 or equivalent Model of Make mentioned in PS)
Supply only energy efficient LED down light fitting, square shape, surface mounted type, 18 W LED 6500 K 230 Volt, decorative, ultra slim, linear LED lighting fixture, with optimised heat sink, environmental friendly, energy efficient, integrated electronic driver complete all as specified and as directed. (Make : Havells Cat NoLHEAABP7IN1W018 or equivalent Model of Make mentioned in PS)
Supply only energy efficient LED down light fitting, square shape, surface mounted type, 24 W LED 6500 K 230 Volt, decorative, ultra slim, linear LED lighting fixture, with optimised heat sink, environmental friendly, energy efficient, integrated electronic driver complete all as specified and as directed. (Make : Havells Cat No LHEAABP7IN1W024 or equivalent Model of Make mentioned in PS)
Supply only wall mounted fan, PVC Body complete with all standard accessories, 230 V, 400 mm sweep complete all as specified and directed.
Supply only Ceiling fan complete with blades, down rods and accessories, 230 V, 1200 mm sweep 5 star rating with brushless direct current motor complete all as directed.
Supply only Exhaust Fan of size 250 mm sweep, 230 Volts, AC, single phase, copper winding, made up of sturdy Engineering plastic complete with louvers /shutter including fixing arrangement at any type of window with the help of wooden ply etc complete all as directed.
Supply only Exhaust Fan of size 300 mm sweep, 230 Volts, AC, single phase, copper winding, made up of sturdy Engineering plastic complete with louvers /shutter including fixing arrangement at any type of window with the help of wooden ply etc complete all as directed.
Supply only Exhaust Fan of size 300 mm sweep, 230 Volts, AC, single phase, copper winding, made up of Steel Body complete with louvers /shutter including fixing arrangement at any type of window with the help of wooden ply etc complete all as directed.
Supply only Exhaust Fan of size 380 mm sweep, 230 Volts, AC, single phase, copper winding, made up of Steel Body complete with louvers /shutter including fixing arrangement at any type of window with the help of wooden ply etc complete all as directed.
Supply only Exhaust Fan of size 450 mm sweep, 230 Volts, AC, single phase, copper winding, made up of Steel Body complete with louvers /shutter including fixing arrangement at any type of window with the help of wooden ply etc complete all as directed.
Supply and fix in replacement electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate,NRV, connection piece all as specified and directed.
Supply only of MCB, SP, 6 to 32 Amps, 240 Volts, 10 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCB, SPN, 32 Amps, 240 Volts, 10 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCB, SPN, 40 Amps, 240 Volts, 10 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCB, SPN, 63 Amps, 240 Volts, 10 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCB, TP, 63 Amps, 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCCB, four pole 100 Amps, 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCCB, four pole 125 Amps, 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only MCCB, four pole 63 Amps, 415 Volts, 16 KA, 'C' Curve as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply only sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB, SP, 32 Amp capacity, 2P+E complete all as specified and as directed.
Supply only Tempra Pro Industrial type sheet metal enclosure with socket plug top, 3 Phase and neutral enclosure with three pin earth plug and socket complete with one MCB, TP, 63 Amp capacity, 3P+E complete all as specified and as directed.
Supply only single core, copper conductor cable, PVC insulated, FRLS, 1100 Volt grade, 1.0 Sqmm size, multistranded complete all as specified and as directed.
All as per ser item No. 50 here-in- before but 1.5 Sqmm complete all as specified and as directed.
All as per ser item No. 50 here-in-before but 2.5 Sqmm complete all as specified and as directed.
All as per ser item No. 50 here-in-before but 4.0 Sqmm complete all as specified and as directed.
All as per ser item No. 50 here-in-before but 6.0 Sqmm complete all as specified and as directed.
S & F in replacement MCB DB double door, SPN, 4 Way with 200 Amp Cu bus bar, suitable for Flush Mounting and Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
S & F in replacement MCB DB double door, SPN, 8 Way with 200 Amp Cu bus bar, suitable for Flush Mounting and Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
Supply and fixing in replacement of MCB distrubution board vertical type 250 Amps double door type steel sheet flush mounting type factory fabricated, powder coated, degree of protection IP-42 detachable gland plate neutral link, earth link with copper bus bar houseing with one incommer MCCB, four pole of rating 250 amp and 36 outgoing ways (without MCBs) complete all as specified and directed.
Supply and fixing in replacement of MCB distrubution board vertical type 125 Amps double door type steel sheet flush mounting type factory fabricated, powder coated , degree of protection IP-42 detachable gland plate neutral link, earth link with copper bus bar houseing with one incommer MCCB, four pole of rating 125 amp and 24 outgoing ways (without MCBs) complete all as specified and directed.
Supply only 3 Module, PVC box with modular face plate/cover plate etc suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply only 4 Module, PVC box with modular face plate/cover plate etc suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply only 6 Module, PVC box with modular face plate/cover plate etc suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply only 8 Module, PVC box with modular face plate/cover plate etc suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply only modular metal flush box, 2 Module, suitable for fixing of modular Switches/ sockets complete all as specified and as directed.
Supply only modular metal flush box, 3 Module, suitable for fixing of modular Switches/ sockets complete all as specified and as directed.
Supply only modular metal flush box, 4 Module, suitable for fixing of modular Switches/ sockets complete all as specified and as directed.
Supply only modular metal flush box, 6 Module, suitable for fixing of modular Switches/ sockets complete all as specified and as directed.
Supply only PVC Insulation tape/roll of 5 mtr length each of all four colours (R,Y,B & Black) for day to day use complete.
Supply only capacitor 1.5 mfd capacity, 230 Volts, AC supply, single phase, suitable for existing Ceiling fan complete all as specified and as directed.
M&L in replacement for LED Flood Light luminaire 100 Watt 230 Volt energy saving & enviornmental friendly, long life diecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed.
M&L in replacement for LED Flood Light luminaire 120 Watt 230 volt energy saving & enviornmental friendly, long life diecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed.
M&L in replacement for LED Flood Light luminaire 170 Watt 230 volt energy saving & enviornmental friendly, long life diecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed.
M&L in replacement for LED Flood Light luminaire 210 Watt 230 volt energy saving & enviornmental friendly, long life diecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed.
M&L in replacement for LED Flood Light luminaire 500 Watt 230 volt energy saving & enviornmental friendly, long life diecast aluminium, IP66, with high power LED as light source incl necessary fixing arrangement with clamps of suitable size and connection using 1.5 Sqmm PVC insulated copper cable complete all as directed.
Supply in replacement of LED surface mounted batten for LED T-8 tube fitting 4 ft, suitable for 1x18w pre-wired and electric connections, polycarbonate housing and integrated electronic driver complete all as specified and directed.
Supply in replacement of three core, copper conductor cable, 3x1.0 Sqmm size, multistranded, Flat/Round type, PVC insulated, FRLS, 1100 Volt grade complete all as specified and as directed.
Supply in replacement of three core, copper conductor cable, 3x1.5 Sqmm size, multistranded, Flat/Round type, PVC insulated, FRLS, 1100 Volt grade complete all as specified and as directed.
Supply in replacement sub main wiring with 4 runs of 10 Sqmm, single core, PVC insulated FRLS Power Cable 1100 Volts grade with multi stranded, copper conductor, drawn through and including 32 mm dia, concealed, PVC rigid, non metallic conduit, medium grade, as per IS and one run of 10 Sqmm size PVC insulated copper conductor cable as earth wire complete all as specified and as directed. Note:- Four runs of cable along with one run of earth conductor including PVC rigid conduit shall be measured as one RM length).
Supply in replacement of Switch Socket combination, 5 in 1, 5 &15 Amps, flush type, 2 fixing holes as per existing model and size complete all as specified and as directed.
Supply in replacement of Switch Socket combination, 2 in 1, 3 pin 5 Amps, flush type, as per existing model and size complete all as specified and as directed.
Supply in replacement of 16 Amp & 6 Amp, 2-in-1, 5 pin, combined unit box, modular type, with Switch Socket Combination, face plate/cover plate etc holes complete all as specified and as directed.
Supply in replacement 6 Amp, 2-in-1, 5 pin, combined unit box, modular type, with Switch Socket Combination, face plate/cover plate etc complete all as specified and directed.
Supply in replacement of Switch Piano flush type, single pole, one way, 5 Amp, 2 fixing holes complete all as specified and as directed.
Supply in replacement of Switch Piano, flush type, single pole, one way, 15 Amps, 2 fixing holes complete all as specified and as directed.
Supply in replacement of Switch Piano flush type, single pole, 2 Way, 5 Amp complete all as specified and as directed.
Supply in replacement of Bell Push Switch, flush type, single pole, 5 Amp complete all as specified and as directed.
Supply in replacement of Socket Outlet, 2-in-1, 3 pin, 6 Amps, flush type, with 2 fixing holes complete all as specified and as directed.
Supply in replacement of Socket Outlet 2-in-1, 5 pin, 6 and 16 Amps, flush type, with 2 fixing holes complete all as specified and as directed.
Supply in replecement of Modular step type, fan regulator, 1 Module, 4 step, complete all as specified and as directed.
Supply in replacement of 12 Module, PVC box suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 8 Module, GI Metal box suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 12 Module, GI Metal box suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 3 Module, Face Plate / Cover Plate Modular Type suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 6 Module, Face Plate / Cover Plate Modular Type suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 8 Module, Face Plate / Cover Plate Modular Type suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of 12 Module, Face Plate / Cover Plate Modular Type suitable for fixing of modular Switches/ sockets complete all as specified and directed.
Supply in replacement of Bell Buzzer 230 Volts, AC supply, single phase complete all as specified and as directed.
Supply in replacement of MCB, SP, 16 Amps, 240 Volts as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply in replacement of MCB, SP, 20 Amps, 240 Volts as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply in replacement of MCB, SP, 32 Amps, 240 Volts as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply in replacement of MCB, TPN, 40 Amps, 415 Volts as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply in replacement of MCB, TPN, 63 Amps, 415 Volts as per IS/IEC 60898-1 2002, IP-20 Protected terminals complete all as specified and as directed.
Supply in replacement of sheet metal enclosure with socket plug top, single pole and neutral enclosure with two pin earth plug and socket complete with one MCB, SP, 20 Amp capacity, 2P+E complete all as specified and as directed.
Supply in replacement of PVC angle holder comprising of chromium plated brass bell mouth connectors two Nos with back plate including 10 Watt, 230 Volts, LED Bulb complete all as specified and directed.
Supply in replacement of MCB DB double door, SPN, 16 Way with 100 Amp Cu bus bar, suitable for Flush Mounting and Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
Supply of Hammer /Hilty type Drilling & Chiselling Machine, Electric Operated, 1-ph, 720 watt, 230 V, RPM - 1500 capacity with Reverse/ Forward/ Hammering operation including a set of all sizes of drill bits as per sample given complete all as specified and directed.
Supply of PVC Flexible spiral conduit pipe of 25 mm dia complete all as specified and directed.
All as per item ser No. 106 above but 32 mm dia
Supply of PVC Junction Boxes (1 to 4 way) suitable for 20 mm dia PVC Conduit including nut-bolts and washers etc complete all as specified and directed at site.
All as per item srl No. 108 above but suitable for 25 mm dia PVC Conduit.
Supply in replacement of Phenolic Laminated sheet cover of size (5x5), suitable for fixing including cutting slots for Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of Phenolic Laminated sheet cover of size (8x5), suitable for fixing including cutting slots for Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of Phenolic Laminated sheet cover of size (13x8), suitable for fixing including cutting slots for Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of GI Sunken box of size (5x5), suitable for fixing of Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of GI Sunken box of size (8x5), suitable for fixing of Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of GI Sunken box of size (13x8), suitable for fixing of Switch/sockets, piano type as per site requirement complete all as specified and directed.
Supply in replacement of Metal Clad Industrial Plug Top 20 Amp, 2 Pin + E, 240 Volts, complete all as specified and directed.
Supply in replacement of Metal Clad Industrial Socket Outlet 20 Amp, 2 Pin + E, 240 Volts, complete all as specified and directed.
Supply in replacement of PVC saddle suitable for clamping of 20 mm dia PVC conduit pipe on any type of wall complete all as specified and directed.
Supply in replacement of PVC saddle suitable for clamping of 25 mm dia PVC conduit pipe on any type of wall complete all as specified and directed.
Supply of Wooden Plank of size (45x45) cm and 25 mm thick suitable for fixing of Exhaust Fan with suitable size of fastners etc on any type of wall/ Window etc complete all as specified and directed.
Supply of Electric Operated Angle Grinder, 1-ph, 230 Volts, Heavy duty, professional type hand operated complete all as specified and directed. Make : Bosch GWS 600
Supply of Self Support bi-pod Aluminium Ladder, 8 Feet height and 7 steps, suitable /compatible for climbing from both side of ladder complete all as specified and directed.
Supply in replacement of Industrial Bulk Head light 10W, 230 Volts having IP65 design with Aluminium die cast housing complete all as specified and directed by Engr-in-Charge.
Supply in replacement of Fan Rod of 1.5 Feet Long suitable for hanging of Ceiling Fan complete all as specified and directed.
Supply in replacement of decorative wall lamp, fency type including 15 Watt, 230 Volts, LED Bulb complete all as specified and directed.
Supply in replacement of three core, copper conductor cable, 3x2.5 Sqmm size, multistranded, Flat/Round type, PVC insulated, FRLS, 1100 Volt grade complete all as specified and as directed.
Supply in replacement of three core, copper conductor cable, 3x4.0 Sqmm size, multistranded, Flat/Round type, PVC insulated, FRLS, 1100 Volt grade complete all as specified and as directed.
Supply in replacement of three core, copper conductor cable, 3x6.0 Sqmm size, multistranded, Flat/Round type, PVC insulated, FRLS, 1100 Volt grade complete all as specified and as directed.
Supply in replacement of high power LED 70W, die cast aluminium housing flood light suitable for highlighting architectural features and general purpose lighting complete all as specified and as directed.
Supply in replacement of high power LED 100W, die cast aluminium housing flood light suitable for highlighting architectural features and general purpose lighting complete all as specified and as directed.
Supply in replacement of Street Light high power LED 70W, 230 V, IP-66 protection, made up of pressure die cast aluminium housing Street Light for general purpose lighting, suitable for fixing/clamped on 80 mm dia size pole complete all as specified and as directed.
Supply in replacement of Post Top, high power LED 25W, 230 V, IP-65 protection, energy saving, environmetal friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire, suitable for fixed on 75 mm dia pole complete all as specified and as directed.
Supply in replacement of PVC insulated 35 Sqmm FRLS single core bright annealed bare copper conductor heavy duty unsheathed multistranded cable 1100 Volts grade with required size of copper lugs including taking down existing one complete all as specified and directed.
Supply in replacement of PVC insulated 50 Sqmm FRLS single core bright annealed bare copper conductor heavy duty unsheathed multistranded cable 1100 Volts grade with required size of copper lugs including taking down existing one complete all as specified and directed.
Supply in replacement of MCB DB Single door, SPN, 2 Way, suitable for Flush Mounting and Surface mounting complete all as specified and as directed.
Supply in replacement of MCB DB double door, SPN, 4 Way with 100 Amp Cu bus bar, suitable for Flush Mounting and Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
Supply in replacement of MCB DB double door, SPN, 16 Way with 100 Amp Cu bus bar, suitable for Flush Mounting and Surface mounting, IP 43, IK-09 as per IEC 61439-3 complete all as specified and as directed.
Supply in replacement of MCCB 4 Pole, 415 Volts, 160 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply in replacement of MCCB 4 Pole, 415 Volts, 200 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply in replacement of MCCB 4 Pole, 415 Volts, 250 Amp, 25 KA Breaking capacity with adjustable Thermal and adjustable Magnetic overload protection with Ics = 100% of Icu including suitable size of spreader links on both side and galvanised or cromium plated high tensile nuts, bolts and washers etc complete all as specified and directed.
Supply in replacement of Sheet Metal Enclosure for TPN DB's IP-43-IK-09 double door, 415 Volts VTPN DB, 8 way with 250 Amp copper busbars and provn for DPX^3 160 MCCB as incomer and SP/TP MCB's as outgoing complete all as specified and directed.
All as per item srl No. 141 above but suitable for 32 mm dia PVC Conduit.
Supply in replacement LED Recess Mounted back-lit Type, 36 W, White/Worm White Colour, 5700K/3000K, LED 2 x 2 feet tile in CRCA housig with full opal diffuser suitable for Armstrong / Grid Ceiling including Electronic Chock, pre-wired for connection etc complete all as specified and directed. Orient Cat Part No. LTRAQ-36-C-V0
Supply in replacement LED Surface Mounted back-lit Type, 36 W, Pure White Colour, 5700K, LED 2 x 2 feet tile in CRCA housig with full opal diffuser for soft and glare-free light distribution including Electronic Chock, pre-wired for connection etc complete all as specified and directed. Orient Cat Part No. LTSAQ-36-C-V0
Supply in replacement of Metal Clad Industrial Plug Top 10 Amp, 2 Pin + E, 240 Volts, complete all as specified and directed.
Supply in replacement of Metal Clad Industrial Socket Outlet 10 Amp, 2 Pin + E, 240 Volts, complete all as specified and directed.
Supply in replacement of PVC saddle suitable for clamping of 32 mm dia PVC conduit pipe on any type of wall complete all as specified and directed.
Supply of Wooden Plank of size (60x60) cm and 25 mm thick suitable for fixing of Exhaust Fan with suitable size of fastners etc on any type of wall/Window etc complete all as specified and directed.
Supply of GI /Cromium plated fastners of 12 mm dia size and 100 mm long suitable for fixing of Exhaust Fan, Geysers and Ceiling Fan etc complete all as specified and directed.
M & L in replacement of GI Earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level in any type of soil strata, connected to galvanized iron strip 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 3 of MES schedule 1991 Part – I connected to machinery/equipment for LT Panel, Feeder Pillars, Sub Feeder Pillars etc. as required including necessary excavation and earth work, concrete pit, chamber and pit cover in PCC 1:2:4 type B1 including lifting handle and Earth lead and 20mm Dia GI watering pipe medium grade, Funnel, wiremesh etc. complete all as specified and directed by Engr-in-Charge including testing on completion.
Supply in replacement for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed on HT/LT Poles with M.S. clamps, bolts and nuts of required size, for 11000/440 Volts HT/LT of size 200 X 150mm complete including taking down existing one complete all as directed.
Supply in replacement of SMC Junction box inner dimensions (270 x 225 x 135)mm (LxBxD), 3 phase 4 wire system, including cable connecting base, 6 Amp DP MCB with mounting SS railing, Cable lugs suitable to 10/16 Sqmm 4 core cable, connection for incoming and outgoing cables including Fixing arrangement on pole etc complete all as specified and directed by Engr-in-Charge.
Comprehensive maintenance of electrically/automatically operated MRL, gearless, 12 passenger (1000 Kgs) good cum passanger Lift, having of 03 stops and 03 opening catered to serve from G+2 th floor , Make: M/s KONE of 'Old building multistories building at DPL complex ARC bldg including machine room and electrical palel with checking, servicing,inspection, preventive/periodical, routine & corrective maintenace, cleaning, and including repair/ replacement of defective components/parts/fittings complete all as specified below and as directed by Engr-in-Charge.
Comprehensive maintenance of electrically/ automatically operated, geared, 1000Kg goods Lift, having of 05 stops and 05 opening catered to serve from G+4 th floor, Make: M/s Johnson of 'ARMIS' Block multistories building at DPL complex ARC bldg including machine room and electrical panel with checking, servicing, inspection, Preventive/periodical, Routine & Corrective maintenance, cleaning, including repair/ replacement of defective components/parts/fittings complete all as specified below and as directed by Engr-in-Charge.
Notes: For Sch 'A' Item No 153 to 154:- The comprehensive maintenance comprises, repair/replacement/maint of all major/minor spares/ parts for repair of machine roon/Lift car cabin and LT panel etc including T&P for any specific work required for Lifts as indicated under Srl Item No. 01 to 02 above to keep the Lifts in perfect serviceable condition shall be deemed in the above quoted rate by the contractor. If lift technician of OEM will not visit the site to check proper functioning of lift in each month then a sum of Rs 500/ per day will be penalised and the same will be deducted from contractor dues. 2. The contractor shall have to submit the copy of MOU with respective OEM (M/s KONE and M/S Johnson) or its authorized dealer to carry out the preventive and comprehensive maintenance and repair including renewal, replacement of defective parts of passenger/goods/service lifts at DPL Complex. 3. MOU between respective firms and the contractor will be obtained and it will be the part of Tender documents. 4. The work for Repair/ Maint/replacement of parts will be carried out as per modern engineering practice by the authorised company having MOU with OEM. 5. Diagnose the fault and rectify the defects in reasonable time. The contractor penalised @ Rs 2000 /- per day if he fails to attend and rectify the minor defect with in 24 hrs and @5000/ per day if he fails to attend and rectify the major defect with in 48 hrs of lodging the complaints either personally or telephonically. In this regard, the decision of Engr-in Charge shall be final & binding.
6. Scope of Annual Comprehensive Maintenance are cover under this tender:- (a) Diagnose the fault and rectify the defects detected in reasonable time. (b) Repair/ replace the faulty minor and major parts etc. of the equipments. (c) To ensure that alarm and intercom system are always working in case of emergency. (d) To ensure sufficient illumination in car always by replacing LED lights as and when required. (e) To ensure car cabine fan always in working condition by replacing air circulating Fan in car cabin as and when required. (f) Carry on the servicing, routine/periodical and preventive maintenance, as per schedule mention under particular specification. (g) All periodical and preventive maintenance shall be carried out in presence of OEM Engineer and report (h) Attend all break down as and when required. (j) Upkeep the system, recording, required reading and maintenance of log Book of works carried out. (k) Clean the car cabin, lift pit, car top, landing and car doors and machine room etc.
7. The sevicing, routine/periodical and preventive maintenance shall be carried out as per technical instructions of OEM. 8. Upkeep the system, recording, required reading and maintenance of log Book of works carried out. 9. Clean the car cabin, lift pit, car top, landing and car doors and machine room etc. The contractor shall be responsible to reinstate and make good at his own expense if any damage casused by his workmanship to existing building/ equipments/ Machineries and connected accessories complete. 10, The contractor and OEM of lift shall be responsible to bear the cost of casulty/ accident/ damage of equipment/human life due to improper functioning of lift. 11. Cost of all the maintenance, repairs in and including replacement of any minor/major materials/components/parts including labour that too for the specific Lifts as indicated under Srl Item No. 1 to 2 above to keep the Lifts in perfect serviceable condition and the rate quoted shall be deemed to be included in the quoted rate of the contractor. 12. The tenderer shall have to submit the copy of MOU with OEM Elevator or its authorized dealer to carry out the preventive and comprehensive maintenance and repair including renewal, replacement of defective parts of passenger/goods lifts at Cab Sectt. 13. MOU between OEM/authorised dealer and the contractor will be obtained and it will be the part of Tender documents and contractor should submit the agreement with OEM/authorised dealerat the time of commencement of the work at site to EIC. 14. Maint will be done by the authorised company having MOU with OEM.
15. Scope of Annual Comprehensive Maintenance are cover under this tender:- (a) Diagnose the fault and rectify the defects detected in reasonable time. (b) Repair /replace the faulty minor and major parts etc. of the equipments. (c) To ensure that alarm and intercom system are always working in case of emergency. (d) To ensure sufficient illumination in car always by replacing LED lights as and when required. (e) To ensure car cabine fan always in working condition by replacing air circulating Fan in car cabin as and when required. (f) Carry on the servicing, routine/periodical and preventive maintenance, as per schedule mention under particular specification. (g) Attend all break down as and when required. (h) Clean the car cabin, lift pit, car top, landing and car doors and machine room etc.
17. The servicing, routine/ periodical and maintenance shall be carried out as per technical instructions by OEM. 18. Upkeep the system, requiredreading and maintenance of log Book of works carried out. 19. The contractor and OEM of lift shall be responsible to bear the cost of casulty/ accident/ damabe of equipment/humal life to imprper functioning of lift. 20. The contractor shall be responsible to handing over the lifts in serviceable condition in the time of completion of works duly inspected by Engineer of OEM and Engr-in Charge jointly and inspection report of serviceabilty state of each and every parts of lifts to be submitted with final bill.
Comprehensive maintenance of electrically/ automatically operated MRL, gearless, 13 passenger (884 Kgs) Lift, having of 03 stops and 03 opening catered to serve from G+2 th floor, Make: M/s KONE of 'Adm ' Block multistories building at Tag location of Cabinet Sectt including machine room and electrical palel with checking, servicing,inspection, Preventive/periodical, Routine & Corrective maintenace , cleaning, and including repair/ replacement of defective components/parts/fittings complete all as specified below and as directed by Engr-in-Charge.
Comprehensive maintenance of electrically/automatically operated, geared, 1000Kg good Lift, having of 04 stops and 04 opening catered to serve from G+3 th floor, Make: M/s OMEGA of 'NTB ' Block multistories building at Tag location of Cabinet Sectt including machine room and electrical panel with checking, servicing, inspection, Preventive/periodical, Routine & Corrective maintenance, cleaning, including repair/ replacement of defective components/parts/fittings complete all as specified below and as directed by Engr-in-Charge.
Notes: For Sch A'Item No 155 to 156:- 1. OEM will detail Lift technician to check proper functioing of the lift with in a duration of one month and take action for repair/replacement/maint of all major/minor spares/ parts for repair of machine roon/Lift car cabin and LT panel etc including labour that too for the specific Lifts as indicated under Srl Item No. 01 to 02 above to keep the Lifts in perfect serviceable condition shall be deemed in the above quoted above quoted rate by the contractor. If lift technician of OEM will not visit the site to check proper functioning of lift in each month then a sum of Rs 500/ per day will be penalised and the same will be deducted from contractor dues. 2. Cost/rate of all major/minor spares/parts for repair / replacement of Lifts with machine room and LT panel including labour that too for the specific Lifts as indicated under Srl Item No. 01 to 02 above to keep the Lifts in perfect serviceable condition shall be deemed in the above quoted rate by the contractor. 3. The contractor shall have to submit the copy of MOU with OEM i.e. M/s KONE and OMEGA Elevator or its authorized dealer to carry out the preventive and comprehensive maintenance and repair including renewal, replacement of defective parts of passenger/goods/service lifts at Cab Sectt. 4. MOU between M/s KONE and OMEGA Elevator and the contractor will be obtained and it will be the part of Tender documents. 5. The work for Repair/ Maint/replacement of parts will be carried out as per modern engineering practice by the authorised company having MOU with OEM.
6. Diagnose the fault and rectify the defects in reasonable time. The contractor penalised @ Rs 2000 /- per day if he fails to attend and rectify the minor defect with in 24 hrs and @5000/ per day if he fails to attend and rectify the major defect with in 48 hrs of lodging the complaints either personally or telephonically. In this regard ,the decision of Engr-in Charge shall be final & binding. 7. Scope of Annual Comprehensive Maintenance are cover under this tender :- (a) Diagnose the fault and rectify the defects detected in reasonable time. (b) Repair /replace the faulty minor and major parts etc. of the equipments. (c) To ensure that alarm and intercom system are always working in case of emergency. (d) To ensure sufficient illumination in car always by replacing LED lights as and when required. (e) To ensure car cabine fan always in working condition by replacing air circulating Fan in car cabin as and when required. (f) Carry on the servicing, routine/periodical and preventive maintenance, as per schedule mention under particular specification. (g) All periodical and preventive maintenance shall be carried out in presence of OEM (M/S OITS) Engineer and report (h) Attend all break down as and when required. (j) Upkeep the system, recording, required reading and maintenance of log Book of works carried out. (k) Clean the car cabin, lift pit, car top, landing and car doors and machine room etc.
Notes: For Sch A'Item No 155 to 156 (cost of these shall be deemed to be included in the quoted rate of the contractor):- 1. Cost of all the maintenance, repairs in and including replacement of any minor/major materials/components/parts including labour that too for the specific Lifts as indicated under Srl Item No. 1 to 5 above to keep the Lifts in perfect serviceable condition and the rate quoted shall be deemed to be included in the quoted rate of the contractor. 2. The tenderer shall have to submit the copy of MOU with OEM i.e. M/s OTIS Elevator or its authorized dealer to carry out the preventive and comprehensive maintenance and repair including renewal, replacement of defective parts of passenger/goods lifts at Cab Sectt. 3. MOU between OTIS and the contractor will be obtained and it will be the part of Tender documents and contractor should submit the agreement with OEM at the time of commencement of the work at site to Engr-in-Charge. 4. Maint will be done by the authorised company having MOU with OEM.
5. Scope of Annual Comprehensive Maintenance are cover under this tender:- (a) Diagnose the fault and rectify the defects detected in reasonable time. (b) Repair /replace the faulty minor and major parts etc. of the equipments. (c) To ensure that alarm and intercom system are always working in case of emergency. (d) To ensure sufficient illumination in car always by replacing LED lights as and when required. (e) To ensure car cabine fan always in working condition by replacing air circulating Fan in car cabin as and when required. (f) Carry on the servicing, routine/periodical and preventive maintenance, as per schedule mention under particular specification. (g) All periodical and preventive maintenance shall be carried out in presence of OEM (M/S OITS) Engineer and report (h) Attend all break down as and when required. (j) Upkeep the system, recording, required reading and maintenance of log Book of works carried out. (k) Clean the car cabin, lift pit, car top, landing and car doors and machine room etc.
7. Scope of Replacement of following are cover under this tender:- (a) Replacements of COP and HALL Panels lifts except with touchesless operation COP and HALL panels with all existing parameters/operation of all Lifts mentioned under Srl No. 155 and 156.
8. The servicing, routine/ periodical and maintenance shall be carried out as per technical instructions by OEM. 9. Upkeep the system, requiredreading and maintenance of log Book of works carried out. 10. The contractor shall be responsible to reinstate and make good at his own expense if any damage caused by his workmanship to existing building/Equipments/Machineries and connected accessories complete. 11.The contractor and OEM of lift shall be responsible to bear the cost of casulty/ accident/ damabe of equipment/humal life to imprper functioning of lift. 12. The contractor shall be responsible to handing over the lifts in serviceable condition in the time of completion of works duly inspected by Engineer of OEM and Engr-in Charge jointly and inspection report of serviceabilty state of each and every parts of lifts to be submitted with final bill.
P S TRADERS (BID ID -3108949)
M/s Dhapola Elevator and Engineering (BID ID -3109202)
JYOTI CONTRACTORS AND TRADERS (BID ID -3107570)
Surjit and Sons (BID ID -3121104)
VINAY ENTERPRISES (BID ID -3107493)
SETHI ENTERPRISES (BID ID -3106924)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .