Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 161 VPO RAJLU GARHI GANAUR 131101 | SONIPAT | HARYANA | 131101 | ₹1.7 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹1.9 Cr+₹22.0 L (13.0%)Rejected-AOC 464 21 NEW ANAJ MANDI TOHANA 125120 | FATEHABAD | HARYANA | 125120 | ₹1.9 Cr+₹22.0 L (13.0%) | L2 | Rejected-AOC Rejected |
Tender Value
₹2.0 Cr
EMD Value
₹4.0 L
Closing Date
4 Oct 2023, 4:00 pmClosed
TARUN Garg
EE PHE Division No. 2 Rohtak
Const. of Raw Water pumping station, laying of DI raw water rising main from pumping station to water works, Const. of 1 No. additional SandS tank, Renovation / up-gradation of existing structures and pumping machineries, laying the balance pipe lin
2023_HRY_312955_1
202312B598E9 249D 42B7 87CB 3E666F1B782C577PUH
Open Tender
Civil Works
Works
365 days
BHAINI MAHARAJPUR
2 documents required · 2 mandatory
₹15,000
₹4.0 L
Yes
7 Dec 2023
19 Sept 2023
4 Oct 2023
19 Sept 2023
4 Oct 2023
19 Sept 2023
Amount
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 20 HP power Motor
`Copper conductor: Supply, erection, testing and commissioning of IS marked 3 core copper wire with accessories like thimble lugs etc for motors in trenches or underground in PVC and flexible pipes as per entire satisfaction of Engineer-in-charge complete in all respect. ` 25mm2 3core
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 5 HP power Motor
`RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 500 LPM X 12 M X 5.0 HP
`RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 1900 LPM X 20 M X 15.0 HP
Water treatment plant (WTP) designing, testing, commissioning of 0.50 MLD capacity water treatment plant including inlet channel alum dozing, flansh mixing, clari floculator, filter box, over head resrvoid for back wash, waste water tank, including all civil work pumping machinery and electric cabling control panel, entire piping network of suitable size laying of DI pipes from raw water pump 0 to inlet box of WTP, WTP to CWT & Suction well for CW including, DI specials suitable size of sulice valve hodies manhole covers air scour equipment, chemical house including chlorination equipment and arrangment of flow measurement and sand bed with autromation complete in all respects as approved NIT. (Sluice valve of make (IVCAWAG).
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for 1 Non clog Submersible Pumping a) Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 15 HP power Motor
Supply erection testing of standard make XLPE 3 core galvanized steel trip armored HT / 11 KV grade ISI marked cable with aluminum Conductor in ground covered with sand and brick in trenchs in pipes for making following connection a) from DHBVN G.O switch to metering equipment . b) from metering equipment to transformer complete in all respect . 50mm2 3core
Operation and Maintenance for complete scope of work mentioned in the DNIT (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run period will be charged to the A/Mtc. estimate complete in all respect as per approved NIT. (i) Operation and Maintenance during defect liability period (Operation only) after 3 month trial run period.
(ii) Operation and Maintenance during 1st year after defect liability period.
(iii) Operation and Maintenance during 2nd year.
(iv) Operation and Maintenance during 3rd year.
(v) Operation and Maintenance during 4th year.
(vi) Operation and Maintenance during 5th year.
Bidder Name
Amount
Sunil Kumar(GSTN-06BMGPK6616K1ZU)
RAJKUMAR(GSTN-06BMEPK8901M1ZS)
Sunil Kumar
Sunil Kumar
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .