Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹49.0 L+₹6.3 L (14.8%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹50.7 L+₹8.0 L (18.6%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹53.5 L+₹10.8 L (25.3%)Rejected-Finance NO 1 1ST MAIN ANANDNAGAR ATRIA INSTITUTE OF TECHNOLOGY CAMPUS HEBBAL BANGALURU 560 024 | BENGALURU URBAN | KARNATAKA | 560024 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹53.9 L+₹11.2 L (26.2%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Aug 2022, 6:00 pmClosed
GE North Bangalore
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS TO TOILET AND PLASTERING IN OTM ACCN AND REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS N FIXTURE OF TB 1 TB III OF MEG AREA UNDER AOR OF AGE MEG UNDER GE N BLORE
2022_MES_533071_1
8309
Open Tender
Civil Works
Item Rate
150 days
BLORE
Class D Category a(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹90,000
Yes
3 Sept 2022
23 Jun 2022
6 Aug 2022
23 Jun 2022
4 Aug 2022
13 Jul 2022
23 Jun 2022 - 12 Jul 2022
Amount
(B/R PORTION)
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings including ridges etc complete all as specified and as directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position as in Framed work etc complete all as specified and as directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc complete all as specified and as directed
Demolition of brick work /stone masonry/PCC block masonry built in cement mortar of any description all as specified and directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description & in any position not specifically provided for complete all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and as directed
Dismantling of Stone set paving of any description or thickness in floors, aprons etc (Laid bedded and pointed in any cement mortar) incl removing off the premises etc complete all as specified and as directed
Taking down cement plaster of any description hacking for key or raking out joint on old brick work/stone/concrete surface etc complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) not exc. 1.5 sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
Taking down chowkats or frames with shutters (without taking off shutter from frames) exc. 1.5 Sqm but n exc 4 Sqm each, including cutting holes for removing the hold fast etc (Distrubed surface of wall shall be make good by the contractor. The rate quoted shall be deemed included for the same) complete all as specified and as directed
Taking down steel tubing & connections including cleaning for refixing serviceable pipe or removal balance pipe of 15 mm dia bore complete all as specified and as directed
All as per item No 1.012 above but 20 mm dia bore
All as per item No 1.012 above but 25 mm dia bore
Dismantling of cast iron or reinforced concrete drain/PVC soil waste pipe up to 150mm dia incl fittings, jointed in cement mortar and taking out trenches if reqired etc complete all as specified and directed
Dismantling water tanks exc 500ltr but not exc 1000 ltr and removing to store etc complete all as specified and as directed
All as per item no 1.016 above but exc 1000 ltr & not exc 2000 ltr capacity
M&L Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates confirming to Fe 410 -W (Gde- E- 250) quality-A etc including box section etc complete all as specified and as directed
S&F Hollow steel section for structural use in beams, col, rafter purlins or other connecting plates incl necessary welding, riveting, nut bolts as per IS-4923 etc complete all as specified and as directed
M&L Hollow /solid steel section for structural as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to IS-4923 etc complete all as specified and as directed
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/ cladding to wall, fixed with self tapping screws etc complete all as specified and as directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 MPA as in roof covering/cladding/redges / valley to wall, fixed with self tapping screws etc complete all as specified and as directed
M&L for 75 mm thick cement concrete type D- 2, 1:4:8 (40mm graded aggregate) as in sub base of flooing etc complete all as specified and as directed
M&L for 25 mm thick Cement concrete type B-0,1:2:4 (12.5mm graded aggregate) as in levelling course of flooing etc complete all as specified and as directed
M&L for screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm,, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed
M&L for Matt Finished Non - skid Ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match etc complete all as specified and as directed
M&L for screed bed or bedding layer of mortar 20mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 18-20mm thick, (table rubbed) (moulded exposed edge) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and as directed
M&L for 18 to 20mm thick granite Granite stone slab (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granit including grinding the edges half round and polishing including etc complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surface as backing coat of dado / skirting etc complete all as specified and as directed
M&L Glazed ceramic coloured tiles 300X450X7mm thick as in skirting / dado, set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as specified and and as directed
M&L for Machine cut kota stone slab 18-20mm thick, (table rubbed) (moulded exposed edge), in riser of treads, skirting, dado , over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc complete all as specified and as directed
M&L for 75 mm thick PCC 1:3:6, type C-1, using 20 mm graded aggregates as in plinth protection etc, finished even and smooth without using extra cement complete all as specified including joints filling with sealing compound Grade "A" complete all as specified and directed.
M&L for exterior grade, coloured glossy finish rubber pressed, cement concrete designer chequered tiles of size 30cm x 30cm x 25mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment to match the shade / colour / matrix of tiles as in floor etc. complete all as specifed and as directed
M&L for M Sand Cushioning for Paving Block tiles etc complete all as specified and directed
M&L for machine presssd pre-cast concrete interlocking coloured paving Block of glass fibre reinfoced glossy finished vibro compacted any shape and size confirming to IS-15658-2006 of 60 mm thick, M-35 grade to match with grey cement and pigment etc complete all as specified and as directed
M&L Pre-cast Cement concrete Type 1:3:6 using (20 mm graded stone aggregates) with solid blocks, exc 10 cm in width and setting in CM 1:6 all as specified and directed.
M&L for rendering for ceiling 5 mm thick in CM 1:3 on fair faces of brick work or concrete surface finished even and smooth without using extra cement etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:6) on fair faces of brick work or concrete / Stone masonry surface finsihed even and smooth (without using extra cement) etc complete all as specified and as directed
M&L for rendering 15 mm thick in CM (1:4) on other fair faces of brick work or concrete/stone masonry surface finsihed even and smooth (without using extra cement) mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M&L for rendering 10 mm thick in CM (1:3) on fair faces of brick work or concrete surface mixed with water proofing compound as per manufacture instruction etc complete all as specified and as directed Notes : WPC shall be measured and paid seperately
M&L for removing all loose gravel, dirt, oil, grease and foreign materials by jet or dry air, cleaning the surfaces mechanically or by grinding to make it smooth and APP modified water proofing membrane as per IS 1654-2017/IS 16352-2017, 3mm thick and weighing not less than 3.60kg/Sqm reinforced with non woven polyster/HMHDPE matt black finished over compatible primer/bonding bitumen @ 0.40 Litr/Sqm and torch applications of membrane with 75mm side overlap and 100mm end lap after necessary preparation of surface complete as per manufacturer's instructions and applying a coat of solar reflective bituminous aluminum paint on top @ 0.10 litre/sqm complete all as specified and directed incl taking down existing roof treatment of any types incl HP clay tiles etc along with cement plastering etc incl removing of debries exc 1.50 Km etc complete all as specified and directed.
M&L providing cement concrete type B0 1:2:4 (12.50mm graded stone aggregate) in copings, parapets and railing upto 60cm height, leveling concrete for Roof slab, kerbs, water troughs/Chajjas and the like including weathering, slightly rounded or chamfered angles and throating as directed
Supply only liquid water proofing compound
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete shall as specified and as directed
S&F Powder Coating (minimum thickness of powder coating 50 micron) aluminium ventilator shutters, fixed type /sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as specified etc. complete shall as specified and as directed
S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares in not. exc 0.5 sq.m in each pane etc omplete all as specified and as directed
S&F for solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete as sepecified and directed (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick (Stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm plain colour PVC sheet on back face etc. complete all as specified and as directed.
S&F 150 mm long Aluminium anodised tower bolt of extruded section etc complete all as specified and as directed
S&F 100 mm thick stainless steel butt hinges, heavy weight, and fixed etc complete all as specified and as directed
S&F 150 mm long aluminium handle, cast type, anodised etc complete all as specified and as directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed
M&L Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for flat rough finished surfaces of concrete complete all as specified and directed.
M&L RCC (Nominal mix) type A-1, 1:1.5:3 (20mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified and directed.
M&L for Providing precast cement concrete Type B-1 1:2:4 (20 mm graded stone aggregates) as in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in CM 1:6 etc complete
M&L for TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, or securing with clips etc complete all as specified and as directed
S&F 16mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified.
All as per item No 1.059 above but 20 mm dia of bore pipe
All as per item No 1.059 above, but 25 mm dia of bore pipe
M&L rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I capacity of tank 2000 ltrs complete all as specified and directed
All as per item 1.062 above, but 1000 ltr capacity
S & F 25 mm dia of bore ball float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe complete all as specified and as directed [Minimum weight for 20 mm – 210 gms].
S & F in repairs 25 mm gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipe and including taking down old gate valve all as specified and as directed.
S&F in repairs vitreous china wash basin white, flat back, size 550 x 400mm excluding taps, waste, chain & plug and porcelain stopper but including brackets, 32 mm bore waste stainless steel coupling and LDPE pipe 600 mm long complete all as specified and directed.
S & F in repair vitreous china wash down water closet pan (Pedestal Pan) including fixing bolts, flush pipe anti syphonage pipe, plastic water closet seat , black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device etc complete of cera model cat pt no. 2008 incl plastic EWC seat cover, coloured closed pattern with flat bottom and cover of cera model cat pt 2308 and mild steel chromium plated or aluminised hinging device etc complete all as specified and as directed
S&F in repairs viterous china squatting pan orrisa pattern of size 580X440 mm white with integral foot rest 'P' trap including connecting to trap incl S trap or P trap and flush pipe anti-symphonage pipe etc complete all as specified and as directed
S&F in repairs Viterous China urinals, bowl type (back or corner wall type), complete fixed in repairs including providing and fixing plugs, beddings urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe.
S&F in repair PVC flushing cistern with flush out valve low level of 10 Ltr capacity white with inlet ball valve, float, flushing bend & handle including brackets, etc complete all as specified and as directed
S&F in repair 15mm dia Pillar tap PTMT fancy type any long body colour screwed, for iron pipe etc complete all as specified and as directed
S&F in repair 15 mm bore dia Bib tap fancy type long body standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 120gms)
S&F in repairs 125 mm dia bore Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms)
S&F in repair 15mm dia stop cock / angle / Concealed cock PTMT fancy type any colour screwed, for iron pipe and fixed etc complete all as specified and as directed
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm, all as specified and as directed.
S&F PVC urinal waste pipe 32mm dia 800mm long, complete all as specified and directed
S&F in repairs 75 mm dia bore PVC (SWR) multi floor trap with grating including jointing with solvent cement etc complete all as specified and as directed
S&F in repairs for Grating doom 100 mm dia of PTMT (Minimum weight 25 gms) complete all as specified and directed.
S&F in repairs soap dish holder with glass etc complete all as specified and as directed (Make Cat no BA-25G of Prayag of equlavent make of Cera)
S&F in repairs Hand shower (Health faucet) (ABS Body) with 8 mm dia, 1.20 mtr long flexible tube & wall hook etc complete all as specified and as directed Prayag of equlavent make of Cera)
S&F in repairs SS Grab bar Towel rail 450 mm long incl fixing arrangement etc complete all as specified and as directed (Make Cat no GM-04 of Prayag of equlavent make of Cera)
S&F 110mm PVC, SWR pipes, single socketed in any length with rubber ring joint leaid in trenches or in floor complete all as specified and directed
All as per item No 1.083 above but fixed with wall complete all as specified and directed
S&F 75mm PVC, SWR pipes, single socketed in any length with rubber ring joint leaid in trenches or in floor complete all as specified and directed
All as per item No 1.085 above but fixed with wall complete all as specified and directed
S&F PVC bends (any radius) of 110mm dia with access door etc complete all as specified and as directed
S&F 110 mm dia PVC Brach Pieces double (double Y) equal or unequal of 110mm dia etc complete all as specified and as directed
S&F 110 m dia PVC (SWR) junction single, (Single T) equal or unequal etc complete all as specified and as directed
S&F PVC vent cowls of 110mm dia etc complete all as specified and as directed
S&F PVC bends (any radius) of 75mm dia with access door etc complete all as specified and as directed
S&F PVC (SWR) junction single, (Single T) equal or unequal etc complete all as specified and as directed
M&L for preparing new plastered surface of ceiling and applying three coat of white wash etc complete all as specified and as directed
M&L for preparing new plastered surface of wall and applying three coat of white wash etc complete all as specified and as directed
M&L for preparing newely plastered surface of wall and applying two coat of cement base paint over a coat of primer etc complete all as specified and as directed
M&L for Preparation of new steel and iron surfaces of any description, over 10 cm in width or girth, not otherwise described and painting with two coats of synthetic enamel paint over a coat of red oxide primer etc complete all as specified and as directed
Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard / dese soil etc complete all as specified and as directed
Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm etc complete all as specified and directed
Removal of excavated materials not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting points etc complete all as specified and directed
M&L for Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished ,and reforming benching as required for 150 mm internal dia of pipe complete all as specified and directed.
M&L for 15 mm thick in cement mortar 1:3 mixed with water proofing compound and finished even and smooth without using extra cement on concrete slab and sides of sunken portion etc complete all as specified and as diredted
M&L for applying a uniform coat of blown grade bitumen VG-10 @ 1.20 Kg. Sqm confirming to IS-702 over a coat of primer @0.70 Kg/ Sqm over concerte slab and sides of sunken portion etc complete all as specified and as direction
M&L for providing water proofing treatment to sunken portion of WCs, bathroom etc by applying cement slurry mixed with two component Elastomeric Acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003. The following procedures to be adopted during the execution of work :- (i) First layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm. The layer will be allowed to air cure for 4 hours. (ii) Second layer of slurry of cement @ 0.242 kg/sqm mixed with with Acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm. The layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iii) 20mm thick screed in cement mortar 1:3 mixed with liquid water proofing compound. (iv) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall.
M&L cement concrete 1:5:10 type E-2 using 20mm granded brick aggregates as in sunken portion of WC etc complete all as specified and as directed
Removing building materials etc. (other than spoil) beyond the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed
(E/M PORTION)
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan, call bell socket or power circuits), without taking out switches, sockets, regulators, light fittings, etc., complete and making good the disturbed surface of walls, ceiling etc incl painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Concealed Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concealed in walls incl MS terminal boxes fabricated with 1.6 mm thick MS sheet, covering with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.002 here-in-above, but for one light point controlled by two way swtich
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.002 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Concealed Point Wiring (For modular type switch & sockets) complete with 1.5 Sq mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit medium grade ISI marked incl accessories concelaed type wiring incl GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.006 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.006 here-in-above, but for one 3 pin socket outlet 5 Amps on Same Board.
Material and labour for Point Wiring complete with 1.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC Casing & Caping ISI marked incl accessories surface type wiring incl 1.6 mm thick MS sunken boxes concealed on walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 1.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for One light point controlled by one switch / One fan point controlled by one switch/regulator / one bell/buzzer point controlled by bell push
All as per Serial Item No 2.010 here-in-above, but for one light point controlled by 2 way swtich
All as per Serial Item No 2.010 here-in-above, but for one 3 pin socket outlet 5 Amps on indepenedent board.
All as per Serial Item No 2.010 here-in-above, but for socket outlet 5 Amps on Same Board.
All as per Serial Item No 2.002 here-in-above, but for concealed wiring drawn through including Conduit, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm
All as per Serial Item No 2.014 here-in-above, but with 2.5 Sq mm cable and earth continuity conductor of 2.5 Sq mm Notes for Serial Item Nos 2.002 to 2.015 :- (i) The earth wire for points in the same circuit can be looped from point to point, (ii) Earth wire shall be taken inside the conduit, (iii) Cost of terminal box shall deemed to be included in the item rate quoted for point wiring, (iv) Cost of cable from DB to any switch/ socket board to be included in point wiring. (v) Cutting chases, grooving, etc., required for taking down / providing concealed wiring will be measured and paid for separtely under respective item.
Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2 to 8 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items.
Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl non-metalic PVC conduit medium density ISI marked incl accessories concealed type run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Wiring complete with 2.5 Sqmm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and incl PVC casing caping ISI marked incl incl accessories surface type wiring run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., incl provision of 2.5 Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2 to 8 :- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Cost of cutting chases for conduits and making good to walls, in case of recessed or concealed conduit wiring will be paid separately in other items.
Taking down unserviceable sub main wiring, supply and fixing Sub main wiring using FRLS grade PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable, 2 runs of single core of size 2.5 Sq mm and one run of earth continuity conductor of size 2.5 Sq mm to be drawn through and includin PVC non metallic rigid conduit complete all as specified and as directed. NOTE: - Two runs of 2.5 sq.mm cable, one run of 2.5 sq mm earth wire and PVC conduite shall be measured as one length.
Supply and fix in repairs, Modular Switch, One module, One way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, One way, 16 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, bell push, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular Switch, One module, two way, 6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket, 6 Amps, 5 pin combined, 2 module, 240 Volts all as specified and as directed.
Supply and fix in repairs, Modular socket outlet, 2 Module, 6 pin, 6/16 Amps (multi purpose), complete all as specified and directed.
Supply and fix in repairs, Modular fan Regulator,120 W, electronic stepped type, 230 Volts 2 module, complete all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, One way, SP, 5 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, piano Switch, flush type, two way, SP, 5 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type, bell push, SP, 5/6 Amps, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 5 pin, 2 in 1, 5 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, switch socket combination 3 pin, 2 in 1, 5 & 15 Amps, flush type, 240 Volts all as specified and as directed.
Supply and fix in repairs, flush type socket outlet, 2 in 1, 3 pin 5 Amps, 240 V, complete all as specified and directed.
Supply and fix in repairs, Angle holder, pin type, pvc/polycarbonate made, complete all as specified and as directed by Engineer-in-charge.
Supply and fix in repairs, fan Regulator, 120 W, electronic stepped type, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ding Dong bell, SP, AC, 230 Volts, complete all as specified and as directed.
Supply and fix in repairs, Ceiling rose surface type, Bakelite, 65 x 50 mm ISI marked with three terminals all as specified and as directed.
Supply and fix in repairs, MCB SP, 240 volts, 6 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB SP, 240 volts, 10 to 32 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB TPN, 415 volts, 31 to 63 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Supply and fix in repairs, MCB TPN, 415 volts, 100 Amps, 50 Hz, 10 KA breaking capacity, 'C' Series, using copper lugs for terminations, complete all as specified and as directed.
Taking down unserviceable sheet metal enclosure/ DB, supply and fix, MCB DB SPN 4 way (Horizontal), double door with Sheet metal enclosure, flush mounted, prewired, 240 V, AC, 50 Hz, Factory made, powder coated, IP-42 protection conforming to IS-13032 universal mounting with 200 Amps rated copper bus bar, neutral link, earth link, earthing studs, detachable gland plates with knockouts on both sides, etc complete all as specified and as directed. Notes : i) All unused modules shall be provided with blanking plate for which the cost is deemed to be included in the cost of MCB DBs. ii) MCB/ Isolators will be measured and paid separately as supply and fix under respective items.
All as per Serial Item No 2.040 here-in-above, but SPN 8 ways
All as per Serial Item No 2.040 here-in-above, but TPN 4 ways, 415 V
Supply and fixing in repirs, wall mounted LED batten, energy efficient, 20 Watt, 4 feet, with high lumen output of 2000 lumens and diffuser should be High translucent serrated milky white, environmental friendly, energy efficient LED, with accessories, IP 20 protection Class I, system electrical efficiency > 85%, system efficacy > =100 lm/W, operating voltage between 140 - 270 V, AC, 50 Hz, TDH <20%, power factor ≥ 0.90, surge protection 2.5 kV, colour temperature 5700 K, CRI > 80 & integrated electronic driver 20 W fitting prewired and connecting with 3 Core, 1 sq mm sheathed copper flexible cable complete in all respects all a directed by Engineer-in-charge. Cat Part No BCLAB 20 WH LED Pof Bajaj or techno commercially equivalent makes specified here-in-after complete all as specified.
Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
Removing of old existing and provision of new sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed
S&F LED lamp suitable to fit in angle holder of capacity 09 watt. Make: Bajaj or Equivalent in Philips / Havells / CG.
Supply and fixing 30 W LED bldg security light fitting with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection including taking out old fittings. Make:- Bajaj, Cat No.:- ENXT P 30L WH SY PC SD or Equivalent Makes & model
S&F Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
S&F Exhaust fans AC single phase 230/ 240 V of size 250/280/300 mm sweep with louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as directed.
S&F 2' x 2' Recess mounted LED Luminaire suitable for Gypsum/ grid type false ceiling of capacity 36 Watts white powder coated CRCA housing with LEDs seamless front frame with flate white high transmission arcylic cover complete with all accessories all including taking out old fittings as specified and directed. Make: Bajaj, Cat No : BZRSQL 36W GZI WH / LTCRSLM36WATT2X2 of C & S / HLFPR22-36-CW-R of Halonix
Demolishing of existing earth pits, and providing Material and labour for, earthing complete with Galvanized Iron earth plate electrode 600 mm x 600 mm x 6 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized earth lead wire of 4 mm dia by means of bolts, nuts, Contd/... 2.052
Condt/...2.051 check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery / equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 40 mm bore light grade GI pipe for watering funnel wire mesh, PCC chamber in CC (1:3:6), type C1, manhole cover with RCC (1:2:4), type B1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover and MS frame etc., complete all as specified and as directed NOTE :- Earth pit shall be constructed at least 0.5 metre away from each earth chamber.
Cutting chases, pinning in, where required for concealed conduit wiring, and making good disturbed surfaces to match with adjacent surfaces including pointing in cement mortar 1:3, girth not exceeding 15 cm on brick / PCC block masonry / concrete surfaces, complete all as specified and as directed.
Shanmuga Constructions
M.S.Trading Company
Eeguchi Constructions
Atom Engineers and Builders
ShaikPyarejanandsons
Vasavi Electricals
Sangam Construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .