| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹20.6 L+₹2.0 L (11.0%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
28 Dec 2020, 6:00 pmClosed
GE 863 EWS
GE 863 EWS C/O 56 APO
REPAIR MAINTENANCE OF LT LINES LT CABLES LT PANELS ACSR CONDUCTOR AND OTHER CONNECTED WORKS AT MATIANA AVERIPATTI JHAKRI KARCHAM POARI POOH KHAB NAMGIA DOGRI IN THE AREA OF AGE EM WE POOH UNDER GE 863 EWS
2020_MES_376892_1
GE/863/EWS-T-49 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
MATIANA AVERIPATTI JHAKRI KARCHAM POARI POOH KHAB
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 863 EWS
₹56,000
Yes
23 Jan 2021
1 Dec 2020
30 Dec 2020
1 Dec 2020
28 Dec 2020
16 Dec 2020
Amount
Dismantaling of Structural steel rusted broken or damaged as in crossarms etc. complete all as specified and directed.
Dismantling /disconnecting existing unserviceable ACSR conductor of any type complete all as specified and directed.
Dismantling /disconnecting existing unserviceable LT line separators of any description and size complete all as specified and directed.
Dismantling /disconnecting existing unserviceable LT line insulator of any type and any size complete all as specified and directed.
Dismantling /disconnecting existing unserviceable Stay assembly of any size with rod and accessories complete including excavation and demolition of concrete complete all as specified and directed.
Dismantling of steel pole of any size and any length complete all as specified and directed.
Dismantling /disconnecting existing unserviceable service wire/cable of sizes 6 Sqmm to 10 Sqmm complete all as specified and directed.
Dismantling /disconnecting existing unserviceable Earthwire of any size complete all as specified and directed.
Dismantling /disconnecting existing unserviceable Galvanised stay strand complete all as specified and directed.
Taking down unserviciable outdoor LT panel with MCCB and other fittings and fixtures after disconnecting the electric supply comlete all as specified and directed.
Taking down Aluminium TPN busbar/Changeover any size and any capacity after disconnecting the electric supply complete all as specified and directed.
Excavation in trenches n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundation for poles, stay, laying cables etc and getting out in hard/dense soil all as specified and directed .
Excavation in trenches not exc 1.5 mtr wide and exc 1.5 m but not exc 3 mtr in depth in hard/dense soil for fixing of steel tubular pole/stay pit complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm in hard/dense soil all as specified and directed .
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point all as specified and directed by engineer-in-charge.
M&L for Sand cushioning for under ground cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable all as specified and directed.
Supply and lay well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench all as specified and directed.
Supply and laying in replacement GI pipe light grade galvanized with all fittings laid in trenches for cable protection of 50 mm bore all as specified and directed .
Supply and laying in replacement GI pipe light grade galvanized with all fittings laid in trenches for cable protection of 80 mm bore complete all as specified & directed .
Supply and laying in replacement XLPE insulated, GI strips armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 70 Sq mm, 3.5 core including jointing and testing complete all as specified and as directed.
All as per srl item No 20 above but size 35 Sq mm, 3.5 core all as specified and directed.
All as per srl item No 20 above but size 16 Sq mm 4 core all as specified and directed.
All as per srl item No20 above but size 10 Sq mm, 2 core all as specified and directed.
Supply & laying in replacement cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 25 sq mm 3.5 core laid in trenches/fixed on pole/wall/passed through pipe complete including jointing and testing complete all as specified & directed .
All as per item no 24 above but size 95 sqmm 3.5 core
All as per item no 24 above but size 120 sqmm 3.5 core
Supply and laying in replacement cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminium conductor for working voltage upto and including 1100 volts, cross sectional area of cable 50 sq mm 3.5 core laid in trenches/fixed on pole/wall/passed through pipe complete including jointing and testing complete all soecified and directed .
All as per item no 27 above but size 300 sqmm 3.5 core
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 95 sq mm complete all as specified and directed.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 35 sq mm all as specified and directed .
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 25 sq mm all as specified and directed .
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 16 sq mm all as specified and directed .
Supply and fix straight joint heats hrinkable type of LT cable for size 16 Sq mm to 35 Sq mm 3.5/4 core 1100 volts complete all as specified and directed.
All as per srl item No. 33 above but size 120 Sq mm to 185 Sq mm all as specified and directed .
Refixing of existing steel tubular swaged poles of any size including painting with one coat of aluminium paint and black bitumen paint on hidden surface in foundation complete all as specified and directed. NOTE:- (i) Steel poles retrieved from Srl Item No 06 shall be used. (ii) excavation and PCC work shall be measured and paid separetaly at appropriate items.
M&L for steel tubular swaged poles with ISI marked complete with cast iron base plate, finial taper plug, bolts, nuts & screws all as specifed type 410 SP -31 (9 mtr long LT poles) and incl painting with one coat of red oxide and two coats of aluminium paint and black bitumen paint on hidden surface in foundation including drilling of holes for fixing 'D' iron clamps & hooks for contineous GI earth wire, erecting in a truly vertical position complete all as specified and directed . NOTE:- Excavation and PCC work shall be measured and paid separetaly.
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) with swan neck brackets including junction box and painting with one coat of aluminium paint including painting with black & white colour paint in alternate strip to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed.
Note : (i) PCC coping shall be painted with two coat of cement based paint of white colour .
(ii) Marking of pole No. shall be with black colour on yellow circled surface of minimum 150 mm dia.
S&F ACSR conductor steel re-inforced of any size on pole including binding wire and line taps of appropriate size & type complete all as directed .
Fixing only and stringing ACSR conductor of any size in accrodance with site requirement and binding on insulators by means of aluminium binding wire tapes complete all as specified and directed. Note: ACSR conductor retrieved from Srl Item No 02 shall be used.
Removing and dismentalling old U/S over head line conductor ACSR of any size ( 2 line per pole) and then cleaning and restringing in original position incl binding with new aluminium conductor complete all as specified and directed. Note : (a) The rate quoted are inclusive of cutting/ removing all tree branches/vegetation around 3 mtr of distance from the pole. (b) Length of span is approx 30 mtrs with 02 run of conductor. (c) Adjusting & tightning of stay assembly shall be done wherever required.
Removing and dismentalling old U/S over head line conductor ACSR of any size ( 4 line per pole) and then cleaning and restringing in original position incl binding with new aluminium conductor complete all as specified and directed. Note : (a) The rate quoted are inclusive of cutting/ removing all tree branches/vegetation around 3 mtr of distance from the pole. (b) Length of span is approx 30 mtrs with 04 run of conductor. (c) Adjusting & tightning of stay assembly shall be done wherever required.
Supply and fixing in replacement of FRP cable junction boxes including bus bar (04 Nos) of existing size including provision for fixing to existing poles with 02 Nos MS clamps of flat 40x6mm suitable size complete with nuts & bolts making connection with cable & including thimbles at suitable size complete all as specified and as directed.
Supply and fix PVC line phase separators for over head line LT conductor of any size suitable to stand 1100 volts to maintain the required spacing between 5 conductors complete all as per site requirement and all as directed .
Supply install testing and commissioning Feeder panel cubical panel of double door outdoor type factory made dust/vermin proof made out of CRCA sheet 3.15 mm thick CPRI approved duly powder coated having opening and locking arrangment both in front and rear side (Independent door for each item on front side) mounted on 1 No angle iron 45 x 45 x 6mm, 45 cm long embedded in PCC 1:3:6 type C2 with complete incl provision of following accessories and suitable for fixing of under mentioned items :-
(a) Aluminium bus bar chamber capacity 300 Amps 3 Phase 4 wire duly insulated with PVC sleeves (As per colour code) incl complete control wiring with suitable size PVC copper conductor cable and provn of cable lugs etc.
(f) MCCB 100 Amps, 25 KA with adjustable thermal and magnetic settings - 02 Nos (Outgoing), (g) MCCB 63 Amps, 25 KA with adjustable thermal and magnetic settings - 02 Nos (Outgoing),
Supply, install, testing and commissioning LT Panel cubical outdoor type dust/vermin proof made out of CRCA sheet 3.15mm thick CPRI approved duly powder coated having opening and locking arrangement both in front and rear side mounted on 4 Nos angle iron 40x40x6 mm - 0.45 m height embedded in PCC 1:3:6 type C2 including Aluminum bus bar capacity 600 Amps,3 phase, 4 wire duly insulated with PVC sleeves (colour coded) including complete control wiring with suitable PVC copper conductor cables and necessary cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl provision of the following accessories/eqpt incl cable gland etc (for power house) and suitable for housing of following:-
Incoming
a) MCCB 400A, 4Pole , 50KA with adjustable thermal and magnetic settings -01 No (Incoming)
(b) Voltmeter 0 to 500 Volt -01 No
(d) LED Phase Indication lamp (RYB) -01 Set
Outgoing
a) MCCB 4Pole 250A 36KA, with adjustable thermal and magnetic settings -02 Nos
b) MCCB 4P 100A 25KA with adjustable thermal and magnetic settings- 02 Nos
e) On load change over switch 400A, 4 pole -01 No
Supply, install, testing and commissioning LT Panel cubical indoor type made dust/vermin proof made out of CRCA sheet 3.15mm thick CPRI approved duly powder coated having opening and locking arrangement both in front and rear side mounted on 4 Nos angle iron 40x40x6 mm - 0.45 m height embedded in PCC 1:3:6 type C2 including Aluminum bus bar capacity 600 Amps,3 phase, 4 wire duly insulated with PVC sleeves (colour coded) including complete control wiring with suitable PVC copper conductor cables and necessary cable gland for incomming and outgoing cables with lugs and connections etc required nuts ,bolts and washer incl provision for suitable for fixing of the following accessories/eqpt incl cable gland etc (for Supply) and suitable for housing of following:-
Incoming
a) MCCB 400A, 4Pole , 50KA with adjustable thermal and magnetic settings -01 No (Incoming)
(b) Voltmeter 0 to 500 Volt -01 No
(d) LED Phase Indication lamp (RYB) -01 Set
Outgoing
a) MCCB 160 Amps 4Pole, 25KA, with adjustable thermal and magnetic settings -04 Nos
b) MCCB 100A, 4Pole, 25KA with adjustable thermal and magnetic settings- 02 Nos
c) MCB SPN 40 Amps, 10 KA - 06 Nos
Note for LT Panels : (i) The contractor will submit the drawings before placing purchase order of the panel for approval of Engineer-in-Charge. (ii) All incoming & outgoing feeders shall be connected by cable through suitable size gland, Plate/glands , thimbles etc
M&L Earthing complete with GI earth plate electrode 60x60cmx6.3mm thick buried directly in ground earth pit not less than 2.25m deep below ground level with top edge of the plate not less than 1.5m below normal ground level connected to GI earth strip 32x6 mm dia protected by GI pipe light grade 15mm dia, 20 mm medium grade for watering with funnel including test point up to 7.5 meter from earth pit, common salt, charcoal dust and connected to panel bd/DB by means of bolts and nuts washers made out of GI all as shown in Electrical plate No 3 of SSR part I including necessary earth work and excavations in any type of soil PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 cover slab with 6mm dia MS bars at 100mm C/C both ways with MS hook of 6mm dia MS bars etc complete including taking out old earthing materials complete all as specified and directed.
S&F in replacemant of Aluminium strip of 25x4 mm size mounting on insulators complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 6 Sqmm complete all as specified & directed .
S&F1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4 mm suspension wire, one twin core cable flat of size 10 Sqmm complete all as specified & directed.
S&F in replacement of MCCB 100 Amps, 4 pole 415 volts 3 phase 50 HZ with Adjustable Thermal & adjustable Magnetic setting of rapturing capacity 25 KA. complete all as specified and directed.
S&F in repair MCCB 3 pole 415V, fixed type of capacity 100 Amps with breaking capacity 16 KA.complete all as specified and directed .
S&F in repair MCCB 4 pole 415V, Adjustable type of capacity 160 Amps with breaking capacity 36 KA.complete all as specified and directed .
S&F in repair MCCB 4 pole 415V, Adjustable type of capacity 200 Amps with breaking capacity 36 KA.complete all as specified and directed .
S&F in repair MCCB 4 pole 415V, Adjustable type of capacity 250 Amps with breaking capacity 36 KA.complete all as specified and directed .
S&F in repair MCCB 4 pole 415V, Adjustable type of capacity 400 Amps with breaking capacity 36 KA.complete all as specified and directed .
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 100 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with connected fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc all as specified and directed .
S&F in replacement of off load changeover switch in sheet metal enclosure four pole 63 Amps capacity suitable for 415 volt, 50 Hz with side operating handle complete with fixing arrangement switches, fastness, gutties etc. for fixing the same on wall / panel etc complete all as specified and directed.
S & F of aluminium TPN bus bar chamber of capacity 100 amps, 415 volt with proper insulator mounting/routing in properly on wall/surface with suitable PCC/Nuts & bolts complete all as specified and directed .
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate for poles / stays foundation complete all as specified and directed.
M&L for cement concrete (1:3:6) type C1 with 20 mm graded aggegate for pole coping & road crossing including form work and finishing to all exposed surfaces by using extra cement all as directed.
M&L for replacement of galvanised steel wire 4 mm dia/8mm dia. For guard wire, continuous earth wire complete all as specified and directed.
M&L for cross arms bracings, supports, clamps and back plates fabricated from structural steel sections incl nut & bolts , washers welding, bending cold or hot drilling holes for bolts, washers in any shape or size as indicated or directd incl one primer coat, one under coat & and one finishing coat of synthetic enamal paint complete all as specified & directed.
M&L for galvanised stay strand 7/3.15 mm size complete all as specified and directed.
M&L for pin type, porcelain vitreous, white, brown or green insulator incl one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 100 mm height 65mm dia for 1100 Volts grade complete all as specified and directed.
S&F shackle type porecelain vitreous white brown or green insulator for working pressure 1100 volts of 90mm dia and 75mm height incl galvanised steel straps of 31x3 mm size insulator and 12 mm dia bolt,washer & nuts complete all as specified and directed.
S&F synthetic line separators of LT OH lines with nut,bolts & washers straight type horizontal configuration fixed at a point as directed and suitable for single phase 2 wire LT lines complete all as specified and directed.
All as per Srl Item No70 above above but suitable for 4 wire.
S&F Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamalled white, with letters, figures and colour and fixed with M.S.clamps,bolts and nuts of approoved size, for LT, 20x15 cm size,complete all as specified and directed .
S&F Porcelain of size 30 amp , 4mm dia line wire, arerial fuses suitable for line wire, with brass contact bolts and nuts complete all as specified and directed .
Supply and fix in replacement of Bus bar chamber box in sheet metal enclosure 200 Amps capacity, 4 way, 415 V complete all soecified and directed . MAKE:- Havells Cat Part No IHBB020004 or equivalent model of make as per Appx 'B' as approved
Supply and fix in replacement of on load change over 4 pole with side handle, 415 volt AC, 50/60Hz, 200 amps with suitable sheet metal enclosure complete all as specified and directed.
Supply and fix in replacement of on load change over 4 pole with side handle, 415 volt AC, 50/60Hz, 320 amps with suitable sheet metal enclosure complete all as specified and directed.
Supply & fixing stay assembly for electric pole complete with accessories as shown in electrical plate No 1 of SSR Part -I and drg using loop type insulator, stay clamps, stay rod of 16mm dia complete all as specified and directed. Note : Excavation & PCC will be measured and paid separately under respective items.
Net Contract Sum will be after deducting Sch Of Credit of Rs. 127894.00
A P ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .