| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC H O PRABHAT KUMAR SINHA RAGHUNATH TOLA ANISABAD PATNA 800002 | PATNA | PATNA | BIHAR | 800002 | 1 | Accepted-AOC ok | |
| 2 | 2₹8.4 L+₹56,155 (7.20%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | 2 | Rejected-Finance Quoted rate more than L1 | |
| 3 | 3₹9.1 L+₹1.3 L (16.6%)Rejected-Finance T 3 HILL CREST APARTMENT BEHIND AMBABAI TEMPLE VASCO DA GAMA GOA 403 802 | VASCO DA GAMA | SOUTH GOA | GOA | 403802 | 3 | Rejected-Finance Quoted rate more than L1 | |
| 4 | 4₹16.8 L+₹9.0 L (115.2%)Rejected-Finance 29 KESHULI AKOUR MADHUBANI MADHUBANI BIHAR 847230 UDYAM BR 20 0037592 | MADHUBANI | BIHAR | 847230 | 4 | Rejected-Finance Quoted rate more than L1 |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
2 Dec 2020, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta Pin-801103
Repair/Maint of all internal fittings fixtures appliances/internal wiring, electric meter, heating and cooling appliances bldg security lights and earthing works at AF Stn Darbhanga under GE (AF) Bihta
2020_MES_392898_1
8118/BHT/DBG/E8
Open Tender
Miscellaneous Works
Item Rate
120 days
Darbhanga
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹20,000
Yes
18 Dec 2020
5 Nov 2020
4 Dec 2020
5 Nov 2020
2 Dec 2020
16 Nov 2020
Amount
Taking down carefully aluminium/copper wiring/power pont wiring(light,fan,call bell,socket or power circuits)complete and making good the disturbed surfaces of walls,ceiling etc including painting with same colour of the back ground complete all as specified and as directed.
Material and labour for point wiring complete for One light/fan point with 1.5 Sq mm nominal cross sectional area, single core,1100 Volt grade,multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable 1100 volt grade confirming to IS-694 , drawn through and including rigid non-metallic PVC conduit of 20 mm dia or higher as per site requirement, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting chases in wall and replacement terminal boxes with sunk zinc coated pressed steel terminal box of 1.60 mm thick sheet covered with 3 mm thick plastic laminated sheet top cover , brass screws, cup washers etc with and including 1.5 Sq mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded , PVC insulated, unsheathed , FRLS copper conductor cable continuous earth wire and connected to common earth and earth dolly with suitable copper lugs and and making good to the disturbed surfaces to match the existing complete all as specified and directed .
All as per serial item no.2 here-inbefore but for one socket outlet 3 pin , 5 Amps on indepedent board complete all as specified and directed.
All as per serial item no.2 here-inbefore but for one socket outlet 3 pin , 5 Amps on same board with other switches complete all as specified and directed.
All as per serial item no.2 here-in- before but for for fan point controlled by one 5/6 amp switch one way complete all as specified and directed.
(d)All as per serial item no.2 here-in- before but for for bell point controlled by one bell push 5/6amp one way complete all as specified and directed.
All as per item No 2 here-in-before but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 2.5 sq mm connected to common earth dolly all as specified.
Supply & fixing in repair of LED tube rod of capacity 20 watt single side complete all as directed. Make: Havells cat pat no LHLDEFXD5L8R020 or eqvl in Philips/crompton
Supply & fixing in repair 22 watt single side LED light fitting fixture with extruded AL heat sink,environmental friendly,ready to use suitable for 4 ft LED tube complete all as directed Make: . Havell cat pat no- 22WSSBSWH or equivalent in philips / crompton/Syska/Surya Roshni/Bajaj
Supply & fixing switch piano, flush type, 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of switch piano, flush type, 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing socket outlet, flush type, 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of socket outlet, flush type, 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing ceiling rose three terminal surface bakelite 65X50mm size 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader .
Supply & fixing Switch socket Combination 2 in 1, 5 Amps flush type 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of Switch socket Combination 2 in 1, 5 Amps flush type 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing switch Socket combination 2 in 1 3 pin 5 Amps and 15 Amps controlled by one switch 230 volt AC confirming to IS-1293-2005 complete all as directed.Make : Havells/ Kinjal / Plaza / Leader
Supply & fixing in repair swich Socket combination 2 in 1 3 pin 5 Amps and 15 Amps controlled by one switch 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of swtich 15 Amps 230 volt AC confirming to IS-1293-2005 complete all as directed.Make : Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of Socket outlet 2 in 1, 3 pin, 5 and 15 Amps controlled by one switch 230 volt AC confirming to IS-1293-2005 complete all as directed.Make:Havells/Kinjal/Plaza/Leader .
Supply & fixing bell push , 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of bell push , 5 amps, single pole, one way 230 volt AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing of call bell, Ding dong type, single pole 230 volts AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair call bell, Ding dong type, single pole 230 volts AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing ceiling fan regulator electronic single pole 230 volts AC confirming to IS-1293-2005 complete all as directed.Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of ceiling fan regulator electronic type all as directed single pole 230 volts AC confirming to IS-1293-2005 complete all as directed.Make Havells/Kinjal/Plaza/Leader
Taking down old unserviceable main switch/DBs/MCB DBs with MCB including making good the disturbed area complete as directed
Supply & fixing in repair factory made epoxy powder coated Distribution board Triple pole and neutral 4 way 415 volt grade(TPN MCB DB) with single door and fixed flush to wall suitable for universal mounting, including 200 Amps rated bas bar , neutral neutral bar, earth bar and standard Din rail ,Earth bar and cable ties for cable management,top and bottom removable gland plates complete all as specified. Make L&T (Lexic)/Legrand/ Havells India/ Scheinder
Supply and fix in repair factory made epoxy powder coated sheet metal enclosure distribution board, single pole and neutral, 08 way AC, 240 volt, (SPN MCB DB) with single door and fixed flush to wall suitable for universal mounting, including 200 Amps rated bas bar , neutral neutral bar, earth bar and standard Din rail ,Earth bar and cable ties for cable management,top and bottom removable gland plates complete all as specified. Make : L&T (Lexic)/Legrand/ Havells India/ Scheinder
Supply & fixing in repair factory made epoxy powder coated Distribution board single pole and neutral 4 way 240 volt grade(SPN MCB DB) with single door and fixed flush to wall suitable for universal mounting, including 200 Amps rated bas bar , neutral neutral bar, earth bar and standard Din rail ,Earth bar and cable ties for cable management,top and bottom removable gland plates complete all as specified. Make L&T (Lexic)/Legrand/ Havells India/ Scheinder
Supply & fixing in repair factory made epoxy powder coated Distribution board single pole and neutral 2 way 240 volt grade(SPN MCB DB) with single door and fixed flush to wall suitable for universal mounting, including 200 Amps rated bas bar , neutral neutral bar, earth bar and standard Din rail ,Earth bar and cable ties for cable management,top and bottom removable gland plates complete all as specified. Make L&T (Lexic)/Legrand/ Havells India/ Scheinder
Supply and fix in repair Isolator DP, AC 240 volt of 63 Amp capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed.Make L&T (Lexic)/Legrand/ Havells India/ Scheinder
Supply and fix in repair Isolator DP, AC 240 volt of 40 Amp capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make L&T (Lexic)/Legrand/ Scheinder
Supply and fix in repair Isolator DP, AC 240 volt of6-40Amp capacity "c" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. Make L&T (Lexic)/Legrand/ Scheinder
Supply & fixing in repair of MCB TPN 32 Amps 415 volts ‘C’ curve having current rating 10 KA complete all as specified & directed. Make L&T (Lexic)/Legrand/ Scheinder .
Supply & fixing in repair of MCB TPN 63 Amps,415 volts ‘C’ curves having current rating 10 KA complete all as specified & directed. Make : L&T (Lexic)/Legrand/ Scheinder .
S & F in in repair LED security Light fitting complete 45 Watt,5700K, with high power energy saving pressure die cast aluminium IP 66 roadway luminiarys heat resistant toughened glass with frame better optics for uniform distribution with high power LED as Ligh source with the MS clamp made of 25X3 mm flat iron with bracket of GI pipe medium grade 25mm dia and not less than 1.2 mtr end of GI pipe suitable for street light including taking out old unserviceable one complete all as specified and as directed. Make :- CG Cat Pat No LSTP-45-CDL or equivelent make and model of Philips/Bajaj
Taking down old/unserviceable sub main wiring of any sizes including batten/conduit complete all as directed.
S&F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 4 sqmm as current carrying conductor and one run of 4.0 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed including taking down old unsv one. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.Make: RR cable/Universal/Plaza/Finolex
S&F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable2.5 sqmm as current carrying conductor and one run of 2.5 sqmm as earth contunity conductor ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 4 sqmm all as specified and directed including taking down old unsv one. Note: Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.Make: RR cable/Universal/Plaza/Finolex
Supply & fixing in repair decorative box type fittings with blue colour end cap for LED tube 22 watt luminiare for 230 volts ac including LED tube 22 watt complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make: Havells LHEXBTP7INSO22 or equivalent in specified make of Bajaj/Philips/HPL
Supply & fixingin repair f decorative batten type fittings with E-Lite LED Quadra Glow batten. 4 step dimming with a click of switch from 18W complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make:/HAVELLS -LHEXBLP7JN1W018 or eqv in CG /Bajaj/Philips/HPL/
Supply & fixing in repair of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. . Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair/replacement plug top 15A, 240 voltscomplete all as specified and directed. . Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair/replacement plug top 5A, 240 volts complete all as specified and directed. . Make :Havells/Kinjal/Plaza/Leader
Supply & fixing in repair of LED 15 watt retrofit bulb with holder base B-22 with polycarbonate body and aluminum heat sink complete all as specified and directed. Make :-Havells/Syska/Philips /Bajaj
Supply & fixing in repair/replacement LED 20 watt retrofit bulb with holder base B-22 with polycarbonate body and aluminum heat sink complete all as specified and directed. Make :-Havells/Syska/Philips /Bajaj
Supply & fixing in repair/replacement LED 5 watt retrofit lamp with holder base B-22 with polycarbonate body and aluminium heat sinkcomplete all as specified and directed. Make :-Havells/Syska/Philips /Bajaj , make :-Havells/ CG/HPL
Supply & fixingin repair LED 10 watt retrofit lamp with holder base B-22 with polycarbonate body and aluminium heat sink complete all as specified and directed. Make :-Havells/Syska/Philips /Bajaj
Supply & fixing in repair Decorative, wall mounting, SS finish fixture with opal glass diffuser suitable for 40W mini gls lamp or 8 wtu retrofit led lamp complete all as specified and directed. Make :Havell cat pat No-LHJC02108499 or eqv in philips/Cropmton/Bajaj
Supply & fixing in repair LED ceiling light (2x2) of 36 w,premium white powder coated frame blends seamlessly with ceiling layout suitbale for 600x600 mm mudular ceiling grid all as specified and directed.Make : Crompton,cat no-LCPL-36-CDL(2X2) OR eqv in Havells/Philps/Bajaj/Syska.
Taking down carefully ceiling fan /Exhaustfan /cabin fan of any sweep and any make sealing cable ends , dismantling blades removing from the site for carrying out necessary repair to make it functional writing MES NO. with black paint and refixing the same complete all as specified and directed.Note: Spare parts/items if any require for smooh functioning of fans shall be measured and paid under appropriate items .
M & L for rewinding of ceiling /exhaust /wall mounted /cabin / table fan retrieved vide item No. 48 hre-in-before with super enameled copper winding wire of same size / gauge as per existing one reassembling and testing in the presence and to the entire satisfaction of Engineer-in-charge complete all as specified and directed for the following type of fans.(a) Ceiling fan of any Make 1200 mm to 1400 mm sweep
(b) Exhaust fan of any Make 300mm to 380mm sweep.
(c ) Cabin fan/wall fan/table fan/pedestal fan 400 mm sweep.
(d ) PVC AIR freshner off sizes sweep.
M & L for overhauling of ceiling fan any Make and sweep including taking down vide item No. 48 hre-in-before, dismantling, cleaning internally and externally, oiling, greasing, checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers etc. reassembling and testing in the presence and to the entire satisfaction of Engineer-in-charge complete all as specified and directed
All as specified in item No.50 here-in-before but for exhaust fan of any Make and any size.
Supply only followig spares/items for incorporaion in fans taken down for repair vide iten no.48 here-in-before all as directed . (a) Ball bearing of suitable size for ceiling fan/Exhaust fan of any size and sweep.
(b) Rubber reel with nut bolt and washers for hanging of ceiling fan any size.
(c)MS Clamps with nut bolts and washers for hanging of ceiling fan of any size.
S&F fixing in repair of sheet metal enclosure single pole neutral with a two pin and earth plug and socket with one single pole MCB 20 amp 240 volts complete all as specified and as directed. Make :Havells/Kinjal/Plaza/Leader
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe light grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia light grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed by Engineer-in-Charge. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth strip/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. aqs required 20X3 mm copper strip including taking down/out old unsv earth strip complete all as specified and as directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthling etc. as required 4mm dia galvanised iron or steel wire including taking down/out old unsv earth strip complete all as specified and as directed.
S&F in repair electric meter 16 Amp single phase,electronic type including taking down old/unserviceable one all as specification and directed. Make-Havells/L&T/ Legrand
Supply and fixing in repair of decorative wall mounting type SS finish fixture with opal glass diffuser suitable for 15 W LED bulb, 230 Volt lamp holder, 15 Watts LED lamp B22 CDL etc and all accessories pre-wired including connecting up complete all as specified and as directed. Make: Havells, Cat No. LHJE01106499 (Aristo) or equivalent in Philips or CG.
Supply & fixing in repair of candenser 2.5 MFD complete all as specified and as directed.Make :-Epcos/Havells/Usha
Supply & fixing in repair of candenser 4 MFD complete all as specified and as directed. Make-Epcos/Havells/Usha
Supply & fixing in repair of Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. Make-Siemens/L&T/ Legrand/ABB
S&F in repair submersible pump of desert cooler, single phase 18 watt 220 volt 50 HZ as per existing size & specification commissioning and testing inthe presence and to entire satisfaction of Engineer-in-charge including taking out the old one complete all as specified and as directed . Make- Crompton Greaves/Bajaj/Usha/Khaitan
Material and labour for disconnect electric connection, taking down/ keep aside the air conditioner (Split/Window), Water Cooler and Refrigerator including stabilizer of any make and capacity. Servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the respective items.)
Fixing only split /window AC of 1.5/2.0 TR cooling capacity of any make/model installation of indoor and outdoor unit where as directed, making hole through the wall for passing the suction /discharge line and PVC coduit of 15mm dia n.exc.2.5mtr long in concealed surface of wall for drainage of water occurs due to humidity, making good to disturbed surfaces with cement mortor of ratio1:3 finishing to match and testing complete all as directed. Note: Quoted unit rate shall be inclusive of transporting of AC unit from Age E/M office to site and vice-versa.
Material and labour for disconnect electric connection, taking down/ keep aside the air conditioner (Split/Window), Water Cooler and Refrigerator including stabilizer of any make and capacity. Servicing the same as cleaning inside, by mean of cleaning of filter, remove dust from body, tightening of loose nut bolt, washer, rubber gas kit and tightening of loose wiring, loose connection, replacement of wornout, nutbolt, washers, gaskits etc and necessary cutting, welding/ soldering works with replacement of rusted body parts with new MS/GI Sheets of suitable size and made functional the equipment fully and Re-installation in position and testing complete all as specified and as directed by Engineer-in-charge. Note: (All new spare parts will be measured and paid separately under the respective items.)
M& L for Dismantling of unserviceable/worn hermetically sealed unit compressor from window /Split type AC and replacement with new one compressor , suitable for existing same model/make of capacity 1.5 TR split/window type AC including brazing with suction and discharge line, checking the system for leak proof and inclduing charging of refrigerant gas R-134 A in appropriate qty after making vacume the complete system and testing the A/C for proper functioning all as directed.Make: Kirloskar / Techumesh / Carrier / Blue Star/LG/Sri-ram
All as per serial item no.66 here-in-before but of Capacity 2.0 TR window / split type AC
Supply only the following spares/items required for incorporation in AC's taken down vide item no,63 here-in-before to make it fully functional in the presense and to entire satisfaction of Engineer-in-charge and testing complete all as specified and directed by Engineer-in-charge. Note : All the repairs shall ensured to be carried out at AGE E/M store yard including transportation of equipment from site to office and vice versa for re-fixing at site. (a) Cooling coil complete with fins made of copper suitable for 2Ton/1.5 Ton capacity Window/Split type AC.as per existing size and specification Make : LG/Voltas/Hitachi/Voltas.
(b) Copper condensing coil complete with fins suitable for 2Ton/1.5 Ton capacity Window/Split type AC.as per existing size and specification all as directed. Make : LG/Voltas/Hitachi/Voltas.
(c)Fan motor for water cooler upto 120Ltr capacity all as directed. Make : CG/ Kirloskar/Blue Star/Bajaj/Khaitan.
(d) Fan blade suitable for AC's blower/ water cooler motor and all as directed.
(e) Copper condensing coil made of copper suitable for water cooler upto 120 Ltr capacity all as directed. Make : Voltas/Blue Star/Voltas/Hitachi.
(f) Copper cooling coil suitable for water cooler upto 120 Ltr capacityall as directed.Make : Voltas/Blue/Star/Voltas/Hitachi.
Material and labour for taking down of electric water heater from wall of capacity 25/50ltrs, Dismantling/opening the same, servicing, cleaning Internally and externally, replacement of wornout, MS nut, bolts, washers, clamps etc and made functional fully functional,tested in the presence and to entire satisfaction of Engineer-in-charge & refixing the same or other position as directed complete all as specified and directed.
Supply only the following items required to be replaced to make the water heater taken down vide iten no.69 here-in-before fully functional in the presence and to the entire satisfaction of Engineer-in-charge omplete all as specified and directed. (a) Elect water heater element 2/1.5KW,ISI marked, as per existing size and specification,Make-Havells/Bajaj/CG/Khaitan or eqv in crompton or havells
(b) Apparatus (Syphon assembly) plate as,ISI marked, as per existing size and specification and make all as directed.
M/S vibhuti enterprises
U k Enterprises
A K C PROJECT
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .